Documentation record
Registered dimensions (L × B × D)80.8 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)80.8 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 168 / net 60
BuilderSKIPPERLINER INDUSTRIES · LACROSSE, WI, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portALAMEDA, CA
Endorsements, as the file codes themcw_un, rec, reg
DocumentationValid · issued 2 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
168 - Convention (Subpart B), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
60 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
23 June 2026
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8407221
31 March 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8100704
25 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7883517
9 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684439
30 April 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7678665
30 April 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7678912
22 February 2023
Hull Examination · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7638432
11 April 2022
DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7418690
20 October 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7336559
21 April 2021
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7178169
6 April 2021
Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7169977
2 March 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7149141
20 April 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6942424
30 March 2020
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6961015
24 January 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6895249
24 January 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6907091
8 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6742497
21 February 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6629555
26 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548895
19 March 2018
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6374787
12 April 2017
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6121283
1 February 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6076517
28 March 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5842472
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2025
Resolved
All metallic enclosures and frames of electrical equipment must be permanently grounded to the hull on a metallic vessel. Vessel battery charger is missing its grounding cable.
46 CFR 183.372(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 15 April 2025
Resolution: groundig wire installed, all sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 March 2025
Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Vessel's port bow vent closure does not fully close.
46 CFR 177.405(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 15 April 2025
Resolution: Ventilation now closes all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 31 March 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's port life float was found degraded and missing sections of foam and needs to be repaired.
46 CFR 176.808(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 15 April 2025
Resolution: Life float has been repaired all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 31 March 2025
Resolved
The float-free link required by § 180.130(a)(1) must be:(2) Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. MI was unable to verify identification tag during inspection.
46 CFR 180.137(b)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 2 April 2025
Resolution: Received photo of tag all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 31 March 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel is missing the radio station license.
46 CFR 184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 2 April 2025
Resolution: Sent photo of FCC document all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 31 March 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel is missing the Radio Telephony Certificate.
46 CFR 184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 2 April 2025
Resolution: Sent photo of FCC document all sat.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 31 March 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station. Vessel was unable to provide emergency instructions.
46 CFR 185.510(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 2 April 2025
Resolution: Submitted photo of instructions all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: (c) Minimize accidental personnel contact with energized parts. Vessel was found with an uncovered spliced wire for the aft speakers underneath the adult life jackets.
46 CFR 183.200(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 15 April 2025
Resolution: Vessel removed spliced wire and replace with one complete wire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Vessel was unable to find the cover to the adult life jacket storage area to verify the appropriate markings are listed.
46 CFR 185.604(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 2 April 2025
Resolution: Submitted photo of signage all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2024
Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard. The vessel did not have nonconducting mats in front of the switchboards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 10 April 2024
Resolution: Vessel rep sent satisfactory photos showing the nonconductive mat in front of the switchboard.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 March 2024
Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. The port rudder post shows signs of deterioration. Make repairs prior to next credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2025
Resolution: Vessel made satisfactory repairs to port rudder post, picture attached to doc tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2023
Resolved
Piping used in a vital system must be composed of ferrous material. Vessel's bilge strainers are non-metallic.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 24 May 2023
Resolution: Verified installation of metallic strainers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2023
Resolved
At each inspection, the operator must be preparted to conduct inspections of the firemain system. The vessel's firepump is leaking at the packing gland.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 24 May 2023
Resolution: Verified firepump leak repair.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 May 2023
Resolved
Glass used in windows accessible to passengers and crew must be capable of withstanding maximum load expected due to route. Vessel's starboard aft main deck window is cracked.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 8 September 2023
Resolution: Received photograph of replaced window; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 April 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements. Vessel experienced equipment failure to STBD engine shifter cable while attempting to dock. Complete repairs satisfactory to attending Marine Inspector prior to carriage of passengers.
46 CFR 182.200 (a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Vessel replaced STBD ENG shifter cable. Attended vessel to verify installation and operation of all associated components. Witnessed satisfactory operation of engine controls.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2019
Resolved
A submersible electric bilge pump must have a positive shutoff valve installed at the hull penetration. The submersible electric bilge pump in Engine Room does not have a shutoff valve at the starboard side hull penetration. Install positive shutoff valve IAW 46 CFR 182.520.
46CFR182.520(e)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 15 July 2019
Resolution: Recieved photograph of valve properly installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 May 2020
Resolution: Verified through NAVCEN's AIS verification website that outstanding AIS error has been cleared.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 12 April 2017
Resolved
Pressure switch for ventilation shutdown was located in space protected. Relocate pressure switch outside space and prove proper operation. 46CFR181.410
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 16 June 2017
Resolution: Pressure switch was moved outside the space to the tank room and system tested; all sat.