MAURY USCG vessel records Sign in
← All vessels

RELAXIN

RELAXIN is a 1975 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 1985, most recently in June 1999, along with 38 deficiencies.

Records from 1985 to 1999. Most recent: inspection, 29 June 1999.

Built
1975
Last inspected
29 June 1999
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYC4372
Flag
UNITED STATES
—
Maury page id
psix-48493

Inspections, by type

…with no type recorded2
Years with a record 12 calendar years (1985–1999)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 18.0 ft × 6.7 ft
Registered tonnagegross 97 / net 81
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPROSPECT BOAT WORKS INC · PROSPECT KY, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 13 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
81 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

29 June 1999 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1080482
7 January 1997 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1098015
3 January 1997 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1105944
12 December 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 135425
1 July 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1454322
24 April 1996 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1089861
13 December 1993 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 849493
17 September 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1265709
22 August 1991 COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1252915
26 February 1990 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1214877
16 January 1990 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 914276
12 October 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1341219
12 September 1989 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1203233
6 October 1988 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1196219
9 September 1988 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1041772
21 May 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1331717
23 December 1986 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1335160
3 September 1986 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1316701
20 May 1986 Credit Drydock
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 996540
6 September 1985 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 989654
3 September 1985 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1296694

Deficiency record · 38

Accommodation/Occupational Safety
Issued 22 August 1991 Resolved
REPAIR TWO BROKEN WINDOWS, LOCATED STBD AFT AND PORT FWD.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Lifesaving
Issued 22 August 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Navigation
Issued 22 August 1991 Resolved
OBTAIN AND INSTALL PROPER BULBS IN NAV RUNNING LIGHTS.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Fire Fighting
Issued 22 August 1991 Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Fire Fighting
Issued 12 September 1989 Resolved
INSTALL REMOTE ACTIVATION SYSTEM AND ALARMS FOR FIXED HALON SYSTEM IN ENGINE AND GENERATOR ROOMS.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989 Resolved
INSTALL APPROVED FITTINGS ON STARBOARD GENERATOR FUEL LINES.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989 Resolved
PROVIDE EMERGENCY BATTERY DISCONNECT SWITCH FOR ALL BATTERIES.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Construction/Loadline
Issued 12 September 1989 Resolved
AT NEXT DRYDOCK, REMOVE UNUSED 1/2" PIPE, MID SHIP COMPARTMENT THRU HULL FITTING.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989 Resolved
SECURE GENERATOR BATTERY BOXES FROM SHIFTING.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Fire Fighting
Issued 12 September 1989 Resolved
PROPERLY MOUNT ALL FIRE EXTINGUISHERS
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Accommodation/Occupational Safety
Issued 12 September 1989 Resolved
PROVIDE CERTIFIED MSD. TOILETS TO BE SECURED UNTIL COMPLETED. VOYAGE DURATION LIMITED TO 30 MIN UNTIL MSD INSTALLED.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Engineering
Issued 12 September 1989 Resolved
PROVIDE PLAME SCREENS IN ALL FUEL TANK VENTS
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Accommodation/Occupational Safety
Issued 12 September 1989 Resolved
PROVIDE INSECT SCREENS IN ALL POTABLE WATER TNAK VENTS
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Lifesaving
Issued 9 September 1988 Resolved
PROVIDE DISTRESS FLARES AND WATERPROOF CONTAINER. 46 CFR 180.35
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Construction/Loadline
Issued 9 September 1988 Resolved
REMOVE ALL PLASTIC THROUGH-HULL FITTINGS AND REPLACE WITH MELTALLIC FITTINGS. 46 CFR 182.40-1(E)
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Accommodation/Occupational Safety
Issued 9 September 1988 Resolved
INSTALL INSECT SCREEN IN PORTABLE WATER VENT.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Accommodation/Occupational Safety
Issued 9 September 1988 Resolved
REPAIR/REMOUNT AIR CONDITIONING CIRCULATION PUMP.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Electrical
Issued 9 September 1988 Resolved
PROVIDE GUARD FOR GENERATOR BELT DRIVES. 46 CFR 177.35-15.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Engineering
Issued 9 September 1988 Resolved
REMOVE SHIP'S STORES INWAY OF FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Documentation
Issued 9 September 1988 Resolved
POST STABILITY LETTER. 46 CFR 185.12
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Accommodation/Occupational Safety
Issued 9 September 1988 Resolved
INSTALL RAILING IN MAIN LOUNGE FOR 2 STEPS BEHIND STEERING STATION.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Fire Fighting
Issued 9 September 1988 Resolved
PROVIDE PROPER NOZZLE FOR FIRE HOSE. 46 CFR 181.15-10(E)
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 9 September 1988 Resolved
PROVIDE 15 ADULT LIFE PRESERVERS. PASSENGER CAPACITY REDUCED TO 36.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Fire Fighting
Issued 9 September 1988 Resolved
SERVICE HALON SYSTEMS.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 3 September 1986 Resolved
MARK VESSELS NAME ON ALL LIFE JACKETS.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Fire Fighting
Issued 3 September 1986 Resolved
MAKE PERMANENT REPAIRS TO LEAK IN THE FIREMAIN LOCATED ON CENTER LINE IN ENGINE COMPARTMENT
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Fire Fighting
Issued 3 September 1986 Resolved
CONDUCT ANNUAL SERVICING ON ALL PORTABLE AND FIXED FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Electrical
Issued 3 September 1986 Resolved
PROVIDE COVER FOR ELECTRICAL BOX LOCATED IN FORWARD COMPARTMENT, PORT SIDE.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Lifesaving
Issued 3 September 1985 Resolved
REPLACE ATTATCHMENT LINE TO RING LIFEBOUY LIGHT.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Electrical
Issued 3 September 1985 Resolved
INSTALL BATTERY COVERS ON ALL BATTERIES.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Documentation
Issued 3 September 1985 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Lifesaving
Issued 3 September 1985 Resolved
MARK ALL LIFE JACKETS WITH VESSELS NAME.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Fire Fighting
Issued 3 September 1985 Resolved
INSTALL FIRE AND BILGE PUMP AND TEST OPERATION.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Lifesaving
Issued 3 September 1985 Resolved
REPLACE HAND LINE ON RING LIFE BOUY.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Electrical
Issued 3 September 1985 Resolved
REMOVE PARTY LIGHTS ON UPPER DECK.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Construction/Loadline
Issued 3 September 1985 Resolved
INSTALL VALVE ON S/S GENERATOR SEA CHEST BEFORE FLEXIBLE HOSE.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Lifesaving
Issued 3 September 1985 Resolved
PASSENGER CARRYING CAPACITY IS REDUCED TO 47 UNTIL 4 ADDITIONAL APPROVED ADULT LIFE JACKETS ARE PLACED ABOARD.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Fire Fighting
Issued 3 September 1985 Resolved
CONDUCT ANNUAL INSPECTION OF FIRE EXTINGUISHERS (FIXED AND PORTABLE)
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.