Records from 1985 to 1999. Most recent: inspection, 29 June 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
29 June 1999
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1080482
7 January 1997
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1098015
3 January 1997
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1105944
12 December 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 135425
1 July 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1454322
24 April 1996
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1089861
13 December 1993
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 849493
17 September 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1265709
22 August 1991
COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1252915
26 February 1990
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1214877
16 January 1990
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 914276
12 October 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1341219
12 September 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1203233
6 October 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1196219
9 September 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1041772
21 May 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1331717
23 December 1986
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1335160
3 September 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1316701
20 May 1986
Credit Drydock
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 996540
6 September 1985
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 989654
3 September 1985
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1296694
Accommodation/Occupational Safety
Issued 22 August 1991
Resolved
REPAIR TWO BROKEN WINDOWS, LOCATED STBD AFT AND PORT FWD.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Lifesaving
Issued 22 August 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Navigation
Issued 22 August 1991
Resolved
OBTAIN AND INSTALL PROPER BULBS IN NAV RUNNING LIGHTS.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Fire Fighting
Issued 22 August 1991
Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Fire Fighting
Issued 12 September 1989
Resolved
INSTALL REMOTE ACTIVATION SYSTEM AND ALARMS FOR FIXED HALON SYSTEM IN ENGINE AND GENERATOR ROOMS.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
INSTALL APPROVED FITTINGS ON STARBOARD GENERATOR FUEL LINES.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
PROVIDE EMERGENCY BATTERY DISCONNECT SWITCH FOR ALL BATTERIES.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Construction/Loadline
Issued 12 September 1989
Resolved
AT NEXT DRYDOCK, REMOVE UNUSED 1/2" PIPE, MID SHIP COMPARTMENT THRU HULL FITTING.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989
Resolved
SECURE GENERATOR BATTERY BOXES FROM SHIFTING.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Fire Fighting
Issued 12 September 1989
Resolved
PROPERLY MOUNT ALL FIRE EXTINGUISHERS
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Accommodation/Occupational Safety
Issued 12 September 1989
Resolved
PROVIDE CERTIFIED MSD. TOILETS TO BE SECURED UNTIL COMPLETED. VOYAGE DURATION LIMITED TO 30 MIN UNTIL MSD INSTALLED.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Engineering
Issued 12 September 1989
Resolved
PROVIDE PLAME SCREENS IN ALL FUEL TANK VENTS
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Accommodation/Occupational Safety
Issued 12 September 1989
Resolved
PROVIDE INSECT SCREENS IN ALL POTABLE WATER TNAK VENTS
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Lifesaving
Issued 9 September 1988
Resolved
PROVIDE DISTRESS FLARES AND WATERPROOF CONTAINER. 46 CFR 180.35
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Construction/Loadline
Issued 9 September 1988
Resolved
REMOVE ALL PLASTIC THROUGH-HULL FITTINGS AND REPLACE WITH MELTALLIC FITTINGS. 46 CFR 182.40-1(E)
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Accommodation/Occupational Safety
Issued 9 September 1988
Resolved
INSTALL INSECT SCREEN IN PORTABLE WATER VENT.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Accommodation/Occupational Safety
Issued 9 September 1988
Resolved
REPAIR/REMOUNT AIR CONDITIONING CIRCULATION PUMP.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Electrical
Issued 9 September 1988
Resolved
PROVIDE GUARD FOR GENERATOR BELT DRIVES. 46 CFR 177.35-15.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Engineering
Issued 9 September 1988
Resolved
REMOVE SHIP'S STORES INWAY OF FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Documentation
Issued 9 September 1988
Resolved
POST STABILITY LETTER. 46 CFR 185.12
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Accommodation/Occupational Safety
Issued 9 September 1988
Resolved
INSTALL RAILING IN MAIN LOUNGE FOR 2 STEPS BEHIND STEERING STATION.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Fire Fighting
Issued 9 September 1988
Resolved
PROVIDE PROPER NOZZLE FOR FIRE HOSE. 46 CFR 181.15-10(E)
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 9 September 1988
Resolved
PROVIDE 15 ADULT LIFE PRESERVERS. PASSENGER CAPACITY REDUCED TO 36.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Fire Fighting
Issued 9 September 1988
Resolved
SERVICE HALON SYSTEMS.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 3 September 1986
Resolved
MARK VESSELS NAME ON ALL LIFE JACKETS.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Fire Fighting
Issued 3 September 1986
Resolved
MAKE PERMANENT REPAIRS TO LEAK IN THE FIREMAIN LOCATED ON CENTER LINE IN ENGINE COMPARTMENT
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Fire Fighting
Issued 3 September 1986
Resolved
CONDUCT ANNUAL SERVICING ON ALL PORTABLE AND FIXED FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Electrical
Issued 3 September 1986
Resolved
PROVIDE COVER FOR ELECTRICAL BOX LOCATED IN FORWARD COMPARTMENT, PORT SIDE.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Lifesaving
Issued 3 September 1985
Resolved
REPLACE ATTATCHMENT LINE TO RING LIFEBOUY LIGHT.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Electrical
Issued 3 September 1985
Resolved
INSTALL BATTERY COVERS ON ALL BATTERIES.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Documentation
Issued 3 September 1985
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Lifesaving
Issued 3 September 1985
Resolved
MARK ALL LIFE JACKETS WITH VESSELS NAME.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Fire Fighting
Issued 3 September 1985
Resolved
INSTALL FIRE AND BILGE PUMP AND TEST OPERATION.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Lifesaving
Issued 3 September 1985
Resolved
REPLACE HAND LINE ON RING LIFE BOUY.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Electrical
Issued 3 September 1985
Resolved
REMOVE PARTY LIGHTS ON UPPER DECK.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Construction/Loadline
Issued 3 September 1985
Resolved
INSTALL VALVE ON S/S GENERATOR SEA CHEST BEFORE FLEXIBLE HOSE.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Lifesaving
Issued 3 September 1985
Resolved
PASSENGER CARRYING CAPACITY IS REDUCED TO 47 UNTIL 4 ADDITIONAL APPROVED ADULT LIFE JACKETS ARE PLACED ABOARD.
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985
Fire Fighting
Issued 3 September 1985
Resolved
CONDUCT ANNUAL INSPECTION OF FIRE EXTINGUISHERS (FIXED AND PORTABLE)
Condition: Unknown
Due 3 September 1985
Resolved 3 September 1985