MAURY USCG vessel records Sign in
← All vessels

SKY SINO

SKY SINO is a 1998 tank ship. The Coast Guard has recorded 17 inspections since 1998, most recently in July 2009, along with 9 deficiencies and 6 operational controls.

Records from 1998 to 2009. Most recent: inspection, 10 July 2009.

Built
1998
Last inspected
10 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9187681 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
485080
Flag
MALAYSIA
—
Maury page id
psix-485080

Inspections, by type

…with no type recorded10
Years with a record 8 calendar years (1998–2009)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11955 - Convention (Subpart B), Net Ton
29965 - Convention (Subpart B), Gross Ton
45374 - Dead Weight, Ton
57609 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

10 July 2009 COC-CHEM Renew · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3520565
4 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3261638
16 June 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3239059
11 June 2008 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3234077
29 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2977907
13 March 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2887293
13 March 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2887319
11 February 2007 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew · MARPOL Annex II Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2870183
23 March 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2029803
14 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2026030
16 July 2003 Letter of Compliance (Initial/Renewal) · MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1839316
12 March 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 275695
12 March 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1047897
28 April 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 428060
6 April 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 427298
30 October 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 422173
30 October 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 805112

Deficiency record · 9

Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 11 June 2008 Resolved
Crew was unable to demonstrate proper calibration of or proper operation of the portable gas detectors. Display was showing an in-accurate reading with regard to the span gas it was reading.
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 16 June 2008
Resolution: Received technician''s report attesting to the proper repair and satisfactory testing of portable gas detector.
Engineering › Steering Gear System
Issued 16 July 2003 Resolved
Prove proper operation of the low an low/low steering gear hydraulic oil level alarms on the bridge. #1 and #2 steering pumps. To be completed to the satisfaction of the Class Society Surveyor prior to 31JUL03. LEGACY COMPONENT DESC: Low Oil Level Alarm Bridge
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 17 July 2003
Resolution: Deficiency was caused by faulty electrical wiring. Boarding team attested to proper functioning of alarms on 07/17/2003.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System
Issued 16 July 2003 Resolved
Replace the missing valve handle on the foam cannon in-way-of #7 cargo tank vents. Master to provide statement attesting to repairs. LEGACY COMPONENT DESC: Operation Controls
Condition: Improper/Lack of Maintenance
Due 20 July 2003
Resolved 17 July 2003
Resolution: Boarding team witnessed repairs to the valve handle on 07/17/2003.
Deck/Cargo › Cargo Stowage
Issued 16 July 2003 Resolved
Replace the the flame screens that have been partially painted for cargo tank vents, 4 P&S, 7 P&S. Master had replaced before boarding was complete. LEGACY COMPONENT DESC: P/V Flame Screens
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2003
Lifesaving › Embarkation Appliances/Stations
Issued 16 July 2003 Resolved
Replace worn port aft outboard davit brake release cable. Master had replaced. LEGACY COMPONENT DESC: Remote brake release
Condition: Improper/Lack of Maintenance
Due 16 July 2003
Resolved 16 July 2003
Deck/Cargo
Issued 12 March 2000 Resolved
PROVE PROPER OPERATION OF #8 PORT CARGO TANK HIGH LEVEL ALARM.
Condition: Unknown
Due 12 March 2000
Resolved 31 March 2000
Documentation
Issued 30 October 1998 Resolved
HAVE CLASSIFACTION SOCIETY EDIT VESSEL'S VCS LIST OF CARGOES AUTHORIZED FORVAPOR CONTROL, REMOVE ALL CARGOES NOT LISTED ON VESSEL'S CERTIFICATE OF FITNESS FOR CHEMICAL. PROVIDE LOCAL COAST GUARD WITH COPY NO LATER THAN 30NOV 98.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Documentation
Issued 30 October 1998 Resolved
AMEND INERT GAS MANUAL TO INCLUDE VAPOR CONTROL SYSTEM INFORMATION / INSTRUCTIONS. PROVIDE LOCAL COAST GUARD WITH SATISFACTORY CLASSIFICATION SOCIETY SURVEYOR'S REPORT NO LATER THAN 30 NOV 98.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Deck/Cargo
Issued 30 October 1998 Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF VSL'S DRAFT & TRIM LEVEL SYSTEM_x001C_TO SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL COAST GUARD WITH SATISFACTORY SURVEYOR'S REPORT. DATA FROM UNIT NOT TO BE USED FOR CARGO / NAVIGATION UNTIL CORRECTED.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.