BEDFORD CASTLE is a 1998 freight ship. The Coast Guard has recorded 12 inspections since 2017, most recently in January 2024, along with 18 deficiencies — 3 with no resolution recorded — and 4 operational controls.

Records from 2017 to 2024. Most recent: inspection, 25 January 2024.

Built
1998
Last inspected
25 January 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 January 2024
…with no type recorded5
…past their stated due date3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9189926
3E5122
485103
Flag
PANAMA
Maury page id
psix-485103

Documentation record

Tonnage as PSIX records it29688 - Convention (Subpart B), Gross Ton
15595 - Convention (Subpart B), Net Ton
50655 - Dead Weight, Ton
61213 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

25 January 2024 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7855403
18 January 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7850878
25 October 2023 Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7812064
13 December 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7608341
3 August 2022 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7524217
24 June 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7486339
22 June 2022 PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7483762
20 June 2022 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7482790
19 June 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7481526
8 March 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7591979
20 June 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6177866
19 June 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6181031

Deficiency record · 18

09 - Working and Living Conditions › 091 - Living Conditions › Provisions quantity
Issued 18 January 2024 Resolved
THE SECRETARY MAY ORDER ANY VESSEL, IN A PORT OR PLACE SUBJECT TO THE JURISDICTION OF THE UNITED STATES OR IN THE NAVIGABLE WATERS OF THE UNITED STATES, TO OPERATE OR ANCHOR IN A MANNER THE SECRETARY DIRECTS IF - BY REASON OF WEATHER, VISIBILITY, SEA CONDITIONS, PORT CONGESTION, OTHER HAZARDOUS CIRCUMSTANCES, OR THE CONDITION OF SUCH VESSEL, THE SECRETARY IS SATISFIED SUCH DIRECTION IS JUSTIFIED IN THE INTEREST OF SAFETY. SHIPS SHALL HAVE ON BOARD FOOD AND WATER SUPPLIES WHICH, HAVING REGARD TO THE SIZE OF THE CREW AND THE DURATION AND NATUAE OF THE VOYAGE, ARE SUITABLE IN RESPECT OF QUANTITY, NUTRITIVE VALUE, QUALITY AND VARIETY. PSCO OBSERVED SPOILED FOOD IN THE MEAT AND FISH STORES, AND THE VEGETABLE STORES WERE EMPTY. PWSA, 46 USC 70002 (3) ILO-147 (PG.30 - PARA 2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2024
Resolved 25 January 2024
Resolution: IN-SERVICE EXAM CONDUCTED.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 January 2024 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed the smoke detector above the ships service generators disconnected from the mounting and covered with a shirt. 74 SOLAS (14) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 February 2024
Resolved 24 January 2024
Resolution: Defective smoke detector fitted above ships service generator was replaced with new spare and tested with satisfactory result. All other fire detectors were tested with satisfactory result.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 January 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed water dripping from light and wire fixtures in the accommodation area. 74 SOLAS (04) II-1/40.1.3
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 February 2024
Resolved 24 January 2024
Resolution: Two corroded and leaking drain pipes in accomodation area were renewed (total 360cm in length). Found no water leaking from the water drain pipes.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 18 January 2024 No resolution recorded
THE MASTER, OWNER, OPERATOR OR PERSON IN CHARGE OF ANY VESSEL EQUIPPED WITH BALLAST WATER TANKS THAT OPERATES IN THE WATERS OF THE UNITED STATES MUST REMOVE FOULING ORGANISMS FROM THE VESSELS HULL ON A REGULAR BASIS ANO DISPOSE OF ANY REMOVED SUBSTANCES IN ACCORDANCE WITH LUCIL, STATE, AND FEDERAL REGULATIONS. PSCO OBSERVED EXCESSIVE GROWTH OF FOULING ORGANISMS ON BOTH PORT AND STARBOARD SIDE OF VESSEL'S HULL, AS WELL AS ON THE STERN. 33CFR151.2050(f)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 February 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 January 2024 No resolution recorded
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED MINOR HYDRAULIC LEAK ON THE STARBOARD MOORING WINCH ON THE POOPDECK. THE WINCH AND SURROUNDING AREA HAD STANDING HYDRAULIC OIL AND IS WRAPPED WITH CLOTH TO PREVENT FURTHER LEAK. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 February 2024 — due date passed with no resolution recorded
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 25 October 2023 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known. The nature of the below deficiencies provides objective evidence of a serious failure of the implementation of the ISM Code. An external ISM audit report, satisfactory to the Coast Guard, must be submitted prior to clearance of this deficiency and departure. 74 SOLAS (20) IX/3.1 ISM Code Part A/10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 November 2023
Resolution: Vessel submitted successful completed ISM audit.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 25 October 2023 Resolved
The siting and installation of accumulator batteries which provide a reserve source of energy shall be such as to ensure reasonable safety. PSCO's observed a large hole on the starboard side bulkhead of the space containing the GMDSS reserve accumulator batteries. This hole presents an unsafe environment for the batteries due to the ability of rain and moisture to negatively impact the condition of the batteries. 74 SOLAS (20) IV/13.7.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2023
Resolution: PSCOs observed the flap repaired and able to close properly
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 October 2023 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors...and weathertight when closed. PSCO's observed that both the port and starboard exterior doors on Deck A of the superstructure were not weathertight due to light being visible from the inside. ICLL (66) Reg. 12.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 November 2023
Resolution: PSCOs verified exterior doors are able to be sealed weathertight
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 October 2023 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. PSCO's observed that port side door on the forecastle was not weathertight due to light being visible from the inside. ICLL (66) Reg. 16.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 November 2023
Resolution: PSCOs verified door is able to be sealed weathertight
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2023 Resolved
Hydraulic power-operated steering gear shall be provided with arrangements to maintain the cleanliness of the hydraulic fluid taking into consideration the type and design of the hydraulic system. During the operational test, PSCO's observed a leak emanating from the No. 1 steering gear pump. 74 SOLAS (04) II-1/29.12.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2023
Resolution: PSCOs performed a functional steering test with no leak observed
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 25 October 2023 Resolved
In all ships a duplicate set of fire control plans or a booklet containing such plans shall be permanently stored in a prominently marked weather-tight enclosure outside the deckhouse for the assistance of shoreside fire-fighting personnel. PSCO's observed that the enclosure for the fire control plan located on the starboard side was seized shut. 74 SOLAS (97) II-2/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 November 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 August 2022 No resolution recorded
After any survey of the ship under regulations 7,8,9 or 10 has been completed, no change shall be made in the structural arrrangements, machinery,equipment and other items covered by the survey, without sanction of the administration. During cargo operations, the operators housing detached from the crane turret, resulting in injury to the operator. Crane found to be inoperable due to the disconnected operators housing. Cargo Operations are suspended until class surveyor verifies remaining cranes are functionally serviceable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2022 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 22 June 2022 Resolved
To discharge ballast water into the waters of the United States, the master, owner, operator, agent, or person in charge of a vessel subject to 151.2025 of this subpart must wither ensure that the ballast water meets the ballast water discharge standard in 151.2030(a), use an AMS as described in 151.2025(a)(3), or ballast with water from a US public water system, according to the schedule in paragraph (b) of this section. Subject vessel, of keel laid date 10MAR1998 and ballast water capacity of 26375.1m3, is past its compliance date per the implementation schedule in 33 CFR 151.2035(b). Vessel's current ballast water management method is exchange and discharge, which is not authorized. Vessel has no BWTS installed. Vessel is not authorized to discharge untreated ballast water into US waters. THis deficiency will not be cleared until USCG examiners receive documentation that the vessel has installed a BWTS, has decided to use only public water from the US public water system, or has updated its ballast water management plan to state that the vessel's ballast water management method in US waters is no discharge. During review of BWMP, PSCO observed that the plan did not include necessary provisions listed in 33 CFR 151 Subpart D.
Action required: 15 - Rectify deficiencies by next port
Due 29 June 2022
Resolved 12 July 2022
Resolution: Provided updated BWM Plan.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 June 2022 Resolved
Hydraulic power-operated steering gear shall be provided with the following: a fixed storage tank having sufficient capacity to recharge at least one power actuating system including the resivoir, where the main steering gear is required to be power-operated. Observed insufficient oil level of fixed storage tank for the steering gear.
Action required: 10 - Deficiency Rectified
Due 22 June 2022
Resolved 22 June 2022
Resolution: Crew rectified deficiency prior to PSC departure.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 20 June 2017 Resolved
The C/O, 2/O, and 3/E did not possess appropriate flag state endorsements, nor applications for the same on board. STCW Ch I/Reg I/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2017
Resolved 20 June 2017
Resolution: The crew missing endorsements were able to recieve their applications or apply for the endorsement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 June 2017 Resolved
03 "A-60" boundary self-closing doors in the engine room were found with hooks as hold-backs. 74 SOLAS (97) Ch. II-2/47.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel removed the hold back hooks from doors.
Deck/Cargo › Cargo Stowage › General
Issued 20 June 2017 Resolved
Doors required to be self-closing shall not be fitted with hold back hooks. PSCO found 03 "A-60" boundary self-closing doors with hooks as hold back mechanisms in the engine room. 74SOLAS(97 ED) CH II-2/ 47.2 10c
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel found the approved cargo securing manual.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 20 June 2017 Resolved
No person may use any hose in under water service for transfer operations unless the operator of the vessel has tested and inspected as applicable. Vessel's chief engineer was not able to provide proof of hydrostatic test being conducted. 33CFR156.170(d). 10c.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel found proper hydrostatic test for their bunker lines.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.