MAURY USCG vessel records Sign in
← All vessels

ONE LOVE

ONE LOVE is a 1959 freight ship. The Coast Guard has recorded 11 inspections since 1999, most recently in February 2003, along with 112 deficiencies and 9 operational controls.

Records from 1999 to 2003. Most recent: operational control imposed, 19 February 2003.

Built
1959
Last inspected
19 February 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5020861 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CPB620
485106
Flag
BOLIVIA
—
Maury page id
psix-485106

Inspections, by type

…with no type recorded8
Years with a record 5 calendar years (1999–2003)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it318 - Convention (Subpart B), Net Ton
318 - Regulatory (Subpart C or D), Net Ton
570 - Convention (Subpart B), Gross Ton
499 - Regulatory (Subpart C or D), Gross Ton
800 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

19 February 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1696997
24 October 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1695453
12 September 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1674588
29 March 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1598960
27 January 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 283445
25 October 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 283444
3 April 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 637727
15 March 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 274875
20 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 435957
14 May 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428722
28 January 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 423949

Deficiency record · 112

Deck/Cargo › Cargo Stowage
Issued 21 March 2003 Resolved
Remove all hazardous materials (paints, batteries) or provide Dangerous Cargo Manifest and crew HAZMAT training. IAW 49 CFR 171-179.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2003
Deck/Cargo › Cargo Stowage
Issued 21 March 2003 Resolved
Remove cargo (non-flammable paints) from ships paint/flammable locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2003
Deck/Cargo › Cargo Stowage
Issued 21 March 2003 Resolved
Remove old anchor chain (cargo) from foscle so crew can access safely.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2003
Documentation › Certificates/Documents
Issued 21 March 2003 Resolved
Have Flag State address manning requirements under manning complement found on Ships Registry. Currently manning does not address proper rest periods IAW STCW. LEGACY COMPONENT DESC: Minimum Safe Manning Document
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2003
Construction/Loadline › Structures
Issued 25 November 2002 Resolved
Door and frame to paint locker wasted and missing gasket. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Door
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Stability › Weathertight Integrity
Issued 18 November 2002 Resolved
Bridge window broken. Make permanent and proper repairs to satisfaction of Flag State Rep. and provide report to this USCG Office.
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Electrical › Electrical Distribution System (service)
Issued 18 November 2002 Resolved
The main switchboard has a broken fuse and no electrical matting. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Switchboard
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Electrical › Electrical Distribution System (service)
Issued 18 November 2002 Resolved
Dead end cables and poor wiring connections in back of main switchboard. Remove or properly terminate wires in a box, to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Electrical › Electrical Distribution System (service)
Issued 18 November 2002 Resolved
Dead end cables, broken fixtures and missing covers throughout the engine. Remove or properly terminate wires in a box, to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Cable
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Fire Fighting › Structural - A Class Divisions
Issued 18 November 2002 Resolved
Holes wasted in overhead to engine room. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Engineering › Sea-water System (primary cooling)
Issued 18 November 2002 Resolved
Hole wasted in main seawater piping, survey piping and make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Pollution Prevention/Response › Prevention Equipment
Issued 18 November 2002 Resolved
Remove plastic hose from main seawater line to Oily Water Separator and make permanent and proper repairs to the satisfaction of the Flag State REp. and provide report to this USCG Office. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 21 January 2003
Engineering › Sea-water System (primary cooling)
Issued 18 November 2002 Resolved
Main seawater valve is missing handle and has wasted bolts. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Valve
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Fire Fighting › Fire Main
Issued 18 November 2002 Resolved
Improper fitting, poor weldign and doulbers on the fire main. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Electrical › Electrical Distribution System (service)
Issued 18 November 2002 Resolved
Improper wiring, exposed wiring and missing cover to the 220 generators and batteries. Make permanent and proper repairs to the satisfaction of the Flag State REp. and provide report to this USCG Office. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Engineering › Freshwater System (intermediary cooling)
Issued 18 November 2002 Resolved
Freshwater cooling to main diesel engine holed and wasted. Make permanent and proper repairs to the satisfaction fo the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 18 November 2002 Resolved
Dead end wiring, exposed wiring and missing covers on Main Diesel and Auxiliary equipment. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office.
Action required: 705 - Other - as specified
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Accommodation/Occupational Safety › Washroom/Toilet
Issued 18 November 2002 Resolved
Toilets and sewage system not working prperly, heads un-sanitary. Remove or replace hoses, wasted and holed piping in the engine room and in heads, ensure the proper number of heads are cleaned and working. Prove proper operation of the entire system to the satisfaction of the USCG attending M.I. LEGACY COMPONENT DESC: Toilet
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Engineering › Steering Gear System
Issued 18 November 2002 Resolved
Dead end wiring, exposed wiring and missing covers on steering gear. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Engineering › Steering Gear System
Issued 18 November 2002 Resolved
Steering gear needs to be permanently and properly marked with rudder angels to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Electrical › Electric Supply System (service)
Issued 18 November 2002 Resolved
Dead cables and improperly maintained batteries. Make permanent and proper repairs to the satsifaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Accommodation/Occupational Safety › Occupational Safety
Issued 18 November 2002 Resolved
Dead end wires, exposed wires, and broken fixtures throughout the accommodations. Make permanent and proper repairs to the satisfaction fo the Falg State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Receptacle Outlet
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Accommodation/Occupational Safety › Occupational Safety
Issued 18 November 2002 Resolved
Remove un-approved hot plate from mess deck area, to the satisfaction fo the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Operations/Management › Drills/Instruction
Issued 18 November 2002 Resolved
Provide safety placards and instructions in the language of the vessel or English to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Safety Orientation
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Accommodation/Occupational Safety › Messroom
Issued 18 November 2002 Resolved
Galley and food stores unacceptable sanitary condition. Clean and sanitize the galley, mess deck and storerooms tot he satisfaction of the attending USCG Marine Inspectot
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Construction/Loadline › Structures
Issued 18 November 2002 Resolved
Door, doorframe, and bulkhead wasted and holed at the aft entrance to the galley. make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Door
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Accommodation/Occupational Safety › Occupational Safety
Issued 18 November 2002 Resolved
Ladder for aft deck to 01 deck wasted and dangerous. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office.
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Electrical › Electric Generation Source (service)
Issued 18 November 2002 Resolved
Generator added on 01 deck is exposed to the weather. Prove proper installation. Provide approved plans and survey from Flag State Rep. and provide report to this USCG Office.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 21 January 2003
Electrical › Electric Supply System (service)
Issued 18 November 2002 Resolved
Batteries laying about on flying bridge and 01 deck. Replace batteries as needed. Remove unused batteries and properly dispose of them to the satisfaction of the Flag State Rep. Provide receipt of disposal to this USCG Office. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Lifesaving › Launching Appliances
Issued 18 November 2002 Resolved
Rescue boat cradle wasted. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Construction/Loadline › Hull
Issued 18 November 2002 Resolved
Rivets weeping seawater throughout main hold. Remove epoxy, paint and rust so that the Flag State Rep. may conduct a proper survey of the rivets and provide report to this USCG Office. LEGACY COMPONENT DESC: Hull Plating
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Electrical › Electric Generation Source (emergency)
Issued 18 November 2002 Resolved
Emergency generator inoperative. Make permanent and proper repairs and prove proper operation of said generator under load. Ensure generator can provide the proper power to the required equipment to the satisfaction fo the Flag State Rep. and provide report to this USCG Office.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Fire Fighting › Miscellaneous Items
Issued 18 November 2002 Resolved
Paint locker has open containers and improper explosion proof lighting fixture. Make permanent and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Construction/Loadline › Structures
Issued 18 November 2002 Resolved
Overhead in head below galley wasted and leaking water from galley above. make permanent and proper repairs to the satisfaction of the Falg State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Superstructure
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Accommodation/Occupational Safety › Occupational Safety
Issued 18 November 2002 Resolved
Lighting in engine room inadequate and improper. make permnaent and proper repairs to the satisfaction of the Flag State Rep. and provide report ot this USCG Office. LEGACY COMPONENT DESC: Lighting in Engine Room
Due 15 December 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Lifesaving › Lifebuoys
Issued 18 November 2002 Resolved
Lifebuoys are not properly labeled, missing reflective tape and/or proper line throughout the vessel. Make permanenet and proper repairs to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Personnel › Manning/Qualifications
Issued 18 November 2002 Resolved
Provide proper and valid licenses for crew sailing on the vessel prior to vessel departing the Port of Miami. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 21 January 2003
Documentation › Certificates/Documents
Issued 18 November 2002 Resolved
Provide proper and valid required certificates prior to departing the Port of Miami. (Including life raft and fire extinguishing service) LEGACY COMPONENT DESC: All Certificates, Documents, & Manuals
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 21 January 2003
Operations/Management › Drills/Instruction
Issued 18 November 2002 Resolved
Conducte proper fire, steering, and rescue boat drills. LEGACY COMPONENT DESC: Fire, Abandon Ship, and Steering
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 21 January 2003
Construction/Loadline › Structures
Issued 18 November 2002 Resolved
Many areas of the main cargo deck appear to be wasted and extremely thin, provide report from Flag State Rep Surveyor to include gagging of said deck area along sied the combings port and stbd side froward. Vessel to conduct light and or water test of main deck at next inspection. LEGACY COMPONENT DESC: Deck Plating
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Stability › Watertight Integrity
Issued 24 October 2002 Resolved
Make permanent repairs to wasted gooseneck on forepeak. LEGACY COMPONENT DESC: Gooseneck
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Fire Fighting › Fire Main
Issued 24 October 2002 Resolved
Properly repair fire main where holed on deck and patched in engineroom. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Fire Fighting › Fire Hoses
Issued 24 October 2002 Resolved
Replace holed fire hose on main deck. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Fire Fighting › Structural Fire Protection - General
Issued 24 October 2002 Resolved
Make proper repairs to areas of free communication between engine room and accomadation spaces. LEGACY COMPONENT DESC: Accommodation Space Protection
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Electrical › Electrical Distribution System (service)
Issued 24 October 2002 Resolved
Provide permanent wiring throughout vessel in place of all spliced extension cords and exposed wires. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Operations/Management
Issued 24 October 2002 Resolved
Complete annual CCSSC exam conducted by USCG inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Fire Fighting › Combustible Materials
Issued 24 October 2002 Resolved
Paint buckets, rags, spare partsw throughou engine room causing a fire and safety hazard. Remove and clean up engine room to the satisfaction of the Flag State Rep. and provide report to this USCG Office. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 17 December 2002
Resolution: Cleared on board 12/17/02
Pollution Prevention/Response › Prevention Equipment
Issued 24 October 2002 Resolved
Prove proper operation of the oily water seperator. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Electrical › Electric Generation Source (service)
Issued 24 October 2002 Resolved
New Enclosure for generator is not adequate, plans were note submitted prior to installation as required in item# 24. Enclosure must be large enough to allow work to be conducted in a protected space. Installation must be in accordance with Part F of the Code and proper operations must be proven LEGACY COMPONENT DESC: Generator
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Electrical › Electrical Distribution System (service)
Issued 24 October 2002 Resolved
Electrical installation in the engine room is still not proper and shorted out during the "Follow up Inspection". Prove proper operation of both main generators and remove or properly terminate all dead wires.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Electrical › Electric Generation Source (service)
Issued 24 October 2002 Resolved
Provide safety guard around generator set for the electrical wiring and the starter assembly.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: Cleared on board.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 October 2002 Resolved
Repair safety rail and chain aft of rescue boat. LEGACY COMPONENT DESC: Lifeline
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 January 2003
Resolved 21 January 2003
Resolution: Cleared on board.
Fire Fighting › Combustible Materials
Issued 24 October 2002 Resolved
Remove or properly stow all propane tanks on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: Cleared on board.
Construction/Loadline › Structures
Issued 24 October 2002 Resolved
Repair hole in paint locker bulkhead leading to emergency generator space. LEGACY COMPONENT DESC: Superstructure
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: Cleared on board.
Electrical › Electric Generation Source (emergency)
Issued 24 October 2002 Resolved
Prove proper installation and operation of the emergency generator under load with bridge equipment on line LEGACY COMPONENT DESC: Generator
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: Cleared on board.
Fire Fighting › International Shore Connection
Issued 24 October 2002 Resolved
Provide a proper international fire main shore connection.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: ISC provided, cleared on board.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 October 2002 Resolved
Remove or replace wasted deck box on 01 deck LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: Cleared on board.
Construction/Loadline › Structures
Issued 24 October 2002 Resolved
Hatch cover outside of galley wasted and will not close properly, make permanent and proper repairs to the satisfaction of the attending USCG inspector. LEGACY COMPONENT DESC: Scuttle
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: Cleared on board.
Personnel › Manning/Qualifications
Issued 24 October 2002 Resolved
Provide a 2nd licensed engineer prior to departure. LEGACY COMPONENT DESC: Minimum Safe Manning
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2003
Resolution: 2nd Engineer provided.
Personnel › Manning/Qualifications
Issued 24 October 2002 Resolved
Provide medical certificates and licenses for all crew sailing this voyage. Prior to sailing. LEGACY COMPONENT DESC: Medical Fitness
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2003
Resolution: Medical and docs provided for all crew.
Operations/Management › Drills/Instruction
Issued 24 October 2002 Resolved
Conduct proper drills with crew sailing on this voyage prior to departing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2003
Resolution: Drills completed to satisfaction.
Electrical › Electric Generation Source (emergency)
Issued 24 October 2002 Resolved
Properly install fuel cut off valve on emergency generator prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2003
Resolution: Fuel cut off valve properly installed.
Electrical › Electric Supply System (service)
Issued 24 October 2002 Resolved
Remove or properly terminate dead end cabel next to sewage tank in engine room prior to departing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2003
Resolution: Dead end wires properly terminated.
Electrical › Electric Generation Source (service)
Issued 24 October 2002 Resolved
Properly install and have class approve installation of main generator in engine room. Now located on deck. Not later than 16FEB03.
Due 16 February 2003
Resolved 21 March 2003
Pollution Prevention/Response › Prevention Equipment
Issued 24 October 2002 Resolved
DO NOT USE oily water seperator until properly installed and approved by class and US Coast Guard. Provide receipt for any oil discharged ashore. Repairs to be completed no later than 16FEB03. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Due 16 February 2003
Resolved 21 March 2003
Personnel › Certificates/Documents/Licenses › License, Master
Issued 29 March 2002 Resolved
Man vessel in accordance with Minimum Safe Manning document, prior to departure.
Due 29 March 2002
Resolved 5 April 2002
Resolution: Reviewed Master''s license for Jesus J. Tasa Cervantes.
Deck/Cargo › Cargo Stowage
Issued 29 March 2002 Resolved
Cleare all cargo from #2 forward generator space, prior to departure.
Due 29 March 2002
Resolved 5 April 2002
Resolution: Cleared def.
Deck/Cargo › Cargo Stowage
Issued 29 March 2002 Resolved
Remove cargo from in and around anchor windlass, prior to departure.
Due 29 March 2002
Resolved 5 April 2002
Resolution: Cleared def.
Deck/Cargo › Cargo Stowage
Issued 29 March 2002 Resolved
Ensure bridge visiblity is in accordance with 33 CFR 164.15, remove cargo as needed.
Due 29 March 2002
Resolved 5 April 2002
Resolution: Cleared def.
Documentation
Issued 27 January 2001 Resolved
Update "International Load Line Certificate" to show correct expiration date. Fax copy to MSO Miami.
Condition: Unknown
Due 27 January 2001
Resolved 27 January 2001
Lifesaving
Issued 15 March 2000 Resolved
Noted excess oil on and around auxillary generator.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Documentation
Issued 15 March 2000 Resolved
Provide medical certificates for all members of the crew.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Navigation
Issued 15 March 2000 Resolved
Provided updated or corrected charts, lightlists, and tidal current tables.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Construction/Loadline
Issued 15 March 2000 Resolved
Replace gasket material on all cargo hold vertical access trunk covers including the access trunk on the foc'sle.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
Renew battery on 9Ghz SART.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
Prove proper operation of rescue boat IAW LSA code.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Engineering
Issued 15 March 2000 Resolved
Repair remote engine fuel cut-offs.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Fire Fighting
Issued 15 March 2000 Resolved
Demonstrate proper fire and abandon ship drill for U.S. Coast Guard inspector.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
Provide Class Society survey report attesting to successful completion of deficiencies 1-14 of this Boarding Report.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Documentation
Issued 15 March 2000 Resolved
VESSEL HAD HAZMAT ONBOARD AND HAD NO DCM. MUST PROVIDE DCM PRIOR TO DEPARTURE
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Fire Fighting
Issued 15 March 2000 Resolved
Correct fire control plan to indicate correct location of fire fighting equipment.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Deck/Cargo
Issued 15 March 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Fire Fighting
Issued 15 March 2000 Resolved
Demonstrate proper operation of main fire pump following repair.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Fire Fighting
Issued 15 March 2000 Resolved
Remove cap from fire main line providing protection to the paint locker.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Electrical
Issued 15 March 2000 Resolved
Replace missing light cover in the battery room, located in the aux steering compartment.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Engineering
Issued 15 March 2000 Resolved
Make permanent repair to main engine cooling water overboard discharge piping.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Documentation
Issued 15 March 2000 Resolved
Provide 2 GMDSS licensed personnel on board.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Documentation
Issued 15 March 2000 Resolved
VESSEL HAD HAZMAT ONBOARD AND CREW FAILED TO BE TRAINED AND HAVE RECORDS FOR HAZMAT TRAINING IAW 49 CFR._x001C_ MUST PROVIDE HAZMAT TRAINING FOR CREW OR DISCHARGE HAZMAT PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Fire Fighting
Issued 20 December 1999 Resolved
Service all expired fire extinguishers
Condition: Unknown
Due 20 December 1999
Resolved 13 January 2000
Lifesaving
Issued 20 December 1999 Resolved
provide a rescue boat & rescue boat's equipment
Condition: Unknown
Due 20 December 1999
Resolved 13 January 2000
Documentation
Issued 14 May 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 June 1999
Resolved 6 June 1999
Navigation
Issued 14 May 1999 Resolved
PRIOR TO DEPARTURE, INSTALL COMPLETE GMDSS EQUIPMENT.
Condition: Unknown
Due 6 June 1999
Resolved 6 June 1999
Documentation
Issued 14 May 1999 Resolved
PRIOR TO DEPARTURE, PROVIDE VALID CARGO SHIP SAFETY RADIO CERTIFICATE AND FORM R.
Condition: Unknown
Due 6 June 1999
Resolved 6 June 1999
Unknown
Issued 14 May 1999 Resolved
PRIOR TO DEPARTURE, HAND DELIVER TO MSO MIAMI PROOF OF COMPLIANCE WITH THE OUTSTANDING REQUIREMENTS.
Condition: Unknown
Due 6 June 1999
Resolved 6 June 1999
Navigation
Issued 28 January 1999 Resolved
Prior to departure provide emergency steering instructions in Spanish in aft steering.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Accommodation/Occupational Safety
Issued 28 January 1999 Resolved
Prior to departure provide discharge placard for sewage near sewage holdingtank.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Lifesaving
Issued 28 January 1999 Resolved
Provide muster list in Spanish prior to 15FEB99.
Condition: Unknown
Due 15 February 1999
Resolved 29 January 1999
Navigation
Issued 28 January 1999 Resolved
Prior to departure provide current navigation publications including U.S. Coast Pilot [name withheld], Light List, Tide and Current tables.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Navigation
Issued 28 January 1999 Resolved
Prior to 15FEB99 prove proper operation of the daylight signalling lamp.
Condition: Unknown
Due 15 February 1999
Resolved 29 January 1999
Navigation
Issued 28 January 1999 Resolved
Prior to 15FEB99 provide means of illuminating the magnetic compass.
Condition: Unknown
Due 15 February 1999
Resolved 29 January 1999
Electrical
Issued 28 January 1999 Resolved
Prior to 15FEB99 provide cover for light in starboard aft storeroom.
Condition: Unknown
Due 15 February 1999
Resolved 29 January 1999
Fire Fighting
Issued 28 January 1999 Resolved
Prior to departure repair and demonstrate proper working vent closure to engine room._x001C_
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Engineering
Issued 28 January 1999 Resolved
Prior to departure remove diesel from ballast tank and have ballast tank certified "clean" and addressed by Class/Flag.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Electrical
Issued 28 January 1999 Resolved
Prior to departure demonstrate emergency batteries taking load in the eventof a power loss and sustain power for 18 hours.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Documentation
Issued 28 January 1999 Resolved
Prior to departure paint loadline marking to reflect loadline certificate (freeboard mark).
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Documentation
Issued 28 January 1999 Resolved
Prior to departure paint deck reference mark in contrasting color to hull.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Lifesaving
Issued 28 January 1999 Resolved
Provide SOLAS training manual in Spanish prior to 15FEB99.
Condition: Unknown
Due 15 February 1999
Resolved 29 January 1999
Documentation
Issued 28 January 1999 Resolved
Prior to departure provide a current crew list.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Documentation
Issued 28 January 1999 Resolved
Prior to departure provide a licensed master.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Unknown
Issued 28 January 1999 Resolved
Vessel must provide all valid certificates and complete an Annual Freight Exam with MSO,prior to loading and departing.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Documentation
Issued 28 January 1999 Resolved
Prior to departure provide a licensed chief mate.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Engineering
Issued 28 January 1999 Resolved
Prior to next bunkering provide oil transfer procedures in Creole.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000

Ownership record