MAURY USCG vessel records Sign in
← All vessels

SEA QUEST II

SEA QUEST II is a 1975 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1981, most recently in July 2026, along with 98 deficiencies and 3 casualty investigations between 2010 and 2015.

Records from 1981 to 2026. Most recent: inspection, 13 July 2026.

Built
1975
Last inspected
13 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAR2745
Flag
UNITED STATES
368088290
Maury page id
psix-48511

Inspections, by type

…with no type recorded9
Years with a record 36 calendar years (1981–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS, INC · LOREAUVILLE LA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPLAINFIELD, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7836MMSI 368088290 · active · compulsorily equipped · granted 18 April 2019, expires 18 April 2029 · licensed under a name not among this hull’s recorded names (not shown)
WAR2745MMSI 366115000 · expired · compulsorily equipped · granted 12 January 2016, cancelled 11 April 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

13 July 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8437405
17 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8406655
12 June 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8161831
5 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8152645
9 May 2024 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7909130
6 May 2024 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7901469
27 June 2023 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7726639
31 May 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7701470
17 November 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7596151
1 July 2022 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7497471
6 April 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425989
16 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7288082
10 June 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7221122
10 June 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6974541
17 April 2019 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6664351
28 January 2019 Drydock Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6616246
5 April 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6375139
5 April 2017 Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6099405
21 March 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5837676
27 January 2016 Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5804338
8 August 2015 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5816034
11 March 2014 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4813776
3 June 2012 Type not recorded
No type recorded · USCGC VIGOROUS (WMEC 627) · Activity 4334039
20 September 2011 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4150111
1 August 2011 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4102185
18 March 2010 COI Inspection · DAPI Audit
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3697883
30 March 2009 Drydock Extension · Internal Structural Exam · DAPI Audit · Annual Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3449045
18 April 2008 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3185666
18 April 2007 Annual Inspection · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2909712
21 March 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2890590
1 February 2007 Drydock Extension
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2865571
11 April 2006 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2617600
22 April 2005 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2340499
28 February 2005 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2300663
14 April 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2048485
24 April 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1779851
10 February 2003 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1742328
29 April 2002 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1609654
8 November 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075681
20 April 2001 Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1462227
27 March 2001 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1462226
18 June 2000 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 169452
18 June 2000 Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 1514547
24 April 2000 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1444319
13 April 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1369164
15 March 1999 Deficiency Check · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1470203
7 April 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1123071
30 June 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 670351
26 June 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 215207
25 April 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1101269
4 April 1997 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1095255
18 March 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1101750
11 April 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1090132
28 March 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 833795
25 January 1995 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 830046
5 April 1994 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1169221
13 May 1993 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1146826
13 April 1993 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1150852
1 February 1993 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1140731
10 July 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 128871
14 April 1992 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1256785
4 February 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1259904
16 April 1991 COI Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 909163
21 June 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999471

Deficiency record · 98

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2026 Resolved
Each lifejacket carried on a vessel on a Great Lakes route must have a lifejacket light approved IAW 46 CFR 161.012. None of the Type I lifejackets have lights. Vessel is restricted to within 20-miles from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 June 2026
Resolution: Received photographic evidence of installation of life jacket lights.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 June 2026 Resolved
Each 406MHz EPRIB must be installed to float free. Hydrostatic release is expired. Vessel is restricted to within 3 miles from shore until cleared.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 June 2026
Resolution: Received photographic evidence of installation of hydrostatic release with expiration date marked June 2028.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2026 Resolved
A vessel must carry one floating waterlight. No floating waterlight is provided on board. Vessel is restricted to daylight operations until complete.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 July 2026
Resolution: Received photographic evidence of installation of floating waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 June 2026 Resolved
Each lifefloat must be secured to the painter on one end and the vessel at the other. The painter for one life float is not connected to the hydrostatic release.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 June 2026
Resolution: Master properly attached lifefloat painter to the hydrostatic releases.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 June 2026 Resolved
The vessel must carry adequate and up to date: 1. Charts 2. U.S. Coast Pilot 3. Coast Guard Light List. The charts and publications on board are not up to date.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2026
Resolved 23 July 2026
Resolution: Charts are added to the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 June 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 17 June 2026
Resolution: Discussed procedures for pre-employment testing of employees with owner.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 June 2026 Resolved
The owner, charterer, Master, or managing operator shall instruct each crew member upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months as to the duties the crew member is expectedto perform in an emergency. No record of crew training has been conducted.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 June 2026
Resolution: Discussed requirements for crew training with the owner/operator/Master.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2026 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. The bilge pipe for the fwd compartment is leaking into the #2 compartment.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 June 2026
Resolution: Received photographic evidence of installation of new coupling in #2 bilge void.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 June 2026 Resolved
A hatch exposed to the weather must be watertight. The gasket in way of the bow hatch is wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2026
Resolved 23 July 2026
Resolution: Hatch gasket replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 June 2026 Resolved
The hailing port of the vessel must be marked on some clearly visible exterior port of the stern of the vessel. The hailing port on the certificate of documentation is "Plainfield, IL" The hailing port on the stern is "Hammond, IN".
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 June 2026
Resolution: Received photographic evidence of proper hailing port on stern of vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2025 Resolved
Each floating water light must be approved in accordance with 46 CFR 161.010. The floating water light are provided with the incorrect batteries. Provide the batteries recommended by the manufacture.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 9 September 2025
Resolution: proper batteries installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2025 Resolved
Portable fire extinguishers must be inspected and maintained IAW NFPA 10. The two CO2 fire extinguishers onboard have not had a hose continuity test since 2022. Conduct continuity test. Test must be conducted by a certified technician.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 9 September 2025
Resolution: Test complete.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 June 2025 Resolved
A vessel on a oceans, coastwise, limited coastwise, or great lakes route must carry: (1) Six hand red flare distress signals and; (2) Six hand orange smoke distress signals. The vessel only has 03 red flare distress and 06 hand orange smoke distress signals.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 12 June 2025
Resolution: Flares added.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 June 2025 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or kit with equivalent contents and instructions. The vessels first aid kit has expired contents.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 9 September 2025
Resolution: kit installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2025 Resolved
At each inspection, the marine inspector shall examine the intake valves and determine they are in the proper operating condition and fit for the service intended. The flexible hose between the raw water intake valve and raw water filter in void #2 is worn. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2025
Resolved 12 June 2025
Resolution: hose replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2025 Resolved
Each bilge line shall be provided with a check valve at some accessible point in the bilge line. The threaded cover for the check valve in the #2 void bilge piping is missing. Replace the cover and prove proper operation of check valves in all bilge lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2025
Resolution: Valve cap installed and system tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2025 Resolved
Battery chargers must have an ammeter connected in the charging circuit. The battery charger mounted on the aft engine room bulkhead is not provided with an ammeter in the circuit. Provide the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 12 June 2025
Resolution: charger was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2025 Resolved
Fire hazards on board shall be minimized. The diesel fuel return line for the starboard main engine is leaking at the fuel cooler. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2025
Resolved 12 June 2025
Resolution: leak was repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2025 Resolved
The floating water light for the life float must be attached around the body of the life float by a 10mm (3/8) lanyard resistant to deterioration from ultra-violet light and at least 18 feet in length. The lanyard for the floating water light in way of the large life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 9 September 2025
Resolution: new line installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2025 Resolved
Each life float must be fitted with a painter. The painter must: Be at least 100ft in length, have a breaking strength of at least 1500 lbs, be of a dark color if synthetic, be stowed in such a way that it runs out freely when the life float floats away from a sinking vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 9 September 2025
Resolution: Painter added to vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 5 June 2025 Resolved
At each inspection, the toilet and washing spaces may be examined to determine they are in serviceable condition. The flexible hose between the sink and pvc pipe in the #2 void is missing the top most hose clamp and the flexible hose itself is deteriorated. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 12 June 2025
Resolution: pipe was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2025 Resolved
Propulsion machinery must be suitable in type and design for the propulsion requirements of the hull. The starboard main engine forward inboard motor mount is fractured. Make repairs to the same.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2025
Resolution: mount was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2025 Resolved
Propulsion machinery must be suitable in type and design for the propulsion requirements of the hull. The port main engine serpentine belt is worn. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2025
Resolution: Belt replaced on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 May 2024 Resolved
The life raft float free must be IAW 180.130 (a)(1) must be proper for size of raft. Add name of vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 30 May 2024
Resolution: New link installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 May 2024 Resolved
An exposed hazard, such as gears or rotating machinery must have guards. The engine driven fire pump has no guards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 14 June 2024
Resolution: Guard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2024 Resolved
Conduct maintenance of the main engines Air sep system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 7 June 2024
Resolution: airsep cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024 Resolved
Hydraulic oil found in the steering space. Determine cause and repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2024 Resolved
Crew using un-approved life vests for MOB. Install proper vest.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 25 July 2024
Resolution: Special Consideration letter routed for signature.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2024 Resolved
A vessel on a Great Lakes route must carry six hand held red flares, and six orange smoke distress signals. Vessel is only provided with 4-red and 3-orange distress signals. Provide correct amount of distress signals.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: proper number installed
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 6 May 2024 Resolved
Properly mount the on/off switch for the vessel's OTS, properly mount the radar wiring, and prove proper operation of the radar.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Radar all sat.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 6 May 2024 Resolved
Each vessel must be provided with a PA system. The PA system is only working intermittently. Prove proper operation of the PA system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: PA fuction tested, All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2024 Resolved
A vessel must carry adequeate & up to date charts of the intended area, light list, and coast pilot. Provide up to date copies of the all of the above on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2024 Resolved
A vessel must be provided with non-combustible waste receptacles. Remove plastic trash cans from the vessel and provide non-combustible waste receptacles.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: proper cans installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 May 2024 Resolved
A durable radio broadcast placard with information specific to the vessel must be posted. The posted broadcast placard does not have the vessel specific information completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: placard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024 Resolved
The valve handle in way of the overboard discharge in the forward space is broken. Make repairs to the same.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: valve handle replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024 Resolved
The flexible hose in way of the automatic bilge pump in the forward space is no secured to the overboard discharge. Properly secure the same.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Hose clamp tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024 Resolved
Prove proper operation of the automatic bilge pump in the forward space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Bilge pump tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024 Resolved
A vessel of less than 65ft carring not more than 49 passengers must be provided with a fixed power bilge pump. The bilge pump is inoperable. Prove proper operation of the same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: All suction points were tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2024 Resolved
The flexible hose in way of the A/C water intake is worn. Repair or replace the same.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: hose clamp added.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 May 2024 Resolved
At each inspection the owner must make life saving equipment available. Make both life floats available for inspection and ensure proper marking, eqipment and installation is complete as required.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: rafts inspected.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 May 2024 Resolved
The crew must be trained to the rquirements in 46 CFR 185.420 and conduct the drills required in 46 CFR 185.524 every three months. The training muste be logged and available for review.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Drills conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 31 May 2023 Resolved
Vessel EPIRB registration is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 9 June 2023
Resolution: Received NOAA Registration Card.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2023 Resolved
Two different style life jackets are on board. Install donning placard for both style jackets or remove different jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2023
Resolution: removed all non-standard jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 July 2022 Resolved
All onboard fire extinguisher have not been serviced and expired on 01JUL22. Replace or service prior to carrying passengers. Provide service report.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 July 2022
Resolution: Spares were provided by Fire Service Tech.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 1 July 2022 Resolved
Collision bulkhead water suction valve handle needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2022
Resolution: New handle installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 1 July 2022 Resolved
STBD Aft Pilot house window is cracked and needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 November 2022
Resolution: Window replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 July 2022 Resolved
Lifesaving and firefighting equipment inspections have not been logged or completed. Provide evidence that inspection program is developed and followed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2022
Resolution: Records of logs for month of july reviewed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 July 2022 Resolved
MOB and Fire Drills have not been completed for 2022. Conduct these drills with crews and provide 30 days of logs to MSU Chicago by 02AUG22
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2022
Resolution: records of logs reviewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2021 Resolved
Replace defective Ring Bouy.
Action required: 705 - Other - as specified
Due 10 June 2021
Resolved 10 June 2021
Resolution: Ring Bouy was extra and removed from Vessele
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 10 June 2021 Resolved
Renew Hydrostatic release for EPIRB. vessel route is restricted to 1 mile.
Action required: 705 - Other - as specified
Due 11 June 2021
Resolved 11 June 2021
Resolution: EPIRB temporary moved to a float free arrangement. New Hydro release has been ordered and will install and place EPIRB in a new location.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 June 2021 Resolved
Replace Discharge Hose of fire pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 24 June 2021
Resolution: Discharge Hose was replaced and tested
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2021 Resolved
Found 6 defective Adult Life Jackets. Reduced passenger count by 6, to 21 total persons
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2021
Resolved 16 August 2021
Resolution: Received photos of new life jeckets that are properly marked with name and retro tape
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 10 June 2020 Resolved
Installed weak links were not CG approved. vessel is limited to 3 miles from shore
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 11 June 2020
Resolution: Vessel Received brand new correct with cg approval number weak links.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 January 2019 Resolved
Repair fractured aft rails, stiffeners & gussets.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 20 February 2019
Resolved 20 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2019 Resolved
Cut back wasted shaft logs to good metal & re-install shaft savers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 February 2019
Resolved 20 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2019 Resolved
Renew port MDE sea strainer hose due to wear.
Condition: Improper/Lack of Maintenance
Due 20 February 2019
Resolved 20 February 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 January 2019 Resolved
Renew wasted FWD STBD shell connection IWO #2 void.
Condition: Improper/Lack of Maintenance
Due 20 February 2019
Resolved 20 February 2019
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 April 2018 Resolved
Out dated Aspin and Ammona
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 24 April 2018
Engineering › Bilge Water Management System › Valve
Issued 5 April 2017 Resolved
FWD peak reach rod not conected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 24 April 2017
Resolution: Remounted reach rod with upgraded hardwear.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 April 2017 Resolved
Found cracks in the gusset in the compartment under the passenger compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 2 May 2017
Construction/Loadline › Structures › End Bulkhead
Issued 5 April 2017 Resolved
Port engine exhaust at bulkhead cracked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 2 May 2017
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 April 2017 Resolved
Handrail STBD side in passenger seating area wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 2 May 2017
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 5 April 2017 Resolved
Four life jackets need retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 2 May 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 April 2017 Resolved
Out of date alcohol swabs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 2 May 2017
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 5 April 2017 Resolved
CPR first aid training needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 2 May 2017
Construction/Loadline › Penetrations › Weld
Issued 11 March 2014 Resolved
G&W or C&R fractured gusset IWO port rudder post due to poor welding.
Action required: 705 - Other - as specified
Due 1 April 2015
Resolved 7 April 2015
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 March 2014 Resolved
Install approved hard piping to replace flex hose runs IWO steering system (though E/R and steering compartments).
Action required: 705 - Other - as specified
Due 1 April 2015
Resolved 7 April 2015
Engineering › Bilge Water Management System › Piping
Issued 11 March 2014 Resolved
Renew corroded sections of bilge piping at the next scheduled DD.
Action required: 705 - Other - as specified
Due 1 April 2015
Resolved 7 April 2015
Construction/Loadline › Structures › Superstructure
Issued 30 March 2009 Resolved
Renew fractured pilothouse door window and STBD aft cabin window.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 May 2009
Resolved 29 May 2009
Resolution: Renewed.
Lifesaving › Lifefloat › Lifeline
Issued 18 April 2008 Resolved
Renew improper line on lifefloat light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2008
Resolved 5 May 2009
Resolution: Corrected.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2008 Resolved
Renew improper line on life ring Light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2008
Resolved 5 May 2009
Resolution: Corrected
Lifesaving › Lifefloat › Painter
Issued 18 April 2007 Resolved
Replace wasted painter line to life float.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 1 May 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2007 Resolved
Replace wasted line on ring bouy.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 1 May 2007
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 21 March 2007 Resolved
Crop and renew upper back support for port and stbd dive ladder off the swim platform.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 18 April 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 March 2007 Resolved
Repair welds for hand rails on swim platform.
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 18 April 2007
Construction/Loadline › Hull › Weld
Issued 21 March 2007 Resolved
Repair cracked stitch welds in forward peak.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 18 April 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 March 2007 Resolved
Properly install hydraulic hose fitting to steering ram.
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 21 March 2007
Fire Fighting › Fire Bucket › Availability
Issued 11 April 2006 Resolved
No Fire Buckets on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 11 April 2006
Lifesaving
Issued 20 April 2001 Resolved
REPLACE HYDRO RELEASE FOR 406 EPIRB.
Condition: Unknown
Due 20 April 2001
Resolved 16 May 2001
Lifesaving
Issued 20 April 2001 Resolved
PROVIDE SIX HAND HELD ORANGE FLARES.
Condition: Unknown
Due 20 April 2001
Resolved 16 May 2001
Lifesaving
Issued 20 April 2001 Resolved
REPLACE TWO RING BUOYS FOR PRIMARY LIFESAVING WITH SUITABLE LIFE FLOAT. VESSEL LIMITED TO 22 MAX PERSONS OCEANS ROUTE UNTIL PROVIDED.
Condition: Unknown
Due 26 May 2001
Resolved 16 May 2001
Lifesaving
Issued 7 April 1998 Resolved
PROVIDE CAT 1 406 EPIRB PRIOR TO 01FEB99 AS REQUIRED BY 46 CFR 180.64.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Fire Fighting
Issued 4 April 1997 Resolved
REPLACE HOSE ON ADDITIONAL B-II PORTABLE F/E OR REMOVE F/E FROM VESSEL.
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Lifesaving
Issued 4 April 1997 Resolved
PROVIDE PLACARD TO INDICATE MAXIMUM PERSONS PERMITTED ON UPPER DECK AS PER STABILITY LETTER.
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Documentation
Issued 4 April 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE PROOF OF ENROLLMENT IN CURRENT DRUG TESTING PROGRAM.
Condition: Unknown
Due 7 April 1997
Resolved 7 April 1997
Engineering
Issued 4 April 1997 Resolved
INSTALL ADDITIONAL WRAPPING ON PORT/STBD EXHAUSTS NO LATER THAN 04 MAY 1997.
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Engineering
Issued 4 April 1997 Resolved
INSTALL BELT GUARD IN WAY OF STBD MAIN ENGINE ALTERNATOR NO LATER THAN 04 MAY 1997.
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Engineering
Issued 18 March 1997 Resolved
MAKE PERMANENT REPAIRS, WHERE TEMPORARY REPAIRS EXIST, ON PORT/STBD MAIN ENGINE WET EXHAUSTS.
Condition: Unknown
Due 18 March 1997
Resolved 20 March 1997
Construction/Loadline
Issued 18 March 1997 Resolved
REPAIR FRACTURED WELDS AT THE FOLLOWING LOCATIONS; A TOTAL OF (4) IN AFT STEERING, TOTAL OF (4) IN PASSENGER VOID.
Condition: Unknown
Due 18 March 1997
Resolved 20 March 1997
Engineering
Issued 18 March 1997 Resolved
PRIOR TO COMPLETION OF HULL EXAM, PROVIDE PROPELLERS (2) FOR INSPECTION.
Condition: Unknown
Due 20 March 1997
Resolved 20 March 1997
Construction/Loadline
Issued 18 March 1997 Resolved
REPLACE/PROVIDE VALVE FOR MSD DISCHARGE, WHERE MISSING.
Condition: Unknown
Due 20 March 1997
Resolved 20 March 1997
Lifesaving
Issued 11 April 1996 Resolved
STENCIL PADDLES WITH VESSEL'S NAME.
Condition: Unknown
Due 11 April 1996
Resolved 16 July 1996
Construction/Loadline
Issued 11 April 1996 Resolved
MAKE REPAIRS TO FRACTURES LOCATED IN FLOOR (3RD FROM BOW ON P/S) AND FRAME (4TH FROM BOW ON P/S).
Condition: Unknown
Due 12 April 1996
Resolved 16 July 1996
Construction/Loadline
Issued 11 April 1996 Resolved
MAKE REPAIRS TO FRACTURES LOCATED IN THE FOLLOWING AREAS: 3RD FRAME FROM BOW ON S/S, 2ND FLOOR ON P/S IN WAY OF STANCHION.
Condition: Unknown
Due 12 April 1996
Resolved 16 July 1996
Accommodation/Occupational Safety
Issued 11 April 1996 Resolved
REPAIR/REPLACE PILOT HOUSE WINDOWS WHERE FRACTURED, AT VESSEL'S NEXT DRYDOCK BUT NO LATER THAN 30JAN97.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 11 April 1996 Resolved
PROVIDE TWO ADDITIONAL ADULT TYPE I PFD'S.
Condition: Unknown
Due 11 April 1996
Resolved 16 July 1996
Lifesaving
Issued 13 April 1993 Resolved
PROVIDE TWO PADDLES FOR LIFEFLOAT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Electrical
Issued 13 April 1993 Resolved
PROVIDE PROPER OVERCURRENT PROTECTION FOR 12 AND 24 VOLT SYSTEMS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993

Casualty record · 3

8 August 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3822171
1 May 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4002015
8 August 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5816034
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.