11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2026
Resolved
Each lifejacket carried on a vessel on a Great Lakes route must have a lifejacket light approved IAW 46 CFR 161.012. None of the Type I lifejackets have lights. Vessel is restricted to within 20-miles from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 June 2026
Resolution: Received photographic evidence of installation of life jacket lights.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 June 2026
Resolved
Each 406MHz EPRIB must be installed to float free. Hydrostatic release is expired. Vessel is restricted to within 3 miles from shore until cleared.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 June 2026
Resolution: Received photographic evidence of installation of hydrostatic release with expiration date marked June 2028.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2026
Resolved
A vessel must carry one floating waterlight. No floating waterlight is provided on board. Vessel is restricted to daylight operations until complete.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 July 2026
Resolution: Received photographic evidence of installation of floating waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 June 2026
Resolved
Each lifefloat must be secured to the painter on one end and the vessel at the other. The painter for one life float is not connected to the hydrostatic release.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 June 2026
Resolution: Master properly attached lifefloat painter to the hydrostatic releases.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 June 2026
Resolved
The vessel must carry adequate and up to date:
1. Charts
2. U.S. Coast Pilot
3. Coast Guard Light List.
The charts and publications on board are not up to date.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2026
Resolved 23 July 2026
Resolution: Charts are added to the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 June 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 17 June 2026
Resolution: Discussed procedures for pre-employment testing of employees with owner.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 June 2026
Resolved
The owner, charterer, Master, or managing operator shall instruct each crew member upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months as to the duties the crew member is expectedto perform in an emergency. No record of crew training has been conducted.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 June 2026
Resolution: Discussed requirements for crew training with the owner/operator/Master.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2026
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. The bilge pipe for the fwd compartment is leaking into the #2 compartment.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 June 2026
Resolution: Received photographic evidence of installation of new coupling in #2 bilge void.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 June 2026
Resolved
A hatch exposed to the weather must be watertight. The gasket in way of the bow hatch is wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2026
Resolved 23 July 2026
Resolution: Hatch gasket replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 June 2026
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior port of the stern of the vessel. The hailing port on the certificate of documentation is "Plainfield, IL" The hailing port on the stern is "Hammond, IN".
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 June 2026
Resolution: Received photographic evidence of proper hailing port on stern of vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2025
Resolved
Each floating water light must be approved in accordance with 46 CFR 161.010. The floating water light are provided with the incorrect batteries. Provide the batteries recommended by the manufacture.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 9 September 2025
Resolution: proper batteries installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2025
Resolved
Portable fire extinguishers must be inspected and maintained IAW NFPA 10. The two CO2 fire extinguishers onboard have not had a hose continuity test since 2022. Conduct continuity test. Test must be conducted by a certified technician.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 9 September 2025
Resolution: Test complete.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 June 2025
Resolved
A vessel on a oceans, coastwise, limited coastwise, or great lakes route must carry:
(1) Six hand red flare distress signals and;
(2) Six hand orange smoke distress signals.
The vessel only has 03 red flare distress and 06 hand orange smoke distress signals.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 12 June 2025
Resolution: Flares added.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 June 2025
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or kit with equivalent contents and instructions. The vessels first aid kit has expired contents.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 9 September 2025
Resolution: kit installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2025
Resolved
At each inspection, the marine inspector shall examine the intake valves and determine they are in the proper operating condition and fit for the service intended. The flexible hose between the raw water intake valve and raw water filter in void #2 is worn. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2025
Resolved 12 June 2025
Resolution: hose replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2025
Resolved
Each bilge line shall be provided with a check valve at some accessible point in the bilge line. The threaded cover for the check valve in the #2 void bilge piping is missing. Replace the cover and prove proper operation of check valves in all bilge lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2025
Resolution: Valve cap installed and system tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2025
Resolved
Battery chargers must have an ammeter connected in the charging circuit. The battery charger mounted on the aft engine room bulkhead is not provided with an ammeter in the circuit. Provide the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 12 June 2025
Resolution: charger was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2025
Resolved
Fire hazards on board shall be minimized. The diesel fuel return line for the starboard main engine is leaking at the fuel cooler. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2025
Resolved 12 June 2025
Resolution: leak was repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2025
Resolved
The floating water light for the life float must be attached around the body of the life float by a 10mm (3/8) lanyard resistant to deterioration from ultra-violet light and at least 18 feet in length. The lanyard for the floating water light in way of the large life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 9 September 2025
Resolution: new line installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2025
Resolved
Each life float must be fitted with a painter. The painter must: Be at least 100ft in length, have a breaking strength of at least 1500 lbs, be of a dark color if synthetic, be stowed in such a way that it runs out freely when the life float floats away from a sinking vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 9 September 2025
Resolution: Painter added to vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 5 June 2025
Resolved
At each inspection, the toilet and washing spaces may be examined to determine they are in serviceable condition. The flexible hose between the sink and pvc pipe in the #2 void is missing the top most hose clamp and the flexible hose itself is deteriorated. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2025
Resolved 12 June 2025
Resolution: pipe was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2025
Resolved
Propulsion machinery must be suitable in type and design for the propulsion requirements of the hull. The starboard main engine forward inboard motor mount is fractured. Make repairs to the same.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2025
Resolution: mount was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2025
Resolved
Propulsion machinery must be suitable in type and design for the propulsion requirements of the hull. The port main engine serpentine belt is worn. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2025
Resolution: Belt replaced on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 May 2024
Resolved
The life raft float free must be IAW 180.130 (a)(1) must be proper for size of raft. Add name of vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 30 May 2024
Resolution: New link installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 May 2024
Resolved
An exposed hazard, such as gears or rotating machinery must have guards. The engine driven fire pump has no guards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 14 June 2024
Resolution: Guard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2024
Resolved
Conduct maintenance of the main engines Air sep system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 7 June 2024
Resolution: airsep cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2024
Resolved
Hydraulic oil found in the steering space. Determine cause and repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2024
Resolved
Crew using un-approved life vests for MOB. Install proper vest.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 25 July 2024
Resolution: Special Consideration letter routed for signature.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2024
Resolved
A vessel on a Great Lakes route must carry six hand held red flares, and six orange smoke distress signals. Vessel is only provided with 4-red and 3-orange distress signals. Provide correct amount of distress signals.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: proper number installed
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 6 May 2024
Resolved
Properly mount the on/off switch for the vessel's OTS, properly mount the radar wiring, and prove proper operation of the radar.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Radar all sat.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 6 May 2024
Resolved
Each vessel must be provided with a PA system. The PA system is only working intermittently. Prove proper operation of the PA system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: PA fuction tested, All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2024
Resolved
A vessel must carry adequeate & up to date charts of the intended area, light list, and coast pilot. Provide up to date copies of the all of the above on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2024
Resolved
A vessel must be provided with non-combustible waste receptacles. Remove plastic trash cans from the vessel and provide non-combustible waste receptacles.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: proper cans installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 May 2024
Resolved
A durable radio broadcast placard with information specific to the vessel must be posted. The posted broadcast placard does not have the vessel specific information completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: placard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024
Resolved
The valve handle in way of the overboard discharge in the forward space is broken. Make repairs to the same.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: valve handle replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024
Resolved
The flexible hose in way of the automatic bilge pump in the forward space is no secured to the overboard discharge. Properly secure the same.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Hose clamp tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024
Resolved
Prove proper operation of the automatic bilge pump in the forward space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Bilge pump tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024
Resolved
A vessel of less than 65ft carring not more than 49 passengers must be provided with a fixed power bilge pump. The bilge pump is inoperable. Prove proper operation of the same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: All suction points were tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2024
Resolved
The flexible hose in way of the A/C water intake is worn. Repair or replace the same.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: hose clamp added.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 May 2024
Resolved
At each inspection the owner must make life saving equipment available. Make both life floats available for inspection and ensure proper marking, eqipment and installation is complete as required.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: rafts inspected.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 May 2024
Resolved
The crew must be trained to the rquirements in 46 CFR 185.420 and conduct the drills required in 46 CFR 185.524 every three months. The training muste be logged and available for review.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Drills conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 31 May 2023
Resolved
Vessel EPIRB registration is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 9 June 2023
Resolution: Received NOAA Registration Card.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2023
Resolved
Two different style life jackets are on board. Install donning placard for both style jackets or remove different jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2023
Resolution: removed all non-standard jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 July 2022
Resolved
All onboard fire extinguisher have not been serviced and expired on 01JUL22. Replace or service prior to carrying passengers. Provide service report.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 July 2022
Resolution: Spares were provided by Fire Service Tech.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 1 July 2022
Resolved
Collision bulkhead water suction valve handle needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2022
Resolution: New handle installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 1 July 2022
Resolved
STBD Aft Pilot house window is cracked and needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 November 2022
Resolution: Window replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 July 2022
Resolved
Lifesaving and firefighting equipment inspections have not been logged or completed. Provide evidence that inspection program is developed and followed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2022
Resolution: Records of logs for month of july reviewed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 July 2022
Resolved
MOB and Fire Drills have not been completed for 2022. Conduct these drills with crews and provide 30 days of logs to MSU Chicago by 02AUG22
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2022
Resolution: records of logs reviewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2021
Resolved
Replace defective Ring Bouy.
Action required: 705 - Other - as specified
Due 10 June 2021
Resolved 10 June 2021
Resolution: Ring Bouy was extra and removed from Vessele
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 10 June 2021
Resolved
Renew Hydrostatic release for EPIRB. vessel route is restricted to 1 mile.
Action required: 705 - Other - as specified
Due 11 June 2021
Resolved 11 June 2021
Resolution: EPIRB temporary moved to a float free arrangement. New Hydro release has been ordered and will install and place EPIRB in a new location.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 June 2021
Resolved
Replace Discharge Hose of fire pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2021
Resolved 24 June 2021
Resolution: Discharge Hose was replaced and tested
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2021
Resolved
Found 6 defective Adult Life Jackets. Reduced passenger count by 6, to 21 total persons
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2021
Resolved 16 August 2021
Resolution: Received photos of new life jeckets that are properly marked with name and retro tape
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 10 June 2020
Resolved
Installed weak links were not CG approved. vessel is limited to 3 miles from shore
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2020
Resolved 11 June 2020
Resolution: Vessel Received brand new correct with cg approval number weak links.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 January 2019
Resolved
Repair fractured aft rails, stiffeners & gussets.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 20 February 2019
Resolved 20 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2019
Resolved
Cut back wasted shaft logs to good metal & re-install shaft savers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 February 2019
Resolved 20 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2019
Resolved
Renew port MDE sea strainer hose due to wear.
Condition: Improper/Lack of Maintenance
Due 20 February 2019
Resolved 20 February 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 January 2019
Resolved
Renew wasted FWD STBD shell connection IWO #2 void.
Condition: Improper/Lack of Maintenance
Due 20 February 2019
Resolved 20 February 2019
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 April 2018
Resolved
Out dated Aspin and Ammona
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2018
Resolved 24 April 2018
Engineering › Bilge Water Management System › Valve
Issued 5 April 2017
Resolved
FWD peak reach rod not conected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 24 April 2017
Resolution: Remounted reach rod with upgraded hardwear.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 April 2017
Resolved
Found cracks in the gusset in the compartment under the passenger compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 2 May 2017
Construction/Loadline › Structures › End Bulkhead
Issued 5 April 2017
Resolved
Port engine exhaust at bulkhead cracked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 2 May 2017
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 April 2017
Resolved
Handrail STBD side in passenger seating area wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 2 May 2017
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 5 April 2017
Resolved
Four life jackets need retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 2 May 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 April 2017
Resolved
Out of date alcohol swabs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 2 May 2017
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 5 April 2017
Resolved
CPR first aid training needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 2 May 2017