← All vessels

MAGGIE TOO

MAGGIE TOO is a 1997 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 1998, most recently in July 2025, along with 29 deficiencies.

Records from 1998 to 2025. Most recent: inspection, 28 July 2025.

Built
1997
Last inspected
28 July 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

485204
Flag
UNITED STATES
—
Maury page id
psix-485204

Inspections, by type

Years with a record 25 calendar years (1998–2025)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it2 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

28 July 2025 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8197022
24 June 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7929477
13 June 2023 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7758223
20 June 2022 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7482249
10 June 2021 Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7219477
7 September 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7080505
5 June 2019 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6704953
19 June 2018 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6436445
14 June 2017 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6266165
8 June 2016 Internal Structural Exam · Drydock Exam · COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5899637
24 June 2014 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4919047
19 June 2012 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4399481
15 December 2011 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4208840
7 July 2009 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3589459
23 June 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3277924
7 June 2007 Administrative Inspection · Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3094971
14 June 2006 COI Inspection · Hull Examination · MARPOL Annex V Examination · Internal Structural Exam
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2667694
12 July 2005 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2424494
3 June 2004 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2109722
3 June 2003 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1810607
10 June 2002 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1648590
25 May 2001 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1440537
4 June 2000 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1395480
14 July 1999 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1460342
10 June 1998 Initial Certification · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1429063

Deficiency record · 29

01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 23 September 2024 Resolved
If deficiencies are found or a major change to the vessel has occurred, the marine inspector will conduct an inspection more detailed in scope to ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. The main engine (502 c.i. Chevy) was repowered with a 6.2L V8 VVT DI (L87) with major weight changes. A simplified stability test must be conducted in accordance with 46 CFR 178.330 and in the presence of a marine inspector. 46 CFR 176.500(b)(1)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 September 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufactures instructions. The manual override function on the pre-engineered fire extinguishing system (Fireboy) didn't enable to operator to restart the engine. Make manual override function operational in accordance with manufacture instructions. 46 CFR 181.420(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 September 2024 Resolved
If a State issues validation stickers, its numbering system must contain the requirements that stickers must be displayed within 6 inches of the number. The state registration sticker and certificate were not onboard, post registration sticker and provide proof of registration. 33 CFR 174.15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2024
Resolved 18 September 2025
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 September 2024 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire drills are not being logged, maintain logs of drills being conducted. 46 CFR 185.524(d)
Action required: 10 - Deficiency Rectified
Resolved 23 September 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 September 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The annual inspection was required to be completed by 10SEP2024, the annual inspection was not conducted until 23SEP2024.
Action required: 10 - Deficiency Rectified
Resolved 23 September 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel operator was not able to provide documentation of drug testing program, provide documentation of enrollment in testing program and list of employees who are enrolled. 46 CFR 16.230
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2024
Resolved 18 September 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2024 Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. The vessel is undergoing a re-power that is not a replacement in-kind without notification and drawings or written specifications describing any of the proposed alterations. Submit drawings and written specifications on replacement engine, fuel system, piping system, and electrical system. 46 CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2025
Lifesaving › Lifebuoys › Serviceable
Issued 8 June 2016 Resolved
Provide life ring with proper amount of retro tape and stencil or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 14 October 2016
Resolution: New life ring was provided.
Lifesaving › Lifebuoys › Stowage
Issued 8 June 2016 Resolved
Provide bracket for life float light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 14 October 2016
Resolution: New bracket for life float light was provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 June 2016 Resolved
Provide proper bracket for fire extinguisher
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 14 October 2016
Resolution: New bracket for fire extinguisher was provided
Fire Fighting › Fire Bucket › Quantity
Issued 8 June 2016 Resolved
Provide three stenciled 2.5 gallon Fire Buckets.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 14 October 2016
Resolution: 3 new fire buckets were provided.
Documentation › Certificates/Documents › Stability Letter
Issued 15 December 2011 Resolved
Total paxs allowed o/b is reduced to 10 total paxs utilizing the weight standards that became effective on December 1st, 2011. O/O must submit a "Certification of Stability Compliance" to OCMI. once certification is rcvd and compliance has been verified. The COI will be updated to reflect the new weight standards.
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 19 June 2012
Resolution: O/O agreed to passenger reduction, and is authorized to carry 10 pasengers with two crew.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 June 2008 Resolved
Provide proof of enrollment in drug testing program for all vsl operators and crew and neg preemployment tests.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2008
Resolved 2 July 2008
Resolution: Satisfactory Proof of enrollment and negative test results were sent via email to Sector Anchorage.
Documentation › Markings/Placards › Warning Signs
Issued 23 June 2008 Resolved
Provide/post emergency instructions IAW 46 CFR 185.12.
Action required: 705 - Other - as specified
Due 23 July 2008
Resolved 30 June 2008
Resolution: During phone conversation w/ vessel operator, master stated that he had found the cite and printed the suggested verbage to post in the vessel.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 23 June 2008 Resolved
Provide proper anchor and line.
Action required: 705 - Other - as specified
Due 23 July 2008
Resolved 30 June 2008
Resolution: Master sent statement that proper anchor and line had been placed on the vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 June 2008 Resolved
Provide first aid kit IAQ 46 CFR 160.011.
Action required: 705 - Other - as specified
Due 23 July 2008
Resolved 23 July 2008
Resolution: Master sent email statement that proper first aid kit had been purchased and placed on the vessel.
Fire Fighting › Fire Bucket › Quantity
Issued 23 June 2008 Resolved
Provide three fire buckets.
Action required: 705 - Other - as specified
Due 23 July 2008
Resolved 30 June 2008
Resolution: Master sent email statement that fire buckets had been procured and placed on the vessel.
Engineering › Bilge Water Management System › Pump
Issued 23 June 2008 Resolved
Provide portable bilge pump.
Action required: 705 - Other - as specified
Due 23 July 2008
Resolved 30 June 2008
Resolution: Master sent email statement that portable bilge pump had been procured and placed on the vessel.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 7 June 2007 Resolved
Replace existing fireboy arrangement at control station with Coast Guard approved type that automatically shuts down engine (46 CFR 181.420(a)(3) and has means to reset (46 CFR181.420(b)(3). Ensure system has a light and audible alarn that sounds upon discharge. (46 CFR 181.420(b)(1)(2).
Due 7 July 2007
Resolved 23 June 2008
Resolution: Proper fireboy equipped w/ automatic shutdown was installed and tested satisfactory at 2008 annual.
Communications › Audible Communications › Horn/Whistle
Issued 3 June 2004 Resolved
Provide an operational horn.
Due 3 July 2004
Resolved 21 June 2004
Resolution: Horn repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 June 2004 Resolved
Repair bilge high level alarm.
Due 3 July 2004
Resolved 4 June 2004
Resolution: Bilge high level alarm repaired.
Accommodation/Occupational Safety
Issued 10 June 1998 Resolved
clean storage area aft stbd side
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Lifesaving
Issued 10 June 1998 Resolved
SUPPLY FIRST AID KIT ABOARD.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Construction/Loadline
Issued 10 June 1998 Resolved
INSTALL HIGH WATER INDICATOR IN BILGE AREA.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Navigation
Issued 10 June 1998 Resolved
SUPPLY 2 FLASHLIGHTS ABOARD.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Navigation
Issued 10 June 1998 Resolved
Repair starboard running light.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Fire Fighting
Issued 10 June 1998 Resolved
REPLACE DISCHARGED FIREBOY BOTTLE.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Fire Fighting
Issued 10 June 1998 Resolved
SUPPLY 3 BUCKETS, 2.5 GAL EACH, WITH LANYARDS FOR FIRE BUCKETS.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Lifesaving
Issued 10 June 1998 Resolved
APPLY RETRO-REFLECTIVE TAPE, 4 STRIPS EACH SIDE, AND VESSEL NAME TO RING BUOY. MOUNT WATER LIGHT AND RING BUOY, ATTACH LINE TO RING BUOY.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998

Ownership record