Inspection history · 19
9 February 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8319521
8 September 2025
Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8229447
14 December 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8072692
20 November 2024
COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8033357
27 February 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7870786
21 September 2023
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7810388
27 February 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7642671
30 March 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7421593
1 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7403635
9 September 2021
Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7307634
23 March 2021
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7161391
2 December 2019
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6861902
9 October 2019
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6831661
18 September 2019
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6814825
12 March 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6640712
5 March 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6366163
18 September 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6269502
7 March 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6100433
29 February 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5823696
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 September 2025
Resolved
A hatch exposed to the weather must be watertight. Deck hatch on forepeak had a wasted seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 September 2025
Resolution: Hatch seal was replaced in kind and found to be water tight by the attending MI.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 20 November 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. Marine inspectors observed three 5-gallon buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 9 January 2025
Resolution: Obtained 3 fire buckets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10.
Extinguisher readiness. Portable fire extinguishers shall be maintained in fully charged and operable condition. Fire extinguisher on the top deck on the port side was discharged and the gauge showed below pressure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 8 January 2025
Resolution: fire extinguisher properly labeled.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 November 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Emergency exit on the bow not properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 8 January 2025
Resolution: Exit properly labeled.
14 - Pollution Prevention › 143 - MARPOL Annex III › Marking and labelling
Issued 20 November 2024
Resolved
A vessel must comply with the applicable design equipment, personnel, procedures, and record requirements of 33 CFR parts 151, 155, and 156. Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§ 151.51 through 151.77; Every ship of 12 m or more in length overall shall display placards which notify the crew and passengers of the disposal requirements of regulation 3 and 5 of this annex.
Vessel did not have required garbage placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 8 January 2025
Resolution: Garbage placard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. MI’s observed a bilge pump in the forward liquor room bilge not of approved type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 8 January 2025
Resolution: Proper bilge pump installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 November 2024
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. MI observed gauges at the helm for the port MDE not operating properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 16 June 2026
Resolution: Replaced panel on helm and electrical wires. Water damage on upper exposed steering station caused damage to wiring.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 November 2024
Resolved
A hatch exposed to the weather must be watertight. Hatch leading to steering space not securing properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 8 January 2025
Resolution: Hatch cleaned for proper operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 November 2024
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow.
Vessel did not have starboard, or Port side bow marked with the vessel name.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 27 January 2025
Resolution: name placed on the bow.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 November 2024
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. FWD shutoff valve required maintenance.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2024
Resolved 20 November 2024
Resolution: Cleared and repaired during inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2024
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.Monthly inspections of portable fire extinguishers were not completed on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 November 2024
Resolved 20 November 2024
Resolution: MI discussed with operator, proper procedures for documenting monthly inspections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high-water level in each unmanned spaces subject to flooding from sea water.
Audible alarm at the operating station was stuck in the silence position preventing future alarms from operating as intended.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2024
Resolved 20 November 2024
Resolution: Repairs made during inspection to silence switch.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 March 2024
Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees. Vessel's radio using DSC techniques was unable to upload assigned MMSI number into their radio installation. Vessel must upload MMSI number assigned into radio installation.
47 CFR 80.103(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2024
Resolved 18 March 2024
Resolution: Received documentation from the vessel showing correction of deficiency #2, the MMSI number not being in their radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2023
Resolved
Each vessel must have one or more life buoys. Replace deteriorated ring buoy.
46 CFR 180.70(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2023
Resolution: New life buoy installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2023
Resolved
At least one life ring buoy must be fitted with a lifeline... of at least 60 feet in length. Obtain lifeline of 60 feet or greater.
46 CFR 180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2023
Resolution: Life buoy fitted with 60 foot lifeline.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2023
Resolved
Each floating waterlight... must be attached to a lanyard with a corrosion resisting clip... and allow the waterlight to be quickly disconnected from the ring life buoy. Configure waterlight and clip in a way that meets the above requirements.
46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2023
Resolution: Floating waterlight on life buoy fitted with new clip.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2023
Resolved
Vessel must have at least three 2.5 gallon buckets... with an attached lanyard. Obtain 2.5 gallon buckets, attach lanyards, and properly marked.
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2023
Resolution: Vessel outfitted with 3 2.5 gallon fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2022
Resolved
An adult lifejacket must be provided for each person carried on board a vessel. Replace 07 adult lifejackets, limit total persons onboard to 46.
46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 2 March 2022
Resolution: Owner submitted photos of new lifejackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 March 2022
Resolved
A hatch exposed to the weather must be watertight. Replace aft lazarette hatch gasket to make watertight.
46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2022
Resolution: Owner submitted photos of renewed hatch gasket.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 March 2021
Resolved
Owner or operator must provide satisfactory evidence of required servicing of fixed gas fire fighting system. Pre engineered FGFF system has signs of corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2021
Resolved 9 April 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 March 2021
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2021
Resolved 26 March 2021
Resolution: Conducted inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2019
Resolved
Replace valve handle on through hull valve in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 23 September 2019
Resolution: Valve handle repalced.