MAURY USCG vessel records Sign in
← All vessels

LAURA JEAN

LAURA JEAN is a 1998 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 1999, most recently in June 2008, along with 7 deficiencies.

Records from 1999 to 2008. Most recent: inspection, 3 June 2008.

Built
1998
Last inspected
3 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY7787
485274
Flag
UNITED STATES
—
Maury page id
psix-485274

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (1999–2008)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

3 June 2008 Simplified Stability Test · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3231474
29 May 2007 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2944527
22 May 2007 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2936969
27 February 2007 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2878646
23 May 2005 Hull Examination · Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2385982
4 June 2004 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2095567
16 May 2003 Annual Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1794846
18 March 2002 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1493945
19 July 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1449501
21 May 2001 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1443198
23 March 2001 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1373403
1 May 2000 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1435047
23 March 1999 Initial Certification · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1402815

Deficiency record · 7

Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 June 2008 Resolved
Properly segregate child PFD's from adult PFD's and label storage areas properly.
Condition: Improper Installation
Due 1 July 2008
Resolved 17 June 2008
Resolution: PFD''s were segregated and storage areas labeled.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 June 2008 Resolved
Conduct satisfactory MOB
Condition: Unknown
Due 3 June 2008
Resolved 17 June 2008
Resolution: MOB drill was completed.
Documentation › Logs/Records › Enhanced Survey Report File
Issued 3 June 2008 Resolved
Provided schematic or blueprints for canopy and provide weight figures for old canopy, new canopy, and loss of bow ramp.
Condition: Improper/Lack of Maintenance
Due 1 July 2008
Resolved 17 June 2008
Resolution: Canopy weighed and change in weight was less that 2%
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2007 Resolved
Drill stop "V-groove" and re-weld crack on stbd side of transom.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2007
Resolution: Made corrective welds.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 22 May 2007 Resolved
Repair or replace propeller.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2007
Resolution: Repaired props.
Lifesaving
Issued 1 May 2000 Resolved
OBTAIN/POST LIFE JACKET DONNING PLACARD. POST SO THAT PASSENGERS HAVE CLEAR VIEW.
Condition: Unknown
Due 15 May 2000
Resolved 24 May 2000
Fire Fighting
Issued 1 May 2000 Resolved
OBTAIN TYPE A-II PORTABLE FIRE EXTINGUISHER AND MOUNT ON VESSEL PER COI.
Condition: Unknown
Due 5 May 2000
Resolved 24 May 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.