MAURY USCG vessel records
← All vessels

MR. DINO

MR. DINO is a 1975 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in May 2026, along with 25 deficiencies, 1 operational control and 4 casualty investigations between 2002 and 2013.

Records from 2002 to 2026. Most recent: inspection, 21 May 2026.

Built
1975
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF4396
Flag
UNITED STATES
Maury page id
psix-48551

Inspections, by type

Years with a record 11 calendar years (2016–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)103.9 ft × 25.0 ft × 6.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIVERSAL IRON WORKS, INC · HOUMA, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 21

21 May 2026 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8373628
7 May 2025 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8126890
21 October 2024 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8022060
26 June 2024 Internal Structural Exam · Deficiency Check · Hull Examination · Deadweight Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7906196
7 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7907812
6 June 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7704253
23 February 2023 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7640988
20 December 2022 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7616408
30 June 2022 Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7490372
9 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7445151
3 May 2022 In-Service Inspection · Drydock Extension · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7443031
14 October 2021 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7332965
14 July 2021 Annual Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7249582
6 May 2020 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6949015
29 April 2020 Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6945782
14 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6683626
10 April 2019 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6659704
23 April 2018 Re-Inspection · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6397188
2 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6136933
24 April 2017 Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6131213
19 April 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5857997

Deficiency record · 25

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2025 Resolved
Vessel Captain reported both fire hoses burst during routine inspection and maintenance. New hoses are on order. Install fire hoses and prove proper operation of the vessel's fire pump prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 May 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 21 May 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2025 Resolved
Conduct and log egress training/drills each time a crew member joins the vessel and at least every month they are employed on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 21 May 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 May 2024 Resolved
The hydrostatic release for the vessel's Cat I EPIRB is expired. Provide, mark, and install an new hydrostatic release prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 7 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 May 2024 Resolved
The starboard and stern navigation lights are not working. Diagnose issue and prove lights operate prior to operating in reduced visibility.
Action required: 705 - Other - as specified
Resolved 7 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2023 Resolved
Provide a valid FCC Bridge to Bridge Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2023 Resolved
Provide a valid FCC Safety Radiotelephony Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 June 2022 Resolved
Broken support bracket for fore peak reach rod. 46 CFR 176.20-1 (Old T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 July 2022
Resolution: See MISLE Activity 7490372
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 May 2022 Resolved
Suitably insulate the dry exhaust piping in the engine room and service space to prevent injuries to the crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 July 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 May 2022 Resolved
Install metal supports on cable runs spaced not more than 24" apart, and in such a manner as to avoid chaffing and other damage.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 June 2022
Resolution: Installed supports <24" apart for cables.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2022 Resolved
The vessel is required to conduct a drydock exam and an internal structural exam at least once every two years. The vessel did not complete a drydock exam and internal structural exam prior to its required date of 30 April 2022. Vessel must complete a credit drydock exam and internal structural exam prior to carrying passengers or cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2022
Resolution: Drydock extension authorized until scheduled haul out date on June 4th, 2022.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 July 2021 Resolved
Vessel has a Class 1 Watertight Door separating its machinery space from a work space. Vessel must remove the watertight door and make the bulkhead watertight to original design strength prior to a change of employment to traditional passenger service.
Action required: 705 - Other - as specified
Resolved 28 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 July 2021 Resolved
Provide a Type I adult life jacket for each person on board. Vessel limited to carrying 18 total passengers and 22 total people until an additional 02 Type I adult life jackets are provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 14 July 2021 Resolved
Mark the vessel's current hailing port on its stern with clearly legible letters of not less than four inches in height.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 July 2021 Resolved
Provide documentation that each crewmember in a supervisory position has received at least one hour of Employee Assistance Program training as part of the vessel's chemical testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 July 2021 Resolved
Conduct monthly tests of the vessel's EPIRB and log or otherwise document the test.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 14 July 2021 Resolved
Install sea rails on the vessel's cooking range.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 July 2021 Resolved
Vessel's deck rails in the cargo area are not at least 36" high. Clearly mark the area on the cargo deck where passengers are not allowed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 July 2021 Resolved
Vessel's transmission cooling lines were oil soaked. Replace the transmission cooling lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 July 2021 Resolved
Vessel has a Class 1 Watertight Door separating its machinery space from a crew space. Vessel must install an indicator light on the bridge to warn when the door is open.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2019 Resolved
Port engine is missing cover for rotating machinery. Suitable covers or guards shall be installed on all exposed gears, machinery, etc.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2019
Resolved 10 April 2019
Resolution: Guard put in place over rotating machinery.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 April 2019 Resolved
Found excessive accumulation of oil in bilges. Remove/pump off oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2019
Resolved 10 April 2019
Resolution: Oil cleaned out of bilges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2019 Resolved
Excessive leaking around shaft packing seal. Tighten shaft packing seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2019
Resolved 10 April 2019
Resolution: Shaft seals tightened. No signs of water leaking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2019 Resolved
Petcocks for fuel strainers did not have caps or plugs. Valves for removing water from fuel in strainers is permitted, but shall be provided with caps or plugs. 46 CFR 182.20-40(a)(7) - OLD T
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2019
Resolved 10 April 2019
Resolution: Plugs put into place.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 April 2018 Resolved
NAVIGATION LIGHT DO NOT FUNCTION ON EMERGENCY POWER.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 25 April 2018
Resolution: 3RD PARTY ELECTRICIAN COMPLETED BATTERY BACKUP INSTALLATION.

Casualty record · 4

29 July 2002Routine · role: Involved in a Marine Casualty · activity 1653998
1 December 2007Routine · role: Involved in a Marine Casualty · activity 3139662
10 May 2009Routine · role: Involved in a Marine Casualty · activity 3487413
4 August 2013Routine · role: Alleged Pollution Source · activity 4684812
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

EPIC ENDEAVOR (2002–2007), ENDEAVOR (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.