MAURY USCG vessel records Sign in
← All vessels

DEREK JOHN

DEREK JOHN is a 1975 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 1980, most recently in February 2011, along with 36 deficiencies.

Records from 1980 to 2011. Most recent: inspection, 24 February 2011.

Built
1975
Last inspected
24 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC4603
Flag
UNKNOWN
338223000, 367027340 (licence lapsed)
Maury page id
psix-48552

Inspections, by type

…with no type recorded12
Years with a record 22 calendar years (1980–2011)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC4603MMSI 367027340 · cancelled · compulsorily equipped · granted 25 March 2005, cancelled 16 March 2015
WCZ7962MMSI 338223000 · expired · compulsorily equipped · granted 2 May 2000, cancelled 3 July 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 40

24 February 2011 COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3951504
23 August 2006 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2757709
8 December 2005 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2548028
25 October 2005 Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2518468
3 October 2005 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2506800
8 July 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2421398
13 July 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2131910
7 October 2003 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1922073
1 May 2003 Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1783010
25 April 2002 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608922
22 April 2002 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607836
15 May 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1064183
3 May 2000 COI Inspection · Inclining Experiment · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443009
6 January 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1143391
12 March 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1265084
6 March 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1259723
25 October 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248674
13 March 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1236708
22 February 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230231
28 December 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1231319
18 December 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914949
5 December 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909687
26 October 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211460
30 October 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017079
6 October 1989 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1195963
3 August 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889444
8 December 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899051
23 September 1988 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1351482
10 December 1987 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1308183
23 June 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313362
30 September 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316581
30 May 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298387
19 December 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301259
17 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290916
8 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280566
8 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283656
3 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969741
1 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275653
5 December 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277136
4 December 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271614

Deficiency record · 36

Personnel › Certificates/Documents/Licenses › License, Operator
Issued 23 August 2006 Resolved
Both masters did not have radio operator permits
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2006
Resolved 24 August 2006
Documentation › Markings/Placards › Warning Signs
Issued 23 August 2006 Resolved
Label all water tight doors on both sides as "water tight keep closed".
Due 23 September 2006
Resolved 24 August 2006
Engineering › Steering Gear System › Rudder
Issued 23 August 2006 Resolved
Missing double nuts on rudder post.
Due 23 September 2006
Resolved 24 August 2006
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 23 August 2006 Resolved
Rescue platform was not designed to be used at the existing embarkation station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2006
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 August 2006 Resolved
Vessel did not have required alcohol testing devices onboard.
Due 23 September 2006
Resolved 24 August 2006
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 8 December 2005 Resolved
Failure to provide required additional fire fighting equipment for carriage of flammable MPT's per vessel COI and 49 CFR 176.315.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2006
Resolved 24 February 2011
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 8 July 2005 Resolved
Missing two additional; fire extinguishers required by 49CFR176.315
Condition: Improper/Lack of Maintenance
Due 8 July 2005
Resolved 25 October 2005
Resolution: Vessel purchased semi portable fire extinguisher meeting the requirements of 49CFR176.315
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 July 2005 Resolved
Vessel purchased in March.
Condition: Improper/Lack of Maintenance
Due 8 July 2005
Resolved 8 July 2005
Electrical › Electrical Distribution System (emergency) › Outlet Box
Issued 8 July 2005 Resolved
Missing additional light in steering compartment
Condition: Improper/Lack of Maintenance
Due 8 August 2005
Resolved 8 July 2005
Navigation › Piloting/Steering › Compass Deviation Table
Issued 8 July 2005 Resolved
Condition: Improper/Lack of Maintenance
Due 8 August 2005
Resolved 8 July 2005
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 21 July 2004 Resolved
Provide crew training log as per 46 CFR 185.420(c).
Action required: 705 - Other - as specified
Due 21 August 2004
Resolved 8 July 2005
Documentation › Logs/Records › Garbage Recordkeeping
Issued 21 July 2004 Resolved
Provide a written record for garbage disposal as per 33 CFR 151.55.
Action required: 705 - Other - as specified
Due 21 August 2004
Resolved 8 July 2005
Engineering › Fuel Oil Service System › Filter
Issued 1 May 2003 Resolved
Provide metallic plugs for the fuel filters. Petcocks on the bottom do not have plugs. 46CFR182.01-5 (1995)
Action required: 705 - Other - as specified
Due 1 June 2003
Resolved 21 July 2004
Resolution: Appropriate plugs installed.
Construction/Loadline › Hull › Stiffener
Issued 1 May 2003 Resolved
Repair 4 cracked welds, 3 in the stern & 1 in the forepeak. 46CFR177.10-1(1995)
Action required: 705 - Other - as specified
Due 1 June 2003
Resolved 21 July 2004
Resolution: Fractured welds repaired.
Documentation
Issued 6 March 1992 Resolved
2: PROVIDE A VALID U.S. COAST GUARD DOCUMENTATION CERTIFICATE OR RENEWAL STAMP WITH EXPIRATION DATE._x001C_
Condition: Unknown
Due 20 March 1992
Resolved 26 March 1992
Documentation
Issued 6 March 1992 Resolved
1: PROVIDE A VALID COMMUNICATIONS ACT SAFETY CERTIFICATE (SECTION 80.401)_x001C_ (FCC)
Condition: Unknown
Due 20 March 1992
Resolved 26 March 1992
Construction/Loadline
Issued 25 October 1991 Resolved
MAKE PERMANENT REPAIRS TO PENETRATION OF FWD ENGINEROOM BULKHEAD WHERE AIR CONDITIONING PRIPING PENETRATES ON STBD SIDE.
Condition: Unknown
Due 25 October 1991
Resolved 25 October 1991
Engineering
Issued 25 October 1991 Resolved
PROVE PROPER OPERATION OF PORT SHIP GENERATOR TO SATISFACTION OF MARINE INSPECTOR.
Condition: Unknown
Due 25 October 1991
Resolved 25 October 1991
Accommodation/Occupational Safety
Issued 25 October 1991 Resolved
REPLACE STARBOARD AFT WINDOW IN PASSENGER COMPARTMENT
Condition: Unknown
Due 25 October 1991
Resolved 25 October 1991
Electrical
Issued 25 October 1991 Resolved
REMOVE WIRING OR PROPERLY SUPPORT IN METAL CLAMPS WIRING FOR WTD SWITCHES RUNNING THROUGH FWD & AFT ACCOMMODATION SPACES AND WIRING IN ENGINE ROOM.
Condition: Unknown
Due 25 October 1991
Resolved 25 October 1991
Construction/Loadline
Issued 13 March 1991 Resolved
PROVIDE DOCUMENTATION OF LOAD LINE ASSIGNING AUTHORITY (ABS) ACCEPTANCE OF MODIFIED MACHINERY SPACE ACCESS (FLUSH DECK SCUTTLE). DOCUMENTATION MAY BEIN THE FORM OF CORRESPONDENCE FROM ABS OR COPY OF REVISED ABS FORM LL-11-D.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Construction/Loadline
Issued 22 February 1991 Resolved
Remove watertight door between engineroom and lazarette and properly insertbulkhead. Refer to MSO New Orleans letter dtd 22FEB91, 46CFR170.255 and 46CFR177.15-1.
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991
Construction/Loadline
Issued 22 February 1991 Resolved
Remove watertight door between galley and after accommodations, properly insert bulkhead and provide emergency means of escape from the galley compartment. Refer to MSO New Orleans letter dtd 22FEB91, 46CFR170.255 and46CFR177.15-1.
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991
Electrical
Issued 26 October 1990 Resolved
REPLACE THREE MISSING LIGHT GLOBES IN AFTER CREW BERTHING. 46 CFR 183.10-20AND 46 CFR 183.01-15
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Electrical
Issued 26 October 1990 Resolved
REPLACE 12 VOLT POWER SUPPLY IN PILOTHOUSE FOR LORAN AND DEPTH SOUNDER. 46 CFR 183.01-10
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Electrical
Issued 26 October 1990 Resolved
REPAIR OR RENEW MAIN ENGINE INBOARD BATTERY CHARGER IN ENGINEROOM. 46 CFR 183.05-20(F)
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Navigation
Issued 26 October 1990 Resolved
REPAIR OR REPLACE PORT AND STBD FIXED SEARCHLIGHTS. 46 CFR 183.01-10
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Deck/Cargo
Issued 26 October 1990 Resolved
REPLACE EXISTING ANCHORLINE WITH EITHER 360 FEET OF 5/8" GALVANIZED WIRE ROPE OR 360 FEET OF 1 1/4" THREE STRAND NYLON LINE IN ACCORDANCE WITH 46 CFR 184.10 AND CID MEMO 43.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Documentation
Issued 26 October 1990 Resolved
PROVIDE COPY OF PERMANENT LOADLINE CERTIFICATE. CURRENT TEMPORARY LOADLINECERTIFICATE EXPIRES 17OCT90. 46 CFR 175.07/46 CFR 42.03
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Documentation
Issued 26 October 1990 Resolved
REPLACE BURNT OUT LIGHTING THROUGHOUT VESSEL. 46 CFR 183.01-15 AND 46 CFR 183.10-20
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Construction/Loadline
Issued 6 October 1989 Resolved
SUBMIT PLANS TO MSO MIAMI ON WATERTIGHT BULKHEAD MODIFICATIONS
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Construction/Loadline
Issued 6 October 1989 Resolved
SUBMIT PLANS AND STABILITY CALUCLATION ON NEWLY INSTALLED ACCOMODATION LADDERS.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Construction/Loadline
Issued 6 October 1989 Resolved
PROVIDE SECONDARY ESCAPE FROM THE ENGINEROOM
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Construction/Loadline
Issued 6 October 1989 Resolved
WATERTIGHT DOOR BETWEEN GALLEY AND LOWER LOUNGE TO BE PERMANENTLY SEALED UNTIL THE DOOR IS SEALED IT MUST BE CLOSED AT ALL TIMES.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Documentation
Issued 6 October 1989 Resolved
PROVIDE AN INTERNATIONAL LOADLINE CERTIFICATE
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Navigation
Issued 30 May 1986 Resolved
VESSEL'S SIDE LIGHTS ARE TO BE RELOCATED TO A POSITION EVEN WITH, OR AFT OF THE MASTHEAD LIGHT, TO COMPLY WITH 72 COLREGS.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.