Records from 1985 to 2007. Most recent: inspection, 10 October 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
10 October 2007
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3076827
13 April 2006
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2623728
30 June 2004
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2115911
28 July 2003
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1859262
19 August 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1663357
19 June 2002
Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1633027
6 June 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1627062
2 July 2001
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1068490
22 May 2001
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1397593
10 June 2000
Plan Review "T" Boat · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1470243
28 May 1996
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1085522
18 July 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1186794
30 June 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1191528
27 April 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 860860
28 June 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 862641
18 May 1994
Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 862794
3 September 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829489
30 June 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829488
16 June 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 960658
22 August 1992
Damage Survey · Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 944975
8 May 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 951050
5 May 1992
Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952759
5 June 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 957736
25 October 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1241300
27 June 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942838
27 June 1990
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 956748
1 August 1989
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 913365
5 May 1989
COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1032998
11 May 1988
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1349608
8 September 1987
Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1329046
2 June 1987
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1329039
8 May 1986
Deficiency Check · COI Inspection · Credit Drydock
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1299385
29 April 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1288033
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 April 2006
No resolution recorded
COI has been deactivated.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2006 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Pump
Issued 30 June 2004
No resolution recorded
Prove proper operation of the fixed bilge system.
Due 2 July 2004 — due date passed with no resolution recorded
Lifesaving › Buoyant Apparatus
Issued 28 July 2003
Resolved
Properly install the lifefloats (03) in a float-free arrangement, grouped with one sea painter, IAW 46 CFR 180.137. Currently 2 rafts are not attached by any painter. Provide a weak link applicable to the stowage arrangment.
Condition: Improper Installation
Due 28 August 2003
Resolved 28 August 2003
Resolution: Done.
Lifesaving › Buoyant Apparatus
Issued 28 July 2003
Resolved
Make permenent repairs to the 3 inch cut in the Life-float. Approved self-patch kit is acceptable.
Condition: Damaged By Earlier Event
Due 28 August 2003
Resolved 28 August 2003
Resolution: Done.
Lifesaving › Buoyant Apparatus
Issued 28 July 2003
Resolved
Renew all oars IWO the life-floats. All oars are cracked and/or broken.
Condition: Improper/Lack of Maintenance
Due 28 August 2003
Resolved 28 August 2003
Resolution: Done.
Operations/Management › Navigation Safety
Issued 28 July 2003
Resolved
Provide up-to-date Coast Pilot and Tide Current information (exerpts). LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Improper/Lack of Maintenance
Due 28 August 2003
Resolved 28 August 2003
Resolution: Done.
Operations/Management › Equipment Service/Testing
Issued 28 July 2003
Resolved
Begin logging the safety equipment maintenance and inspections as required by 46 CFR 185.702.
Condition: Improper/Lack of Maintenance
Due 28 August 2003
Resolved 28 August 2003
Documentation › Logs/Records
Issued 28 July 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 28 August 2003
Resolved 28 August 2003
Resolution: Done.
Documentation › Certificates/Documents
Issued 28 July 2003
Resolved
Provide FCC Safety Certificate and Operators Permit.
Condition: Improper/Lack of Maintenance
Due 28 August 2003
Resolved 28 August 2003
Resolution: Done.
Electrical › Electric Supply System (service)
Issued 28 July 2003
Resolved
Provide battery terminal covers or battery covers IAW 46 CFR 183.350. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Due 28 August 2003
Resolved 28 August 2003
Resolution: Done.
Navigation › Collision/Grounding Avoidance
Issued 28 July 2003
Resolved
Remove current light configuration for "dive operations" and replace with one that meets COMDTINST M16672.2c, Annex I for vertical seperation. Vessel is limited to daylight dive operations, unless anchored. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Due 28 August 2003
Resolved 28 August 2003
Resolution: Done.
Stability › Weathertight Integrity
Issued 19 June 2002
Resolved
Repair lower cabin forward windows, so windows can be secured in the down position. LEGACY COMPONENT DESC: Forward Cabin Windows
Condition: Improper Installation
Due 27 June 2002
Resolved 5 August 2002
Engineering › Bilge Water Management System
Issued 6 June 2002
Resolved
Repair leak in bilge pump hose in fuel tank compartment. LEGACY COMPONENT DESC: Hose
Due 13 June 2002
Resolved 19 June 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 6 June 2002
Resolved
Provide a continuity wire between the fuel tank and deck fill fittings. LEGACY COMPONENT DESC: Piping
Due 13 June 2002
Resolved 19 June 2002
Electrical › Lighting (service)
Issued 6 June 2002
Resolved
Re-attach the lighting fixture on the sewage tank compartment. LEGACY COMPONENT DESC: Lighting Fixture
Due 13 June 2002
Resolved 19 June 2002
Navigation › Piloting/Steering
Issued 6 June 2002
Resolved
Provide all navigation pubs. LEGACY COMPONENT DESC: US Coast Pilot
Due 13 June 2002
Resolved 6 June 2002
Stability › Watertight Integrity
Issued 6 June 2002
Resolved
Provide a line on the fwd hatch.
Due 13 June 2002
Resolved 19 June 2002
Operations/Management › Drug and Alcohol Testing
Issued 6 June 2002
Resolved
Provide proof that all items indicated under the chemical testing program checklist are in compliance. LEGACY COMPONENT DESC: MIS Submission
Due 13 June 2002
Resolved 19 June 2002
Construction/Loadline
Issued 30 June 1995
Resolved
Replace frame (rotted) on forward hatch and resecure latch mechanism.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Lifesaving
Issued 30 June 1995
Resolved
Replace seapainter on lifefloat.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Lifesaving
Issued 27 April 1995
Resolved
Replace deteriorated lanyard to waterlight on lifefloat.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Lifesaving
Issued 27 April 1995
Resolved
Repair chips in buoyant apparatus.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Accommodation/Occupational Safety
Issued 27 April 1995
Resolved
Stencil Maximum number of persons allowed on ladder leading to upper deck._x001C__x001C_ "MAX 7 PERSONS"
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Construction/Loadline
Issued 27 April 1995
Resolved
Repair locking mechanisms on forward hatches.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Fire Fighting
Issued 27 April 1995
Resolved
Service all fire extinguishers prior to operation of vessel.
Condition: Unknown
Due 27 May 1995
Resolved 11 May 1995
Construction/Loadline
Issued 18 May 1994
Resolved
Replace deteriorated sampson post.
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994
Documentation
Issued 18 May 1994
Resolved
Post missing page of stability letter.
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994
Lifesaving
Issued 18 May 1994
Resolved
Provide Two missing 4' paddles for lifefloat. This item shall be accomplished prior to carriage of passengers.
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994
Lifesaving
Issued 18 May 1994
Resolved
Repair or replace inoperable waterlights on lifefloat and buoyant apparatus. This requirement shall be accomplished prior to carriage of passengers.
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994
Lifesaving
Issued 16 June 1993
Resolved
Restencil lifejacket stowage to reflect the actual number of lifejackets stowed aboard.
Condition: Unknown
Due 16 July 1993
Resolved 4 September 1993
Construction/Loadline
Issued 16 June 1993
Resolved
Make permenant repairs to fracture/seperation in way of stern deck at knuckle to prevent further propagation.
Condition: Unknown
Due 1 September 1993
Resolved 4 September 1993
Documentation
Issued 16 June 1993
Resolved
Vessel operation is limited to 1000 feet from shore while passengers are aboard until a valid radio safety certificate is obtained from the Federal Communications Commission.
Condition: Unknown
Due 16 July 1993
Resolved 4 September 1993
Construction/Loadline
Issued 22 August 1992
Resolved
SUBMIT DETAILED REPAIR PROPOSAL FOR APPROVAL TO MSO MIAMI.
Condition: Unknown
Due 22 September 1992
Resolved 19 September 1992
Construction/Loadline
Issued 22 August 1992
Resolved
UPON COMPLETION OF REPAIRS, CONDUCT AN UNDERWAY OPERATIONAL TEST OF MAIN ENGINES AND STEERING IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 22 September 1992
Resolved 19 September 1992
Construction/Loadline
Issued 22 August 1992
Resolved
EFFECT PERMANENT REPAIRS TO STBD. RUDDER, PROPELLER, SHAFT, STRUT AND HULL IN WAY OF RUDDER PACKING GLAND AND SHAFT STRUT, AND STEERING SYSTEM. IN ACCORDANCE WITH THE APPROVED REPAIR PROCEDURE.
Condition: Unknown
Due 22 September 1992
Resolved 19 September 1992
Lifesaving
Issued 8 May 1992
Resolved
PLACE ON BOARD 5 ADULT PFD'S AND 2 CHILDRENS. VESSEL IS LIMITED TO 48 TOTAL PERSONS WITH NO MORE THAN 4 CHILDREN INCLUDED UNTIL NEW PFD'S ARE PLACED ON BOARD.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Construction/Loadline
Issued 5 May 1989
Resolved
PROVIDE HAND GRIP/HOLD FOR SAFE ACCESS TO TOP OF WHEELHOUSE.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Fire Fighting
Issued 5 May 1989
Resolved
HAVE ALL FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Construction/Loadline
Issued 5 May 1989
Resolved
SCRAPE AND TREAT FUZZY WOOD IN ENGINE COMPARTMENT.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Construction/Loadline
Issued 5 May 1989
Resolved
RELABEL FUEL SHUT-OFF VALVES IN AT LEAST 1 INCH LETTERS.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Construction/Loadline
Issued 5 May 1989
Resolved
PROVIDE INSPECTION PORT IN DECK IN NUMBER 1 COMPARTMENT(FWD OF COLLOISION BULKHEAD).
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Engineering
Issued 5 May 1989
Resolved
REPLACE FLEXIBLE FUEL LINES, BOTH SUPPLY AND RETURN, WITH COPPER FUEL LINESHAVING A MINIMUM WALL THICKNESS OF 0.035 INCH.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Construction/Loadline
Issued 5 May 1989
Resolved
CROP BACK ROTTEN WOOD TO GOOD WOOD AND REPLACE IN KIND IN FORWARD BULKHEAD OF NUMBER 3 COMPARTMENT.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Construction/Loadline
Issued 5 May 1989
Resolved
REPAIR WEAK SPOTS IN DECK IN NUMBER 2 COMPARTMENT.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Construction/Loadline
Issued 5 May 1989
Resolved
PROVIDE FORWARD INSPECTION PORT IN DECK IN NUMBER 2 COMPARTMENT.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Fire Fighting
Issued 5 May 1989
Resolved
RELOCATE ENGINE ROOM FIRE EXTINGUISHER TO BE MORE ACCESSIBLE.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Construction/Loadline
Issued 5 May 1989
Resolved
REPLACE VENT SCOOPS TO ENGINE COMPARTMENT.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Deck/Cargo
Issued 5 May 1989
Resolved
REMOVE CHAFED SPOT IN ANCHOR LINE.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Lifesaving
Issued 5 May 1989
Resolved
PROVIDE 6 ORANGE HAND FLARES.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Lifesaving
Issued 5 May 1989
Resolved
RENEW PAINTER TO LIFE FLOAT.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989