MAURY USCG vessel records Sign in
← All vessels

CATANO II

CATANO II is a 1975 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 1985, most recently in July 1998, along with 70 deficiencies.

Records from 1985 to 1998. Most recent: inspection, 20 July 1998.

Built
1975
Last inspected
20 July 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYN4124
Flag
UNITED STATES
—
Maury page id
psix-48569

Inspections, by type

…with no type recorded11
Years with a record 14 calendar years (1985–1998)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBR4892MMSI not assigned · expired · compulsorily equipped · granted 17 February 1998, cancelled 17 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SAN GERONIMO Passenger (Inspected) · MISLE 342701 · 22 June 1993 · activity 145208

Inspection history · 41

20 July 1998 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 797949
2 July 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1407924
25 October 1996 COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1425812
25 January 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1189813
23 October 1995 COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360187
6 June 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 874915
29 March 1995 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1142971
28 November 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1175996
9 November 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1439566
29 August 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363028
14 June 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1431376
1 April 1994 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 856681
31 March 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 855567
6 December 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850023
2 July 1993 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1395958
22 June 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 145208
28 April 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 833083
11 March 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1422209
9 March 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1146521
1 October 1992 Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1267114
9 June 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1268411
7 May 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 944224
8 April 1992 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1265106
30 May 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1220375
11 April 1991 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 998699
15 November 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1238808
28 March 1990 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1232479
1 March 1990 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 915548
11 February 1990 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 908498
25 January 1990 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1219992
12 April 1989 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 894049
21 September 1988 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1195990
17 August 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1037599
16 June 1988 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1034158
14 April 1988 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1032085
27 March 1987 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1005605
2 July 1986 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1306604
14 March 1986 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1305740
2 April 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 985883
5 March 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1286081
6 February 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 977484

Deficiency record · 70

Electrical
Issued 25 October 1996 Resolved
REPLACE MISSING FLUORESCENT LIGHT FIXTURE COVER IN ENGINE ROOM.
Condition: Unknown
Due 15 November 1996
Resolved 6 November 1996
Fire Fighting
Issued 25 October 1996 Resolved
RENEW OR REPAIR MALFUNCTIONING FIRE PUMP DISCHARGE PRESSURE GAUGE.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Navigation
Issued 25 October 1996 Resolved
ENSURE PORT STEERING GEAR CONTROL CABLE DOES NOT CHAFF AGAINST CORRODED DECK PLATING IN WAY OF #3 COMPARTMENT WHERE CABLE PASSES THROUGH MAIN DECK.
Condition: Unknown
Due 15 November 1996
Resolved 6 November 1996
Electrical
Issued 25 October 1996 Resolved
REPLACE MISSING COVER FOR ELECTRICAL PANEL ON BRIDGE.
Condition: Unknown
Due 15 November 1996
Resolved 6 November 1996
Engineering
Issued 25 October 1996 Resolved
REPAIR OR RENEW WASTED HANDWHEEL ON FUEL TANK REMOTE SHUT OFF VALVE.
Condition: Unknown
Due 15 November 1996
Resolved 6 November 1996
Engineering
Issued 23 October 1995 Resolved
PROVE PROPER OPERATION OF THE PORT AND STBD MAIN ENGINE TACHOMETERS.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Engineering
Issued 9 November 1994 Resolved
MAKE PERMANENT REPAIRS TO SEA SUCTION PIPE, PORT MAIN DIESEL ENGINE AT INLET TO SEA STRAINER.
Condition: Unknown
Due 9 November 1994
Resolved 29 November 1994
Engineering
Issued 9 November 1994 Resolved
MAKE PERMANENT REPAIRS TO MULTIPLE LUBE OIL LEAKS ON STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 9 November 1994
Resolved 29 November 1994
Construction/Loadline
Issued 9 November 1994 Resolved
REMOVE ACCUMULATION OF WATER, DIESEL FUEL AND LUBE OIL FROM DRIP PANS, BILGES AND THROUGHOUT ENGINE ROOM.
Condition: Unknown
Due 9 November 1994
Resolved 29 November 1994
Engineering
Issued 9 November 1994 Resolved
MAKE PERMANENT REPAIRS TO EXHAUST LEAKS ON BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 9 November 1994
Resolved 29 November 1994
Construction/Loadline
Issued 29 August 1994 Resolved
CROP OUT AND RENEW ACCESS COMBING AND ATTACHED DECK LONGITUDINAL FRAMES AT AFTER STEERING COMPARTMENT.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Electrical
Issued 29 August 1994 Resolved
Install covers on all light fixtures where missing.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994 Resolved
REPAIR 3" X 4" HOLE IN MAIN DECK, STARBOARD AT FORWARD BULKHEAD OF #5 VOID.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994 Resolved
REPAIR 18" X 1" OPENING IN SIDE SHELL AT MAIN DECK, PORT SIDE IN WAY OF TURN TO TRANSOM.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994 Resolved
REPAIR 18" X 1" OPENING IN SIDE SHELL AT MAIN DECK, STARBOARD SIDE IN WAY OF TURN TO TRANSOM.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994 Resolved
RENEW LOWER PORTION OF FORWARD STEERING COMPARTMENT BULKHEAD AND ATTACHED VERTICAL STIFFENERS.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994 Resolved
RENEW WASTED PORT/STARBOARD RUBRAILS AND ADJOINING PLATE.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994 Resolved
MECHANICALLY CLEAN AND SCALE BOTTOM PLATING IN VOIDS 2, 3, 5 AND 6. PROVIDEAUDIO GAUGING IN AREAS TO BE DETERMINED BY ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Documentation
Issued 29 August 1994 Resolved
Place on board the following publications: Coast Pilot [name withheld] and TideTable.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Lifesaving
Issued 29 August 1994 Resolved
Properly attach lines to water lights and attach to buoyant apparatus.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Fire Fighting
Issued 29 August 1994 Resolved
Provide one additional B-II fire extinguisher to bring total on board to five.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Lifesaving
Issued 29 August 1994 Resolved
Install placard at access to upper deck limiting passengers on upper deck to the number of seats on the upper deck.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Construction/Loadline
Issued 29 August 1994 Resolved
CLEAN, SERVICE AND PROVE PROPER OPERATION OF MECHANICAL VOID ACCESS COVERS FOR VOID #3, ENGINE ROOM, VOID #5 AND #6.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Navigation
Issued 29 August 1994 Resolved
Remove loose depth finder wires.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Navigation
Issued 29 August 1994 Resolved
Properly adjust chain on rudder angle indicator.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Engineering
Issued 29 August 1994 Resolved
Fabricate and install guards on exposed moving pulleys in engine room.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Electrical
Issued 29 August 1994 Resolved
Remove dead end and unused wiring under control panel on bridge.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Documentation
Issued 29 August 1994 Resolved
Post pollution placards in engine room.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Accommodation/Occupational Safety
Issued 29 August 1994 Resolved
Display emergency check-off list in Spanish.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Accommodation/Occupational Safety
Issued 14 June 1994 Resolved
MAKE PROPER, PERMANENT REPAIRS TO SECOND DECK HAND RAIL GATE, AFT.
Condition: Unknown
Due 15 June 1994
Resolved 5 July 1994
Lifesaving
Issued 14 June 1994 Resolved
PROPERLY INSTALL ALL BUOYANT APPARATUS AND MAKE ATTACHED LINES AND LANYARDSFREE TO OPERATE WITHOUT BEING FOULED.
Condition: Unknown
Due 15 June 1994
Resolved 5 July 1994
Lifesaving
Issued 14 June 1994 Resolved
PROVE PROPER OPERATION OF ALL BUOYANT APPARATUS FLOAT LIGHTS.
Condition: Unknown
Due 15 June 1994
Resolved 5 July 1994
Documentation
Issued 2 July 1993 Resolved
Provide current certificate of documentation.
Condition: Unknown
Due 15 July 1993
Resolved 1 November 1993
Lifesaving
Issued 2 July 1993 Resolved
Provide proper pyrotechnic distress signals prior to carrying passengers. Vessel is restricted to Bahia de San Juan until requirement is cleared.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Fire Fighting
Issued 2 July 1993 Resolved
Provide 3 properly hydrostatic-tested portable BII fire extinguishers priorto carrying passengers on board.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Lifesaving
Issued 2 July 1993 Resolved
Provide proper metal guards and glass globes for lights in engine room.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Electrical
Issued 2 July 1993 Resolved
Install proper lining on both battery boxes in engine rooms.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Lifesaving
Issued 2 July 1993 Resolved
Provide letter designating a senior deckhand as required by COI and prove crew to be properly trained in emergency situations.
Condition: Unknown
Due 2 July 1993
Resolved 15 July 1993
Electrical
Issued 2 July 1993 Resolved
Ensure electrical circuit breakers are properly covered in both pilot housebreaker panels.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Construction/Loadline
Issued 11 March 1993 Resolved
CROP OUT WASTED STEEL AND INSERT SIDE SHELL PLATE IN WAY OF PORT FUEL OIL TANK AND MAIN DECK.
Condition: Unknown
Due 1 November 1993
Resolved 1 November 1993
Engineering
Issued 8 April 1992 Resolved
PROVIDE LAGGING FOR EXHAUST PIPE FOR GENERATOR.
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Fire Fighting
Issued 8 April 1992 Resolved
STENCIL VESSEL'S NAME ON FIRE AXE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Navigation
Issued 8 April 1992 Resolved
PROVIDE MASTHEAD LIGHT FOR VESSEL WHICH MEETS ALL REQUIREMENTS OF THE INT'LRULES OF THE ROAD IN REGARDS TO POSITIONING, ARC OF VISIBILITY, RANGE OF VISIBILTY, ETC. UNTIL THIS TIME THE VESSEL SHALL NOT BE UNDERWAY BETWEEN SUNSET AND SUNRISE._x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Engineering
Issued 8 April 1992 Resolved
PROVE PROPER OPERATION OF RPM GAUGE FOR PORT MAIN DIESEL ENGINE. (NOTE: THE GAUGE LOCATED ON ENGINE).
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Electrical
Issued 8 April 1992 Resolved
PROVIDE DIRECTORY FOR ALL ELECTRICAL PANELS THROUGHOUT VESSEL_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 8 April 1992 Resolved
PROVIDE WATERTIGHT CONTAINER FOR PYROTECHNIC DISTRESS SIGNALS.
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 8 April 1992 Resolved
REPLACE GRABLINES ON LIFERINGS LOCATED ON PORT AND STARBOARD SIDE OF WHEELHOUSE.
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 8 April 1992 Resolved
PROVIDE SPACERS TO SEPARATE BUOYANT APPARATUS' WHICH ARE STOWED IN TIERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 8 April 1992 Resolved
STENCIL 12 PERSON BA WITH VSL's NAME AND PERSON CAPACITY. REMOVE STENCIL THAT SAYS 20 PERSONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 30 May 1991 Resolved
INSTALL THREE (3) WEAKLINKS ON VESSEL EACH HAVING THE PROPER BREAKING STRENTH FOR THE COMBINED BUOYANT APPARATUS LOAD IAW 46 CFR 180.20- 1(a)(5)(iii)._x001C_ _x001C_
Condition: Unknown
Due 30 May 1991
Resolved 30 May 1991
Lifesaving
Issued 30 May 1991 Resolved
PROVIDE RESCUE LADDER FOR MAN OVERBOARD EVOLUTIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1991
Resolved 30 May 1991
Engineering
Issued 14 April 1988 Resolved
ADJUST PROPELLER SHAFT PACKING
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988 Resolved
MAKE THE S/S GENERATOR OVERSPEED TRIP OPERATIONAL (1300-1500 RPM).
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 14 April 1988 Resolved
REMOVE RUST AND SCALE FROM LONGITUDINALS IN ENGINEROOM JUST OUTBOARD OF #1 MDE (STARBOARD). DETERMINE WASTAGE - REPLACE ALL LONGITUDINALS IF WASTED BEYOND 25% OF ORIGINAL.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 14 April 1988 Resolved
MAKE REPAIRS PORT AND STARBOARD RUBRAILS AS MARKED AND BACK TO GOOD METAL.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 14 April 1988 Resolved
#3 HOLD - ONE WELD PICK UP ON STARBOARD SIDE MARKED. MAKE MAN HOLE COVER WATERTIGHT AT GASKET.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988 Resolved
RENEW BATTERY CABLES AS NEEDED
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988 Resolved
TIGHTEN ELECTRICAL CONNECTIONS AT VARIOUS PLACES THROUGHOUT ENGINEROONM.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Unknown
Issued 14 April 1988 Resolved
REMOVE EXCESS OIL FROM ENGINEROOM BILGES.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Fire Fighting
Issued 14 April 1988 Resolved
RELOCATE FWD FIRE EXTINGUISHER IN ENGINEROOM CLOSER TO DECK.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Navigation
Issued 14 April 1988 Resolved
PLACE PROPER SHIELD ON STERN LIGHT TO COMPLY WITH COLREGS.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Lifesaving
Issued 14 April 1988 Resolved
VESSEL IS REQUIRED TO HAVE LIFE FLOATS AVAILABLE EITHER ONBOARD OR IN STORAGE FOR INSPECTION IF SHE INTENDS TO KEEP HER COASTWISE ROUTE. AT PRE-SENT THE BA HAVE NOT BEEN INSPECTED AND THE VESSEL IS CONFINED TO SAN JUAN HARBOR.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Lifesaving
Issued 6 February 1985 Resolved
PROVIDE ONE RING BUOY WITH 60 FEET OF LINE. LOCATION PORTSIDE OF THE WHEELHOUSE
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Unknown
Issued 6 February 1985 Resolved
MAKE THE FOREPEAK BILGE SUCTION VALVE OPERATIONAL FROM THE MAIN DECK.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Fire Fighting
Issued 6 February 1985 Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER FOR THE UPPER DECK PASSENGER AREA.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Construction/Loadline
Issued 6 February 1985 Resolved
MAKE PERMANENT REPAIRS TO RUB RAILS WHERE FRACTURED AND WASTED.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Electrical
Issued 6 February 1985 Resolved
REPLACE MISSING LIGHT GLOBES AND GUARDS THROUGHOUT THE VESSEL
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Fire Fighting
Issued 6 February 1985 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Engineering
Issued 6 February 1985 Resolved
RELABEL EMERGENCY FUEL OIL SHUTOFF VALVES SO THAT THEY CAN BE MORE READILY SEEN.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Fire Fighting
Issued 6 February 1985 Resolved
REPAIR AND REPLACE THE FIRE PUMP PORTSIDE OF THE ENGINE ROOM. TEST THE OPERATION OF THE PUMP WITH A MARINE INSPECTOR PRESENT
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985

Ownership record