Records from 1985 to 1998. Most recent: inspection, 20 July 1998.
Inspection history · 41
20 July 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 797949
2 July 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1407924
25 October 1996
COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1425812
25 January 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1189813
23 October 1995
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360187
6 June 1995
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 874915
29 March 1995
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1142971
28 November 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1175996
9 November 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1439566
29 August 1994
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363028
14 June 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1431376
1 April 1994
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 856681
31 March 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 855567
6 December 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850023
2 July 1993
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1395958
22 June 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 145208
28 April 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 833083
11 March 1993
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1422209
9 March 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1146521
1 October 1992
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1267114
9 June 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1268411
7 May 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 944224
8 April 1992
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1265106
30 May 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1220375
11 April 1991
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 998699
15 November 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1238808
28 March 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1232479
1 March 1990
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 915548
11 February 1990
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 908498
25 January 1990
Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1219992
12 April 1989
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 894049
21 September 1988
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1195990
17 August 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1037599
16 June 1988
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1034158
14 April 1988
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1032085
27 March 1987
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1005605
2 July 1986
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1306604
14 March 1986
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1305740
2 April 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 985883
5 March 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1286081
6 February 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 977484
Electrical
Issued 25 October 1996
Resolved
REPLACE MISSING FLUORESCENT LIGHT FIXTURE COVER IN ENGINE ROOM.
Condition: Unknown
Due 15 November 1996
Resolved 6 November 1996
Fire Fighting
Issued 25 October 1996
Resolved
RENEW OR REPAIR MALFUNCTIONING FIRE PUMP DISCHARGE PRESSURE GAUGE.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Navigation
Issued 25 October 1996
Resolved
ENSURE PORT STEERING GEAR CONTROL CABLE DOES NOT CHAFF AGAINST CORRODED DECK PLATING IN WAY OF #3 COMPARTMENT WHERE CABLE PASSES THROUGH MAIN DECK.
Condition: Unknown
Due 15 November 1996
Resolved 6 November 1996
Electrical
Issued 25 October 1996
Resolved
REPLACE MISSING COVER FOR ELECTRICAL PANEL ON BRIDGE.
Condition: Unknown
Due 15 November 1996
Resolved 6 November 1996
Engineering
Issued 25 October 1996
Resolved
REPAIR OR RENEW WASTED HANDWHEEL ON FUEL TANK REMOTE SHUT OFF VALVE.
Condition: Unknown
Due 15 November 1996
Resolved 6 November 1996
Engineering
Issued 23 October 1995
Resolved
PROVE PROPER OPERATION OF THE PORT AND STBD MAIN ENGINE TACHOMETERS.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Engineering
Issued 9 November 1994
Resolved
MAKE PERMANENT REPAIRS TO SEA SUCTION PIPE, PORT MAIN DIESEL ENGINE AT INLET TO SEA STRAINER.
Condition: Unknown
Due 9 November 1994
Resolved 29 November 1994
Engineering
Issued 9 November 1994
Resolved
MAKE PERMANENT REPAIRS TO MULTIPLE LUBE OIL LEAKS ON STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 9 November 1994
Resolved 29 November 1994
Construction/Loadline
Issued 9 November 1994
Resolved
REMOVE ACCUMULATION OF WATER, DIESEL FUEL AND LUBE OIL FROM DRIP PANS, BILGES AND THROUGHOUT ENGINE ROOM.
Condition: Unknown
Due 9 November 1994
Resolved 29 November 1994
Engineering
Issued 9 November 1994
Resolved
MAKE PERMANENT REPAIRS TO EXHAUST LEAKS ON BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 9 November 1994
Resolved 29 November 1994
Construction/Loadline
Issued 29 August 1994
Resolved
CROP OUT AND RENEW ACCESS COMBING AND ATTACHED DECK LONGITUDINAL FRAMES AT AFTER STEERING COMPARTMENT.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Electrical
Issued 29 August 1994
Resolved
Install covers on all light fixtures where missing.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994
Resolved
REPAIR 3" X 4" HOLE IN MAIN DECK, STARBOARD AT FORWARD BULKHEAD OF #5 VOID.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994
Resolved
REPAIR 18" X 1" OPENING IN SIDE SHELL AT MAIN DECK, PORT SIDE IN WAY OF TURN TO TRANSOM.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994
Resolved
REPAIR 18" X 1" OPENING IN SIDE SHELL AT MAIN DECK, STARBOARD SIDE IN WAY OF TURN TO TRANSOM.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994
Resolved
RENEW LOWER PORTION OF FORWARD STEERING COMPARTMENT BULKHEAD AND ATTACHED VERTICAL STIFFENERS.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994
Resolved
RENEW WASTED PORT/STARBOARD RUBRAILS AND ADJOINING PLATE.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Construction/Loadline
Issued 29 August 1994
Resolved
MECHANICALLY CLEAN AND SCALE BOTTOM PLATING IN VOIDS 2, 3, 5 AND 6. PROVIDEAUDIO GAUGING IN AREAS TO BE DETERMINED BY ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Documentation
Issued 29 August 1994
Resolved
Place on board the following publications: Coast Pilot [name withheld] and TideTable.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Lifesaving
Issued 29 August 1994
Resolved
Properly attach lines to water lights and attach to buoyant apparatus.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Fire Fighting
Issued 29 August 1994
Resolved
Provide one additional B-II fire extinguisher to bring total on board to five.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Lifesaving
Issued 29 August 1994
Resolved
Install placard at access to upper deck limiting passengers on upper deck to the number of seats on the upper deck.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Construction/Loadline
Issued 29 August 1994
Resolved
CLEAN, SERVICE AND PROVE PROPER OPERATION OF MECHANICAL VOID ACCESS COVERS FOR VOID #3, ENGINE ROOM, VOID #5 AND #6.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Navigation
Issued 29 August 1994
Resolved
Remove loose depth finder wires.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Navigation
Issued 29 August 1994
Resolved
Properly adjust chain on rudder angle indicator.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Engineering
Issued 29 August 1994
Resolved
Fabricate and install guards on exposed moving pulleys in engine room.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Electrical
Issued 29 August 1994
Resolved
Remove dead end and unused wiring under control panel on bridge.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Documentation
Issued 29 August 1994
Resolved
Post pollution placards in engine room.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Accommodation/Occupational Safety
Issued 29 August 1994
Resolved
Display emergency check-off list in Spanish.
Condition: Unknown
Due 29 September 1994
Resolved 8 November 1994
Accommodation/Occupational Safety
Issued 14 June 1994
Resolved
MAKE PROPER, PERMANENT REPAIRS TO SECOND DECK HAND RAIL GATE, AFT.
Condition: Unknown
Due 15 June 1994
Resolved 5 July 1994
Lifesaving
Issued 14 June 1994
Resolved
PROPERLY INSTALL ALL BUOYANT APPARATUS AND MAKE ATTACHED LINES AND LANYARDSFREE TO OPERATE WITHOUT BEING FOULED.
Condition: Unknown
Due 15 June 1994
Resolved 5 July 1994
Lifesaving
Issued 14 June 1994
Resolved
PROVE PROPER OPERATION OF ALL BUOYANT APPARATUS FLOAT LIGHTS.
Condition: Unknown
Due 15 June 1994
Resolved 5 July 1994
Documentation
Issued 2 July 1993
Resolved
Provide current certificate of documentation.
Condition: Unknown
Due 15 July 1993
Resolved 1 November 1993
Lifesaving
Issued 2 July 1993
Resolved
Provide proper pyrotechnic distress signals prior to carrying passengers. Vessel is restricted to Bahia de San Juan until requirement is cleared.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Fire Fighting
Issued 2 July 1993
Resolved
Provide 3 properly hydrostatic-tested portable BII fire extinguishers priorto carrying passengers on board.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Lifesaving
Issued 2 July 1993
Resolved
Provide proper metal guards and glass globes for lights in engine room.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Electrical
Issued 2 July 1993
Resolved
Install proper lining on both battery boxes in engine rooms.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Lifesaving
Issued 2 July 1993
Resolved
Provide letter designating a senior deckhand as required by COI and prove crew to be properly trained in emergency situations.
Condition: Unknown
Due 2 July 1993
Resolved 15 July 1993
Electrical
Issued 2 July 1993
Resolved
Ensure electrical circuit breakers are properly covered in both pilot housebreaker panels.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Construction/Loadline
Issued 11 March 1993
Resolved
CROP OUT WASTED STEEL AND INSERT SIDE SHELL PLATE IN WAY OF PORT FUEL OIL TANK AND MAIN DECK.
Condition: Unknown
Due 1 November 1993
Resolved 1 November 1993
Engineering
Issued 8 April 1992
Resolved
PROVIDE LAGGING FOR EXHAUST PIPE FOR GENERATOR.
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Fire Fighting
Issued 8 April 1992
Resolved
STENCIL VESSEL'S NAME ON FIRE AXE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Navigation
Issued 8 April 1992
Resolved
PROVIDE MASTHEAD LIGHT FOR VESSEL WHICH MEETS ALL REQUIREMENTS OF THE INT'LRULES OF THE ROAD IN REGARDS TO POSITIONING, ARC OF VISIBILITY, RANGE OF VISIBILTY, ETC. UNTIL THIS TIME THE VESSEL SHALL NOT BE UNDERWAY BETWEEN SUNSET AND SUNRISE._x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Engineering
Issued 8 April 1992
Resolved
PROVE PROPER OPERATION OF RPM GAUGE FOR PORT MAIN DIESEL ENGINE. (NOTE: THE GAUGE LOCATED ON ENGINE).
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Electrical
Issued 8 April 1992
Resolved
PROVIDE DIRECTORY FOR ALL ELECTRICAL PANELS THROUGHOUT VESSEL_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 8 April 1992
Resolved
PROVIDE WATERTIGHT CONTAINER FOR PYROTECHNIC DISTRESS SIGNALS.
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 8 April 1992
Resolved
REPLACE GRABLINES ON LIFERINGS LOCATED ON PORT AND STARBOARD SIDE OF WHEELHOUSE.
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 8 April 1992
Resolved
PROVIDE SPACERS TO SEPARATE BUOYANT APPARATUS' WHICH ARE STOWED IN TIERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 8 April 1992
Resolved
STENCIL 12 PERSON BA WITH VSL's NAME AND PERSON CAPACITY. REMOVE STENCIL THAT SAYS 20 PERSONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1992
Resolved 18 May 1992
Lifesaving
Issued 30 May 1991
Resolved
INSTALL THREE (3) WEAKLINKS ON VESSEL EACH HAVING THE PROPER BREAKING STRENTH FOR THE COMBINED BUOYANT APPARATUS LOAD IAW 46 CFR 180.20- 1(a)(5)(iii)._x001C_ _x001C_
Condition: Unknown
Due 30 May 1991
Resolved 30 May 1991
Lifesaving
Issued 30 May 1991
Resolved
PROVIDE RESCUE LADDER FOR MAN OVERBOARD EVOLUTIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1991
Resolved 30 May 1991
Engineering
Issued 14 April 1988
Resolved
ADJUST PROPELLER SHAFT PACKING
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988
Resolved
MAKE THE S/S GENERATOR OVERSPEED TRIP OPERATIONAL (1300-1500 RPM).
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 14 April 1988
Resolved
REMOVE RUST AND SCALE FROM LONGITUDINALS IN ENGINEROOM JUST OUTBOARD OF #1 MDE (STARBOARD). DETERMINE WASTAGE - REPLACE ALL LONGITUDINALS IF WASTED BEYOND 25% OF ORIGINAL.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 14 April 1988
Resolved
MAKE REPAIRS PORT AND STARBOARD RUBRAILS AS MARKED AND BACK TO GOOD METAL.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 14 April 1988
Resolved
#3 HOLD - ONE WELD PICK UP ON STARBOARD SIDE MARKED. MAKE MAN HOLE COVER WATERTIGHT AT GASKET.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988
Resolved
RENEW BATTERY CABLES AS NEEDED
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Electrical
Issued 14 April 1988
Resolved
TIGHTEN ELECTRICAL CONNECTIONS AT VARIOUS PLACES THROUGHOUT ENGINEROONM.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Unknown
Issued 14 April 1988
Resolved
REMOVE EXCESS OIL FROM ENGINEROOM BILGES.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Fire Fighting
Issued 14 April 1988
Resolved
RELOCATE FWD FIRE EXTINGUISHER IN ENGINEROOM CLOSER TO DECK.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Navigation
Issued 14 April 1988
Resolved
PLACE PROPER SHIELD ON STERN LIGHT TO COMPLY WITH COLREGS.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Lifesaving
Issued 14 April 1988
Resolved
VESSEL IS REQUIRED TO HAVE LIFE FLOATS AVAILABLE EITHER ONBOARD OR IN STORAGE FOR INSPECTION IF SHE INTENDS TO KEEP HER COASTWISE ROUTE. AT PRE-SENT THE BA HAVE NOT BEEN INSPECTED AND THE VESSEL IS CONFINED TO SAN JUAN HARBOR.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Lifesaving
Issued 6 February 1985
Resolved
PROVIDE ONE RING BUOY WITH 60 FEET OF LINE. LOCATION PORTSIDE OF THE WHEELHOUSE
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Unknown
Issued 6 February 1985
Resolved
MAKE THE FOREPEAK BILGE SUCTION VALVE OPERATIONAL FROM THE MAIN DECK.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Fire Fighting
Issued 6 February 1985
Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER FOR THE UPPER DECK PASSENGER AREA.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Construction/Loadline
Issued 6 February 1985
Resolved
MAKE PERMANENT REPAIRS TO RUB RAILS WHERE FRACTURED AND WASTED.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Electrical
Issued 6 February 1985
Resolved
REPLACE MISSING LIGHT GLOBES AND GUARDS THROUGHOUT THE VESSEL
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Fire Fighting
Issued 6 February 1985
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Engineering
Issued 6 February 1985
Resolved
RELABEL EMERGENCY FUEL OIL SHUTOFF VALVES SO THAT THEY CAN BE MORE READILY SEEN.
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985
Fire Fighting
Issued 6 February 1985
Resolved
REPAIR AND REPLACE THE FIRE PUMP PORTSIDE OF THE ENGINE ROOM. TEST THE OPERATION OF THE PUMP WITH A MARINE INSPECTOR PRESENT
Condition: Unknown
Due 6 February 1985
Resolved 6 February 1985