Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Documentation record
Registered dimensions (L × B × D)54.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA ARK MARINE INC · MONTICELLO, AR, UNITED STATES · built 1998
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portRIVERHEAD, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
27 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8357655
13 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8133200
19 November 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8037078
11 October 2024
Examination of Repairs · Administrative Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8024011
9 May 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7909868
25 March 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7884731
29 June 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7726193
22 November 2022
Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7600465
31 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7427154
21 March 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7415555
28 April 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7183679
8 December 2020
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6940425
11 June 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6910786
12 March 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6910787
1 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6773295
9 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6342110
26 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6342106
16 March 2017
Deficiency Check · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6106174
28 April 2016
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5864423
24 March 2016
Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5839494
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 13 May 2025
Resolved
Provide a copy of the CG approved beaching plan onboard the vessel.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 13 May 2025
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2024
Resolved
Although vessel has more than the required amount of child size PFDs, a special note from a previous inspection stated to be on the lookout for rot. The vessel has approx 50-70 child size PFDs as it conducts many school trips. Approx 20 child size PFDs were dry rotted to the point the foam buoyancy material was reduced to dust when lightly squeezed. Many of these PFDs were from the early 1990s and they are stored in the overhead, which is a one piece canvas top and exposed to the elements, sun and heat cycles of many years.
After checking and condemning multiple PFDs, issued requirement to replace all remaining child PFDs of that era/design prior to the carriage of children exceeding serviceable PFDs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2024
Resolved 21 May 2024
Resolution: 15 child size PFDs replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2021
Resolved
The water light was not of the approved type. The waterlight had an on/off switch and could not turn on automatically when inverted.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 6 May 2021
Resolution: Approved waterlight installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 April 2021
Resolved
Vessel consortium list was not available.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 6 May 2021
Resolution: Proof of enrollment provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 April 2021
Resolved
Vessel's first aid kit was missing/expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 6 May 2021
Resolution: First aid kit items replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 March 2020
Resolved
Prior to operating with passengers after 15OCT2020 effect repairs to the identified areas of wasted metal on the outmost longitudinal frame behind where the rub rail attaches, to the satisfaction of the attending Marine Inspector. 46CFR176.600
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2020
Resolved 26 March 2021
Resolution: Sat installed outermost longitudinal frame.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 April 2017
Resolved
Provide one adult PFD to bring total PFD's to 78. Vessel is restricted to 77 total persons.
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 4 May 2017
Resolution: provided
Communications › Radio Communications › VHF Radiotelephone
Issued 19 April 2017
Resolved
Provide DSC Capable radio at operating station & Program in vessels MMSI #.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 4 May 2017
Resolution: provided and updated with MMSI
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 19 April 2017
Resolved
Provide copy of results from the last Random Drug Test.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 7 June 2017
Resolution: Copy of last randoms provided.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 19 April 2017
Resolved
Provide copy of results for Pre-employment testing.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 7 June 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 19 April 2017
Resolved
Provide proof of supervisor EAP training.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 30 June 2017
Resolution: Provided
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 April 2016
Resolved
Vessel must obtain valid COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Vessel produced original COD.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 April 2016
Resolved
Vessel must obtain current light list.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 7 July 2016
Resolution: Vessel outfitted with current CG Light List.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 28 April 2016
Resolved
Vessel must have a current MIS report.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 7 July 2016
Resolution: Vessel operator produce a copy of the 2015 MIS report.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 April 2016
Resolved
Vessel must have a complete first aid kit.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 7 July 2016
Resolution: Vessel outfitted with new first aid kit.
Fire Fighting › Fire Bucket › Quantity
Issued 28 April 2016
Resolved
Vessel must obtain 02 fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Vessel outfitted with 02 additional fire buckets.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 28 April 2016
Resolved
Port fuel line fitting at tank connection must be tighted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 7 July 2016
Resolution: Fuel connection tighted.