Records from 2016 to 2025. Most recent: inspection, 24 February 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)60.7 ft × 19.8 ft × 5.3 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBROOKLYN, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it0 - Dead Weight, Ton
61 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
24 February 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8083400
8 January 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8059908
4 March 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7871781
18 April 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7670719
27 February 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7643040
10 January 2023
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7618413
14 March 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7598277
16 March 2021
COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7157086
19 January 2021
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7127570
23 January 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6894430
8 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6683074
19 March 2019
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6637282
22 March 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6376498
18 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6127701
31 March 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6109464
1 June 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5893730
29 March 2016
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842563
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 24 February 2025
Resolved
No marine employer may engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer.
VSL operator had no proof that crewmember was enrolled in DAPI.
Action required: 705 - Other - as specified
Due 18 March 2025
Resolved 18 March 2025
Resolution: Rep. provided proof of DAPI enrollment, see documents.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 4 March 2024
Resolved
Provide DAPI / Drug & Alcohol Program proof 2023 report submission.
46 CFR 16.260
Note: discussed w/ rep. records required to be available at CG officials request - verification of recent pre-employment / random testing - could be satisfied upon confirmation of 2023 annual report submission to USCG by consortium
Action required: 10 - Deficiency Rectified
Resolved 4 March 2024
Resolution: O/O provided report of 2023 testing and confirmation of annual report submission to USCG from consortium management.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 March 2024
Resolved
PROVIDE REQUIRED ALCOHOL TEST EQUIPMENT ON BOARD.
46CFR185.212
NOTE: Vsl rep confirmed that their process for alcohol testing re: a marine casualty, etc. is to carry alcohol test strips on-board. They were not available on board at time of inspection. O/O ordered replacements in presence of MI's.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2024
Resolution: Accepted photos / receipt of swabs in-hand.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2024
Resolved
PROVIDE CURRENT NAVIGATIONAL CHARTS ON-BOARD.
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2024
Resolution: Accepted photos / receipts of current charts on-board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2021
Resolved
BATTERY CHARGERS MUST HAVE AN AMMETER CONNECTED IN THE CHARGING CIRCUIT. THE AFT BATTERY CHARGER DID NOT HAVE AN AMMETER IN THE CHARGING CIRCUIT.
46CFR183.350(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2021
Resolution: Photos of installed battery charger with ammeter sent to MI.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 March 2021
Resolved
AN EXPOSED HAZARD, SUCH AS ROTATING MACHINERY, MUST BE PROPERLY PROTECTED BY A COVER, GUARD, OR RAIL. THE PROPULSION SHAFTS AND ENGINE BELTS WERE NOT COVERED.
46CFR177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2021
Resolution: Photos of installed guards sent to MI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 January 2020
Resolved
Vessels on a Limited Coastwise route must have six approved red flare signals and six approved hand orange smoke distress signals. Vessel had 4 red and 3 orange on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 6 February 2020
Resolution: Received pictures of new flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2020
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Vessel representative stated that the vessel will place the adult and child size life jackets in different stowage containers and mark accordingly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 6 February 2020
Resolution: Received pictures of the new lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 January 2020
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The brackets securing the required life float lights are broken and need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 6 February 2020
Resolution: Received pictures of new brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 January 2020
Resolved
Each vessel that operates on the high seas must have on board an EPIRB installed to automatically float free and activate. Move EPIRB to a location that does not impede float free arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 6 February 2020
Resolution: Received pictures of new EPIRB position.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 18 April 2017
Resolved
Provide BI extinguisher for accomodation space
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2017
Resolved 19 April 2017
Resolution: Operator provided pictures of new extinguisher receipt and properly mounted in accomodation space.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 April 2017
Resolved
Properly mount pilot house extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2017
Resolved 19 April 2017
Resolution: Vessel provided pictures of properly mounted extinuisher.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 April 2017
Resolved
Secure lifejacket bins for top deck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2017
Resolution: Vessel operator provided pictures of life jacket storage bins secured with brackets.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 April 2017
Resolved
Post all required documentation in accommodation space.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Received email from operator showing placards had been mounted properly in the accomodation space.
Engineering › Bilge Water Management System › Interface Detector
Issued 18 April 2017
Resolved
Properly label all bilge alarms.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 April 2017
Resolution: Vessel provided pictures showing all bilge alarms properly labeled.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 April 2017
Resolved
Properly label breaker panels and what they serve.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 April 2017
Resolution: Operator provided pictures of properly labeled breaker panels.