Records from 1984 to 2025. Most recent: inspection, 24 February 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 65
24 February 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8083400
8 January 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8059908
4 March 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7871781
18 April 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7670719
27 February 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7643040
10 January 2023
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7618413
14 March 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7598277
16 March 2021
COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7157086
19 January 2021
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7127570
23 January 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6894430
8 May 2019
Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6683074
19 March 2019
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6637282
22 March 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6376498
18 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6127701
31 March 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6109464
1 June 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5893730
29 March 2016
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842563
30 May 2012
Type not recorded
No type recorded · Violation Case Coordination Center · Activity 4328765
8 May 2012
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4305364
7 September 2010
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3846078
28 April 2009
Deficiency Check · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3464699
26 February 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3424548
27 May 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3222060
16 October 2007
Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3081423
25 September 2007
Administrative Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3065749
24 May 2007
Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2940226
16 June 2006
In-Service Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2681716
31 January 2006
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2579893
21 November 2005
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2538581
13 April 2005
In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2342094
24 February 2005
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2298450
10 November 2004
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2238274
17 December 2003
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1968236
4 November 2003
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1941782
6 November 2002
COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1701635
15 November 2001
Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1401593
25 October 2000
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1413817
4 November 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1397288
2 November 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1416981
16 December 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1441440
16 December 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 784329
19 November 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 773238
4 November 1997
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1117616
6 November 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1107262
6 December 1995
Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 871892
1 December 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 870710
8 November 1994
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1180140
1 November 1994
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 862289
9 November 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 847772
2 November 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 838522
25 November 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829166
3 November 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1253733
11 December 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 946908
26 November 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938192
29 November 1990
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1231836
29 November 1989
Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1225825
29 November 1988
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1041151
22 November 1988
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1206097
3 December 1987
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1001771
19 November 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330596
4 December 1986
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1022388
19 November 1986
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330173
27 November 1985
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 996602
5 November 1985
Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1292629
4 December 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 972765
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 24 February 2025
Resolved
No marine employer may engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer.
VSL operator had no proof that crewmember was enrolled in DAPI.
Action required: 705 - Other - as specified
Due 18 March 2025
Resolved 18 March 2025
Resolution: Rep. provided proof of DAPI enrollment, see documents.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 4 March 2024
Resolved
Provide DAPI / Drug & Alcohol Program proof 2023 report submission.
46 CFR 16.260
Note: discussed w/ rep. records required to be available at CG officials request - verification of recent pre-employment / random testing - could be satisfied upon confirmation of 2023 annual report submission to USCG by consortium
Action required: 10 - Deficiency Rectified
Resolved 4 March 2024
Resolution: O/O provided report of 2023 testing and confirmation of annual report submission to USCG from consortium management.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 March 2024
Resolved
PROVIDE REQUIRED ALCOHOL TEST EQUIPMENT ON BOARD.
46CFR185.212
NOTE: Vsl rep confirmed that their process for alcohol testing re: a marine casualty, etc. is to carry alcohol test strips on-board. They were not available on board at time of inspection. O/O ordered replacements in presence of MI's.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2024
Resolution: Accepted photos / receipt of swabs in-hand.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2024
Resolved
PROVIDE CURRENT NAVIGATIONAL CHARTS ON-BOARD.
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 March 2024
Resolution: Accepted photos / receipts of current charts on-board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2021
Resolved
BATTERY CHARGERS MUST HAVE AN AMMETER CONNECTED IN THE CHARGING CIRCUIT. THE AFT BATTERY CHARGER DID NOT HAVE AN AMMETER IN THE CHARGING CIRCUIT.
46CFR183.350(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2021
Resolution: Photos of installed battery charger with ammeter sent to MI.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 March 2021
Resolved
AN EXPOSED HAZARD, SUCH AS ROTATING MACHINERY, MUST BE PROPERLY PROTECTED BY A COVER, GUARD, OR RAIL. THE PROPULSION SHAFTS AND ENGINE BELTS WERE NOT COVERED.
46CFR177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2021
Resolution: Photos of installed guards sent to MI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 January 2020
Resolved
Vessels on a Limited Coastwise route must have six approved red flare signals and six approved hand orange smoke distress signals. Vessel had 4 red and 3 orange on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 6 February 2020
Resolution: Received pictures of new flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2020
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Vessel representative stated that the vessel will place the adult and child size life jackets in different stowage containers and mark accordingly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 6 February 2020
Resolution: Received pictures of the new lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 January 2020
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The brackets securing the required life float lights are broken and need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 6 February 2020
Resolution: Received pictures of new brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 January 2020
Resolved
Each vessel that operates on the high seas must have on board an EPIRB installed to automatically float free and activate. Move EPIRB to a location that does not impede float free arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2020
Resolved 6 February 2020
Resolution: Received pictures of new EPIRB position.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 18 April 2017
Resolved
Provide BI extinguisher for accomodation space
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2017
Resolved 19 April 2017
Resolution: Operator provided pictures of new extinguisher receipt and properly mounted in accomodation space.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 April 2017
Resolved
Properly mount pilot house extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2017
Resolved 19 April 2017
Resolution: Vessel provided pictures of properly mounted extinuisher.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 April 2017
Resolved
Secure lifejacket bins for top deck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2017
Resolution: Vessel operator provided pictures of life jacket storage bins secured with brackets.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 April 2017
Resolved
Post all required documentation in accommodation space.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 8 May 2017
Resolution: Received email from operator showing placards had been mounted properly in the accomodation space.
Engineering › Bilge Water Management System › Interface Detector
Issued 18 April 2017
Resolved
Properly label all bilge alarms.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 April 2017
Resolution: Vessel provided pictures showing all bilge alarms properly labeled.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 April 2017
Resolved
Properly label breaker panels and what they serve.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 April 2017
Resolution: Operator provided pictures of properly labeled breaker panels.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 8 May 2012
Resolved
Fuel tank vent line missing flame screens
Action required: 705 - Other - as specified
Due 10 May 2012
Resolved 9 May 2012
Resolution: Recieved email picture verification of installation of flame screens
Engineering › Fuel Oil Service System › Filter
Issued 7 September 2010
Resolved
Vessel must provide flame shields on both MDE raycor filters and generator raycor filter.
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 21 September 2010
Resolution: Vessel purchased new flame shields and installed on all engines.
Lifesaving › Lifefloat › Platform
Issued 7 September 2010
Resolved
Repair or replace life floats metal platforms.
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 21 September 2010
Resolution: Metal platforms were repaired utilizing a pressure clamp.
Lifesaving › Lifefloat › Float Free
Issued 7 September 2010
Resolved
Install a line coiler for each set of life floats so that the painter will pay out smoothly.
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 21 September 2010
Resolution: Line coilers were purchased and installed.
Lifesaving › Lifefloat › Paddle
Issued 7 September 2010
Resolved
Vessel must provide two 4' paddles for one life float.
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 21 September 2010
Resolution: Vessel purchased and put in place two new paddles.
Lifesaving › Lifefloat › Serviceable
Issued 7 September 2010
Resolved
Vessel has three life floats, one of which is no longer serviceable. The other two have vinyl repair patches, these patches are not recommended by the manufacturer. Vessel must replace unserviceable life float and make proper repairs to the other two in accordance with the manufacturers recommendations.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 7 October 2010
Resolution: Vessel purchased and installed new 22 person life float. Updated approval numbers in MISLE.
Engineering › Bilge Water Management System › Valve
Issued 28 April 2009
Resolved
Install shut off valve for submersible pump in laz.
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 28 May 2009
Resolution: Received email with photo attached verifying def resolved.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 28 April 2009
Resolved
Properly ground fuel tanks.
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 28 May 2009
Resolution: Received email with photo attached verifying def resolved.
Lifesaving › Lifefloat › Lifeline
Issued 26 February 2009
Resolved
Replace lifefloat grab lines as indicated.
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 27 February 2009
Lifesaving › Lifefloat › Float Free
Issued 26 February 2009
Resolved
Provide wood spacers between lifefloats.
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 27 February 2009
Lifesaving › Lifefloat › Paddle
Issued 26 February 2009
Resolved
Label paddles with vessel's name.
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 27 February 2009
Operations/Management › Passenger Operations › Safety Orientation
Issued 26 February 2009
Resolved
Mark maximum number of passengers (23 persons) allowed on the upper deck at the entrance IAW 46 CRF 185.602(g).
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 27 February 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 September 2007
Resolved
V/weld all cracked welds on handrails.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 30 November 2007
Construction/Loadline › Hull › Hull Plating
Issued 25 September 2007
Resolved
Crop/renew wasted deck and watertight bulkhead between first and second watertight compartments. Provide plan and materials list to [name withheld] for review IWO this item.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 30 October 2007
Communications › Radio Communications › EPIRB
Issued 24 May 2007
Resolved
Replace expired EPIRB battery.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Lifesaving › Lifefloat › Markings
Issued 24 May 2007
Resolved
Properly label 02 lifefloats.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Lifesaving › Lifefloat › Serviceable
Issued 24 May 2007
Resolved
Make proper repairs to worn spots on 12 pax lifefloat.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Engineering › Bilge Water Management System › Strainer
Issued 24 May 2007
Resolved
Properly attach bilge strainer in forepeak.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 24 May 2007
Resolved
Properly label bilge high level alarms.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2007
Resolved
Properly attach light fixtures in 2nd void and lazarette.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 May 2007
Resolved
Make proper repairs to leaking starboard MSD overboard piping.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 21 June 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 May 2007
Resolved
Replace cracked flex hose IWO port MDE jacketwater cooling.
Action required: 705 - Other - as specified
Due 25 June 2007
Resolved 21 June 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2007
Resolved
Replace lagging on port MDE exhaust.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 21 June 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 24 May 2007
Resolved
Provide lifejacket donning placard for each type onboard vessel.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 24 May 2007
Resolved
Make proper repairs to/ replace port exhaust piping - piping has pinhole leaks on entire length.
Action required: 705 - Other - as specified
Due 24 June 2007
Resolved 21 June 2007
Engineering › Bilge Water Management System › Hose
Issued 24 May 2007
Resolved
Install check valve on electric bilge overboard on lazarette.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Engineering › Fuel Oil Service System › Hose
Issued 24 May 2007
Resolved
Install USCG approved hoses on generator with approved hoses on generator with approved connections/fittings.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 21 June 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 June 2006
Resolved
Remove old retro - reflective tape on ring life buoy and replace with new retro - reflective tape.
Due 30 June 2006
Resolved 20 November 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 16 June 2006
Resolved
Replace worn retro - reflective tape on life floats.
Due 30 June 2006
Resolved 20 November 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 April 2005
Resolved
RENEW 3 CHILD LIFEJACKETS IAW 46 CFR 180.71(B)
Action required: 705 - Other - as specified
Due 13 April 2005
Resolved 13 April 2005
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 13 April 2005
Resolved
ARRANGE LIFFLOATS IN A FLOAT FREE ARRANGEMENT AND ATTACH WEAK LINK AND TEATHER BOTH FLOATS TOGETHER IAW 46 CFR 180.200
Action required: 705 - Other - as specified
Due 13 April 2005
Resolved 13 April 2005
Communications › Visual Communication › Red Warning Signal
Issued 13 April 2005
Resolved
RENEW ALL FLARES IAW 46 CFR 180.68
Action required: 705 - Other - as specified
Due 13 April 2005
Resolved 13 April 2005
Communications › Radio Communications › EPIRB
Issued 13 April 2005
Resolved
PROVIDE PROOF OF EBRIB REGISTRATION IAW 46 CFR 180.64
Action required: 705 - Other - as specified
Due 13 April 2005
Resolved 13 April 2005
Engineering › Bilge Water Management System › Pump
Issued 13 April 2005
Resolved
STENCIL HIGH BILGE ALARM INDICATORS AT THE PILOT HOUSE IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 13 April 2005
Resolved 13 April 2005
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 13 April 2005
Resolved
PROVIDE PROOF OF BEING ENROLLED IN A DRUG CONSORTIUM IAW 46 CFR 16.230
Action required: 705 - Other - as specified
Due 13 April 2005
Resolved 13 April 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 December 2003
Resolved
Replace nylon lanyards with floating line on life floats and ring buoy, IAW 46CFR181.30. Corrected 18Dec03.
Due 18 December 2003
Resolved 18 December 2003
Communications › Internal Communications System
Issued 17 December 2003
Resolved
Provide two-way communication from operating station to lower deck (PA system), IAW 46CFR184.610.
Due 17 January 2004
Resolved 17 January 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 17 December 2003
Resolved
Provide working VHF radio prior to carrying passengers, IAW 46CFR184.502. Corrected prior to finishing inspection.
Due 17 December 2003
Resolved 17 December 2003
Engineering › Bilge Water Management System › Interface Detector
Issued 17 December 2003
Resolved
Install high bilge alarms in each watertight compartment, IAW 46CFR184.610, prior 7JUN04. LEGACY COMPONENT DESC: Interface Detector
Due 17 June 2004
Resolved 10 November 2004
Lifesaving › Buoyant Apparatus
Issued 6 November 2002
Resolved
ONE LIFEFLOAT NOT PROVIDED WITH PADDELS. LEGACY COMPONENT DESC: PADDELS
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2002
Resolved 7 November 2002
Communications › Radio Communications › EPIRB
Issued 6 November 2002
Resolved
HYDROSTATIC RELEASE EXPIRED FOR EBRIB.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2002
Resolved 7 November 2002
Lifesaving › Lifebuoys
Issued 6 November 2002
Resolved
CLIP NOT PROVIDED. LEGACY COMPONENT DESC: CORROSIVE RESISTENT CLIP
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2002
Resolved 7 November 2002
Accommodation/Occupational Safety
Issued 19 November 1997
Resolved
PROVIDE LOCKS FOR PORT AND STBD MSD SEAVALVES BEFORE NEXT SAIL.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Construction/Loadline
Issued 19 November 1997
Resolved
CLEAR DEBRIS FROM BILGE PICKUP AT FWK TANK COMPT.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Engineering
Issued 8 November 1994
Resolved
Renew fuel tank vent screens.
Condition: Unknown
Due 22 November 1994
Resolved 5 December 1994
Lifesaving
Issued 8 November 1994
Resolved
Renew missing rivits on 20 man buoyant apparatis.
Condition: Unknown
Due 22 November 1994
Resolved 5 December 1994
Lifesaving
Issued 8 November 1994
Resolved
Relocate buoyant apparatis floatlights for proper automatic deployment.
Condition: Unknown
Due 22 November 1994
Resolved 5 December 1994