MAURY USCG vessel records
← All vessels

HEATHER MARIE

Built
1975
Last inspected
22 October 2020
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 October 2020
…past their stated due date9
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD9419
Flag
UNITED STATES
Maury page id
psix-48578

Documentation record

Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 8 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each, 9 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

22 October 2020 Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7076986
8 September 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7056241
16 August 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6785159
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512546
24 August 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6250425
31 March 2017 Administrative Inspection · In-Service Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6120209
24 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6111286
30 August 2016 Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5982699

Deficiency record · 22

10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 No resolution recorded
Vsl is broadcasting invalid IMO # and AIS Ship Type, expired Radio Call Sign.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018 — due date passed with no resolution recorded
Lifesaving › Hand Flares › Expired
Issued 28 August 2017 No resolution recorded
Renew expired red flare
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 August 2017 No resolution recorded
Renew batteries in life float and life ring lights in accordance with manufacturer's instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Cable
Issued 28 August 2017 No resolution recorded
Remove permanently installed extension cords throughout vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 August 2017 No resolution recorded
Renew circuit breaker in engine room panel
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 28 August 2017 No resolution recorded
Remove or submit plans for installed shore tie receptacle in engine room prior to use.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Documentation › Certificates/Documents › FCC SSL
Issued 28 August 2017 No resolution recorded
Provide valid FCC Station License
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2017 — due date passed with no resolution recorded
Communications › Radio Communications › VHF Radiotelephone
Issued 28 August 2017 No resolution recorded
Provide VHF-DSC radio with integrated GPS and vessel's MMSI
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2017 — due date passed with no resolution recorded
Engineering › Pressure Vessel › Pressure Gauge
Issued 28 August 2017 No resolution recorded
Renew gauge on air receiver and conduct test of relief valve to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Suction Strainer
Issued 31 March 2017 Resolved
Fix fuel leak on port main engine strainer
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2017
Resolution: Replaced gaskets on strainer
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 31 March 2017 Resolved
Clean bilge of all dirty oil
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2017
Resolution: Removed oily waste from bilges and transferred to holding tank at marina
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 31 March 2017 Resolved
Make ground tackle (anchor) ready for use
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2017
Resolution: Rigged anchor with new chain and line, made ready for use
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 31 March 2017 Resolved
Service fire extinguisher for paint locker or remove paint locker from vessel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2017
Resolution: Crew removed paint locker and all contents from vessel
Stability › Watertight Integrity › General
Issued 24 March 2017 Resolved
The vessel may transit from Sector New Orleans’ area of responsibility to Sector Key West’s area of responsibility carrying bricks as cargo under the following conditions: 1. All Class 1 doors permitted within passenger, crew, and working spaces shall be closed at all time except when actually in use. 2. The vessel shall remain within 20 nautical miles of the shoreline. CITE:46 CFR 170.255;
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 31 March 2017
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 24 March 2017 Resolved
Within 07 days of arrival shall contact Sector Key West to arrange a re-zone Certificate of Inspection examination. CITE: 46 CFR 2.01-10
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 31 March 2017
Resolution: Conducted New to Zone Inspection at Sector Key West
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 January 2017 Resolved
Vessel did not have enough testing strips for entire crew as required. 46 CFR 16
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 24 January 2017
Resolution: Vessel rep acquired the proper amount of alcohol test strips, during the course of exam.
Operations/Management › Drills/Instruction › Fire
Issued 24 January 2017 Resolved
Vessel had no record of drills onboard and had a new crew during this inspection. 46 CFR 185.420 / 185.520
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 24 January 2017
Resolution: Had crew run fire and man over board drills during the course of the inspection. Logs were found, required lifesaving were recorded and verified this date. All items were noted satisfactory this date.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 24 January 2017 Resolved
Vessels magnetic compass was not reading correctly. Required a new deviation table and required compass adjustment to be completed. 33 CFR 164.35(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 27 January 2017
Resolution: Received, reviewed, and accepted new deviation chart as evidence of proper calibration.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 January 2017 Resolved
Vessels fixed co2 extinguisher bracket was damaged for the vessels flammable storage locker. Additionally, the locker needed to be organized and cleaned of wicking hazards. 46 CFR 181.20
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 27 January 2017
Resolution: M/I attended vessel and confirmed the bracket was replaced and flammable stowage locker was cleaned to the satisfaction of the attending inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 24 January 2017 Resolved
Vessel had several engine mounts missing and or loose, noted during this inspection. 46 CFR 181.20
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 27 January 2017
Resolution: M/I attended vessel and confirmed all engine's had proper mounting bolts installed and tight, found satisfactory to the attending inspector.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 24 January 2017 Resolved
Vessels forward mast light was found inoperative. 46 CFR 183.420
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 24 January 2017
Resolution: Vessel rep had crew replace and test mast head light in presence of the attending inspector. Noted satisfactory this date.
Communications › Radio Communications › Emergency Source of Power
Issued 24 January 2017 Resolved
Vessels emergency batteries for the vessels radio's were found not connected. 47 CFR 80
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 24 January 2017
Resolution: Vessel rep had crew make proper connections to the emergency batteries. Attending inspector had crew carry out tests to ensure the system was working as designed. All noted satisfactory during all tests of radio's with the back up batteries.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.