HEATHER MARIE

HEATHER MARIE is a 1975 industrial vessel. The Coast Guard has recorded 63 inspections since 1981, most recently in October 2020, along with 84 deficiencies — 9 with no resolution recorded — and 1 casualty investigation in 2007.

Records from 1981 to 2020. Most recent: inspection, 22 October 2020.

Built
1975
Last inspected
22 October 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9419
Flag
UNITED STATES
367311170
Maury page id
psix-48578

Inspections, by type

…with no type recorded14
…past their stated due date9
Years with a record 35 calendar years (1981–2020)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDJ7410MMSI 367311170 · active · compulsorily equipped · granted 14 September 2017, expires 14 September 2027
WDD9419MMSI 367311170 · cancelled · compulsorily equipped · granted 31 August 2007, cancelled 7 September 2017
WCX7928MMSI not assigned · expired · compulsorily equipped · granted 9 October 1997, cancelled 15 December 2007
WCV3160MMSI not assigned · cancelled · compulsorily equipped · granted 31 October 1995, cancelled 6 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
WAI2015MMSI not assigned · expired · compulsorily equipped · granted 1 December 1994, cancelled 26 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

22 October 2020 Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7076986
8 September 2020 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7056241
16 August 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6785159
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512546
24 August 2017 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6250425
31 March 2017 Administrative Inspection · In-Service Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6120209
24 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6111286
30 August 2016 Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5982699
18 August 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5215008
5 July 2012 COI Inspection · In-Service Inspection · Drydock Exam · Internal Structural Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4364819
22 December 2011 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4208720
25 October 2010 Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3874614
18 October 2010 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3872396
3 December 2009 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3639647
25 June 2008 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3247850
21 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3062694
5 September 2007 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3050131
3 April 2007 In-Service Inspection · Deficiency Check · Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2900473
28 March 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2897132
15 March 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2888887
8 March 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2888866
19 February 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2887698
6 June 2006 Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2659207
6 February 2006 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2580250
12 October 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2512702
27 June 2005 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2405526
1 June 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2512667
29 June 2004 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2114958
21 May 2004 Hull Examination · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2063670
17 June 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1819570
24 June 2002 Hull Examination · COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1635728
12 April 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1062111
16 March 2001 Examination of Repairs · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426555
3 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 160522
12 October 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 822974
11 May 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 818435
5 October 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1365399
8 December 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808432
17 November 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 806423
13 May 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388569
12 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114330
1 December 1997 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1406227
16 October 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452212
3 May 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467468
16 October 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422587
16 June 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412821
18 October 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358568
15 April 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438159
25 October 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396003
7 December 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1132280
20 November 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431172
10 December 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 945700
6 July 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939579
18 December 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212850
3 January 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216039
11 December 1986 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1024135
4 December 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330459
12 December 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989894
27 December 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977037
30 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975952
1 September 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966039
25 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973871
7 October 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967432

Deficiency record · 84

10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 No resolution recorded
Vsl is broadcasting invalid IMO # and AIS Ship Type, expired Radio Call Sign.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018 — due date passed with no resolution recorded
Lifesaving › Hand Flares › Expired
Issued 28 August 2017 No resolution recorded
Renew expired red flare
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 August 2017 No resolution recorded
Renew batteries in life float and life ring lights in accordance with manufacturer's instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Cable
Issued 28 August 2017 No resolution recorded
Remove permanently installed extension cords throughout vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 August 2017 No resolution recorded
Renew circuit breaker in engine room panel
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 28 August 2017 No resolution recorded
Remove or submit plans for installed shore tie receptacle in engine room prior to use.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Documentation › Certificates/Documents › FCC SSL
Issued 28 August 2017 No resolution recorded
Provide valid FCC Station License
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2017 — due date passed with no resolution recorded
Communications › Radio Communications › VHF Radiotelephone
Issued 28 August 2017 No resolution recorded
Provide VHF-DSC radio with integrated GPS and vessel's MMSI
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2017 — due date passed with no resolution recorded
Engineering › Pressure Vessel › Pressure Gauge
Issued 28 August 2017 No resolution recorded
Renew gauge on air receiver and conduct test of relief valve to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2017 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Suction Strainer
Issued 31 March 2017 Resolved
Fix fuel leak on port main engine strainer
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2017
Resolution: Replaced gaskets on strainer
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 31 March 2017 Resolved
Clean bilge of all dirty oil
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2017
Resolution: Removed oily waste from bilges and transferred to holding tank at marina
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 31 March 2017 Resolved
Make ground tackle (anchor) ready for use
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2017
Resolution: Rigged anchor with new chain and line, made ready for use
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 31 March 2017 Resolved
Service fire extinguisher for paint locker or remove paint locker from vessel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2017
Resolution: Crew removed paint locker and all contents from vessel
Stability › Watertight Integrity › General
Issued 24 March 2017 Resolved
The vessel may transit from Sector New Orleans’ area of responsibility to Sector Key West’s area of responsibility carrying bricks as cargo under the following conditions: 1. All Class 1 doors permitted within passenger, crew, and working spaces shall be closed at all time except when actually in use. 2. The vessel shall remain within 20 nautical miles of the shoreline. CITE:46 CFR 170.255;
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 31 March 2017
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 24 March 2017 Resolved
Within 07 days of arrival shall contact Sector Key West to arrange a re-zone Certificate of Inspection examination. CITE: 46 CFR 2.01-10
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 31 March 2017
Resolution: Conducted New to Zone Inspection at Sector Key West
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 January 2017 Resolved
Vessel did not have enough testing strips for entire crew as required. 46 CFR 16
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 24 January 2017
Resolution: Vessel rep acquired the proper amount of alcohol test strips, during the course of exam.
Operations/Management › Drills/Instruction › Fire
Issued 24 January 2017 Resolved
Vessel had no record of drills onboard and had a new crew during this inspection. 46 CFR 185.420 / 185.520
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 24 January 2017
Resolution: Had crew run fire and man over board drills during the course of the inspection. Logs were found, required lifesaving were recorded and verified this date. All items were noted satisfactory this date.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 24 January 2017 Resolved
Vessels magnetic compass was not reading correctly. Required a new deviation table and required compass adjustment to be completed. 33 CFR 164.35(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 27 January 2017
Resolution: Received, reviewed, and accepted new deviation chart as evidence of proper calibration.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 January 2017 Resolved
Vessels fixed co2 extinguisher bracket was damaged for the vessels flammable storage locker. Additionally, the locker needed to be organized and cleaned of wicking hazards. 46 CFR 181.20
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 27 January 2017
Resolution: M/I attended vessel and confirmed the bracket was replaced and flammable stowage locker was cleaned to the satisfaction of the attending inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 24 January 2017 Resolved
Vessel had several engine mounts missing and or loose, noted during this inspection. 46 CFR 181.20
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 27 January 2017
Resolution: M/I attended vessel and confirmed all engine's had proper mounting bolts installed and tight, found satisfactory to the attending inspector.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 24 January 2017 Resolved
Vessels forward mast light was found inoperative. 46 CFR 183.420
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 24 January 2017
Resolution: Vessel rep had crew replace and test mast head light in presence of the attending inspector. Noted satisfactory this date.
Communications › Radio Communications › Emergency Source of Power
Issued 24 January 2017 Resolved
Vessels emergency batteries for the vessels radio's were found not connected. 47 CFR 80
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2017
Resolved 24 January 2017
Resolution: Vessel rep had crew make proper connections to the emergency batteries. Attending inspector had crew carry out tests to ensure the system was working as designed. All noted satisfactory during all tests of radio's with the back up batteries.
Fire Fighting › Means of Escape › Stairways
Issued 18 August 2015 Resolved
STBD engine room escape hatch has holes near knife edge and gasket needs replacing. Fix holes, replace gasket, and adjust hatch so that it is watertight and closing properly.
Action required: 705 - Other - as specified
Due 1 September 2015
Resolved 25 August 2015
Resolution: Resolved to the satisfaction of the MI.
Lifesaving › Lifebuoys › Stowage
Issued 18 August 2015 Resolved
Aft deck lifebouy is hanging on hose reel with hose blocking the lifebouy. Put lifebouy on dedicated bracket.
Action required: 705 - Other - as specified
Due 1 September 2015
Resolved 18 August 2015
Resolution: New bracket was installed during the inspection.
Fire Fighting › Fire Main › Valves
Issued 3 December 2009 Resolved
Vessels fire monitor piping was fractured.
Condition: Unknown
Due 4 January 2010
Resolved 7 January 2010
Resolution: Fire main tested satisfactorily
Engineering › Fuel Oil Service System › Hose
Issued 3 December 2009 Resolved
Fuel oil hose from fuel header to fuel filter was not a SAE J 1942 hose. Replace with the correct fuel hose meeting SAE J1942 specifications.
Condition: Placed in Improper Service
Due 4 January 2010
Resolved 7 January 2010
Resolution: Fuel hose properly replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 December 2009 Resolved
Vessels oven is missing the required locking device to lock oven door closed.
Condition: Unknown
Due 4 January 2010
Resolved 7 January 2010
Resolution: Locking device properly installed
Lifesaving › Lifefloat › Lifeline
Issued 3 December 2009 Resolved
Current life float float lights lines are not of the correct lenght. Install new lines that are 18'.
Condition: Unknown
Due 4 January 2010
Resolved 7 January 2010
Resolution: Lanyards installed of proper length.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 September 2007 Resolved
Grey water from vessel's washing machine drains directly into bilge. Means is to be provided for the grey water to be routed directly overboard.
Action required: 705 - Other - as specified
Due 6 October 2007
Resolved 21 September 2007
Resolution: means adequately provided
Lifesaving › Lifefloat › Float-free Link
Issued 3 April 2007 Resolved
Lifefloats were not attached to the weak link.
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 6 April 2007
Resolution: Witnessed sat installation of the weak link.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 3 April 2007 Resolved
Provide required fire extinguishers per COI. No fire extinguishers on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2007
Resolved 6 April 2007
Resolution: Verified all portable fire extinguishers were onboard and serviced.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 3 April 2007 Resolved
Remove excess oily water mixture from bilges.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2007
Resolved 6 April 2007
Resolution: Reviewed third party receipt from vac company and verified the bilge had been cleaned.
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 3 April 2007 Resolved
Replace/repair lagging on port side generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2007
Resolved 6 April 2007
Resolution: New lagging was installed.
Fire Fighting › Means of Escape › Blocked
Issued 3 April 2007 Resolved
Emergency escape from crew berthing into mess deck area is blocked by carpeting.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2007
Resolved 6 April 2007
Resolution: Carpet was removed.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 3 April 2007 Resolved
The tonnage opening/watertight door leading from the crew seating area to the aft deck will need to be repaired/replaced at the next dry dock.
Action required: 705 - Other - as specified
Due 1 June 2008
Resolved 3 April 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 April 2007 Resolved
A lighting fixture at the engine room emergency escape was missing.
Due 30 April 2007
Resolved 6 September 2007
Resolution: fixture found to be in place
Fire Fighting › Fire Pumps › Arrangement
Issued 3 April 2007 Resolved
A section of piping on the fire monitor had a pin hole leak. (This system is separate from the main fire pump)
Due 13 April 2007
Resolved 6 September 2007
Resolution: System tested....no leak detected
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 3 April 2007 Resolved
One kapok life jacket was no longer serviceable and was destroyed.
Due 6 April 2007
Resolved 6 April 2007
Resolution: Extra life jackets were onboard.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 27 June 2005 Resolved
Provide min safe manning as required by vessel COI, for operations of more than 12 hours in a twenty-four hour period, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2005
Resolved 29 December 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 June 2005 Resolved
Provide/repair proper port side navigation light.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2005
Resolved 29 December 2005
Communications › Radio Communications › EPIRB
Issued 27 June 2005 Resolved
EPIRB battery expired, replace prior to operations.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 29 December 2005
Lifesaving › Lifefloat › Painter
Issued 27 June 2005 Resolved
Service lifefloats & weak link, mark floats.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2005
Resolved 29 December 2005
Documentation
Issued 16 March 2001 Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Documentation
Issued 16 March 2001 Resolved
VESSEL OPERATING 160 DAYS PASSED ITS COI ANNIVERSARY DATE WITHOUT A REINSPECTION WHICH IS REQUIRED WITHIN 90 DAYS OF THE COI ANNIVERSARY DATE.
Condition: Unknown
Due 16 April 2001
Resolved 18 June 2003
Construction/Loadline
Issued 16 March 2001 Resolved
REPLACE FOREPEAK HATCH COVER.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Construction/Loadline
Issued 16 March 2001 Resolved
PLACE NAME OF VESSEL AND HAILING PORT ON STERN.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Construction/Loadline
Issued 16 March 2001 Resolved
INSTALL NEW GASKET ON MAIN DECK ENGINEROOM ESCAPE HATCH.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Construction/Loadline
Issued 16 March 2001 Resolved
PLACE DRAFT MARKS ON THE VESSEL.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Documentation
Issued 16 March 2001 Resolved
PROVIDE CURRENT TRAINING LOGBOOK. PROVE DRILLS ARE BEING CONDUCTED.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Documentation
Issued 16 March 2001 Resolved
PROVIDE CURRENT LIFESAVING EQUIPMENT RECORD.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Lifesaving
Issued 16 March 2001 Resolved
RENEW ALL FLOAT LIGHT LINES.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Lifesaving
Issued 16 March 2001 Resolved
REPLACE PORTSIDE LIFERING LINE.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Navigation
Issued 16 March 2001 Resolved
PROVE CHARTS ARE BEING UPDATED.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Navigation
Issued 16 March 2001 Resolved
INSTALL FIXED PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Navigation
Issued 16 March 2001 Resolved
POST EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 16 April 2001
Resolved 23 March 2001
Fire Fighting
Issued 16 March 2001 Resolved
REPLACE ONE FIFTY FOOT SECTION OF FIRE HOSE.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Electrical
Issued 16 March 2001 Resolved
PROPERLY LABEL BOTH ELECTRICAL DISTRIBUTION PANELS IN ENGINEROOM.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Electrical
Issued 16 March 2001 Resolved
REMOVE ALL PAINT OVERSPRAY ON GENERATOR GUAGE PANEL.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Engineering
Issued 16 March 2001 Resolved
REPLACE FUEL HOSE ON PORT MAIN DIESEL ENGINE.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Engineering
Issued 16 March 2001 Resolved
REMOVE PAINT AND PROVE PROPER OPERATION OF RELIEF VALVE ON AIR RECEIVER.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Fire Fighting
Issued 16 March 2001 Resolved
MAKE PROPER REPAIRS TO PIPING ON MAIN FIRE PUMP.
Condition: Unknown
Due 16 April 2001
Resolved 12 April 2001
Electrical
Issued 5 October 1999 Resolved
Make proper electrical connections and remove all power strips and electrical extension cords, to include bridge console and washer and dryer.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Electrical
Issued 5 October 1999 Resolved
Replace broken circuit breaker switch on generator # 2 C/B.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Documentation
Issued 5 October 1999 Resolved
Provide proof of proper drug testing program including EAP program and MIS Form.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Accommodation/Occupational Safety
Issued 5 October 1999 Resolved
Install 100psi relief valve on hot water heater.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Engineering
Issued 5 October 1999 Resolved
Double nut or pin all eng throttle control linkages.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Unknown
Issued 5 October 1999 Resolved
Cap lug oil storage tank drain.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Lifesaving
Issued 5 October 1999 Resolved
Provide proper life float wink link assy. with correct tag.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Construction/Loadline
Issued 5 October 1999 Resolved
Provide proper hull draft markings.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Electrical
Issued 5 October 1999 Resolved
Install proper cover on engine alarm junction box in bridge console.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Construction/Loadline
Issued 5 October 1999 Resolved
Install audible and visual high bilge water alarm at operating station.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Navigation
Issued 5 October 1999 Resolved
Post emergency broadcast instructions at radio station.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Navigation
Issued 5 October 1999 Resolved
Post compass deviation card.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Electrical
Issued 5 October 1999 Resolved
Prove operation of port generator overspeed.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Construction/Loadline
Issued 5 October 1999 Resolved
Properly adjust and prove watertight integrity of all WTD'S.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Accommodation/Occupational Safety
Issued 5 October 1999 Resolved
PROPERLY SECURE WASHING MACHINE.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Electrical
Issued 17 November 1998 Resolved
PROVE PROPER OPERATION OF #2 GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Accommodation/Occupational Safety
Issued 17 November 1998 Resolved
PROPERLY MARK RANGE EMERGENCY DISCONNECT.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Fire Fighting
Issued 17 November 1998 Resolved
REPLACE WORN FIREHOSE.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Lifesaving
Issued 17 November 1998 Resolved
REMOVE EXCESS FLAMMABLE AND COMBUSTABLE LIQUIDS OR PROVIDE PROPER PAINT LOCKER.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Navigation
Issued 17 November 1998 Resolved
ADD STEERING LIMIT SWITCH TO PREVENT STEERING GEAR FROM CONTACTING RUDDER STOPS.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Lifesaving
Issued 17 November 1998 Resolved
DISCONTINUE USE OF CANVAS COVER OVER LIFERAFTS WHILE UNDERWAY.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Navigation
Issued 17 November 1998 Resolved
PROVIDE NOTICE TO MARINERS TO KEEP NAVIGATION PUBLICATIONS UP TO DATE.
Condition: Unknown
Due 17 November 1998
Resolved 17 November 1998
Construction/Loadline
Issued 25 October 1993 Resolved
MAKE PERMANENT REPAIRS BY CROPPING AND RENEWING A MINIMUM 24"X24" AREA OF SIDE SHELL LOCTED BEHIND WATER HEATER IWO AFT PORT CORNER OF ENGINE ROOM ADJACENT TO AFT WT BHD AT NEXT DRYDOCK BUT NO LATER THAN 24MAY94.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993

Casualty record · 1

19 February 2007Routine · role: Acknowledged Pollution Source · activity 2887698
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.