Inspection record

Last inspected 8 January 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF 4177
Flag
UNITED STATES
Maury page id
psix-48585

Documentation record

Registered dimensions (L × B × D)61.7 ft × 21.7 ft × 7.1 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTIBURON, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 24 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

8 January 2026 Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8292096
1 May 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8127128
17 April 2025 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8100865
25 November 2024 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8069447
16 April 2024 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7896109
20 February 2024 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7865555
4 January 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7845712
25 April 2023 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7675212
16 December 2022 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7610215
23 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7484369
10 January 2022 Hull Examination · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7376102
28 July 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7271820
18 May 2021 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7199310
14 September 2020 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7057801
15 April 2020 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939619
27 February 2020 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6914894
28 May 2019 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6706877
23 May 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6691894
31 May 2018 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6429727
21 March 2018 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6375647
17 July 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6212075
13 January 2017 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6070528
11 April 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5859753
28 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5841916

Deficiency record · 48

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI observed port and starboard throttle commands on new propulsion control system correspond to the incorrect engines. Vessel is restricted from departing Tiburon Ferry Terminal until satisfactory repairs are witnessed by a Marine Inspector. 46 CFR 182.200(a)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2025
Resolved 2 May 2025
Resolution: MI attended vessel, verified repairs and witnessed satisfactory sea trials.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 April 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel IAW the terms of its COI giving consideration to provisions for a seaworthy hull. In the forepeak, at the transverse frame in the point of the bow, there were two fractures in the weld. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 21 April 2025
Resolution: Operator provided photos of weld repair made to cracks in forepeak frame.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2025 Resolved
Machinery, equipment, materials, and arrangements ...inspected IAW standards acceptable to the cognizant OCMI as good marine practice. There was small a fuel leak in the center compartment. 46 CFR 176.800(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 2 May 2025
Resolution: MI attended vessel and verified satisfactory repair.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency condition. Several lights in the Engine room were extinguished. 46 CFR 183.200 (a) 46 CFR 183.200 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 2 May 2025
Resolution: MI attended vessel and verified all engine room lights functional.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 April 2025 Resolved
A penetration in a watertight bulkhead must be as high as practicable, and made watertight. Several bulkhead cable penetration throughout the vessel were no watertight. 46 CFR 179.320(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 2 May 2025
Resolution: MI attended vessel and verified satisfactory repairs to 03 penetrations in engine room aft bulkhead and 03 penetrations in center void forward bulkhead.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2025 Resolved
Each nozzle must...be capable of being changed between a solid stream and a spray pattern. Nozzle was seized and had to be removed for the hose to spray water. 46 CFR 181.320 (d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 2 May 2025
Resolution: MI attended vessel and verified new nozzle installed on port side fire station functioning properly.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 April 2025 Resolved
A vessel must carry six hand red flares and six orange smoke flares or 12 red hand flares. Four red flares were expired. 46 CFR 169.553 (c)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 2 May 2025
Resolution: MI attended vessel and verified flares onboard are unexpired and appropriate in quantity.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2025 Resolved
Each life jacket must be marked with Type I retroreflective material. Retroreflective tape on one life jacket was degraded. 46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 2 May 2025
Resolution: MI attended vessel and verified life jacket replaced with new.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 April 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication. U.S. Coast Pilot was not present on board. 46 CFR 184.420(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 1 May 2025
Resolution: MI attended vessel and verified Coast Pilot onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 April 2025 Resolved
Each EAP education program must include … hot-line telephone number for crewmember assistance. EAP hotline was not posted. 46 CFR 16.401(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 2 May 2025
Resolution: MI attended vessel and verified EAP hotline number posted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 April 2024 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: (1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.” (2) Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Marine Inspector (MI) observed, CO2 protected engine room, and void containing CO2 bottles were not marked with appropriate signs. 46 CFR 185.612 (g)
Condition: Improper Installation
Due 30 April 2024
Resolved 8 May 2024
Resolution: Operator provided photographs of new signs to CO2 protected space and CO2 storage space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 April 2024 Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q. MI observed deteriorated and broken grab line on approved life buoy on aft main deck. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 30 April 2024
Resolution: Operator replaced ring buoy in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2024 Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Marine Inspector (MI) observed deteriorated flexible hosing for generator exhaust in lazarette on starboard side. 46 CFR 182.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 30 April 2024
Resolution: Operator provided photos of new SAE J2006R2 piping installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 April 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. MI observed fire extinguisher in galley pantry space was not in an approved bracket. 46 CFR 181.500(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 6 June 2024
Resolution: Operator provided photograph of new bracket installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 April 2024 Resolved
S. The fire pump shall be selfpriming and of such size as to discharge an effective stream from a hose connected to the highest outlet. During a test of the fire pump, MI observed poor discharge volume from the main deck fire hoses. 46 CFR 181.15-5 (Old T).
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2024
Resolved 30 April 2024
Resolution: Operator provided video demonstrating capacity of fire pump, which showed the hose filling a 5 gallon bucket in approximately 50 seconds.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2024 Resolved
Ground detection must be provided that: (1) For an alternating current system, meets § 111.05-27 in subchapter J of this chapter; and (2) For a direct current system, meets § 111.05-29 in subchapter J of this chapter. MI observed dual voltage generator did not have ground detection installed. Install required ground detection prior to next credit drydock. 46 CFR 183.324(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2024
Resolved 14 April 2025
Resolution: MI attended vessel at conclusion of repower and verified installation of approved ground fault detection.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 16 April 2024 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter. MI observed that installed MF-DSC radio was not receiving vessel position or vessel MMSI. Limited to 20nm. 46 CFR 184.502 47 CFR 80.903
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 9 July 2024
Resolution: Operator provided photographs of installed radio with MMSI and Position displayed
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 April 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician. MI observed MF-DSC radio on the vessel was not broadcasting all required information. 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 9 July 2024
Resolution: Verified license accurate for equipment on vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 February 2024 Resolved
A periodic examination made in accordance with the requirements of this subpart shall include the under-water hull and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Marine Inspector observed widespread pitting on integral fuel tank hull plating and longitudinal frame members below waterline spanning from port chine to starboard chine. Submit repair proposal to satisfaction of Marine Inspector. 46 CFR 176.15-5 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 March 2024
Resolution: OCMI approved plan to open tank at next drydock and make available for CG inspection. Special Note added to relect inspection plan.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 April 2023 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Replace missing machinery guard on stbd engine. 46 CFR 177.35-15(a) "OLD T"
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2023
Resolved 5 September 2023
Resolution: Guard properly installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 April 2023 Resolved
Where segregation can be obtained by means of a watertight and/or vapor tight engine box, this will be accepted as a substitute for the required bulkheads. Gasket on engine room hatch is missing, replace and repair. 46 CFR 182.35-1(b) "OLD T"
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2023
Resolved 5 September 2023
Resolution: Gasket properly renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2022 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Aluminum bilge piping in center void servicing forepeak bilge suction is showing signs of wastage. Replacement in kind to satisfaction of marine inspector. 46 CFR 182.25-1 OLD T.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2022
Resolved 25 July 2022
Resolution: Received satisfactory photos of replaced bilge piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2022 Resolved
A visual and audible alarm must be provided at operating station to indicate a high water level. High water level alarms for lazarette, center, and forepeak inoperable. Repaired in presence of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 June 2022
Resolution: Deficiency rectified in the presence of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 June 2022 Resolved
Each lifefloat must be individually attached to the painter. Aft lifefloats not connected to weak link. Corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 June 2022
Resolution: Deficiency corrected in the presence of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel currently carries 120 adult life jackets. Until vessel obtains 3 additional adult life jackets, total persons allowed on board will be decreased to 120 (3 crew and 117 passengers).
Action required: 705 - Other - as specified
Resolved 25 June 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 18 May 2021 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel carries two types of life jackets, but has donning instructions for only one type. Vessel must have donning instructions for all types.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 25 June 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 May 2021 Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: (4)Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. One of the six life float lights did not work.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2021
Resolution: Battery was replaced and light now works.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 April 2020 Resolved
Except when operating on lakes, bays, and sounds, or rivers routes in calm weather, all hatches and openings in the hull must be kept tightly closed except when being used. The vessel's hatch for the #2 port void is unable to be closed and does not meet the watertight requirements for the vessel's route. Repair or replace hatch so that it can be closed and meets the required watertight conditions.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2020
Resolution: Operator submitted photos via email to show the proper replacement and installation of the hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 April 2020 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in the following space: a machinery space bilge. The vessel's float switch in the machinery space was unable to produce a visible and audible alarm upon actuation. Repair or replace the float switch so that an audible and visual alarm sounds when there is a high water level.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2020
Resolution: Operator corrected faulty wiring and submitted a video via email showing that the float switch actuates a visual and audible alarm from the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 May 2019 Resolved
The float-free link required by §180.130(a)(1) must be of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. The float-free link on board is not strong enough for the life float installation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2019
Resolved 30 May 2019
Resolution: Vessel operator Sam sent photo of appropriate strength float-free link (21+).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2019 Resolved
Each ring life buoy with a floating waterlight must have a lanyard securing the waterlight around the body of the ring life buoy. Lanyard was not secured around the body of the ring life buoy.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 May 2019
Resolved 28 May 2019
Resolution: Deckhand properly secured it during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2019 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's starboard navigation light was burnt out.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 May 2019
Resolved 28 May 2019
Resolution: Captain replaced light during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2019 Resolved
The individual bilge suction lines shall be led to a central control point or manifold. Each line shall be provided with a stop valve at the control point or manifold and in addition shall be provided with a check valve at some accessible point in the bilge line. The check valve provided was seized and prevented discharge of water from the forepeak bilge. 46 CFR 182.25-5(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 May 2019
Resolved 28 May 2019
Resolution: Vessel reps serviced check valve during inspection, enabling the flow of water through it.
Construction/Loadline › Structures › Ventilators
Issued 31 May 2018 Resolved
03 vents on the forward portion of the superstructure, flush with the main deck, must be permanently fixed to prevent water flooding into the space.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 18 June 2018
Resolution: replaced fasteners and gaskets for all vents on the bow.
Construction/Loadline › Structures › Door
Issued 31 May 2018 Resolved
Pilot house doors/ top side aft door/main deck doors/ needs new gaskets, repair holes, replace door handles and fix trim
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 18 June 2018
Resolution: All doors received required maintenance ensuring they are weather tight.
Lifesaving › Lifefloat › Serviceable
Issued 31 May 2018 Resolved
04 life floats need temp repair, replacement plan required for 04 life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 23 August 2018
Resolution: Life rafts have been repaired and invoice from Sal's inflatables has been supplied to prove the repairs.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 31 May 2018 Resolved
01 Fire extinguisher not mounted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 7 June 2018
Resolution: Bracket mounted and fire extinguisher secured.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 May 2018 Resolved
Missing Emergency broadcast placard
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 20 June 2018
Resolution: Emergency broadcast placard replaced
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 31 May 2018 Resolved
Damaged exhaust hose in steering gear space
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 7 June 2018
Resolution: Replaced with new exhaust hose.
Electrical › Electric Supply System (service) › Cable
Issued 31 May 2018 Resolved
Remove excessive 110V wires in engine room
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 23 August 2018
Resolution: Excessive 110V wires have been removed as requested.
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 31 May 2018 Resolved
Protective cover for starter solenoid wires
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 23 August 2018
Resolution: Protective cover for starter solenoid has been installed.
Electrical › Electric Supply System (service) › Cable
Issued 31 May 2018 Resolved
Capstan wire in forepeak needs chaffing gear.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 28 June 2018
Resolution: Chaffing gear installed to prevent further damage.
Lifesaving › Lifebuoys › Serviceable
Issued 31 May 2018 Resolved
Life ring needs replaced lettering, more accessible stowage location and bracket mounted for strobe light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 7 June 2018
Resolution: Life ring was made more accessible and lettering replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 May 2018 Resolved
Shaft guards need to be installed on both port and starboard engines.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 23 August 2018
Resolution: Shaft guards have been installed for both the port and starboard engines.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 July 2017 Resolved
Exposed Wires were located on aft bulkhead of Engineroom. 46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 18 August 2017
Resolution: Wires removed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 July 2017 Resolved
Remote Fuel Shutoff was not labeled. 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 18 August 2017
Resolution: Fuel Shutoff Valves Labeled.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 April 2016 Resolved
Make proper repairs to exhaust piping and prove to attending marine inspector the pipe is free of leakage.
Condition: Improper/Lack of Maintenance
Due 23 April 2016
Resolved 25 April 2016
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 11 April 2016 Resolved
Make proper repairs to MSD tank to the satisfaction of the attending marine inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 22 August 2016
Resolution: Made proper repairds to MSD tank.