← All vessels
TAMALPAIS
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named TAMALPAIS
TAMALPAIS is a 1976 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1985, most recently in January 2026, along with 105 deficiencies, 4 operational controls and 1 casualty investigation in 2004.
Records from 1985 to 2026. Most recent: inspection, 8 January 2026.
- Built
- 1976
- Last inspected
- 8 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 105 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2004
Identity
569985
WDF 4177
48585
Flag
UNITED STATES
367448870
Maury page id
psix-48585
Inspections, by type
…with no type recorded12
Years with a record
38 calendar years (1985–2026)
The 91 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.7 ft × 21.7 ft × 7.1 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTIBURON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDF4177MMSI 367448870 · active · compulsorily equipped · granted 19 February 2020, expires 23 April 2030
WCZ3851MMSI not assigned · expired · compulsorily equipped · granted 8 July 1999, cancelled 12 September 2009 · licensed under a name not among this hull’s recorded names (not shown)
WAL5085MMSI 366056000 · expired · compulsorily equipped · granted 10 March 1995, cancelled 16 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 91
8 January 2026
Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8292096
1 May 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8127128
17 April 2025
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8100865
25 November 2024
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8069447
16 April 2024
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7896109
20 February 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7865555
4 January 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7845712
25 April 2023
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7675212
16 December 2022
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7610215
23 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7484369
10 January 2022
Hull Examination · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7376102
28 July 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7271820
18 May 2021
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7199310
14 September 2020
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7057801
15 April 2020
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939619
27 February 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6914894
28 May 2019
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6706877
23 May 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6691894
31 May 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6429727
21 March 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6375647
17 July 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6212075
13 January 2017
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6070528
11 April 2016
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5859753
28 March 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5841916
6 November 2015
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5759169
18 March 2014
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4829738
24 July 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4390654
23 July 2012
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4392648
14 August 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3298569
27 June 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3249579
24 June 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3234735
24 June 2008
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3246989
27 March 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3166097
7 May 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2922254
2 April 2007
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2900116
4 May 2006
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639382
24 March 2006
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2609076
1 September 2005
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2481060
29 April 2005
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2323074
16 March 2005
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2310863
22 October 2004
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2226189
16 May 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2078902
15 April 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2045563
25 March 2004
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2038862
8 October 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1924266
19 August 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1861784
6 May 2002
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1613405
5 March 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1490208
18 June 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1465041
2 May 2000
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1424905
10 April 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1437711
3 September 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1369334
31 August 1999
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 781924
30 June 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1082863
30 June 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1097379
18 May 1999
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 797756
11 December 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400890
17 April 1998
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383845
27 January 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 783030
8 May 1997
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1385993
14 April 1997
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1093644
5 March 1997
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1101223
5 June 1996
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 51133
5 June 1996
Examination of Repairs · Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1470118
22 May 1996
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1083783
17 April 1996
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1466968
8 June 1995
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 876892
18 May 1995
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 18948
18 May 1995
Examination of Repairs
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1184717
27 April 1995
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1183561
28 April 1994
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1451934
15 March 1994
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1398024
20 April 1993
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 825606
8 April 1993
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1148785
6 October 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 653164
1 October 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 100561
17 September 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 147568
26 June 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 144261
13 May 1992
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 946897
10 May 1991
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 909613
4 May 1990
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1216152
9 February 1990
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 920379
17 January 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1229600
27 April 1989
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1351377
21 April 1988
COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1342064
10 September 1987
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1310318
17 April 1987
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1002049
14 September 1986
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1311336
25 April 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1306484
24 March 1986
Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 998669
3 May 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 982050
Deficiency record · 105
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI observed port and starboard throttle commands on new propulsion control system correspond to the incorrect engines. Vessel is restricted from departing Tiburon Ferry Terminal until satisfactory repairs are witnessed by a Marine Inspector. 46 CFR 182.200(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 April 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel IAW the terms of its COI giving consideration to provisions for a seaworthy hull. In the forepeak, at the transverse frame in the point of the bow, there were two fractures in the weld.
46 CFR 177.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2025
Resolved
Machinery, equipment, materials, and arrangements ...inspected IAW standards acceptable to the cognizant OCMI as good marine practice. There was small a fuel leak in the center compartment.
46 CFR 176.800(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency condition. Several lights in the Engine room were extinguished.
46 CFR 183.200 (a)
46 CFR 183.200 (a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 April 2025
Resolved
A penetration in a watertight bulkhead must be as high as practicable, and made watertight. Several bulkhead cable penetration throughout the vessel were no watertight.
46 CFR 179.320(c)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2025
Resolved
Each nozzle must...be capable of being changed between a solid stream and a spray pattern. Nozzle was seized and had to be removed for the hose to spray water.
46 CFR 181.320 (d)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 April 2025
Resolved
A vessel must carry six hand red flares and six orange smoke flares or 12 red hand flares. Four red flares were expired.
46 CFR 169.553 (c)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2025
Resolved
Each life jacket must be marked with Type I retroreflective material. Retroreflective tape on one life jacket was degraded.
46 CFR 185.604(b)
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 April 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication. U.S. Coast Pilot was not present on board.
46 CFR 184.420(a)(2)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 April 2025
Resolved
Each EAP education program must include … hot-line telephone number for crewmember assistance. EAP hotline was not posted.
46 CFR 16.401(a)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 April 2024
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: (1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.” (2) Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Marine Inspector (MI) observed, CO2 protected engine room, and void containing CO2 bottles were not marked with appropriate signs. 46 CFR 185.612 (g)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 April 2024
Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q. MI observed deteriorated and broken grab line on approved life buoy on aft main deck. 46 CFR 180.70(b)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2024
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Marine Inspector (MI) observed deteriorated flexible hosing for generator exhaust in lazarette on starboard side. 46 CFR 182.430
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 April 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. MI observed fire extinguisher in galley pantry space was not in an approved bracket. 46 CFR 181.500(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 April 2024
Resolved
S. The fire pump shall be selfpriming and of such size as to discharge an effective stream from a hose connected to the highest outlet. During a test of the fire pump, MI observed poor discharge volume from the main deck fire hoses. 46 CFR 181.15-5 (Old T).
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2024
Resolved
Ground detection must be provided that: (1) For an alternating current system, meets § 111.05-27 in subchapter J of this chapter; and (2) For a direct current system, meets § 111.05-29 in subchapter J of this chapter. MI observed dual voltage generator did not have ground detection installed. Install required ground detection prior to next credit drydock. 46 CFR 183.324(c)
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 16 April 2024
Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter. MI observed that installed MF-DSC radio was not receiving vessel position or vessel MMSI. Limited to 20nm. 46 CFR 184.502 47 CFR 80.903
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 April 2024
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician. MI observed MF-DSC radio on the vessel was not broadcasting all required information. 47 CFR 80.903
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 February 2024
Resolved
A periodic examination made in accordance with the requirements of this subpart shall include the under-water hull and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Marine Inspector observed widespread pitting on integral fuel tank hull plating and longitudinal frame members below waterline spanning from port chine to starboard chine. Submit repair proposal to satisfaction of Marine Inspector.
46 CFR 176.15-5
(OLD T)
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 April 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears,
machinery, etc. Replace missing machinery guard on stbd engine.
46 CFR 177.35-15(a) "OLD T"
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 April 2023
Resolved
Where segregation can be obtained by means of a watertight and/or vapor tight engine box, this will be accepted as a substitute for the required bulkheads. Gasket on engine room hatch is missing, replace and repair.
46 CFR 182.35-1(b) "OLD T"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2022
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Aluminum bilge piping in center void servicing forepeak bilge suction is showing signs of wastage. Replacement in kind to satisfaction of marine inspector. 46 CFR 182.25-1 OLD T.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2022
Resolved
A visual and audible alarm must be provided at operating station to indicate a high water level. High water level alarms for lazarette, center, and forepeak inoperable. Repaired in presence of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 June 2022
Resolved
Each lifefloat must be individually attached to the painter. Aft lifefloats not connected to weak link. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel currently carries 120 adult life jackets. Until vessel obtains 3 additional adult life jackets, total persons allowed on board will be decreased to 120 (3 crew and 117 passengers).
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 18 May 2021
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel carries two types of life jackets, but has donning instructions for only one type. Vessel must have donning instructions for all types.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 May 2021
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: (4)Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. One of the six life float lights did not work.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 April 2020
Resolved
Except when operating on lakes, bays, and sounds, or rivers routes in calm weather, all hatches and openings in the hull must be kept tightly closed except when being used. The vessel's hatch for the #2 port void is unable to be closed and does not meet the watertight requirements for the vessel's route. Repair or replace hatch so that it can be closed and meets the required watertight conditions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 April 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in the following space: a machinery space bilge. The vessel's float switch in the machinery space was unable to produce a visible and audible alarm upon actuation. Repair or replace the float switch so that an audible and visual alarm sounds when there is a high water level.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 May 2019
Resolved
The float-free link required by §180.130(a)(1) must be of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. The float-free link on board is not strong enough for the life float installation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2019
Resolved
Each ring life buoy with a floating waterlight must have a lanyard securing the waterlight around the body of the ring life buoy. Lanyard was not secured around the body of the ring life buoy.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2019
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's starboard navigation light was burnt out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2019
Resolved
The individual bilge suction lines shall be led to a central control point or manifold. Each line shall be provided with a stop valve at the control point or manifold and in addition shall be provided with a check valve at some accessible point in the bilge line. The check valve provided was seized and prevented discharge of water from the forepeak bilge.
46 CFR 182.25-5(c)
Construction/Loadline › Structures › Ventilators
Issued 31 May 2018
Resolved
03 vents on the forward portion of the superstructure, flush with the main deck, must be permanently fixed to prevent water flooding into the space.
Construction/Loadline › Structures › Door
Issued 31 May 2018
Resolved
Pilot house doors/ top side aft door/main deck doors/ needs new gaskets, repair holes, replace door handles and fix trim
Lifesaving › Lifefloat › Serviceable
Issued 31 May 2018
Resolved
04 life floats need temp repair, replacement plan required for 04 life floats.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 31 May 2018
Resolved
01 Fire extinguisher not mounted.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 May 2018
Resolved
Missing Emergency broadcast placard
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 31 May 2018
Resolved
Damaged exhaust hose in steering gear space
Electrical › Electric Supply System (service) › Cable
Issued 31 May 2018
Resolved
Remove excessive 110V wires in engine room
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 31 May 2018
Resolved
Protective cover for starter solenoid wires
Electrical › Electric Supply System (service) › Cable
Issued 31 May 2018
Resolved
Capstan wire in forepeak needs chaffing gear.
Lifesaving › Lifebuoys › Serviceable
Issued 31 May 2018
Resolved
Life ring needs replaced lettering, more accessible stowage location and bracket mounted for strobe light.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 May 2018
Resolved
Shaft guards need to be installed on both port and starboard engines.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 July 2017
Resolved
Exposed Wires were located on aft bulkhead of Engineroom. 46 CFR 183.200
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 July 2017
Resolved
Remote Fuel Shutoff was not labeled. 46 CFR 185.608
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 April 2016
Resolved
Make proper repairs to exhaust piping and prove to attending marine inspector the pipe is free of leakage.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 11 April 2016
Resolved
Make proper repairs to MSD tank to the satisfaction of the attending marine inspector
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 24 July 2012
Resolved
Provide latch for port side Engine Room ventilation duct hatch.
Documentation › Logs/Records › Drug Test Records
Issued 23 July 2012
Resolved
Documentation of pre-employment testing not kept for entire employment period as required by 46 CFR 16.260.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008
Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008
Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008
Resolved
Alcohol testing devices not onboard as required by 46 CFR part 4.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 24 June 2008
Resolved
Company did not have records of pre-employments as required by 46 CFR 16.210.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 June 2008
Resolved
Re-new 09 adult lifejackets due to being unserviceable.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 24 June 2008
Resolved
114 lifejacket lights expired.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 24 June 2008
Resolved
Re-new Hydrostatic release for Epirb.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 June 2008
Resolved
Re-new expired items in First Aid Kit.
Lifesaving › Lifefloat › Paddle
Issued 24 June 2008
Resolved
Secure paddles in Lifefloats.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 June 2008
Resolved
01 Lifefloat light ooc.
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 June 2008
Resolved
Provide new Coast Pilot.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 June 2008
Resolved
Provide proper operation of Bilge Alarms in the engine room and the Lazarette.
Engineering › Bilge Water Management System › Not Operational
Issued 24 June 2008
Resolved
Provide proper operation of all 05 Bilge Suctions.
Engineering › Steering Gear System › Hydraulic Hose
Issued 24 June 2008
Resolved
Repair leaking hydraulic hose on steering system in the lazarette.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 24 June 2008
Resolved
Obtain CPR Certification.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 24 June 2008
Resolved
Obtain First Aid Certification.
Fire Fighting › Nozzles › Condition
Issued 24 June 2008
Resolved
Provide proper operation of both fire station nozzles.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 June 2008
Resolved
Secure exposed wiring under bridge console.
Documentation › Logs/Records › Logbook (official)
Issued 24 June 2008
Resolved
Provide Training Log Book.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 June 2008
Resolved
Conduct U/W Operational Tests and Conduct Man Overboard and Fire Drills.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 May 2007
Resolved
Provide updated copy of light list.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 May 2007
Resolved
Separate child PFD's from adult PFD's on 2nd deck in aft storage space.
Engineering › Bilge Water Management System › Piping
Issued 4 May 2006
Resolved
Makes repairs and prove proper operation of Forepeak bilge pump suction system.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 4 May 2006
Resolved
Provide current Coast Pilot [name withheld] and charts.
Communications › Radio Communications › EPIRB
Issued 4 May 2006
Resolved
Provide proof of current EPIRB registration.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 4 May 2006
Resolved
Provide 2 Adult PFD's. Adult passenger count limited to 118 while in operation.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 May 2006
Resolved
Provide missing placards (2) for Lifesaving PFD storage area in way of main deck dance area with proper number of Lifejackets being stowed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 May 2006
Resolved
Renew float light battery on ring buoy.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 May 2006
Resolved
Update First Aid Kit.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 24 March 2006
Resolved
Replace port shaft cutlass bearing.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 24 March 2006
Resolved
Provide report on condition of stbd cutlass bearing.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 24 March 2006
Resolved
Replace both port and stbd propeller lock nuts.
Construction/Loadline › Structures › End Bulkhead
Issued 24 March 2006
Resolved
Repair holes in main house end bulkhead aft.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 March 2006
Resolved
Make generator exhaust bulkhead penetration watertight and vapor tight.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 24 March 2006
Resolved
Repair hole and crack in frame, aft outboard frame connected to stbd shaft support in lazarette.
Engineering › Sea-water System (primary cooling) › Valve
Issued 24 March 2006
Resolved
Remove both MDE sea chest valves for inspection and prove proper operation.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 16 March 2005
Resolved
Make permanent repairs to sewage tank.
Navigation
Issued 15 April 2004
Resolved
Provide current navigation publications (CG Light List, Coast Pilot, Tide and Current Tables) for area of operation.
Navigation
Issued 15 April 2004
Resolved
Provide up to date navigation charts for area of operation.
Documentation › Markings/Placards
Issued 15 April 2004
Resolved
Provide emergency broadcast placard and post at operation station.
Lifesaving
Issued 15 April 2004
Resolved
Provide placard for child size lifejacket stowage location incidating "12" child lifejackets.
Lifesaving
Issued 15 April 2004
Resolved
Properly mount and provide proof of registration of EPIRB.
Lifesaving › Buoyant Apparatus
Issued 15 April 2004
Resolved
Properly attach all lifefloats with weak link connection.
Fire Fighting › Nozzles
Issued 15 April 2004
Resolved
Provide nozzle for stbd side fire hose.
Fire Fighting › Fire Hoses › Length
Issued 15 April 2004
Resolved
Provide 50' fire hose in order to rach all vsl compartment spaces.
Fire Fighting › Fire Pumps › Impeller
Issued 15 April 2004
Resolved
Prove proper operation of fire pump.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 15 April 2004
Resolved
Provide machinery guards for alternator belts on stbd main diesel engine.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 August 2003
Resolved
Correct marking of life jacket storage.
Engineering › Bilge Water Management System
Issued 19 August 2003
Resolved
Make permanent repairs at bilge system manifold, for fore peak and forward holds. Show proof of proper bilge operation.
Electrical › Electric Supply System (service)
Issued 19 August 2003
Resolved
Replace starter cables on starboard MDE with approved marine grade type. LEGACY COMPONENT DESC: Battery Conductor
Electrical › Lighting (service)
Issued 19 August 2003
Resolved
Replace light switch cover in Lazarette.
Lifesaving
Issued 27 April 1995
Resolved
CONDUCT THE FOLLOWING DRILLSIN THE PRESENCE OF A MARINE INSPECTOR: FIRE, ABANDON SHIP AND MAN OVERBOARD.
Construction/Loadline
Issued 27 April 1989
Resolved
MAKE THE NON-METALLIC PIPE PENETRATION OF THE #2 VOID/E/R BULKHEAD, LOCATEDSTBD SIDE IAW 46 CFR 182.40.
Construction/Loadline
Issued 10 September 1987
Resolved
MAKE PERMANENT REPAIRS IN WAY OF TEMPORARY REPAIRS OF SUPPORT PLATS ALONG KEEL.
Casualty record · 1
16 May 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2078902
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.