13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2026
Resolved
All marine engineering details, such as boilers, pressure vessels, main and auxiliary machinery, piping, valves, and fittings, must be designed, constructed, and installed in accordance with the provisions of this subchapter. STBD MDE inboard side lube oil leak. Correct w/i 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2026
Resolved 19 June 2026
Resolution: Recieved Photo evidence.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 June 2026
Resolved
Each vessel must be designed and constructed to minimize fire hazards. Paint locker door had wastage not allowing proper containment if case of fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2026
Resolved 19 June 2026
Resolution: Recieved photo evidence.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2026
Resolved
Each vessel of less than 100 gross tons and less than 19.8 meters (65 feet) in length must have navigational lighting in compliance with the applicable navigation rule. Masthead light was not coming on.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2026
Resolved 19 June 2026
Resolution: Recieved photo evidence.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 July 2024
Resolved
No OSV may carry flammable or combustible liquid cargoes in bulk without approval. Vessel must complete a satisfactory inspection of the Methanol transfer system/equipment to include: Material condition of the transfer pump, associated pressure gauge, manual shutoff valve, armored cabling/remote shutdown, and proof of test documentation for safety relief valve discs prior to the carriage of methanol.
46 CFR 125.110
Action required: 705 - Other - as specified
Due 17 July 2024
Resolved 10 July 2025
Resolution: Vessel rep sent proof of certified inspected vents along with methanol pumps replaced and appropriate labels installed on the system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 July 2024
Resolved
A Class-1 watertight door may be installed at any place if the vessel's pilothouse contains a visual indicator showing whether the door is open or closed. Visual indicators for the vessel’s 02 watertight doors were inoperable.
46 CFR 127.230
46 CFR 174.210(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2024
Resolved 17 July 2024
Resolution: Third party tech replaced bulbs and associated breaker. Indicators were proved to be operable.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 July 2024
Resolved
Owners and operators of applicable vessels must establish a master key control system and related provisions for use of master keys, and record keeping. Vessel does not currently have a master key control system.
46 USC 3106(a)(1)
CVC Policy Letter 23-06
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2024
Resolved 31 July 2024
Resolution: Vessel changed locks to keyless and will maintain that policy for this vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 July 2024
Resolved
Life floats must be capable of float-free launching, and if arranged in a group secured by a single painter have a float-free link appropriate for the combined capacity of the life-floats. The person capacity of the weak link installed was scratched out and unclear. A new weak link with clear capacity was installed on the spot.
46 CFR 133.130(b)
Action required: 10 - Deficiency Rectified
Due 17 July 2024
Resolved 17 July 2024
Resolution: A new weak link with clear capacity was installed
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 July 2024
Resolved
Each Emergency Position Indicating Radio Beacon (EPIRB) must be tested monthly. Vessel could not provide record of monthly EPIRB testing. Discussed monthly test requirement with crew, and satisfactorily tested EPIRB.
46 CFR 131.565
Action required: 10 - Deficiency Rectified
Due 17 July 2024
Resolved 17 July 2024
Resolution: Discussed monthly test requirement with crew, and satisfactorily tested EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2024
Resolved
Inspections of lifesaving equipment shall be carried out for proper condition of flotation equipment such as lifebuoys. Lifebuoy outside of port wheelhouse had a non-serviceable hand line. Buoy was replaced.
46 CFR 133.45(b)
Action required: 10 - Deficiency Rectified
Due 17 July 2024
Resolved 17 July 2024
Resolution: Buoy was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 17 July 2024
Resolved
Suitable guards must be installed around rotating machinery. Top guard for sewage pump was not installed. Guard was put into place.
46 CFR 127.330
Action required: 10 - Deficiency Rectified
Due 17 July 2024
Resolved 17 July 2024
Resolution: Guard was put into place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2024
Resolved
Electrical equipment must be installed to minimize accidental personal contact with energized parts. The port side deck locker had an electrical outlet missing a front cover. Cover renewed.
46 CFR 129.200(c)
Action required: 10 - Deficiency Rectified
Due 17 July 2024
Resolved 17 July 2024
Resolution: Outlet cover renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2024
Resolved
Nothing in this part shall be construed as limiting the inspector from making inspections as deemed necessary to be assured of the safety and seaworthiness of the vessel.
The lube oil pressure and jacket water temperature gauges for the port MDE were observed to be inoperable. The pressure gauge on the port MDE fuel filter assembly was found to be bad.
A mechanic attended replacing the fuel filter gauge, and bringing the port MDE gauges into normal operation.
46 CFR 126.100
Action required: 10 - Deficiency Rectified
Due 17 July 2024
Resolved 17 July 2024
Resolution: A mechanic attended replacing the fuel filter gauge, and bringing the port MDE gauges into normal operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2023
Resolved
Each vessel must be designed, constructed and maintained to minimize fire hazards. The STBD Generator's prime mover was leaking oil and pooling on top and dripping into the bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2023
Resolution: Redirected air starter. Seal ok.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 29 August 2023
Resolved
Each vessel must comply with 47 CFR part 80. Vessel only has VHF and did not have a MF, SSB and NAVTEX installed. 705 - Vessel limited to less than 20NM from shore.
Action required: 705 - Other - as specified
Resolved 30 August 2023
Resolution: Installed requried radio to proceed beyond 20NM.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 August 2023
Resolved
When pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. Pressure gage was damaged and hard to read.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2023
Resolved 30 August 2023
Resolution: Received email with pictures of new gages.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2023
Resolved
All installations shall be of marine type engines suitable for the intended serve. Port Engine had vice grip pliers to operate and reset the air intake flapper.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2023
Resolved 8 February 2024
Resolution: Received photo from [name withheld] showing new air flap installiation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2023
Resolved
All installations shall be of marine type engines suitable for the intended serve. Port MDE had a electrical fault that preformed an uncontrolled shutdown multiple times.
Action required: 10 - Deficiency Rectified
Resolved 29 August 2023
Resolution: Electrican rewired faulty connection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 August 2023
Resolved
A fire drill must be held on each vessel, normally on alternate weeks. Vessel had multiple gaps over two weeks where fire drills were not held.
Action required: 10 - Deficiency Rectified
Resolved 29 August 2023
Resolution: MI educated Master, Crew, and Support Mgrs about requirements.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 29 August 2023
Resolved
Abandon ship drills must be held on each vessel, normally on alternate weeks. Vessel had multiple gaps over two weeks where abandon ship drills were not held.
Action required: 10 - Deficiency Rectified
Resolved 29 August 2023
Resolution: MI educated Master, Crew and Vessel Support staff on requirements.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2023
Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to protect crew members, offshore workers, and the vessel from electrical hazards, including fire, caused by or originating electrical equipment and electrical shock. Vessel had multiple ground detection bulbs that were not operable (burnt out.)
Action required: 10 - Deficiency Rectified
Resolved 29 August 2023
Resolution: Vessel replaced bulbs. No grounds indicated with replaced bulbs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 August 2022
Resolved
Each vessel must be energized from at least two sources of electricity.
Port generator would not start without bypassing stop solenoid. Solenoid needs to be replaced.
46 CFR 129.310(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2022
Resolution: Vsl rep provided evidence that generator was operational.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 August 2022
Resolved
Vessel must have adequate emergency lighting.
E-light in engine room, exiting engine room, and port/stbd weather deck are inoperable.
46 CFR 129.440(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2022
Resolution: Vsl rep provided evidence that e-lights were operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 August 2022
Resolved
Suitable guards must be installed around rotating machinery.
Guard for mud pump is not permanently installed. Needs to be bolted in place.
46 CFR 127.330
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2022
Resolution: Vsl rep provided evidence that guard was bolted in place.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 August 2022
Resolved
Electrical equipment must be installed to prevent electrical ignition of flammable vapors.
Junction box on stbd generator is missing cover. Needs to be replaced.
46 CFR 129.200(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2022
Resolution: Junction box was replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 June 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2021
Resolution: new flame screen plugs were installed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 June 2021
Resolved
LIQUID MUD ELECTRIC PUMP WAS NOT OPERATIONAL.
REPAIR LIQUID MUD PUMP
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2021
Resolution: New switch was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2021
Resolved
BELT ON BOW THRUSTER/FIRE MONITOR PRIME MOVER WAS BROKEN.
REPAIR PRIME MOVER.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 11 June 2021
Resolution: New belt was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2021
Resolved
STARBOARD MAIN DIESEL ENGINE RPM AND HOUR GAUGE WERE INOPERATABLE/UNREADABLE.
REPLACE GAUGES AS DESIGNED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 16 June 2021
Resolution: new gauges were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 September 2020
Resolved
Vessel inspection is to determine whether vessel is in safe and seaworthy condition, including fire hazards. Port fuel oil service tank port hole is leaking fuel. Make effective repairs to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2020
Resolution: Port hold satisfactorily sealed; no leaking of oil.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 September 2020
Resolved
Test and inspection of the the main propulsion machinery and auxiliary machinery and of its associated equipment is for safe operation. Port propulsion engine fuel priming pump not mounted to engine. Priming pump was zip-tied to engine. Make effective repairs to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2020
Resolution: Priming pump properly affixed; repairs satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 September 2020
Resolved
Exhaust of internal combustion engines must be insulated from combustible matter. Port propulsion engine, Starboard propulsion engine, and bow thruster engine had exposed exhaust piping. Make effective repairs to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2020
Resolution: Previously exposed exhaust piping covered satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 September 2020
Resolved
Inspection is made to determine whether the vessel is in safe and seaworthy condition, including fire detection equipment. Smoke detectors located in O1 deck passageway and laundry room were inoperable. Make effective repairs to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2020
Resolution: Smoke detectors replaced with new units and performed satisfactory op test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2020
Resolved
Vital systems are those systems that are vital to a vessel's survivability and safety. Ballast piping on the port side of engine room overhead had 4 separate that had pin hole leaks. Make effective repairs to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2020
Resolution: Sections of piping that had leaks were replaced with new piping.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2020
Resolved
Piping systems installed on ships shall have the necessary valves for the safe and efficient operation of the vessel. There was a leaking valve in the dirty oil/ slop discharge piping leaking oil/water on air compressor located below the piping. Make effective repairs to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2020
Resolution: Leaking piping replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2020
Resolved
Test and inspection of the the main propulsion machinery and auxiliary machinery and of its associated equipment is for safe operation. The starboard reduction gear's lube oil level alarm switch was disconnected from the engine and laying in the bilge. Make effective repairs to satisfaction of OCMI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 September 2020
Resolution: Lube oil alarm switch re-attached and performing as designed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 September 2020
Resolved
Each vessel must minimize fire hazards as far as reasonable and practicable; multiple buckets of fuel oil were present on the deck of the engine room, determined to be an unsafe condition by the attending marine inspector. Buckets of excess fuel must be removed as appropriate to ensure safety of vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: Buckets of excess fuel were not present during reinspection.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 September 2020
Resolved
Each vessel must minimize fire hazards as far as reasonable and practicable; bilge had excess oily water present and must be cleaned to minimize hazards.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: Bilge cleaned out to attending MIs' satisfaction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2020
Resolved
Design, installation, and maintenance Electrical equipment on a vessel must be designed, installed, and maintained to prevent electrical ignition of flammable vapors; accumulation of fuel was discovered in battery box, and loose and unconnected wires/poorly maintained cables connected to battery, presenting hazard. Battery box must be cleaned of all fuel and inspected to ensure installation is maintained and protected from fuel intrusion.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: Fuel cleaned out from box and wire nuts removed, proper wiring configurations and repairs confirmed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2020
Resolved
Each cable and wire must be supported so as to avoid chafing or other damage and be protected by metal coverings or other suitable means if in areas subject to mechanical abuse; wiring on engine room alarm panel was exposed and requires rectification to protect from mechanical abuse.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: Cabling adequately protected from mechanical abuse.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 September 2020
Resolved
Valves for removing water or impurities from fuel oil systems will be permitted in machinery space provided such valves are fitted with caps or plugs to prevent leakage; all fuel filters on main engines and generator sets had no plugs on installed on any Racor filters.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: All filters have plugs installed as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2020
Resolved
Protect crew members and vessel from electrical hazards, including fire caused by or originating in electrical equipment and electrical shock; multiple cables and wires identified in engine room suffering from damage and/or improper maintenance. Cables and wires must be appropriately protected to prevent electrical hazards to vessel and crew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: Cables adequately protected to ensure crew safety.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 September 2020
Resolved
Watertight gasket on WTD leading into engine room Watertight doors are designed to withstand a head of water equivalent to the depth from the sill of the door to the bulkhead deck or 10', whichever is greater; watertight door leading to engine room requires proper fitting watertight gasket.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: Gasket replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2020
Resolved
Non-metallic flexible hoses must be in accordance with SAE J1942 to minimize hazards; port side main engine starting air flexible hose presented frayed jacketing and requires replacement to be in compliance with applicable regulations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: Jacketing replaced
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 September 2020
Resolved
Each VSL must carry adequate and up-to-date charts of large enough scale to make safe navigation possible for the intended voyage; vessel's charts provided as back-up to electronic charting were not updated as appropriate. VSL must provide accurate andup to date charts.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2020
Resolution: New and updated charts provided
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 August 2019
Resolved
The Owner or operator of an OSV shall make the vessel available for inspection by a marine inspector each time an accident occurs. Vessel was damaged due to an accident on 03 Aug 19 with the platform Bulwinkle damaging the mast and hull.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2019
Resolved 23 August 2019
Resolution: Cleared to the satisfaction of the CG
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 12 August 2019
Resolved
When the cognizant OCMI deems necessary, the repairs or alterations must be inspected by a marine inspector. Repairs to areas damaged on 03 Aug 19 are to be inspected by a USCG Marine inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 23 August 2019
Resolution: Cleared to the satisfaction of the CG
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 2 July 2019
Resolved
Master had radio license but did not have radio license on board for inspection. Mate's license was expired.
Action required: 10 - Deficiency Rectified
Resolved 22 October 2019
Resolution: Master provided proof of his license. Mate had renewed license.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 5 September 2017
Resolved
Provide NTVRP approval letter with vesesl name and official number
Action required: 705 - Other - as specified
Due 19 September 2017
Resolved 18 September 2017
Resolution: Approved plans were provided to the satisfaction of the marine inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 5 September 2017
Resolved
Provide radio station license with current call sign and vessel name.
Action required: 705 - Other - as specified
Due 12 September 2017
Resolved 11 September 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 15 June 2016
Resolved
Found multiple fixtures with cracked brackets, globes and bulbs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 June 2016
Resolution: Attended vessel verified items corrected
Engineering › Fuel Oil Service System › Filter
Issued 15 June 2016
Resolved
Replace F/O Bowl on bow thruster which is plastic with 1 of metallic type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 June 2016
Resolution: Bowl replaced.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 15 June 2016
Resolved
Opening present in switchboard. Place blanks in openings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 June 2016
Resolution: Verified blanks installed openings.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 15 June 2016
Resolved
Transfer proceedures not posted at transfer location.
Condition: Invalid
Action required: 703 - Prior to bunkering operations
Due 15 June 2016
Resolved 17 June 2016
Resolution: Verified transfer proceedures posted.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 15 June 2016
Resolved
Generator enclosure missing blanks.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 June 2016
Resolution: Blanks placed in enclosure
Electrical › Lighting (service) › Conductor
Issued 15 June 2016
Resolved
Wires at E/R door were not secured. the bracket which held the wires were detached from the bulkhead and not rewelded.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 June 2016
Resolution: Bracket welded
Engineering › Compressed Air System (start air) › Valve
Issued 15 June 2016
Resolved
PRV not tested.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 June 2016
Resolution: PRV's tested
Fire Fighting › Fire Hoses › Condition
Issued 15 June 2016
Resolved
Fire hose in E/R cross threaded.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2016
Resolved 17 June 2016
Resolution: Hose replaced.
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 15 June 2016
Resolved
Replace bushings on both Generator control panels.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 June 2016
Resolution: Bushings replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 15 June 2016
Resolved
P/V valvesnot operational some would not push down for vacuum and some would not pull up for pressure. some were painted and full of sand blast grit. Bench test required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2016
Resolved 17 June 2016
Resolution: Bench test reports supplied. The valves were rebuilt. The representative supplied shipyard drawings which were stamped by ABS and CG approval letters issued to prove the correct settings.
Electrical › Electric Supply System (service) › Cable
Issued 15 June 2016
Resolved
Dead end wires found on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 17 June 2016
Resolution: Verified the wires were pulled.
Communications › Radio Communications › EPIRB
Issued 15 June 2016
Resolved
EPIRB bracket not servicable.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2016
Resolved 17 June 2016
Resolution: Bracket replaced.