Records from 1999 to 2026. Most recent: inspection, 16 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
16 June 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8375888
7 May 2025
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8130154
27 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7943425
3 April 2024
Drydock Exam · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7889191
27 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7724569
23 February 2022
Deficiency Check · Administrative Inspection · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7400193
8 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7219196
23 April 2020
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6942722
20 March 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6645777
6 March 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6637059
27 April 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6398336
11 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6205234
8 March 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6100902
17 February 2017
Hull Examination · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6090519
29 February 2016
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5823693
15 February 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4245115
8 February 2012
Cargo Tank Internal · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4239732
24 February 2011
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3951964
31 January 2011
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3962041
18 December 2008
Re-Inspection · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3381743
4 March 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3158374
17 January 2007
Cargo Tank Internal · Deficiency Check · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2857428
30 January 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2572271
26 April 2005
Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2344348
22 January 2004
Cargo Tank Internal · Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1990430
25 March 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1762583
25 January 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1481263
1 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068877
30 January 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472552
3 April 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429319
5 March 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 86569
10 February 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 766817
27 January 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 210891
30 June 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762725
29 June 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 210888
3 February 1999
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1471857
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 16 June 2026
No resolution recorded
Each muster station and embarkation station must be adequately illuminated by lighting supplied from the emergency source of electrical power. MI observed emergency lighting to be inadequate for survival craft embarkation station located at the stern of the vessel. Due to the location of the fixture, it would not be possible for ambient light to reach embarkation location. Def to be corrected by next dry dock.
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 June 2024
Resolved
Each closing appliance must remain watertight. Engine room watertight door allows air passage at seal.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 June 2024
Resolved 27 June 2024
Resolution: Repaired watertight door.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 June 2024
Resolved
Electrical equipment must provide services necessary and protect crewmembers. Alarm junction box on port main engine is cracked. Spliced cables in engine room passage way not in junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 27 June 2024
Resolution: Electrical installations repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 June 2023
Resolved
Ships must be provided with radio installations capable of complying with the functional requirements prescribed by 80.1081 throughout its intended voyage and as appropriate for the sea area of areas through which it will pass during its intended voyage. Vessel's P/S Forward VHF radios were not able to transmit properly. FCC Tech on-board changing out radios and transmitters as necessary... Cleared 27JUN2023.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2023
Resolution: FCC Technition was onboard with 3 new radios and spare parts.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 June 2023
Resolved
Paint lockers must be constructor of steel. Paint Locker on deck had multiple areas that were wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2023
Resolved 27 July 2023
Resolution: Received email with evidence of repairs being completed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 June 2023
Resolved
Means must be provided for closing in case of fire for machinery spaces. P/S Engine intake dampners were not able to be fully closed to prevent air from entering the engine space.
Action required: 10 - Deficiency Rectified
Resolved 27 June 2023
Resolution: Vessel corrected and was able to seal properly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 June 2023
Resolved
Fire detection systems shall be installed, tested and maintained IAW approperate industry standards and manufacture's specific guidance. Smoke detector dining area was removed and not replaced due to unit not working properly.
Action required: 10 - Deficiency Rectified
Resolved 27 June 2023
Resolution: Vessel installed new smoke detector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 June 2023
Resolved
Fire drills must be held on each vessel, normally on alternate weeks. Vessel had not been preforming and logging drills as vessel went over one month without a fire drill. Educated Master & Vessel Rep.
Action required: 10 - Deficiency Rectified
Resolved 27 June 2023
Resolution: Educated Master and Vessel Rep.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 27 June 2023
Resolved
Abandon ship drills must be held on each vessel, normally on alternate weeks. Vessel had not been preforming and logging drills as vessel went over one month without an abandon ship drill. Educated Masters & Vessel Reps.
Action required: 10 - Deficiency Rectified
Resolved 27 June 2023
Resolution: Educated Masters and Vessel Rep.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 April 2022
Resolved
The bulkhead in each machinery space of each OSV must be watertight to the bulkhead deck; missing valve for the watertight bulkhead penetration below deck plating leading to emergency escape in engine room.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 April 2022
Resolution: Valve placed at penetration.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 April 2022
Resolved
A Class-1 door may be installed if the door is designed to withstand a head of water equivalent to the greater of the depth from the sill of the door to the bulkhead deck or ten (10) feet; two (02) watertight doors in the engine room were not made watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 April 2022
Resolution: Watertight integrity regained by tightening dogs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2022
Resolved
Suitable covers must be installed on each exposed and dangerous place; deck plate above liquid mud valves did not sit flat due to height of the valves, creating safety hazard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 7 April 2022
Resolution: Deck plate now sits flat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2022
Resolved
At each inspection for certification, the vessel must be made available for inspection of fire hazards; diesel leak was found at the bow thruster prime mover fuel filter selector valve. Lighting in port gear locker showed signs of fire damage, replace.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 April 2022
Resolution: Selector valve replaced, diesel leak cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 April 2022
Resolved
Each vessel must capable of providing the quantity of water required of it while meeting any other demands such as a branch line; fire main had notable amount of mud buildup in branch line in the passageway to the engine room and needs flushed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 April 2022
Resolution: Fire main flushed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 5 April 2022
Resolved
Each lifesaving appliance must be in good working order and available for immediate use. Crew failed MOB drill after two attempts.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 April 2022
Resolution: Re-ran drills, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2022
Resolved
Each OSV must have emergency lighting in the vicinity of each survival craft. Emergency lighting OOC in vicinity of life floats.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 April 2022
Resolution: E-lighting fixed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2022
Resolved
Electrical installations must be inspected to determine electrical performance. Found worn / wasted bracket and junction box on top of pilot house. Found non permanent splicing on ice machine. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2022
Resolution: Splicing completed within a junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 5 April 2022
Resolved
Suitable covers must be installed on hot surfaces. Missing STBD MDE and STBD generator exhaust lagging and bracket missing for STBD MDE in passageway. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2022
Resolution: Lagging and bracket replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2021
Resolved
ELECTRICAL CONNECTIONS MUST NOT BE TEMPORARY AND BE MADE WITHIN A SECURE JUNCTION BOX. VSL HAD MULTIPLE ELECTRICAL CONNECTIONS ON THE FLY BRIDGE AND IN THE UTILITY LOCKER ON THE MAIN DECK WHICH WERE NOT SECURE/PERMANENT.VSL MUST MAKE WIRING SECURE/SAFE/PERMANENT. 46 CFR 111.60-3
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2019
Resolved
Provide lifejackets for total persons allowed (20). Vessel is prohibited from departing with greater than 19 persons.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2019
Resolution: Verified proper number of lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2019
Resolved
Provide approved lifebuoys on back deck that meet 46 CFR 160.050 to satisfaction of attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2019
Resolution: Verified satisfactory lifebuoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 March 2019
Resolved
Found an oil leak on the port main oil cooler and the block. Provide a port main engine that meets the requirements of 46 CFR Subchapter "F" to the satisfaction of attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2019
Resolution: Ran main and verified fix of both leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2019
Resolved
Provide RACOR filters with plugs.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2019
Resolution: Verified all filters were plugged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2019
Resolved
Vessel was not able to prove overspeed settings on either generator. Conduct satisfactory overspeed tests to satisfaction of Coast Guard Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2019
Resolution: Vessel provided proof of overspeed tests on both generators.
Fire Fighting › Fire Hoses › Condition
Issued 29 February 2016
Resolved
Fire hose was wasted and leaking
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2016
Resolved 1 March 2016
Resolution: Replaced with new hose.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 29 February 2016
Resolved
Gland packing leaking and spraying water on the fire monitor pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2016
Resolution: repaired packing gland.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 29 February 2016
Resolved
02 fuel valves leaking fuel on fuel transfer manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 29 February 2016
Resolution: Valves pulled and reseated stopping the leaks, corrected on spot.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 29 February 2016
Resolved
Generator overspeed not working on the STB generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2016
Resolved 1 March 2016
Resolution: adjusted overspeeds. Properly working.
Communications › Alarms/Indicators › General Alarm
Issued 29 February 2016
Resolved
General Alarm did not operate properly on Emergency Power, Engineer stated they had a bad battery that needed replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2016
Resolved 1 March 2016
Resolution: Battery was replaced. Alarms working properly.
Engineering › Lubricating Oil Service System › Piping
Issued 24 February 2011
Resolved
Oil supply pipe for bow thruster had a leaky elbow which was covered in a green putty, which also began to leak onto the bow thruster engine. Elbow and pipe need to be replaced and putty removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 March 2011
Resolution: A new elbow joint and pipe was installed into the system.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 24 February 2011
Resolved
Dirty oil pipe running under deck plating on stbd side needs to have a securing bracket installed to prevent it from vibrating and moving freely.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 March 2011
Resolution: a U bolt was installed to secure the pipe.
Documentation › Markings/Placards › Warning Signs
Issued 24 February 2011
Resolved
vessel needed to label vent closures "close in case of fire", mud pump activation switch and ballast manifold piping.
Action required: 705 - Other - as specified
Resolved 1 March 2011
Resolution: All systems labeled with stencils and paint.
Engineering › Compressed Air System (start air) › Valve
Issued 24 February 2011
Resolved
low pressure sensor on top of tank had the top missing and the cable coming out. Repair or replace as necessary to make function properly.
Action required: 705 - Other - as specified
Resolved 1 March 2011
Resolution: Top of control box properly reattached and cable attached to box with a connector.
Documentation › Markings/Placards › Lifejacket Placard
Issued 24 February 2011
Resolved
Vessel needed to add instruction placard for "Vest" type PFD. Vessel had Yoke and vest type, but only instructions for the yoke type.
Action required: 705 - Other - as specified
Resolved 1 March 2011
Resolution: Copies of instructions provided throughout the vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 February 2011
Resolved
Company operated vessel on 2 seperate occasions with an expired COI.
Action required: 705 - Other - as specified
Resolved 28 February 2011
Lifesaving › Lifefloat › Painter
Issued 6 February 2007
Resolved
Replace/Repair spool for lifefloat painter (fairlead ring broken from mount).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 6 February 2007
Resolved
Repair shaft tachometers, fore and aft indicators swapped.
Condition: Improper/Lack of Maintenance
Due 6 March 2007
Resolved 8 February 2007
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 6 February 2007
Resolved
Provide Rudder Angle Indicators that will work independent of Auto Pilot.
Condition: Improper Installation
Due 6 March 2007
Resolved 8 February 2007
Lifesaving › Line-Throwing Appliances › Instructions/Diagrams
Issued 6 February 2007
Resolved
Provide cleaning kit for shoulder line throwing gun (in accordance with Q-spec) and clean.
Condition: Improper/Lack of Maintenance
Due 6 March 2007
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 February 2007
Resolved
Install appropriate breaker bar at generator switch board. (Allows both generator breakers to be thrown)
Condition: Improper Installation
Due 6 March 2007
Resolved 8 February 2007
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 6 February 2007
Resolved
Install appropriate flame screens for fuel/mud and sewage vents.
Condition: Improper Installation
Due 20 February 2007
Resolved 8 February 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 January 2007
Resolved
Label remote fuel shutoff valves on main deck, port and stbd.
Condition: Improper Installation
Due 6 March 2007
Resolved 8 February 2007
Communications › Radio Communications › EPIRB
Issued 26 January 2004
Resolved
Renew EPIRB antenna.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 January 2004
Resolved
Provide 3/8" line for lifebuoys.
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 26 January 2004
Operations/Management › Drills/Instruction
Issued 26 January 2004
Resolved
Provide lifejacket-donning placards for 01-deck staterooms. LEGACY COMPONENT DESC: Safety Orientation
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 26 January 2004
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 26 January 2004
Resolved
Renew bulb for ground detection panel on switchboard.
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 26 January 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 January 2004
Resolved
Provide 12v bulbs for emergency lighting fixtures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 January 2004
Resolved
Renew flexible hoses from governor to clutch actuators on stbd main engine. LEGACY COMPONENT DESC: Hoses
Action required: 705 - Other - as specified
Due 5 February 2004
Resolved 26 January 2004
Engineering › Fuel Oil Service System › Hose
Issued 25 March 2003
Resolved
INSTALL CHAFFING GEAR ON FUEL HOSE ON STARBOARD MAIN ENGINE.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2003
Resolved 25 March 2003
Stability › Watertight Integrity
Issued 25 March 2003
Resolved
TIGHTEN TONNAGE OPENING AT PAINT LOCKER DOOR. LEGACY COMPONENT DESC: PAINT LOCKER
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2003
Resolved 25 March 2003
Lifesaving › Line-Throwing Appliances
Issued 25 March 2003
Resolved
CLEAN LINE THROWING GUN. LEGACY COMPONENT DESC: CONDITION
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2003
Resolved 25 March 2003
Construction/Loadline › Hull › Side Shell
Issued 25 January 2002
Resolved
SEE ENTIRE PLATE SUMMARY IN CERTIFICATES/DOCUMENTATION ACTIVITY.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2002
Resolved 25 January 2002