MAURY USCG vessel records
← All vessels

FRIO IONIAN

Built
1998
Last inspected
2 February 2022
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 February 2022
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9189873
485893
Flag
LIBERIA
Maury page id
psix-485893

Documentation record

Tonnage as PSIX records it5966 - Convention (Subpart B), Net Ton
10447 - Dead Weight, Metric Ton
11417 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 7 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

2 February 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7388731
27 August 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6524590
26 December 2017 ISPS II Exam · PI Safety Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6329136
10 March 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6102371
8 February 2017 COE-Dockside · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6082725
7 February 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6084177
3 February 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5808810

Deficiency record · 6

Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 26 December 2017 Resolved
The condition of the ship and it's equipment shall be maintained to conform to the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Received report that the vessel lost propulsion while underway. The following is required: a report from the Recognized Organization (RO) detailing the cause of the loss of propulsion, the corrective actions taken, and attesting to the full functionality of all associated equipment. 74 SOLAS (14) I/11
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 December 2017
Resolution: Crew replaced faulty solenoid that provides pilot air to the main starting air valves. Class Surveyor inspected repair and tested engine in ahead and astern directions. Survey attached in documents.
Fire Fighting › Combustible Materials › Partial Bulkheads/Decks
Issued 8 February 2017 Resolved
74 SOLAS(97) Ch.II-2/15.4 The aft most crane room has significant leaks; the deck is covered in oil which has pooled in corners of the space and lagging is brown and black with moist oil from deck to overhead spanning over ten feet on forward bulkhead. This space contains the electrical equipment for crane.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 10 March 2017
Resolution: Class survey attest the deficiency found rectified
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 February 2017 Resolved
74 SOLAS(97) Ch. II-2/20.1 In all ships general arrangement plans shall be permanently exhibited for the guidance of the ships officers. Plans shall be kept up to date. There have been multiple alterations to the fire control plan on boards using paper and tape, with no mark of approval attesting to official verification, have no approval stamp. Class boundaries are indistinguishable on all plans.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 10 March 2017
Resolution: Class survey attest the deficiency found rectified
Construction/Loadline › Hull › Weld
Issued 8 February 2017 No resolution recorded
ICLL 66/88 Annex I/I(I) The administration shall satisfy itself that the general structural strength of the ship is adequate. Based upon the general arrangement plan of the ship, there is a suspected compromised weld on the forward most port side ballast tank. This leak was not anchor wash and continued unabated for 5.5 hours.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2018 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 February 2016 Resolved
ILLC ANNEX I/CH2REG25.3- Guard rails fitted on superstructure and freeboard decks shall have at least three courses. The opening below the lowest course of the guard rails shall not exceed 230 mm. The other courses shall not be more than 380 mm apart. Due to damage during cargo operations the guard rails are no longer adequate.40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 February 2016
Resolved 18 February 2016
Resolution: New guard rails were installed and placed into service.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 3 February 2016 Resolved
74SOLAS2014 cons 2014 CH I reg11(a)- The condition of the ship and its equipment shall be maintained to confrom with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Sewage tank has multiple soft patches and damage after class survey.40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 February 2016
Resolved 18 February 2016
Resolution: Sewage tank was fitted with new sewage cover and patches were repaired correctly.

Ownership record