Records from 1982 to 2012. Most recent: inspection, 29 June 2012.
Inspection history · 62
29 June 2012
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4361059
14 January 2011
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3926840
17 March 2009
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3435891
14 July 2008
MTSA Verification · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3260788
5 June 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3227948
20 February 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3150630
15 May 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2931331
21 April 2006
Re-Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2629496
23 November 2005
Internal Structural Exam · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2539481
11 March 2005
Re-Inspection · MTSA Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2307599
10 September 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2192433
20 April 2004
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2048271
5 April 2004
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2037688
16 March 2004
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2025832
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999720
10 July 2003
Hull Examination · Internal Structural Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1842086
18 April 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1779585
1 March 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1752537
21 February 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608163
18 December 2001
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1703829
20 April 2001
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1063179
19 April 2001
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1469678
17 April 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 39671
10 April 2001
Damage Survey · Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1439178
5 February 2001
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1058426
1 May 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 222756
27 December 1999
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1412018
31 August 1999
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1119485
21 April 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 94430
14 October 1998
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 806758
22 June 1998
Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1126405
20 August 1997
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 785304
14 October 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1425808
18 March 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 198784
18 March 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753978
27 November 1995
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1462482
18 September 1995
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1438355
27 October 1994
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1407389
19 December 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 103535
5 November 1993
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 962871
19 October 1993
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1440755
12 August 1993
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1142025
10 June 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1133642
16 November 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 829256
1 October 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1261257
12 November 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1251632
27 September 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 939375
27 June 1991
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1230318
15 February 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 914296
9 January 1991
Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 905917
22 November 1989
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1216299
12 October 1989
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1341217
1 February 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034018
18 November 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1208079
23 June 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1207291
27 November 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313950
16 June 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016667
26 February 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310801
26 June 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294809
10 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1298209
27 November 1985
COI Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1304310
22 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274571
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 17 March 2009
Resolved
Properly secure refrigerators to prevent movement in heavy seas.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2009
Resolved 20 March 2009
Stability › Watertight Integrity › General
Issued 17 March 2009
Resolved
Survey electrical penetrations through watertight bulkheads and install missing compression grommets as necessary.
Condition: Improper Installation
Due 17 June 2009
Resolved 8 April 2010
Resolution: COI Renewal, all items inspected satisfactory.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 March 2009
Resolved
Opereator failed to log monthly EPIRB test. Log the test and schedule a deficiency check for June
Condition: Improper/Lack of Maintenance
Due 16 June 2009
Resolved 8 April 2010
Resolution: COI renewal, all items inspected satisfactory
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 17 March 2009
Resolved
Renew or properly repair lower engine room air receiver.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2009
Resolved 20 March 2009
Resolution: New Air Reveivers installed
Fire Fighting › Fire Hoses › Condition
Issued 17 March 2009
Resolved
Conduct a hydrostatic test of the vessel's fire hoses to 100 PSI
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 20 March 2009
Resolution: New hoses installed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2009
Resolved
Install machinery guard over exposed shaft on the cargo pump.
Condition: Unknown
Due 27 March 2009
Resolved 20 March 2009
Accommodation/Occupational Safety › Potable Water System › General
Issued 17 March 2009
Resolved
Provide a pressure reelief valve for the potable water hydrostatic tank.
Condition: Improper Installation
Due 27 March 2009
Resolved 20 March 2009
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 20 February 2008
Resolved
Engine room bilges contained excess amount of oily waste mixture. MSM Ch. B6.D.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2008
Resolved 22 February 2008
Resolution: [name withheld] cleared
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 20 February 2008
Resolved
Shaft packing glands excessively loose, MSM Ch.B3.D
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2008
Resolved 22 February 2008
Resolution: [name withheld] Cleared
Engineering › Steering Gear System › Interlock
Issued 20 February 2008
Resolved
Rudder steering gear system was not properly arranged to prevent rudder from reaching rudder stops
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2008
Resolved 22 February 2008
Resolution: [name withheld] cleared
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 March 2005
Resolved
Replace all emergency light batteries in engine room
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2005
Resolution: Batteries in emergency lights replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 11 March 2005
Resolved
Ensure overspeed trips on both main diesel engines are operating at the proper RPM in the presence of a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2005
Resolution: Overspeeds adjusted and tested working properly
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 March 2005
Resolved
Replace battery on emergency light in rudder compartment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2005
Resolution: Battery replaced, light working properly.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 11 March 2005
Resolved
Effect changes to fire control plan to show rescue platform location not rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2005
Resolution: Fire control plan changed removed rescue boat.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 11 March 2005
Resolved
Update watch quarter station bill to show rescue platform procedures during man overboard drill.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2005
Resolution: Station bill shows rescue platform instructions
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 March 2005
Resolved
Conduct man overboard drill in the presence of a marine inspector utilizing either provided rescue boat or rescue platform.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2005
Resolution: Man overboard drill conducted to the satisfaction of a marine inspector.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 April 2004
Resolved
The M/V AMERICAN DISCOVERY (O.N. 57005) operated without a valid COI between 18 Dec 02 and 16 Mar 04 (453 days). Vessel is a subchapter I offshore supply vessel which did not receive the required periodic SIP performance review due on 18 Dec 02 as per 46 CFR 8.544 (a).
Action required: 705 - Other - as specified
Resolved 19 May 2006
Stability › Watertight Integrity
Issued 25 July 2003
Resolved
Found doubler welded to stbd bulkhead in #6 port ballast tank. Bulkhead had puncture where doubler was welded. Instructed vessel rep to repair bulkhead to original manufacture and then reweld doubler to renewed bulkhead.
Action required: 705 - Other - as specified
Resolved 30 July 2003
Resolution: Inspected weld and air tested insert on stbd bulkhead in #6 port ballast tank.
Construction/Loadline
Issued 19 October 1993
Resolved
PROPERLY WELD ENGINE ROOM SIDE OF INSERT IN OVERHEAD STARBOARD SIDE NEAR AIR RECEIVERS.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Electrical
Issued 19 October 1993
Resolved
PROVE PROPER OPERATION OF PORT AND BOW #1 RUNNING LIGHT FUSE FAILURE ALARMS.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Unknown
Issued 9 January 1991
Resolved
SUBMIT FOR COAST GUARD APPROVAL TEST PROCEDURES FOR ENGINEROOM AUTOMATION ALARM PANELS.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Unknown
Issued 9 January 1991
Resolved
INSTALL A SHUTDOWN FOR MAIN ENGINES IN THE WHEELHOUSE.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Unknown
Issued 9 January 1991
Resolved
INSTALL IN ENGINEERS STATEROOM AN ALARM ON THE ENGINEERS CALL CIRCUIT.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Unknown
Issued 9 January 1991
Resolved
INSTALL A SHORE POWER BREAKER ON MAIN SWITCHBOARD.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Unknown
Issued 9 January 1991
Resolved
INSTALL A NEW BREAKER FOR BALLAST PUMP ON MAIN SWITCHBOARD.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Unknown
Issued 9 January 1991
Resolved
PROVIDE A RESCUE BOAT.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Unknown
Issued 9 January 1991
Resolved
CONDUCT A TEST OF THE APPROVED TEST PROCEDURES IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Unknown
Issued 9 January 1991
Resolved
PLACE ONBOARD UPDATED FIRE AND SAFETY PLAN.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Unknown
Issued 9 January 1991
Resolved
INSTALL A MEANS TO START THE FIRE PUMP FROM THE WHEELHOUSE AND INSTALL A FIRE MAIN PRESSURE GAUGE.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Navigation
Issued 18 November 1988
Resolved
PROVE PROPER OPERATION OF SOUND POWERED PHONE IN STEERING ROOM.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Engineering
Issued 18 November 1988
Resolved
PROVE PROPER OPERATION OF BOTH MAIN PROPULSION OVERSPEED TRIPS.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Engineering
Issued 18 November 1988
Resolved
PROVE PROPER OPERATION OF BOTH MAIN PROPULSION LOW LUBE OIL SHUTDOWNS.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Electrical
Issued 18 November 1988
Resolved
PROVE PROPER OPERATION OF GENERATOR LIGHTS ON ALARM PANEL.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Fire Fighting
Issued 18 November 1988
Resolved
PROVE PROPER OPERATION OF REMOTE VENTILATION SHUTDOWN FOR MACHINERY SPACE.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Unknown
Issued 23 June 1988
Resolved
PROPERLY REPAIR CRACKED BOTTOM PLATE LOCATED ON STBD SIDE IN WAY OF #5 BALLAST TANK, INSERT 4' X 4' X 3/8".
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Fire Fighting
Issued 27 November 1987
Resolved
PROVIDE MEANS TO WEIGH HOSE REEL CO2 BOTTLES IN PROT ENGINE ROOM ACCESS TRUNK.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Navigation
Issued 27 November 1987
Resolved
PROVIDE CURRENT TIDAL CURRENT TABLES FOR AREA OF OPERATION.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987
Construction/Loadline
Issued 27 November 1987
Resolved
REPAIR FRACTURES TO AFT ROLLING STOCK AT STERN TO STBD OF C/L AND IN RUB RAILS AT STERN TO PORT OF C/C AND IN RUB RAIL PORT SIDSE STERN QUARTER.
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987