MAURY USCG vessel records Sign in
← All vessels

BALTIC JASMINE

BALTIC JASMINE is a 1998 freight ship. The Coast Guard has recorded 41 inspections since 2001, most recently in November 2024, along with 18 deficiencies and 7 operational controls.

Records from 2001 to 2024. Most recent: inspection, 8 November 2024.

Built
1998
Last inspected
8 November 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9181156 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
485992
Flag
CYPRUS
—
Maury page id
psix-485992

Inspections, by type

…with no type recorded18
Years with a record 15 calendar years (2001–2024)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10110 - Dead Weight, Metric Ton
15845 - Displacement, Metric Ton
9859 - Convention (Subpart B), Gross Ton
5124 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 41

8 November 2024 PSC A · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8032272
20 January 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7382916
11 July 2020 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6994445
24 June 2020 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6985282
17 December 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6599149
14 December 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6597747
15 February 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6355609
15 February 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6355618
6 March 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6096950
4 January 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6065515
12 January 2016 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5793997
6 February 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4237127
11 December 2011 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4206026
7 December 2011 ISPS I Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4203480
16 February 2011 ISPS II Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3946272
16 February 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3954167
8 December 2009 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3646475
14 April 2009 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3452030
23 March 2009 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3438757
26 February 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3424683
10 February 2009 MARPOL Annex I Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3415697
9 February 2009 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3415740
20 January 2009 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3396877
9 December 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3377269
24 November 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3368879
28 August 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3311553
26 August 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3309162
11 December 2007 ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3109971
17 September 2007 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3059686
4 September 2007 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3048344
29 June 2007 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2977769
11 September 2006 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2777835
27 October 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2523660
12 May 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2356376
16 March 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2312186
19 January 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2276380
11 October 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1688709
27 September 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1680316
26 September 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1681334
25 July 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 292176
18 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286073

Deficiency record · 18

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2024 Resolved
The conditon of the ship and its equipment shall be maintained to conform with provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed jacket water leak on main engine cylinder #2. Crew instaled plywood containment to direct and collect jacket water leak. 74SOLAS(20) I/11 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2024
Resolution: engine overhaul, received class report, cleared
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 November 2024 Resolved
Before ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO observed that the painter line was disconnected from the weak link. 74SOLAS(97)III/19.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2024
Resolution: rectified on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 November 2024 Resolved
The machinery, boilers and other pressure vessels, associated pipiing systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO identified temporary repair on bilge/ballast pump piping. 74SOLAS(04)II-1/26 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2024
Resolved 12 November 2024
Resolution: received class report of completed repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 November 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation. PSCO noticed dent in hull of lifeboat on port side of ship on STBD aft exposing fiber glass. 74SOLAS(04)I/11 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2024
Resolved 12 November 2024
Resolution: received class report of fiberglass repairs completed on lifeboat
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 November 2024 Resolved
The conditon of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port and starboard side lifeboats had loose and broken hoses that connected off the sea water isolation valve to the bilge. 74SOLAS(04)I/11 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2024
Resolved 12 November 2024
Resolution: received clas report that the bilge water isolation valve hoses were replaced.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 6 February 2012 Resolved
0740 Pumps- Fire extinguishing appliances shall be kept in good working order and availiable for imidiate use at all times. Vessels second fire pump, the bilge and ballast pump packing gland was tightened which seized motor from turning shaft. Crew intentionally siezed shaft to prevent discharge of cargo bilge water, failing to realize pump is a fire pump. Solas 2009 Cons. Ch II-2 reg 21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2012
Resolution: Received class survey report that packing glands were replaced with new ones, operational test carried out; found in order.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 6 February 2012 Resolved
0740-pumps- Fire extinguishing appliances shall be kept in good working order and availiable for immediate use at all times. Vessels fire/general service pump packing gland leaked a substantial amount of water during operation. Solas 2009 Cons Ch II-2 Reg 21. Class has extended the DEF until 6APR2012
Due 6 April 2012
Resolved 10 December 2012
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 February 2012 Resolved
0950-Electrical equipment in general- The emergency diesel generator shall be ready at all times for automatic starting. Engineers attempted four times unsuccessfully to start the generator in front of port state control officer. 2001 Cons. Ed. II-1 Reg 44.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2012
Resolution: Received class survey report stating EDG was repaired and tested satisfactory, USCG also witnessed test of EDG under black out and tested steering satisfactory.
Operations/Management › Drills/Instruction › Fire
Issued 6 February 2012 Resolved
3032-Drills- Master and crew shall be familiar with essential shipboard procedures relating to the safety of the ship. during first fire drill, crew failed to properly don fire suits, leaving exposed skin and not putting on SCBA mask with air prior to entering space to fight the fire. During second drill, crew member did not properly don SCBA mask to his face, causing rapid air loss and leaving
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2012
Resolution: USCG witnessed satisfactory fire drill in the ship office. Crew dressed out correctly and donned SCBA correctly.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 February 2012 Resolved
2565-Certification,Veonductrification, and control- It is recommended you conduct an external audit of safety management system and provide findings to COTP Houston-Galveston.
Due 20 February 2012
Resolved 9 February 2012
Resolution: Received audit report from class surveyor.
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Check (air start)
Issued 16 February 2011 Resolved
1410 - Propulsion Main Engine - Vessel reported to Sector Delaware Bay a Marine Casualty for a Loss of Propulsion after losing pressure in the Start Air System. Crew identified a leak in the Start Air System caused by a damaged O-ring in the Start Air Exhaust Valve on the # 2 Cylinder. Cite: 74 SOLAS (09 Cons Ed.) Ch. I. Reg. 11(a).
Action required: 705 - Other - as specified
Due 16 February 2011
Resolved 16 February 2011
Resolution: Vessels crew replaced the O-ring in the Start Air Exhaust Valve on the # 2 Cylinder and tested the Main Engine successfully, ahead and astern in the presence of the Port State Control Officer (PSCO).
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 February 2009 Resolved
In accordance with 33 CFR §164.55, you are granted a deviation of the Navigation Safety Regulations for an inbound transit of U.S. waters into the Port of Port Hueneme with an inoperable 3 centimeter radar system. You cannot depart until this equipment is repaired and fully functional.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2009
Resolution: Received a technical report attesting to the repairs of the 3 cm radar system. LOD cleared, deffeciency cleared.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 10 February 2009 Resolved
Following a near-miss pollution incident aboard the ship, is was determined there were no written procedures for internal transfer ot heavy fuel oil. Ensure all internal transfer procedures are addressed with a written procedure.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 March 2009
Resolution: Internal transfers are now addressed in the Vesel transfer Procedures.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 10 February 2009 Resolved
Vessels Safety Management System did not address all internal transfer procedures, ensure vessel's Safety Mgmt. System addresses all internal transfer procedures
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 March 2009
Resolution: Safety Management System now addresses internal transfer procedures.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 9 December 2008 Resolved
Vessel has not conducted a safety inspection of engine room fire prevention items in accordance with vessel's SMS document MK-3H-07-06-04 dated 12 Mar 1999. SMS requires engine room fire prevention check list to be completed monthly. Fire prevention checklist was last completed on 29 Oct 2008. 30a, c SOLAS 74 as amended Chapter IX Reg 3 ISM Code 10.4
Action required: 705 - Other - as specified
Resolved 10 December 2008
Resolution: In the presence of NKK, the vessel filled out a fire prevention check list on 10 Dec 08. Additional training was given to the C/E by the ship''s superintendent regarding SMS.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 9 December 2008 Resolved
C/E appears to have inadequate knowledge of SMS requirements despite the numerous deficiencies identified in this exam. Vessel was unable to provide documentation of non-conformity reports submitted and the safety check report done on 29 Oct 2008, signed by C/E stated all equipment was in good condition. 30 a, c SOLAS 74 Chap IX Reg 3 ISM Code 10.4
Action required: 705 - Other - as specified
Resolved 10 December 2008
Resolution: All non-conformity reports made to the company during the attendance of NKK (class). New short term SMC issued to the vessel.
Fire Fighting › Fire Hoses › Condition
Issued 9 December 2008 Resolved
PSCO found three fire hoses that were tested and found unserviceable in that they leaked excessively, and one semi-portable foam fire extinguisher with an unserviceable nozzle assembly. The vessel has no spare fire hoses. Class is required to attend the vessel and survey E/R firefighting equipment. 17 a, c SOLAS 74 (as amended) Chapter II-2, Reg 14.2.2
Action required: 705 - Other - as specified
Resolved 10 December 2008
Resolution: NKK attended. Found 5 additional hoses to be bad (totaling 8 bad hoses). 10 hoses brought on board and placed in locations of bad hoses. The two extra hoses were stored as spares.
Engineering › Fuel Oil Service System › Piping
Issued 9 December 2008 Resolved
Numerous leaks/pools of fuel were found in E/R from vital systems to include, but not ltd to, fuel oil purifying system piping as evidenced by oil soaked lagging on hot oil lines &the pooling of oil under all gens. PSCOs observed the substandard practice of using over 40 buckets for catching waste/leaking oil from machinery that were being stored haphazardly thruout the E/R, creating a safety haz.
Action required: 705 - Other - as specified
Resolved 10 December 2008
Resolution: As per NKK, oil was cleaned up in engine room and leaks were repaired. All oil catching/stowage buckets were removed from the E/R.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.