MAURY USCG vessel records Sign in
← All vessels

EVENING STAR

EVENING STAR is a 1976 offshore supply vessel. The Coast Guard has recorded 18 inspections since 1982, most recently in August 1992, along with 22 deficiencies.

Records from 1982 to 1992. Most recent: inspection, 3 August 1992.

Built
1976
Last inspected
3 August 1992
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7433842 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
RUSSIA
—
Maury page id
psix-48619

Inspections, by type

…with no type recorded16
Years with a record 9 calendar years (1982–1992)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1084 - Convention (Subpart B), Gross Ton
341 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

3 August 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 667130
1 July 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 39241
26 March 1990 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 336186
22 March 1989 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 329271
23 March 1988 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 322865
16 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010415
16 March 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008633
11 September 1985 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1296226
15 May 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 984324
17 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983465
17 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291192
2 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977370
25 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283139
16 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972538
16 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291194
16 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291203
25 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965409
15 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966110

Deficiency record · 22

Engineering
Issued 26 March 1990 Resolved
VESSEL'S OILY WATER SEPARATOR WAS INOPERATIVE AND MISSING THE OIL MONITOR SWITCH. VESSEL HAD SWITCH WAITING FOR PICK-UP IN SITKA. [name withheld] ON 29MAR90. OWS WORKED PROPERLY
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 26 March 1990 Resolved
VSL DID NOT HAVE ANY FIXED PIPING TO THE WEATHER DECK FOR DISCHARGING OILY WASTER TO A RECEPTION FACILITY
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 26 March 1990 Resolved
ORIGINAL VESSEL DOCUMENT COULD NOT BE PRODUCED FOR THE BOARDING OFFICER. MASTER PRODUCED ORIGINAL DOCUMENT ON 29MAR90
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 22 March 1989 Resolved
NO CERT. OF FINANCIAL RESP. ON BOARD THE VESSEL. VSL IS DOCUMENTED AT 994 GT.
Condition: Unknown
Due 24 March 1989
Resolved 22 March 1989
Construction/Loadline
Issued 15 May 1985 Resolved
REPAIR OR ADJUSTALL WATERTIGHT DOORS IN THE MACHINERY SPACE.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985
Deck/Cargo
Issued 15 May 1985 Resolved
REPLACE OR REPAIR THE FLAME SCREEN TO #2 PORT FULE TANK VENT.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985
Deck/Cargo
Issued 16 March 1984 Resolved
(CONTINUING E-3) FACTORY OPERATION FOR RELIEF VALVES.
Condition: Unknown
Due 16 March 1984
Resolved 16 March 1984
Deck/Cargo
Issued 16 March 1984 Resolved
PRIOR TO PUTTING INTO SERVICE NO. 1 AND NO. 2 STARBOARD DRY MUD TANKS DEMONSTRATE IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR THE SATIS-
Condition: Unknown
Due 16 March 1984
Resolved 16 March 1984
Deck/Cargo
Issued 16 March 1984 Resolved
RENEW, HYDROSTATICALLY TEST OR REMOVE OIL TRANSFER HOSE FROM VESSEL.
Condition: Unknown
Due 16 March 1984
Resolved 16 March 1984
Engineering
Issued 16 March 1984 Resolved
REPAIR OR REPLACE OVERSPEED TRIP TO PORT MAIN ENGINE AND DEMONSTRATE SATIS-FACTORY OPERATION IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 16 March 1984
Resolved 16 March 1984
Unknown
Issued 16 March 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V BACCARA, O.N. 570891.
Condition: Unknown
Due 16 March 1984
Resolved 16 March 1984
Electrical
Issued 25 August 1982 Resolved
LEAD-LINE BATTERY BOXES IN ENGINE ROOM AND PILOT HOUSE
Condition: Unknown
Due 25 August 1982
Resolved 25 August 1982
Electrical
Issued 25 August 1982 Resolved
REPAIR SOUND POWERED PHONE SYSTEM. THROUGHOUT VESSEL AND MAKE AVAILABLE FORTEST.
Condition: Unknown
Due 25 August 1982
Resolved 25 August 1982
Electrical
Issued 25 August 1982 Resolved
REPAIR CONSELECT ALARM PANEL IN ENGINE ROOM FOR MAIN ENGINE AND GENERATOR ALARMS AND MAKE AVAILABLE FOR TEST.
Condition: Unknown
Due 25 August 1982
Resolved 25 August 1982
Electrical
Issued 25 August 1982 Resolved
REPAIR ELECTRICAL CABLE RUN FOR FORWARD MAST THROUGH CHAIN LOCKER.
Condition: Unknown
Due 25 August 1982
Resolved 25 August 1982
Fire Fighting
Issued 25 August 1982 Resolved
REPAIR SOFT PATCH ON THE FIRE PUMP SUCTION LINE AND MAKE AVAILABLE FOR TEST.
Condition: Unknown
Due 25 August 1982
Resolved 25 August 1982
Lifesaving
Issued 25 August 1982 Resolved
PROVIDE ONE ACCEPTABLE RESCUE BOAT.
Condition: Unknown
Due 25 August 1982
Resolved 25 August 1982
Lifesaving
Issued 15 March 1982 Resolved
REPLACE FOLLOWING EQUIPMENT: (1) ALL WATER FOR EACH RAFT 68 CANS EACH (2) GLUE (3) INFLATION HOSE ONE FOR EACH RAFT.
Condition: Unknown
Due 22 April 1982
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 15 March 1982 Resolved
AT NEXT DRYDOCK RENEW STARBOARD SIDE WATERTIGHT DOOR TO ENGINE ROOM ESCAPE TRUNK ON MAIN DECK AND ON ENGINE ROOM LEVEL.
Condition: Unknown
Due 1 July 1982
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 15 March 1982 Resolved
REPLACE COUPLING BETWEEN FWD GENERATOR AND POWER TAKE OFF FOR FIRE MONITOR PUMP AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 1 May 1982
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 15 March 1982 Resolved
REPLACE OVERSPEED TRIP ON FORWARD GENERATOR
Condition: Unknown
Due 15 April 1982
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 15 March 1982 Resolved
REPLACE OUT OF DATE HYDROSTATIC RELEASES FOR LIFERAFTS WITH TWO NEW ONES.
Condition: Unknown
Due 15 April 1982
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.