← All vessels
PREDATOR
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named PREDATOR
PREDATOR is a 1975 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1985, most recently in September 2024, along with 180 deficiencies and 9 operational controls.
Records from 1985 to 2024. Most recent: inspection, 5 September 2024.
- Built
- 1975
- Last inspected
- 5 September 2024
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 180 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
570899
WDL9559
48621
Flag
UNITED STATES
367397080
Maury page id
psix-48621
Inspections, by type
…with no type recorded12
Years with a record
37 calendar years (1985–2024)
The 86 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)37.7 ft × 11.3 ft × 6.1 ft
Registered tonnagegross 18 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 30 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
12 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL9559MMSI 367397080 · active · compulsorily equipped · granted 30 January 2021, expires 30 January 2031
WDE7745MMSI 367397080 · expired · compulsorily equipped · granted 27 February 2009, cancelled 4 May 2019
WCX6838MMSI not assigned · expired · compulsorily equipped · granted 18 August 1997, cancelled 20 October 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 86
5 September 2024
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7985311
13 December 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7837783
27 September 2023
Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7799216
11 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7619354
10 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7607176
11 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7378077
13 December 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7367127
5 October 2021
Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7327393
16 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7138574
12 January 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7123363
25 September 2019
Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6820455
3 September 2019
Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6803170
13 December 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6595308
4 December 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6319866
31 October 2017
Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6298566
13 September 2017
Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6266104
20 August 2017
Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6247221
20 August 2017
Type not recorded
No type recorded · Station Vallejo · USCG Southwest District (CGD-SW) · Activity 6250784
24 October 2016
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6028824
30 November 2015
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5772694
7 October 2015
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5737942
1 October 2015
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5732936
1 October 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5733421
27 August 2014
Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4961820
31 January 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4232525
4 January 2012
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4218420
14 December 2010
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3899037
29 April 2009
Hull Examination · Simplified Stability Test · Plan Review "T" Boat · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3558191
18 July 2008
Type not recorded
No type recorded · Station Golden Gate · USCG Southwest District (CGD-SW) · Activity 3272216
31 January 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3127973
13 July 2007
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3034774
25 April 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2920012
22 March 2007
Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2890882
17 October 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2802632
30 March 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2611788
19 April 2005
Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2323103
3 March 2005
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2301725
6 March 2004
Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2014052
20 February 2003
Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1733417
4 January 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1476613
30 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772602
1 February 2001
Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1410482
14 March 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1048753
15 February 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1361336
2 December 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 811996
29 November 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1045799
28 November 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 83717
12 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1125663
29 January 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790531
26 January 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805418
7 January 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 815060
24 February 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1118182
24 April 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388267
9 January 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1097307
12 August 1996
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1090029
28 February 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1078840
12 January 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1192264
17 May 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1237100
28 April 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1431514
24 April 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1171303
9 February 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1164370
20 January 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851171
15 November 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 685223
13 August 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1151841
1 August 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1157871
21 May 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138941
23 March 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1150820
19 January 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1139781
11 December 1992
Drydock Extension · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828790
8 December 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839629
30 November 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 829394
4 November 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 941775
19 May 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 946995
18 May 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1255418
17 March 1992
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1267678
4 April 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1228903
22 March 1991
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 997767
8 March 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1226673
25 April 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1219057
18 December 1989
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 901828
3 April 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1037078
3 March 1988
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1029513
20 September 1987
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1015879
22 April 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1033260
11 March 1986
Credit Drydock · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 997907
15 March 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1289745
Deficiency record · 180
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline, such as a lazarette. Forward bilge high water alarm not present, install to MI satisfaction.
46 CFR 182.530(a)(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 September 2024
Resolved
A hatch exposed to the weather must be water tight... Aft hatch going to lazarette had a torn gasket, replace to MI satisfaction.
46 CFR 179.360(a)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 September 2024
Resolved
Each vessel must have the following... As used in this section, “currently corrected” means corrected with
changes contained in all Notices to Mariners published
by the National Geospatial-Intelligence Agency...
reasonably available to the vessel. Vessel's Local
Notice to Mariners was outdated. Replace to MI satisfaction.
33 CFR 164.33 (a) & (c)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 September 2024
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crew members... Each EAP must include education and training on drug use for crew members and the employer's supervisory personnel as provided below: Each EAP education program must include at least the following elements: display and distribute of informational material; display and distribution of community service hot-line telephone number number for crew member assistance, and display distribution of the employers policy regarding drug and alcohol use in the workplace. MI observed no EAP information publicly available, display to MI satisfaction.
46 CFR 16.401(a)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 December 2023
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Missing Fire-boy annual servicing report.
46 CFR 176.810
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 December 2023
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of §80.1101(c)(2).
VHF radio missing no GPS and MMSI.
46 CFR 184.502
47 CFR 80.905 (a)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 December 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shut off valve not labeled.
46 CFR 185.608
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2023
Resolved
Each lighting branch circuit must be protected against over current either by fuses or circuit breakers rated at not more than 30 amperes. No over current protection for main cabin light switch.
46 CFR 183.380 (g)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2023
Resolved
Over current devices capable of carrying the starting current of the motor must be installed to protect motors, motor conductors. No over current protection on anchor windless.
46 CFR 183.380 (h)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2023
Resolved
Battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries. Battery missing box covers.
46 CFR 183.354 (a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets. No fire buckets on board.
46 CFR 181.610
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 December 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Life float missing light.
46 CFR 180.175(d)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 December 2023
Resolved
Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Paddles not latched to life float.
46 CFR 180.175 (f)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 December 2023
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers:On each life float and buoyant apparatus. Life float missing vessel name.
46 CFR 185.604 (a)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2023
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life
buoy. Water light not tied off and secured to the ring
buoy properly.
46 CFR 180.70 (d)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2023
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Missing bilge pick up strainer.
46 CFR 182.510 (b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2023
Resolved
Cable and wire for power and lighting circuits must: Meet Section 310–13 of NFPA 70. Lazarette high water alarm wire broken.
46 CFR 183.340 (d)(1)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2023
Resolved
Each pressure type wire connector and lug must meet UL 486A. Housing nuts on found used on wiring in the lazarette.
46 CFR 183.340 (I)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 13 December 2023
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. MSD valve was found open.
33 CFR 159.7 (b)
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 11 January 2023
Resolved
Each EPIRB must be tested monthly. EPIRB is not being tested monthly. Master of vessel shall ensure that each EPIRB must be tested and logged on a monthly basis.
46 CFR 185.728(a)
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 January 2023
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Vessel was missing FCC Telephony Certificate.
46 CFR 184.502
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 January 2023
Resolved
Vapor barriers must be provided in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Machinery and fuel tank spaces lack vapor tightness. Vessel shall make all bulkheads vapor tight.
46 CFR 177.405(e)
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 January 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from hazards. Machinery room had an exposed wire leading into a J box located on the aft bulkhead of the space which creates an unsafe condition.
46 CFR 183.200(b)
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 January 2023
Resolved
All cable and wire must be installed with metal supports spaced not more than24 inches apart. Vessel has multiple wires suspended without support.
46 CFR 183.340(b)(4)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 December 2022
Resolved
Annual inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel is overdue for 2022 annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 January 2022
Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. 03 Deck rail stanchions mounts and several stanchion base mounts were found with cracks. Renew/replace rail and base mounts.
46 CFR 177.35-1 (a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 January 2022
Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. Wooden stanchion mounting support port side forward had split and was no longer secure. Submit repair proposal to renew wood stanchion mounting support.
46 CFR 177.35-1(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 January 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 04 Kapok life jackets were not in good or serviceable condition. Life jackets need to be replaced to meet COI requirements. Vessel is limited to operating with 18 Adults and 02 Children.
46 CFR 180.71(a)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 January 2022
Resolved
Each link certified by the manufacturer to meet the requirements of this subpart must have a corrosion resistant, waterproof tag attached to it. Both Buoyant Apparatus links are missing tags, MIs are unable to verify breaking strength. Attach missing tags to weak links.
46 CFR 183.420
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 January 2022
Resolved
Each navigation light must meet the technical standards of the applicable Navigation Rules. Unable to verify if red and green running lights are visible from 2 miles away IAW applicable Navigation Rules, due to the visible condition of the lens. Both port and stbd running light lenses need to be replaced.
46 CFR 160.073-20(a)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 January 2022
Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. 02 buoyant apparatus paddles are shorter than the required 4 ft. Both paddles need to be replaced.
46 CFR 180.175(f)(2)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 January 2022
Resolved
Connections must be made to battery terminals with permanent type connectors. Battery connector on the negative terminal post was found loose. Crew tighten connector nut, satisfactory.
46 CFR 183.350(d)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 January 2022
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on
which the unit is installed. The hydrostatic release unit is not marked with installation or expiration date.
Crew member marked hydrostatic release unit with expiration date.
46 CFR 185.740(b)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 December 2021
Resolved
Annual inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel is overdue for 2021 ANNUAL INSPECTION.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2021
Resolved
SHUTOFF VALVES, INSTALLED SO AS TO CLOSE AGAINST THE FUEL FLOW, MUST BE FITTED IN THE FUEL SUPPLY LINES, ONE AT THE TANK CONNECTION AND ONE AT THE ENGINE END OF THE FUEL LINE TO STOP FUEL FLOW WHEN SERVICING ACCESSORIES. THE SHUTOFF VALVE AT THE TANK MUST BE MANUALLY OPERABLE FROM OUTSIDE THE COMPARTMENT IN WHICH THE VALVE IS LOCATED, PREFERABLY FROM AN ACCESSIBLE POSITION ON THE WEATHER DECK. WHEN THE OPERATOR CLOSED THE VALVE MANUALLY FROM THE DECK, MI OBSERVED THE VALVE DID NOT CLOSE TO STOP FUEL FROM TANK.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 February 2021
Resolved
AT EACH SUBSEQUENTIAL INSPECTION MI MAY REQUIRE THAT A MAN OVERBOARD DRILL BE HELD UNDER SIMULATED EMERGENCY CONDITIONS. VESSEL WAS NOT ABLE TO GET UNDERWAY DUE TO DEFICIENCY DISCOVERED DURING INSPECTION.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 16 February 2021
Resolved
VESSEL THAT HAS ON BOARD FCC TYPE CATERGORY 1 406 MHz EPIRB MUST INSTALLED TO AUTOMATICALLY FLOAT FREE AND ACTIVATE. RESTIRCTED IN OPERATION OF 3 NM.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 February 2021
Resolved
DISCHARGE ENDS OF VENT PIPE SHALL BE HIGH ABOVE THE WATERLINE AND REMOTE FROM ANY HULL OPENINGS AND SHALL TERMINATE IN U-BENDS AS HIGH ABOVE DECK AS POSSIBLE. MI
OBSERVED SHARP BENDS ON PORT AND STARBOARD DISCHARGE VENT PIPES. 46 CFR 182.20-35(3)(c) OLD T
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 February 2021
Resolved
DISCHARGE ENDS OF VENT PIPE SHALL BE FITTED WITH REMOVABLE FLAME SCREENS AND PERMIT CLEANING OR RENEWAL OF FLAME SCREENS OR ARRESTOR ELEMENTS. MI OBSERVED ON STARBOARD FUEL TANK VENT WAS PARTIALLY BLOCKED BY DIRT AND PAINT. 46 CFR 182.20-35(3)(d) OLD T
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2021
Resolved
THE NAME OF VESSEL MUST BE MARKED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH LIFE FLOAT AND BE MARKED WITH TYPE II RETRO-REFLECTIVE MATERIAL.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2021
Resolved
EACH RING LIFE BOUY MUST BE APPROVED IN ACCORDANCE WITH 160.050 SUBCHAPTER Q, RING BOUY MSHALL HAVE TYPE II RETRO-REFLECTIVE TAPE AND BE MARKED. DID NOT HAVE VESSEL
NAME OR RETRO-REFLECTIVE TAPE ON IT.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 February 2021
Resolved
VESSEL MUST CARRY UP TO DATE CHARTS AND PUBLICATIONS. MI OBSERVED CHARTS WERE NOT UP TO DATE AND LIGHT LIST WAS OUT OF DATE.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 February 2021
Resolved
LIFE FLOAT SHALL BE STOWED IN A WAY THAT PERMITS MANUAL RELEASE FROM ITS SECURING ARRANGEMENTS. MI OBSERVED THE LINE ATTACHED TO THE FLOAT FREE WEAK LINK WAS THREADED THROUGH LINE HOLDER WOULD NOT FIT THROUGH ASSEMBLY TO RELEASE LIFE FLOAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2019
Resolved
An adult life jacket must be provided for reach person carried on board a vessel. 02 Kapok lifejackets were condemned. The vessel is restricted to the carriage of 16 passengers until 02 Adult Type I pfd's are placed in service onboard.
46 CFR 180.71(a)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 December 2018
Resolved
Each vessel that operates on the high seas must have on board a FCC Type accepted category 1, 406MHz EPIRB installed to automatically float free and activate. Hydrostatic release for EPIRB expired. Must install valid hydrostatic release for float free arrangement. Vessel restricted to voyages no greater than 3nm from shore.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 December 2018
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Stern life float two wooden oars were rotted, split, and not in serviceable condition. Oars must be replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 December 2018
Resolved
46CFR 171.124(b) - Each hatch cover must have a securing device. Securing cable for lazarette hatch was severed, requiring replacement.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 December 2018
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication. Vessel Coast Pilot out of date, requiring updated version.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 December 2018
Resolved
The operator of each self-propelled vessel of 12meters or more in length shall carry on board and maintain for ready reference a copy of the Inland Navigational Rules. Vessel carried outdated version of the navigational rules publication. Required to replace with current copy.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 December 2018
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved IAW 46CFR 164.018. Ring life buoy on starboard side missing all required retrorelective material.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 31 October 2017
Resolved
Replace battery in EPRIB. Vessel must not operate more than 3NM from land. 46CFR185.728.
Fire Fighting › Means of Escape › Stairways
Issued 31 October 2017
Resolved
Install a ladder for the emergency escape in the forward compartment. 46CFR177.500
Engineering › Fuel Oil Service System › Filter
Issued 20 August 2017
Resolved
Prove proper operation of propulsion following repairs.
Engineering › Bilge Water Management System › Manifold
Issued 24 October 2016
Resolved
Mark bilge manifold indicating direction of operation. 46 CFR 182.510
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 October 2016
Resolved
Mark fuel shutoff valve indicating direction of operation. 46 CFR 185.608
Operations/Management › Equipment Service/Testing › EPIRB
Issued 24 October 2016
Resolved
Provide EPIRB NOAA registration. 46 CFR 185.728
Lifesaving › Lifefloat › Painter
Issued 24 October 2016
Resolved
Attach painter around the body of the lifefloat. 46 CFR 180.137
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 24 October 2016
Resolved
Provide 2 hand red flares. 46 CFR 180.68
Construction/Loadline › Hull › Hull Plating
Issued 1 October 2015
Resolved
Vessel must undergo a drydock examination. Drydock examination expired.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 August 2014
Resolved
Replace expired battery for LF water light. Restricted to day time operations.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 August 2014
Resolved
Replace expired battery for water light. Restricted to day time operations.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 August 2014
Resolved
Install missing o-ring on water light.
Lifesaving › Hand Flares › Quantity
Issued 27 August 2014
Resolved
Provide adequate amount of hand flares in accordance with COI. Restricted operations to Lake, Bay, & Sounds.
Fire Fighting › Fire Bucket › Quantity
Issued 27 August 2014
Resolved
Provide 01 fire bucket.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 August 2014
Resolved
Provide proof of proper operation for bilge alarm panel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 January 2012
Resolved
Provide proof of missing first aid kit items: ammonia inhalants, burn dressing, forceps, iodine swabs, and waterproof adhesive compress IAW 46CFR160.041-4(b).
Navigation › Piloting/Steering › Marine Charts
Issued 31 January 2012
Resolved
Provide proof of updated charts for route.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 January 2012
Resolved
Provide proof of crew training log to include drills that were conducted on 31Jan2012.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 31 January 2012
Resolved
Provide proof of lifesaving inspection log.
Construction/Loadline › Penetrations › Gasket
Issued 31 January 2012
Resolved
Renew gasket on escape hatch on bow.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 January 2012
Resolved
Tighten hardware on railing.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 31 January 2012
Resolved
Provide proof of chain locker deck cover.
Construction/Loadline › Hull › Side Shell
Issued 31 January 2012
Resolved
Enact repairs on fiberglass gunwale aft of the cabin.
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 January 2012
Resolved
Preserve or renew deteriorating on port and STBD side on four beams forward from aft bulkhead in engine room. 46 CFR 176.610
Construction/Loadline › Hull › Stringer
Issued 5 January 2012
Resolved
Arrest and treat furring on upper clamp areas where clamp meets deck support beams on port and starboard side forward from aft bulkhead in engine room. 46 CFR 176.610
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 January 2012
Resolved
Provide new exhaust hose at transom. 46 CFR182.425
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 January 2012
Resolved
Provide missing double clamp for exhaust. 46 CFR 182.410 (d)(1)
Electrical › Electric Supply System (service) › Cable
Issued 14 December 2010
Resolved
Renew identified 5' run of solid strand cable with marine grade or boat cable.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 14 December 2010
Resolved
Prove proper operation of stbd emergency fuel shutoff valve.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 14 December 2010
Resolved
Provide proof of 12 year hydrostatic testing IAW NFPA for pre-engineered fixed fire extinguishing system.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 14 December 2010
Resolved
Re-attach and tighten STBD battery bank cables.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 14 December 2010
Resolved
Prove proper operation of emergency steering gear.
Lifesaving › Lifefloat › Float-free Link
Issued 14 December 2010
Resolved
Renew life float weak-link mounting surface and attach paddles to the float.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 December 2010
Resolved
Conduct underway drills and tests with USCG Marine Inspector present.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 December 2010
Resolved
Conduct operational test of bilge pump system with a USCG Marine Inspector present.
Lifesaving › Hand Flares › Not on Board
Issued 15 September 2009
Resolved
Provide two additional red hand flares IAW 46 CFR 180.68.
Fire Fighting › Fire Bucket › Quantity
Issued 15 September 2009
Resolved
Provide two additional fire buckets IAW 46 CFR 181.610.
Lifesaving › Lifefloat › Float-free Link
Issued 15 September 2009
Resolved
Remove "S" hook between weak link and painter.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 September 2009
Resolved
Replace grab line on STBD life ring.
Lifesaving › Lifefloat › Lifeline
Issued 15 September 2009
Resolved
Tether 10 person life float to the 12 person life float so it is protected by the weak link.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 September 2009
Resolved
Repair/ Replace loose and fractured hand rain stanchion bases.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 September 2009
Resolved
Provide crew to operate vessel for drills and operational tests.
Construction/Loadline › Hull › Hull Plating
Issued 29 April 2009
Resolved
Prior to carrying passengers for hire complete required hull exam.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 31 January 2008
Resolved
Replace 2 adult and 3 child lifejacket lights in accordance with 46 CFR 180.75.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 31 January 2008
Resolved
Prove proper operation of engine room fixed gas extinguishing system.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 31 January 2008
Resolved
Provide proof of MIS submission for drug and alcohol program.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 January 2008
Resolved
Update medical kit onboard in accordance with 162
Engineering › Bilge Water Management System › Piping
Issued 22 March 2007
Resolved
Repair leaks on piping for hand bilge pump in amidships bilge space.
Engineering › Steering Gear System › Hydraulic Hose
Issued 22 March 2007
Resolved
Repair leak in hydraulic lines from pilot house leading to amidships bilge space on the starboard side.
Engineering › Bilge Water Management System › Pump
Issued 22 March 2007
Resolved
Properly secure electric bilge pump in engine room compartment aft.
Construction/Loadline › Hull › Keel
Issued 22 March 2007
Resolved
Properly repair cracked/ damaged glass forward and aft of the rudder post on the hull and in the lazarette.
Construction/Loadline › Hull › Keel
Issued 22 March 2007
Resolved
Submit repair proposal for cracked/ damaged glass forward and aft of the rudder post on the hull and in the lazarette.
Communications › Radio Communications › VHF Radiotelephone
Issued 30 March 2006
Resolved
Provide proof of renewal for Marine Radio operators licence.
Communications › Radio Communications › EPIRB
Issued 30 March 2006
Resolved
Provide proof of battery replacement for EPIRB. Vessel is restricted to within 3 miles of shore
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 March 2006
Resolved
Replace 3 adult type 1 lifejackets, Vessel is restricted to carry 15 passengers 2 crew for a total of 17.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 30 March 2006
Resolved
Replace both 30 X 30 mesh flame screens for both Port and Starboard fuel oil tank vents.
Electrical › Electric Supply System (service) › Cable
Issued 30 March 2006
Resolved
Properly support wires in Engine room and lifejacket stowage area In accordance with 46 CFR 183.340 (4)
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 March 2006
Resolved
Properly treat areas of Wood "Furring" in engine room portside aft corner and in overhead first beam aft of fwd engineroom bulkhead.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 March 2006
Resolved
Prove proper operation of all navigation lights.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 March 2006
Resolved
Properly label fwd emergency escape hatch In accordance with 46 CFR 185.606.
Electrical › Electric Supply System (service) › Cable
Issued 30 March 2006
Resolved
Properly deanend wires under pilothouse console.
Lifesaving › Lifeboat Equipment › Oar
Issued 30 March 2006
Resolved
Properly label lifefloat oars.
Engineering › Bilge Water Management System › Interface Detector
Issued 30 March 2006
Resolved
Show proof of operation for lazarette bilge high level alarm
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 April 2005
Resolved
Provide proof of annual drug and alcohol program IAW 46CFR part 16
Engineering › Steering Gear System › Follow-up Assembly
Issued 19 April 2005
Resolved
Provide secondary means of steering IAW 46CFR182.30-5.
Stability › Weathertight Integrity › General
Issued 19 April 2005
Resolved
Renew cracked port side head window.
Stability › Weathertight Integrity › General
Issued 19 April 2005
Resolved
Renew cracked starboard side bridge sliding door window.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2005
Resolved
Prove proper operation of Anchor Light.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 April 2005
Resolved
Replace two adult type 1 PFD's.
Lifesaving › Lifefloat › Float Free
Issued 19 April 2005
Resolved
Make life floats float free in way of line wrapped under painter bracket.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 3 March 2005
Resolved
Service fixed fire extinguishing system and all required onboard portable fire extinguishers.
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 March 2005
Resolved
Provide proper cover for battery box and secure in way of engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2005
Resolved
Cap dead end wires in way of forepeak accommodation space starboard bulkhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2005
Resolved
Cap dead end wires on electric bilge pump in way of engine room.
Engineering › Bilge Water Management System › Piping
Issued 3 March 2005
Resolved
Renew broken PVC bilge suction line and strainer in way of second void aft.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2005
Resolved
Remove 3-way yellow extension cord tied into breaker box in way of the engine room.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 March 2005
Resolved
Renew cracked and loose deck rail stanchion mounts and attachment clamps.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2005
Resolved
Cap dead end wires in way of house aft exterior bulkhead.
Stability › Weathertight Integrity › General
Issued 3 March 2005
Resolved
Renew cracked port side head window.
Stability › Weathertight Integrity › General
Issued 3 March 2005
Resolved
Renew cracked starboard side bridge sliding door window.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 3 March 2005
Resolved
Provide proof of current Safety Radio Telephone Certificate.
Fire Fighting › Ventilation Systems
Issued 6 March 2004
Resolved
Provide proper ventilation covers for engineroom vents that will contain the fixed fire extinguishing system in the event of discharge.
Electrical
Issued 6 March 2004
Resolved
Remove portable battery charger in engineroom or submit plans for approval to install a properly wired approved charger.
Fire Fighting
Issued 6 March 2004
Resolved
Provide approvd portable fire extinguisher brackets for all portable extinguishers on board.
Construction/Loadline › Structures › End Bulkhead
Issued 6 March 2004
Resolved
Make engineroom bulkhead vapor tight. LEGACY COMPONENT DESC: Transverse Bulkhead
Engineering › Fuel Oil Service System
Issued 6 March 2004
Resolved
Submit plans for approval to to provide approved thru-bulkhead fitting for main engine fuel hose supply and return.
Navigation › Piloting/Steering
Issued 6 March 2004
Resolved
Provide on board the following: Updated charts, local notice to mariners, CG light lists and coast Pilot.
Stability › Watertight Integrity
Issued 6 March 2004
Resolved
Make Collision bulkhead watertight.
Lifesaving › Lifebuoys
Issued 6 March 2004
Resolved
Rig and Store lifefloats in accordance with 46 CFR 180.137
Lifesaving
Issued 6 March 2004
Resolved
Replace expired battery in lifefloat light.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 March 2004
Resolved
Replace spring type battery in lifefloat with applicable screw post type battery.
Lifesaving › Lifebuoys
Issued 6 March 2004
Resolved
Replace lifering buoy float light. (housing color faded to almost white in color)
Communications › Radio Communications › EPIRB
Issued 6 March 2004
Resolved
Provide proof of updated NOAA registeration for EPIRB and proof of EPIRB battery expiration date. LEGACY COMPONENT DESC: EPIRB
Stability
Issued 6 March 2004
Resolved
Provide and post copy of stability letter.
Documentation › Logs/Records
Issued 6 March 2004
Resolved
Provide proof of following: Lifesaving inspection log, Drill & Training log, EPIRB log, Senior Deckhand letter.
Documentation › Certificates/Documents
Issued 6 March 2004
Resolved
Provide proof of Drug and Alcohol testing.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 March 2004
Resolved
Provide and post emergency broadcast plackard.
Navigation › Piloting/Steering
Issued 6 March 2004
Resolved
Submit plans for approval to provide light shrouds that meet navagation lighting requirements as specified in Navagation Rules International and Inland LEGACY COMPONENT DESC: Inland Navigation Rules
Engineering › Fuel Oil Service System › Hose
Issued 6 March 2004
Resolved
Provide approved fuel hose with properfittings as required by 46 CFR 182.720. Fuel hose must also meet SAE J 1942 standards for fuel hose. LEGACY COMPONENT DESC: Hose
Engineering › Fuel Oil Service System › Hose
Issued 6 March 2004
Resolved
Provide proof that fuel hose in way of fuel tank to aft engineroom bulkhead fitting meets 46 CFR 182.720 & SAE J 1942 standards. LEGACY COMPONENT DESC: Hose
Documentation › Manuals/Policy Documentation
Issued 20 February 2003
Resolved
Update CG Lightlist and Coast Pilot navigation publications. LEGACY COMPONENT DESC: Navigation publications
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 February 2003
Resolved
Install new hydrostatic release.
Lifesaving › Hand Flares
Issued 8 January 2002
Resolved
Replace expired orange smoke pyrotechnics.
Lifesaving › Liferaft Equipment › Paddle
Issued 8 January 2002
Resolved
Replace two missing paddles for 12-person lifefloat.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 8 January 2002
Resolved
Prove proper operation of single sideband radio.
Lifesaving
Issued 15 February 2000
Resolved
REGISTER EPIRB UNDER CURRENT OWNERS INFORMATION.
Lifesaving
Issued 15 February 2000
Resolved
REPLACE EPIRB BATTERY. VESSEL IS LIMITED TO 3 MILES FROM SHORE UNTIL BATTERY IS REPLACED AND EPIRB IS SATISFACTORILY TESTED. - DOCUMENT IN VESSEL DECK LOG.
Engineering
Issued 29 November 1999
Resolved
PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE, LOSS OF PROPULSION SUFFERED BY VESSEL MUST BE SATISFACTORILY REPAIRED AND VERIFIED BY A MARINE INSPECTOR.
Accommodation/Occupational Safety
Issued 12 January 1996
Resolved
PROVIDE PLANS FOR NEW MARINE SANITATION SYSTEM.
Accommodation/Occupational Safety
Issued 12 January 1996
Resolved
REPAIR FRP INBOARD OF RUB RAIL ON STARBOARD AFT BULWARK AND PORT SIDE, MIDSHIP, BULWARK.
Electrical
Issued 12 January 1996
Resolved
PROPERLY TERMINATE WIRING UNDER OPERATOR CONSOLE.
Electrical
Issued 12 January 1996
Resolved
PROVIDE PROPER COVER FOR LIGHT FIXTURE IN FORWARD CABIN, PORT SIDE.
Electrical
Issued 12 January 1996
Resolved
REMOVE OR PROPERLY CONNECT DECK WASH PUMP TO SOURCE OF POWER.
Electrical
Issued 12 January 1996
Resolved
REMOVE OR PROPERLY CONNECT FISH TANK PUMPS TO POWER SOURCE.
Electrical
Issued 12 January 1996
Resolved
PROPERLY TERMINATE WIRING IN ENGINE ROOM.
Engineering
Issued 28 April 1995
Resolved
INSTALL FLAME BOWL ON RACOR FILTER
Lifesaving
Issued 28 April 1995
Resolved
REPAIR/REPLACE STRAPS ON RING BUOY.
Accommodation/Occupational Safety
Issued 24 April 1995
Resolved
REPAIR BROKEN GLASS IN THE FOLLOWING LOCATIONS:_x001C_ A) PILOT HOUSE, FORWARD PORTSIDE_x001C_ B) ACCOMMODATION SPACE, AFT DOOR
Construction/Loadline
Issued 24 April 1995
Resolved
RENEW GASKET ON WATERTIGHT SCUTTLE AT STEEERING COMPARTMENT, MAIN DECK (OR CLEAN GASKET AND RIM, AND PROVE WATERTIGHTNESS)
Construction/Loadline
Issued 24 April 1995
Resolved
TREAT FURRING (FUNGUS GROWTH) ON OVERHEAD IN STEERING COMPARTMENT
Electrical
Issued 24 April 1995
Resolved
SECURE LOOSE WIRING RUNS WITH PROPER TIES IN VARIOUS LOCATIONS THROUGHOUT THE VESSEL
Engineering
Issued 1 August 1993
Resolved
TROUBLE SHOOT CAUSE OF OVERHEATING (MAKE NECESSARY REPAIRS) AND CONDUCT U/WTEST OF MDE.
Engineering
Issued 23 March 1993
Resolved
PROVIDE PROTECTIVE HAND CUPS FOR REMOTE FUEL SHUT OFF VALVE REACH RODS.
Lifesaving
Issued 11 December 1992
Resolved
PROPERLY STENCIL PFD STOWAGE AND EMERGENCY FUEL SHUT OFF VALVES.
Documentation
Issued 11 December 1992
Resolved
PROVIDE RANDOM DRUG TESTING PROGRAM.
Electrical
Issued 11 December 1992
Resolved
REPAIR VESSELS RUNNING LIGHTS -VSL IS RESTRICTED TO DAYLIGHT OPERATIONS.
Construction/Loadline
Issued 17 March 1992
Resolved
MAKE AFT ENGINE ROOM BULKHEAD WATER AND VAPOR TIGHT BY SEALING HOLES IN THEUPPER OUTBOARD CORNERS.
Engineering
Issued 17 March 1992
Resolved
PROVIDE BELT GUARD FOR FWD END OF MAIN ENGINE.
Navigation
Issued 17 March 1992
Resolved
PROVIDE A COMPASS DIVIATION TABLE.
Unknown
Issued 22 March 1991
Resolved
SUBMIT OPERATION TEST FORM FOR IN-WATER TESTING OF MAIN ENGINE AND_x001C_ ELECTRONIC NAV GAR.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.