Records from 2016 to 2025. Most recent: inspection, 17 July 2025.
Inspection history · 24
17 July 2025
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8188446
7 July 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8180559
11 September 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7996274
28 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7913035
8 May 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7684148
31 January 2023
Administrative Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7671346
13 May 2022
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7547585
3 May 2022
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7439587
7 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7426991
11 May 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7194013
30 March 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7165885
22 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6981441
30 September 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6824689
9 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6680028
15 May 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6415092
31 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6347683
14 February 2017
COI Inspection · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6088331
10 January 2017
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6069080
10 January 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6116875
16 November 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6048259
6 November 2016
Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6037084
26 August 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5983680
8 March 2016
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5835808
9 February 2016
Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5811869
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 7 July 2025
Resolved
The provisions of this section shall apply only to United States flag vessels. Manned tank barges and tankships authorized to carry Grade A, B, C, or D liquids at any temperature, or Grade E liquids at elevated temperatures, shall be provided with a combustible gas indicator suitable for determining the presence of explosive concentrations of the cargo carried. An indicator which bears the label of Underwriters' Laboratories Inc., Factory Mutual Engineering Division, or other organizations acceptable to the Commandant will be accepted as meeting this requirement. 1) The portable combustible gas meter O2 sensor was faulty; and 2) The silver span gas cylinder P/N 600-0050-007 was past its use by date of Nov 2024, preventing determining the suitability of the meter to detect the presence of explosive concentrations of the recovered cargo. 1) Replace in-kind the faulty O2 sensor; and 2) replace in-kind the expired span gas cylinder to the satisfaction of the attending marine inspector.
46 CFR 35.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 19 September 2025
Resolution: Received email from vessel rep. Rich with photograph of the replacement gas monitor passing the calibration tests.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2025
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The Sea-Fire Marine Fire and Detection and Monitoring system overcurrent fuse protection is field installed blade type fuses. Replace with approved UL cartridge fuses of the same amperage to the satisfaction of the attending marine inspector.
46 CFR 183.380(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 5 September 2025
Resolution: Received email from vesel Captain with photograph with cartridge fuses installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The Pro Nautic 12.30 P and the Chargemaster 12/35-3 battery chargers are missing, the manufacturers required overcurrent fuse protection. Install fuses as described by 46 CFR 183.380(l) of the correct amperage in accordance with the battery charger manufacturer’s installation instructions to the satisfaction of the attending marine inspector.
46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 5 September 2025
Resolution: Received email from vesel Captain with photograph of this item resolved.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 July 2025
Resolved
A lighting fixture must be installed as follows: (1) Each fixture must comply with 183.200; 2) Each lighting fixture and lamp holder must be fixed. A fixture must not be supported by the screw shell of a lamp holder. Lighting fixture laying on top of generator switchboard with exposed electrical components and not fixed. 1) Mount lighting fixture in accordance with prescribed regulation; or 2) Decommission the lighting fixture all to the satisfaction of the marine inspector.
46 CFR 183.410(c)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 26 August 2025
Resolution: Received email from vesel Captain with photograph of this item resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2025
Resolved
S and L. Each major generator and motor shall be fitted with a nameplate of corrosion-resistant material marked with the following information as applicable: (1) Name of manufacturer. (2) Manufacturer's type and frame designation. (3) Output in KW of watts or horsepower
rating. (4) Kind of rating (continuous, intermittent, etc.). (5) Revolutions per minute at rated
load. (6) Amperes at rated load. (7) Voltage. (8) Frequency if applicable. (9) Number of phases, if applicable. (10) Type of winding (for direct-current motors). Port generator unit nameplate information is not legible. Make the nameplate legible to the satisfaction of the attending marine inspector.
46 CFR 183.10-5(a) Old “T”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 26 August 2025
Resolution: Received email from vesel Captain with photograph of this item resolved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Crew pulls the Sea-Fire Marine Fire and Detection and Monitoring system over current fuse protection with needle nose pliers when vessel is unmanned to prevent a low power alarm and the batteries from losing their charge. Provide a means from isolating the battery power to the Sea-Fire Marine Fire and Detection and Monitoring system without requiring the crew to pull the fuses to the satisfaction of the attending marine inspector.
46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 5 September 2025
Resolution: Received email from vesel Captain with photograph toggle switch installed to disconnect the batteries from the Sea-Fire Marine Fire and Detection and Monitoring system.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 July 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The first aid kit had expired aspirin, iodine swabs, and burn gel. Replace the expired contents in accordance with the above regulation.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 26 August 2025
Resolution: Received email from vesel Captain with purchase and installation receipt for this item to resolve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 July 2025
Resolved
Distribution panel boards shall be the safety type. Lounge feed distribution panel LP 104 circuit breaker opening covered with electrical tape. Seal opening with an approved circuit breaker blank cover to the satisfaction of the attending marine inspector.
46 CFR 183.10-10(d) Old “T”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 26 August 2025
Resolution: Received email from vesel Captain with photograph of this item resolved.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 July 2025
Resolved
The life raft manufacturer shall make operating instructions and information for the ship's training manual available in English to purchasers of inflatable life rafts approved by the Coast Guard, to enable vessel operators to meet SOLAS Chapter III, Regulation 35 (III/35). Posted placard displayed near installations of life rafts on vessels included a step for deploying an embarkation ladder. Provide objective evidence from the life raft manufacturer that the current placard with the embarkation ladder is the correct one for this model life raft and installation arrangement to the satisfaction of the attending marine inspector.
46 CFR 160.151-59(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 26 August 2025
Resolution: Received email from vessel Captain with statement from local life raft servicing facility that a sticker without a ladder graphic is not manufacturer by Viking.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Missing the emergency instructions posted at the operating station. Post the instructions at the operating station with the format prescribed by 46 CFR 185.510 to the satisfaction of the attending marine inspector.
46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2025
Resolved 5 September 2025
Resolution: Received email from vesel Captain with photograph of this item resolved.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 July 2025
No resolution recorded
All tank vessels are subject to the regulations contained in subchapter J (Electrical Engineering) of this chapter except as such regulations are modified by
the regulations in this subchapter for tank vessels. Vessel hazardous area is Zone 2. Rudder feedback unit and electrical cable/gland are not hazardous locations and explosive atmosphere certified. Provide rudder feedback unit and electrical cable/gland that are compliant with 46 CFR 111.105-3 and the parts of 46 CFR 111.105 applicable to the vessel, to the satisfaction of the attending Marine Inspector. To be resolved during the vessel's next dry dock in April of 2027.
46 CFR 31.35-1
Action required: 705 - Other - as specified
Due 30 April 2027
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2024
Resolved
This subpart applies to installations in hazardous locations as defined in Articles 500 through 505 of NFPA 70, Clause 6 of IEC 60092-502:1999 or Clause 8 of IEC 61892-7:2019. Vessel hazardous area is Zone 2. Provide documentation the rudder feedback electrical equipment and deck LED lighting equipment is not required to meet the above. If the equipment must meet the above, make compliant in accordance with 46 CFR 111.105-3 and the parts of 46 CFR 111.105 applicable to the vessel, to the satisfaction of the attending Marine Inspector.
46 CFR 111.105-1
Action required: 705 - Other - as specified
Resolved 7 July 2025
Resolution: The LED deck lighting electrical J-box, gland, and cable are now of the certified type for Zone 2. Rudder angle indicator will be issued an updated separate deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 June 2024
Resolved
Each generator must be protected by an over-current device set value not exceeding 115 percent of the generator full load rating. Both generators have an over-current device are 125A, which exceeds the 115 percent threshold. Replace the 125A over-current device for both generators, not to exceed the 115 percent threshold.
Due 30 July 2024
Resolved 7 July 2025
Resolution: Inspected the breaker and the vessel's one line diagram and it looks original to the vessel. Cleaared the deficiency due to it not being applicable to an Old "T" vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 June 2024
Resolved
Each steering gear feeder circuit must be protected by a circuit breaker that meets the requirements of §58.25-55 in sub-chapter F of this chapter. Each feeder circuit for steering must be protected by a circuit breaker on the switchboard that supplies it and must have an instantaneous trip set at a current of at least— (1) 300% and not more than 375% of the rated full-load current of one steering-gear motor for a direct-current motor; OR (2) 175% and not more than 200% of the locked-rotor current of one steering-gear motor for an alternating-current motor. Marine inspector was unable to verify that the circuit breaker on the switchboard that supplies it had an instantaneous trip. Prove that the circuit breaker on the switchboard has an instantaneous trip, or replace to the meet the
requirements of this regulation.
Due 17 July 2024
Resolved 7 July 2025
Resolution: Cleared deficiency due to it not being applicable to an Old "T" boat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 May 2024
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch (PSI) at the pump outlet. The pump outlet shall be fitted with a pressure gage. During operational test of fire pump, pressure gage at outlet reading observed was 47 psi. Achieve required 60 psi at pump outlet to the satisfaction of the attending Marine Inspector (MI).
46 CFR 181.10-1 (e)
(Old T-L)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2024
Resolution: Received video from vessel [name withheld] with the fire pump operating gauge reading 78psi; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 May 2024
Resolved
Where liquid level indicating gages are installed, they shall be of heat resistant materials, adequately protected from mechanical damage and provided at the tank connections with devices which will automatically close in the event of rupture of the gage or gage lines. Diesel fuel tanks liquid level indicating gages are plastic and the tank connection valves are manual gate valves. Install to the satisfaction of the attending MI liquid level indicating gages that are heat resistant and tank connections with devices which will automatically close in the event of rupture of the gauge or gauge lines.
46 CFR 182.20-22(c)(5)
Old T
Action required: 705 - Other - as specified
Resolved 7 July 2025
Resolution: Attended vessel and confirmed the installation of the glass liquid level gage and fail close valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2024
Resolved
Except as otherwise provided in this paragraph all unfired pressure vessels shall be Coast Guard approved and installed to the satisfaction of the Officer in Charge, Marine Inspection. The requirements for design, construction and original testing of such approved unfired pressure vessels are in applicable regulations in Subchapter F (Marine Engineering) of this chapter. Information concerning the applicable regulations may be obtained from the Officer in Charge, Marine Inspection. Unfired pressure vessel relief valve settings check is due. Installed relief valve has an unknown test/service date. Service/test relief valve. Also, the unfired pressure vessel is missing the pressure gauge. Install pressure gauge. Once complete schedule and test the unfired pressure vessel relief valve in the presence of the attending MI.
46 CFR 182.10-5(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 25 October 2024
Resolution: Attended vessel and inspected the new pressure relief valve and gauge; all sat. Witnessed satisfactory pressure relief valve testing; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 May 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. One adult life jacket not serviceable. Vessel is restricted to 19 persons total until life life jacket is replaced to the satisfaction of the attending MI.
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 15 July 2024
Resolution: Attended vessel and confirmed new life vest with whistle and light; all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 May 2024
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with
permanent type connectors. Spring clips or other temporary type clamps are not permitted. One battery in the stbd aft battery bank had wing type terminal connector. Replace with hex nut to the satisfaction of the attending MI.
46 CFR 183.05-20(c)
(Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 15 July 2024
Resolution: Attended vessel and inspected the battery in the stbd aft battery bank had wing type terminal connector removed and a nut installed; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 May 2024
Resolved
In addition to meeting the requirements of paragraphs (a) through (e) of this section, a vessel with a power driven main steering gear must be provided with the following: An independent rudder angle indicator at the operating station. Rudder angle indicator not reading the correct angle of rudder. Repair and prove proper operation to the satisfaction of the attending MI.
46 CFR 182.610(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 15 July 2024
Resolution: Attended vessel and observed the rudder indicator operation to center and calibrated to the proper angle readings; all sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 May 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] room emergency escape scuttle marking is not clearly visible. Mark this escape scuttle in such a manner so the marking is clearly visible to the satisfaction of the attending MI.
46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 15 July 2024
Resolution: Attended vessel and observed engine room emergency escape scuttle marking clearly visible; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 May 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The hot water heater and the head tank for the hot water system is not secured sufficiently creating a hazardous condition. Mount the lower section of the hot water heater and the head tank to the satisfaction of the attending MI.
46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 15 July 2024
Resolution: Attended vessel and inspected the metal straps securing the hot water heater and the head tank; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 May 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Port reduction gear pilothouse pressure gauge inoperable. Repair and prove proper operation tot he satisfaction of the attending MI.
46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 7 July 2025
Resolution: Attended vessel and observed the port reduction gear pilothouse gauge reading pressure.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 May 2023
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Vessel's life rafts were not arranged in a float free arrangement. Reconfigure stowage arrangement so that it is float free.
180.130(a)(1)
17C
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2023
Resolved 9 May 2023
Resolution: Vessel rep correctly installed the float-free arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2023
Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q. Grab line is brittle and is disintegrating on both life buoys. Provide operable grab lines for ring buoys.
46CFR180.70(b)(1)
16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 11 May 2023
Resolution: Vessel replaced deteriorated line with new line.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2022
No resolution recorded
Electrical equipment on a vessel must be installed and maintained to: (a)Provide services necessary for safety under normal and emergency conditions. 46 CFR183.01-15 Old T. Vessel has modified various electrical circuits. Submit current electrical configuration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022 — due date passed with no resolution recorded
Resolution: Vessel conducted electrical review of ship and submitted an Excel spreadsheet, created by a marine electrician, that outlines all electrical installations. Pending Plan Review.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2022
Resolved
Vessel must be provided with bilge pumps in accordance with Table 46 CFR 182.520(a). Vessel overboard valve for bilge pump stuck in open position.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 25 May 2022
Resolution: Bilge pump and valve handles tested and found satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 13 May 2022
Resolved
The construction and arrangement of berths and other furniture must allow free and unobstructed access to each berth. Remove all gear in front of rack/berthing. Remove all gear on the racks/berthing and store properly. Racks were used for storage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 25 May 2022
Resolution: All gear removed from on top of and in front of racks.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2022
Resolved
An independent modular smoke detecting unit must:(1) Meet UL 217 and be listed as a single station smoke detector. Prove proper operation of each smoke detector in conjunction with detector panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2022
Resolved 25 May 2022
Resolution: Tested smoke detectors in coordination with smoke detection panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2022
Resolved
Throttle controls for the bridge are not fasted to the control console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 25 May 2022
Resolution: Controls are re-fastened to console.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2022
Resolved
Conduct DAPI Audit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2022
Resolved 25 May 2022
Resolution: DAPI audit completed satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Both fire hoses had numerous pin hole leaks near the hydrant attachment point.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Two new fire hoses were installed with witness satisfactory test. Old fire hoses were destroyed in the presence of the marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 June 2020
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (2) a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. The bilge high water panel at the operating station is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Electrician was hired and repaired the bilge high water alarm panel. Marine inspector witness a satisfactory alarm operational test.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 22 June 2020
Resolved
No manned ship subject to this part may operate unless it carries on board a shipboard oil pollution emergency plan approved by the Coast Guard...if the Coast Guard determines that the plan meets the requirements of this section, the Coast Guard will issue an approval letter. The approval period for a plan expires 5 years after the approval date. The SOPEP onboard expired on 20JUN2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2020
Resolved 24 July 2020
Resolution: Vessel has an approved SOPEP until 6/20/2025.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2020
Resolved
By March 15 of the year following the collection of the data in paragraph (a) of this section...a consortium or other employer representative may submit data for a marine employer. MIS report was not onboard the vessel for review.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 23 June 2020
Resolution: Received copy of the NRC SENTRY consortium MIS report.
Lifesaving › Hand Flares › Quantity
Issued 22 May 2017
Resolved
Insufficient number of distress flares on board. Had 8 hand red distress flares and 3 hand orange smoke flares. Required 6 of each or 12 hand red distress flares as substitute.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2017
Resolved 22 May 2017
Resolution: Additional red hand flares were purchased
Fire Fighting › Fire Main › Pressure
Issued 22 May 2017
Resolved
Fire main pressure gauge inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 31 January 2018
Resolution: Witnessed satisfactory operational test of fire main pressure guage.
Engineering › Steering Gear System › Ram
Issued 10 January 2017
Resolved
Make permanent repairs to steering system and conduct operational test in the presence of marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2017
Resolution: Vessel replaced ram, conducted underway operational tests
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 16 November 2016
Resolved
Missing mechanical plugs for containment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 12 December 2016
Resolution: Installed mechanical plugs in all containment.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 16 November 2016
Resolved
Load Line certificate expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 12 December 2016
Resolution: Load line certificate renewed.
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 November 2016
Resolved
Prove proper operation of compass light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 12 December 2016
Resolution: Installed light and proved proper operations.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 6 November 2016
Resolved
Anchor chain broken and anchor not present.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2016
Resolved 7 November 2016
Resolution: replaced in kind
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 9 February 2016
Resolved
Provide fire dectection for all accomadation spaces.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: Fire dectection provided.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 February 2016
Resolved
Provide retroreflective tape on lifebuoys.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: Retroreflective tape provided.