MAURY USCG vessel records
← All vessels

HESTIA

Built
1976
Last inspected
9 June 2005
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 9 June 2005
…with no type recorded33
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1982–2005)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
MARSHALL ISLANDS
Maury page id
psix-48623

Documentation record

Tonnage as PSIX records it7132 - Convention (Subpart B), Gross Ton
8150 - Regulatory (Subpart C or D), Gross Ton
6574 - Convention (Subpart B), Net Ton
8150 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 72 inspections, each with its date, unit and type; 46 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 72

9 June 2005 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2390027
14 September 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2195811
28 April 1998 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1124232
1 December 1997 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1111387
12 November 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1119994
26 September 1997 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1414864
25 September 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 512825
23 September 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 534082
11 September 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1107938
23 April 1997 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1441208
4 April 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466459
5 March 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368105
28 January 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757688
27 January 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 140899
27 January 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 201051
1 August 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 445520
17 July 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1089684
16 July 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 531158
15 May 1996 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1398452
23 February 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1192881
15 February 1996 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1441035
19 May 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 195250
19 May 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757633
27 April 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1175858
1 April 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1367337
9 March 1995 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1357066
6 April 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1165844
4 March 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1356533
17 February 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 853977
10 March 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1149058
3 March 1993 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 835824
25 March 1992 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 954130
20 February 1991 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 921151
7 December 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 916118
15 October 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 914940
14 September 1990 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 922600
29 August 1990 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1227762
15 June 1990 Deficiency Check · Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1231457
11 June 1990 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907260
4 June 1990 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 901910
30 April 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1238271
28 March 1990 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 930811
25 March 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 932992
22 June 1989 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1200206
17 June 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 483031
2 May 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 896572
7 December 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 530361
25 August 1988 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1346777
27 July 1988 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1212060
5 July 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1208109
16 May 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1348531
15 April 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1036663
25 March 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1300210
4 February 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 536503
1 July 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 495909
12 May 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1330583
7 November 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 497470
29 June 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 444278
4 April 1986 COI Inspection · Credit Drydock
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 992117
6 March 1986 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 468271
5 February 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 993713
5 February 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 999934
15 January 1986 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 996201
3 January 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 988143
8 August 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 453254
8 August 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 513953
17 April 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1287928
4 February 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 476755
8 January 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 464269
13 November 1984 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1283860
25 July 1984 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 443037
29 January 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969425

Deficiency record · 46

Engineering
Issued 26 September 1997 Resolved
MAKE TEMPORARY REPAIRS OR BLANK OFF NUMBER 6 PORT TANKS THERMAL FLUID HEATER PIPING PRIOR TO OPERATIONS.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Engineering › Lubricating Oil Service System › Piping
Issued 26 September 1997 Resolved
CONDUCT HYDROSTATIC TESTING OF THERMAL FLUID HEATING PIPING AFTER REPAIRS HAVE BEEN COMPLETED.
Condition: Unknown
Due 26 October 1997
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering
Issued 26 September 1997 Resolved
CROP AND RENEW TO ORIGINAL NUMBER 6 PORT DECK THERMAL FLUID HEATER PIPING.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Engineering › Lubricating Oil Service System › Piping
Issued 26 September 1997 Resolved
CONDUCT SURVEY AND GUAGING OF ALL DECK THERMAL FLUID HEATING PIPING AND SUBMIT REPORT TO MSO SAN JUAN.
Condition: Unknown
Due 26 October 1997
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation
Issued 5 March 1997 Resolved
REPAINT STARBOARD SIDE LOADLINE MARKINGS.
Condition: Unknown
Due 5 April 1997
Resolved 7 April 1997
Deck/Cargo
Issued 5 March 1997 Resolved
INSTALL LAGGING ON VERTICAL EXHAUST MANIFOLD ON CENTER CARGO PUMP ENGINE.
Condition: Unknown
Due 5 April 1997
Resolved 7 April 1997
Construction/Loadline
Issued 5 March 1997 Resolved
REPAIR/REPLACE ALL HANDRAILS AND STANCHIONS AS NEEDED.
Condition: Unknown
Due 5 April 1997
Resolved 7 April 1997
Deck/Cargo
Issued 5 March 1997 Resolved
PROVE CERTIFICATION AND TESTING OF AIR RECIEVER RELIEF VALVES.
Condition: Unknown
Due 5 April 1997
Resolved 18 March 1997
Deck/Cargo
Issued 15 May 1996 Resolved
OPERATE THERMAL FLUID HEATER IN PRESENCE OF MARINE INSPECTOR. OPEN THERMALFLUID HEATER FOR INTERNAL VISUAL INSPECTION.
Condition: Unknown
Due 17 May 1996
Resolved 20 May 1996
Electrical
Issued 15 May 1996 Resolved
NEW CABLE INSTALLED IN OVERHEAD OF MACHINERY SPACE/PUMPROOM MUST BE PROPERLY SECURED TO EXISTING CABLEWAY WITH METAL TIES.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Deck/Cargo
Issued 15 May 1996 Resolved
MARK TWO PORTABLE HOSES ON DECK WITH DATE OF LATEST HYDROTEST AND SERVICE OF HOSE.
Condition: Unknown
Due 17 May 1996
Resolved 20 May 1996
Deck/Cargo
Issued 15 February 1996 Resolved
PORTION OF CARGO PIPING REPLACED WHILE BARGE WAS IN DRYDOCK. UNABLE TO COMPLETE HYDROSTATIC TEST AT THIS TIME. MUST COMPLETE HYDROSTATIC TEST TO SATISFACTION OF COGNIZANT [name withheld] CARGO AND BY 29FEB96.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Deck/Cargo
Issued 15 February 1996 Resolved
SEVERAL ON DECK CARGO PIPING HANGERS WASTED IN NEED OF REPLACEMENT. TO BE REPLACED TO THE SATISFACTION OF THE COGNIZANT [name withheld] CARGO AND BY 29FEB96.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Deck/Cargo
Issued 15 February 1996 Resolved
PORTIONS OF THE THERMO FLUID HEATER PIPING WERE REPLACED ON DECK. FLEXIBLEPIPE CLAMPS WERE "TEMPORARILY INSTALLED" TO SECURE PIPING IN PLACE. PERMANENT CLAMPS MUST BE INSTALLED TO THE SATISFACTION OF THE COGNIZANT [name withheld] AND BY 29FEB96.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Deck/Cargo
Issued 9 March 1995 Resolved
Replace flame screens on P/V valves to cargo tanks 4P, 5P, 6P prior to handling cargo.
Condition: Unknown
Due 9 March 1995
Resolved 20 March 1995
Deck/Cargo
Issued 9 March 1995 Resolved
Install covers for overhead lights in pumproom.
Condition: Unknown
Due 9 March 1995
Resolved 20 March 1995
Engineering
Issued 9 March 1995 Resolved
Properly label thermal fluid heater remote shutdown outside of pumproom.
Condition: Unknown
Due 23 March 1995
Resolved 28 April 1995
Deck/Cargo
Issued 9 March 1995 Resolved
Install protective lagging on center cargo pump expansion bellows.
Condition: Unknown
Due 23 March 1995
Resolved 28 April 1995
Electrical
Issued 9 March 1995 Resolved
Blank off gaps in pumproom port light panel.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Engineering
Issued 9 March 1995 Resolved
Have safety relief valves for thermal fluid heater bench tested in presenceof Coast Guard Marine Inspector.
Condition: Unknown
Due 15 March 1995
Resolved 20 March 1995
Lifesaving
Issued 4 March 1994 Resolved
Repaint or replace warning sign on forward house.
Condition: Unknown
Due 6 April 1994
Resolved 7 April 1994
Documentation
Issued 4 March 1994 Resolved
Provide a written text description of oil transfer systems in accordance with title 33 Code of Federal Regulations part 155.750.
Condition: Unknown
Due 6 April 1994
Resolved 7 April 1994
Electrical
Issued 4 March 1994 Resolved
Install globe over light fixture located in way of starboard prime mover storage area.
Condition: Unknown
Due 6 April 1994
Resolved 7 April 1994
Engineering
Issued 4 March 1994 Resolved
Hydrostatically test thermal fluid heater piping prior to use. This test must be witnessed by a Coast Guard Inspector.
Condition: Unknown
Due 6 April 1994
Resolved 7 April 1994
Electrical
Issued 4 March 1994 Resolved
Reseal rubber and fiberglass battery box liners.
Condition: Unknown
Due 6 April 1994
Resolved 7 April 1994
Deck/Cargo
Issued 4 March 1994 Resolved
Replace flame screens on pressure vacuum valves where they have been painted over. Do this prior to any cargo operations.
Condition: Unknown
Due 6 April 1994
Resolved 7 April 1994
Construction/Loadline
Issued 4 March 1994 Resolved
Reconnect or reroute sink discharge line in forward starboard rake end and eliminate water discharge into rake.
Condition: Unknown
Due 6 April 1994
Resolved 7 April 1994
Deck/Cargo
Issued 3 March 1993 Resolved
PRIOR TO NEXT DISCHARGE OF CARGO, DEMONSTRATE THE OPERATION OF THE CARGO PUMP EMERGENCY SHUTDOWN TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Construction/Loadline
Issued 29 August 1990 Resolved
EFFECT PERMENENT REPAIRS TO CRACK IN SIDE SHELL LOCATED AT THE TURN OF THE BILGE IN #1 STARBOARD CARGO TANK.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Construction/Loadline
Issued 29 August 1990 Resolved
NO CARGO OR BALLAST IS TO BE CARRIED IN TANKS 1 PORT,1 CENTER, OR 1 STARBOARDUNTIL SUCH TIME AS PERMENENT REPAIRS ARE MADE.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Construction/Loadline
Issued 11 June 1990 Resolved
MAKE PERM REPAIRS TO STBD SKEG INWAY OF EXSISTING TEMP REPAIR OUTBD UPPER END AND FRACTURE INWAY OF LOWER END OF DIA STIFFENER. ALL REPAIRS TO BE ACCOMPLISHED PRIOR TO THE CARRAGE OF CARGO AND PRIOR TO DEPARTURE SEAMS INSPECTION ZONE
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Construction/Loadline
Issued 4 June 1990 Resolved
MAKE PERMANENT REPAIRS TO SIDE PLATING IN WAY OF #8 CARGO TANK WHERE STAR- BOARD SKEG IS WELDED TO SIDESHELL PLATING. VESSEL CANNOT CARRY CARGO IN #8TANK UNTIL PINHOLE LEAK IS WELDED. RED-HAND USED AS TEMPORARY PATCH TO MAINTAIN WATERTIGHT INTEGRITY OF VESSEL.
Condition: Unknown
Due 4 June 1990
Resolved 4 June 1990
Lifesaving
Issued 28 March 1990 Resolved
PROVIDE PROPERLY INSTALLED C.G. APPROVED BUOYANT APPARATUS PRIOR TO MANNINGVESSEL WHILE UNDERWAY.
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Electrical
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF DIESEL GENERATOR LUBE OIL ALARM AND SHUTDOWN.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
PRIOR TO THE CARRIAGE OF A QUALIFIED PERSON ONBOARD, AND IN NO CASE LATER THAN THE COMPLIANCE DATE BELOW, PROVIDE A 5 MAN LIFEFLOAT.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
PROVIDE ONE ADULT LIFE PRESERVER.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Navigation
Issued 2 May 1989 Resolved
STRAIGHTEN STARBOARD RUNNING LIGHT PLATFORM.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 27 July 1988 Resolved
PROVIDE IN ACCORDANCE WITH ASME CODE SEXTION IX THE WELDING PROCEDURE SPECIFICATION, PROCEDURE QUALIFICATION RECORD, WELDER PERFORMANCE QUALIFICATION AND MATERIAL SPECIFICATIONS OF ALL NEW PIPING INSTALLATION TO PUGET SOUND OCMI.
Condition: Unknown
Due 27 July 1988
Resolved 27 July 1988
Construction/Loadline
Issued 25 March 1988 Resolved
INSTALL NEW GASKET IN PORT SIDE, PORT FWD AND STBD SIDE ENGINE HOUSE WTD'S.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Deck/Cargo
Issued 25 March 1988 Resolved
PROVE OPERATION OF CARGO PUMP RELIEF VALVE AT NEXT CARGO TRANSFER OPERATION
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Deck/Cargo
Issued 25 March 1988 Resolved
HYDRO DECK CARGO PIPING AT NEXT CARGO TRANSFER.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Deck/Cargo
Issued 25 March 1988 Resolved
REMOVE PIPE PATCHS, REPAIR AND HYDRO PIPING FOR THERMAL FLUID HTR.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Construction/Loadline
Issued 25 March 1988 Resolved
INSTALL NEW GASKETS IN VENTILATION COVERS ABOVE ENGINE HOUSE.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Accommodation/Occupational Safety
Issued 25 March 1988 Resolved
REMOVE VALVE AND BLANK OFF PIPE IN STBD FWD RAKE FOR M.S.D.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Unknown
Issued 25 March 1988 Resolved
RE ATTACH WIRE CLIPS FOR EMERGENCY TOW WIRE ON PORT SIDE.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Accommodation/Occupational Safety
Issued 25 March 1988 Resolved
RE ATTACH PORT BOW HAND RAIL.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988