Records from 1998 to 2006. Most recent: inspection, 21 February 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
21 February 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2589354
17 November 2004
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2242662
26 October 2004
COC-CVE Quarterly
Type not classified · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2227675
3 September 2004
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2179037
4 July 2004
ISPS II Exam
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2118001
4 June 2004
Administrative Inspection
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2088843
20 May 2004
Ballast Water Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2073107
11 May 2004
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2064844
27 April 2004
Certificate of Compliance
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2053957
17 December 2003
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1965510
26 September 2003
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1914041
26 September 2003
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1920715
7 June 2003
Security Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1812882
2 June 2003
Quarterly Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1807730
22 May 2003
Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1798835
22 January 2003
MARPOL Annex I Examination · Control Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1733734
26 July 2002
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1652267
17 June 2002
Control Verification · Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1632743
10 May 2002
Passenger/Freight Vessel Examination · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1623655
24 January 2002
Control Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1480433
14 September 2001
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1432562
7 September 2001
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 293347
25 June 2001
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1068890
11 June 2001
Quarterly Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1376631
22 February 2001
Deficiency Check · MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1395628
14 June 2000
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1426435
16 January 2000
MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1399270
18 October 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1123341
20 September 1999
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1451446
22 June 1999
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 430022
22 June 1999
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1460317
21 June 1999
Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 96779
12 June 1999
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 429491
12 June 1999
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1408325
19 May 1999
Quarterly Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1462756
4 December 1998
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1381458
11 November 1998
Type not recorded
No type recorded · Activities Europe · Activity 1364930
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 October 2004
Resolved
PROVE PROPER OPERATION OF THE OWS TO THE SATISFACTION OF THE IOPP CERTIFICATE ISSUING AUTHORITY (FLAG) AND AN ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN. PROVIDE OWS ENGINEERING CREW FAMILIARIZATION TRAINING IN THE PROPER USE OF THE OWS. SEE NARRATIVE FOR MORE DETAILS.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2004
Personnel › Training
Issued 27 April 2004
Resolved
Provide proof of necessary training & qualifications for Chief Mate, Chief Engineer, Second Engineer's and all persons assigned immediate responsibility for the safety of passengers in emergency situations for passenger ships including crowd management; passenger safety and hull integrity;
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2004
Resolution: Received fax certificates for officers from flag attesting to proper STCW 78/95 Reg. V/3 Training. Vessel released from PSC detention.
Operations/Management › Drills/Instruction
Issued 27 April 2004
Resolved
Conduct full inflatable liferaft drill in presence of U.S. Coast Guard personnel at next U.S. port upon receipt of training liferaft. LEGACY COMPONENT DESC: Launching/Recovery of Survival Craft
Action required: 15 - Rectify deficiencies by next port
Resolved 11 May 2004
Documentation › Markings/Placards
Issued 27 April 2004
Resolved
Provide Oil Pollution Placard in vessels official language and post in vicinity of OWS overboard valve. LEGACY COMPONENT DESC: Oil Discharge Placard
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 11 May 2004
Documentation › Safety/Response Plans/Programs
Issued 27 April 2004
Resolved
Update Fire Control plan to reflect portable fire extinguisher located in Technical Machinery Room to the satisfaction of Flag and/or Class. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 11 May 2004
Documentation › Manuals/Policy Documentation
Issued 7 June 2003
Resolved
Vessel Security Plan is not up to date in accordance with NVIC 04-02. Last approved in 1998. Vessel to update before next port call to Milwaukee on 21 June 03. LEGACY COMPONENT DESC: Vessel Action Plan (SIP)
Due 21 June 2003
Resolved 16 September 2003
Resolution: Security plan updated and approved by MSC,
Lifesaving › Lifeboat Equipment
Issued 18 June 2002
Resolved
One food package damaged from rough handling. Replaced from onboard spares. LEGACY COMPONENT DESC: Food Ration
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2002
Fire Fighting › International Shore Connection
Issued 17 June 2002
Resolved
International shore connection does not fit ship nor shore connections. Make new connection IAW SOLAS Chapter II-2, Regulation 19. To be completed by 17 July 2002. LEGACY COMPONENT DESC: Flange
Condition: Design Flaw
Due 17 July 2002
Resolved 19 June 2002
Resolution: Corrected per owner report.
Fire Fighting › Structural - A Class Divisions
Issued 24 January 2002
Resolved
Remove hold back latch on self closing fire screen door located at entrance to sprinkler room. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2002
Resolution: MSO Sault Ste. Marie, corrected and cleared this deficiency
Fire Fighting › Ventilation Systems
Issued 24 January 2002
Resolved
Provide inspection criteria for laundry dryer exhaust system, to include access points for ducting and inspection intervals to the satisfaction of class society. LEGACY COMPONENT DESC: Ducts
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2002
Resolved 17 June 2002
Resolution: MSO Sault Ste. Marie checked and cleared deficiency.
Documentation
Issued 16 January 2000
Resolved
PROVIDE BUNKERING PROCEDURES IAW 33 CFR 155.720 PRIOR TO BUNKERING IN US WATERS.
Condition: Unknown
Due 16 January 2000
Resolved 16 January 2000
Construction/Loadline
Issued 16 January 2000
Resolved
PROVIDE STANDARD DISCHARGE CONNECTION FOR OIL SLOPS IAW MARPOL ANEX 1/18.
Condition: Unknown
Due 16 January 2000
Resolved 16 January 2000
Navigation
Issued 16 January 2000
Resolved
PROVIDE MISSING SAN JUAN CHART PRIOR TO DEPARTURE
Condition: Unknown
Due 17 January 2000
Resolved 14 February 2000
Engineering
Issued 16 January 2000
Resolved
PROVIDE METHOD/PROCEDURE FOR TESTING OF 15 PPM OILY WATER SEPARATOR, THAT CONFIRMS OWS WILL STOP OVERBOARD DISCHARGE. PROVIDE CLASS SOCIETY REPORT STATING THAT 15 PPM OWS EQUIPMENT FUNCTIONS, AND PROCEDURE IS IN PLACE FOR THE FUTURE TESTING, PROVIDE REPORT TO NEAREST CG OFFICE.
Condition: Unknown
Due 16 January 2000
Resolved 16 January 2000
Navigation
Issued 12 June 1999
Resolved
All U.S. charts and pubs for area to be transitted to be corrected prior toentering U.S. waters.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Fire Fighting
Issued 12 June 1999
Resolved
Outfit all sprinkler zones IAW SOLAS regulations. Reissuance of MIAMS requirement of 19 May 99._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1999
Resolved 12 June 1999
Fire Fighting
Issued 19 May 1999
Resolved
Prior to 19JUN99, outift all sprinkler zones IAW SOLAS regulations.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Unknown
Issued 19 May 1999
Resolved
Prior to 19JUN99, prove proper operation of 15ppm alarm and/or recirculation valve.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Fire Fighting
Issued 4 December 1998
Resolved
Prior to return to U.S. port, provide fire proof life lines for fireman's outfits.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Unknown
Issued 4 December 1998
Resolved
Prior to return to U.S. port, complete all outstanding comments from Coast Guard Marine Safety Center plan review comments.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Fire Fighting
Issued 4 December 1998
Resolved
Prior to return to U.S. port, permanently seal lock holes in fire screen doors where locks have been removed.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Fire Fighting
Issued 4 December 1998
Resolved
Prior to return to U.S. port, post up to date, flag approved, fire control plans.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Fire Fighting
Issued 4 December 1998
Resolved
Prior to return to U.S. port, provide IMO placards for muster stations and sprinkler valves.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Fire Fighting
Issued 4 December 1998
Resolved
Prior to return to U.S. port, renew collapsed hose on portable dry chemicalextinguisher in engine room.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Fire Fighting
Issued 4 December 1998
Resolved
Prior to return to U.S. provide suitable drainage for sprinkler valves so water does not flood compartment.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Unknown
Issued 11 November 1998
Resolved
COMPLETE ALL REMAINING 130 ISSUED WORKLIST ITEMS PRIOR TO FIRST U.S. PORT. _x001C_ _x001C_ CG INSPECTOR -- SEE MINS CASE MI98036870 FOR WORKLIST ITEMS.
Condition: Unknown
Due 11 November 1998
Resolved 11 November 1998