Inspection history · 28
10 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 879937
17 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 24694
17 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 61202
12 March 1993
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 843323
20 July 1992
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 958585
11 June 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 955388
4 May 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1259700
25 April 1992
Damage Survey · Permit to Proceed
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445919
24 April 1992
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1259320
17 April 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 169430
7 April 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 136923
6 December 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 946376
16 August 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1253324
13 May 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1213374
15 March 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 996833
16 August 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232145
13 July 1990
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1231679
24 May 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1030571
16 May 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341083
12 July 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030879
22 January 1988
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1330871
3 August 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337015
20 July 1987
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1314151
20 July 1987
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1337836
18 June 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021695
4 June 1986
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1296145
25 July 1985
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 985178
18 June 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 982998
Construction/Loadline
Issued 4 May 1992
Resolved
Make permanent repairs to port bow, in way of main deck, side shell and internal framing where damaged from collision.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 24 April 1992
Resolved
MAKE PERMANENT REPAIRS TO BOW AT PORT SIDE INCLUDING SIDE SHELL, DECK PLATING AND DESTORTED INTERNAL STRUCTURAL MEMBERS. OWNER/OPERATOR MUST COMPLETE REPAIRS IN 60 DAYS OR BEFOR 24JUN92. WHILE IN OPERATION BARGE MUST BE TOWED AND MAY NOT BE PUSHED.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Electrical
Issued 13 May 1991
Resolved
PROVE OVERSPEED OF PORT GENERATOR.
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Electrical
Issued 13 May 1991
Resolved
RELABEL REMOTE SHUTDOWNS FOR GENERATOR AND VENT SHUTDOWN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Construction/Loadline
Issued 13 May 1991
Resolved
REPLACE MISSING OR DISTORTED CARGO HATCH COVER DOGS.
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Deck/Cargo
Issued 13 May 1991
Resolved
REMOUNT REMOTE WASHDOWN SWITCH BETWEEN CARGO HOLDS #2 AND #3.
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Electrical
Issued 13 May 1991
Resolved
PROVIDE BLANKS FOR HOLES IN L - Z CONTROL ROOM DISTRIBUTION PANEL.
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Electrical
Issued 13 May 1991
Resolved
REPLACE OIL GAUGE ON STARBOARD GENERATOR.
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Deck/Cargo
Issued 16 August 1990
Resolved
REPLACE ALL WASTED CARGO HOLD COAMING LONGITUDINALS ON CARGO HOLDS 1 - 8
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Deck/Cargo
Issued 13 July 1990
Resolved
PROVIDE TANK VENT CLOSURES FOR ALL TANK VENTS MISSING CLOSURES. COMPLETE THIS ITEM WITHIN 10 DAY OR WHEN VESSEL RETURNS TO TAMPA, FL, WHICH EVER OCCURES FIRST.
Condition: Unknown
Due 13 July 1990
Resolved 13 July 1990
Deck/Cargo
Issued 13 July 1990
Resolved
A CANVAS HOOD SECURED BY LINE SHALL BE TEMPORARILY INSTALLED OVER THE VENT OPENING DURING HEAVY WEATHER UNTIL PERMANENT CLOSURE ARE INSTALLED
Condition: Unknown
Due 13 July 1990
Resolved 13 July 1990
Engineering
Issued 16 May 1989
Resolved
FREE-UP FUEL OIL REACH ROD. MUST BE COMPLETED PRIOR TO DEPARTING THE PORT OF TAMPA.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Deck/Cargo
Issued 16 May 1989
Resolved
WELD HOLES AND PROVIDE PLUG FOR DRAIN IN F/O COMPARTMENT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
INSTALL GLOBE GUARDS AS NEEDED ON ALL LIGHTS IN MACHINE SPACES, ELECTRIC PANEL SPACE AND ON DECK.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Fire Fighting
Issued 16 May 1989
Resolved
MOUNT ALL FIRE EXTINGUISHERS. MUST BE COMPLETED PRIOR TO DEPARTING THE PORT OF TAMPA.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 16 May 1989
Resolved
INSTALL HEAT SHIELDS FOR RACOR FILTERS.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 16 May 1989
Resolved
RELAG POST GEN. PRIME MOVER EXHAUST.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
PROVE OPERATION OF MACHINE SPACE VENT AND GENERATORS REMOTE SHUTDOWN.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Construction/Loadline
Issued 16 May 1989
Resolved
RESTUD AND NUT MAIN DECK FLUSH DECK HATCHES/ACCESS OPENING.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
PROVE OPERATION OF STBD GEN. OVERSPEED.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
PERMANENTLY MOUNT FLOURESCENT LIGHTS IN MACHINERY SPACE.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
INSTALL MISSING CAPS FOR BATTERIES. MUST BE COMPLETED PRIOR TO DEPARTING PORT OF TAMPA.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Documentation
Issued 22 January 1988
Resolved
PROVIDE AN APPROVED COPY OF THE VESSEL'S STABILITY LETTER AND BOOKLET OR SUBMIT THE NECESSARY DATA TO G-MTH FOR APPROVAL OF A NEW STABILITY LETTER AND BOOKLET.
Condition: Unknown
Due 22 January 1988
Resolved 22 January 1988
Electrical
Issued 18 June 1987
Resolved
REMOVE TEMPORARY LIGHTING FIXTURES AND WIRING ON OVERHEAD PORTSIDE MACHINERY SPACE.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
CLEAN OIL FROM UNDER AND AROUND BOTH GENERATORS.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
PROVIDE COVER FOR MISSING ELECTRICAL BREAKER IN CONTROL ROOM. (OPEN SLOT)
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987
Resolved
REPLACE DOGS ON HATCH FOR THE STBD SKEG ROOM.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
PROVIDE METAL HOLDERS FOR OVERHEAD WIRING AS NEEDED.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987
Resolved
FREE UP OR REPLACE DOGS FOR ALL WATERTIGHT DOORS WERE NEEDED.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987
Resolved
PROVIDE HOLD DOWN BOLTS FOR VOID COVERS, SOME MISSING ON VARIOUS SCUTTLE COVERS LOCATED THROUGHOUT THE VESSEL.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Accommodation/Occupational Safety
Issued 18 June 1987
Resolved
REPAIR OR REPLACE ALL MISSING OR DEFECTIVE DECK RAILING.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Accommodation/Occupational Safety
Issued 18 June 1987
Resolved
REPLACE MISSING SAFETY CHAINS AS REQUIRED FOR DECK RAIL OPENINGS.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987
Resolved
REPAIR OR REPLACE DEFECTING CARGO HATCHING DOGS.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Accommodation/Occupational Safety
Issued 18 June 1987
Resolved
PROVIDE APPROVED ELECTRICAL MATTING FOR SWITCHBOARDS.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
REPLACE GLOBE AND LIGHT GUARD FOR THE LIGHT LOCATED IN THE PORT SKEG ROOM.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
MOUNT LIGHT SWITCH LOCATED IN PORT SKEG ROOM.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
REPAIR LOOSE WIRING IN THE STBD SKEG ROOM.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
PROVIDE A LIGHT GLOBE FOR LIGHT IN STBD SKEG ROOM.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
REPLACE ALL MISSING OR BROKEN LIGHT GLOBES AND GLOBE GUARDS LOCATED THROUGHOUT VESSEL, AS NECESSARY.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987
Resolved
REPAIR OR REPLACE ALL LOOSE OR DEFECTIVE ELECTRICAL BOXES AS NEEDED.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Accommodation/Occupational Safety
Issued 18 June 1987
Resolved
PROVE PROPER OPERATION OF THE FUEL TANK EMERGENCY SHUT-OFF VALVE (REMOTE)
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Accommodation/Occupational Safety
Issued 18 June 1987
Resolved
BOTH AIR RECEIVERS ARE TO BE INTERNALLY INSPECTED.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1985
Resolved
RENEW BROKEN OR MISSING STUDS FOR BALLAST TANK MANHOLE COVER.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Engineering
Issued 18 June 1985
Resolved
PRIOR TO USING SHIPS SERVICE AIR RECEIVERS PROVE OPERATION OF RELIEF VALVE.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Electrical
Issued 18 June 1985
Resolved
REMOVE JURY RIGGED ELECT. WIRING FOR LIGHTS, BATT.CHARGER AND EXT. CORD IN MACH SPACE.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Engineering
Issued 18 June 1985
Resolved
RENEW VALVE FOR DIESEL OIL VENT CONTAINMENT.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985