OCEAN LEXINGTON

OCEAN LEXINGTON is a 1976 mobile offshore drilling unit. The Coast Guard has recorded 91 inspections since 1982, most recently in January 2006, along with 226 deficiencies.

Records from 1982 to 2006. Most recent: inspection, 11 January 2006.

Built
1976
Last inspected
11 January 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8755821 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP 5998
Flag
MARSHALL ISLANDS
—
Maury page id
psix-48636

Inspections, by type

…with no type recorded44
Years with a record 25 calendar years (1982–2006)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it9521 - Convention (Subpart B), Gross Ton
2856 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAVERICK Offshore Supply Vessel · MISLE 446712 · 25 May 2001 · activity 58259

Inspection history · 91

11 January 2006 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2569425
30 March 2005 COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2322812
14 August 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2174410
29 January 2004 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1996358
28 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764300
5 February 2003 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1749239
8 January 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1727766
3 October 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1686511
28 August 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1667685
26 August 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1666811
22 February 2002 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1488553
20 September 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1073997
25 May 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 58259
19 May 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064022
28 March 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1062185
7 February 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462937
31 January 2001 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1484439
9 August 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 155918
11 February 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 32765
7 February 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1386710
16 May 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 28005
3 March 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404721
27 October 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 25828
27 October 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 138011
12 March 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368637
6 February 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773993
26 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781133
12 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120576
7 July 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777989
18 March 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368104
7 March 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097029
20 December 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093610
5 December 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877282
25 March 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411257
7 December 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 876964
10 April 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 7637
10 April 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 96526
3 April 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409286
25 January 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826999
26 September 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 643651
11 September 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 101778
19 April 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 53612
4 April 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434102
25 February 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1164090
25 August 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1158937
1 April 1993 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1403611
1 June 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 128253
15 May 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 957122
14 April 1992 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1254295
11 June 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001332
9 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239988
17 April 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219428
26 March 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 923695
13 August 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 902757
27 March 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899790
27 March 1990 Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915953
31 January 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922138
15 October 1989 Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040752
1 September 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893626
31 March 1989 COI Inspection · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 891676
19 May 1988 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1203559
5 November 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024955
18 August 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320708
3 August 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029550
17 June 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005668
22 March 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008172
16 July 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300374
3 June 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302753
29 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990329
7 March 1986 Damage Survey · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001569
8 October 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993997
17 September 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300894
29 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293759
8 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290636
30 March 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 980953
29 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285187
22 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285176
15 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285175
9 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280534
15 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280615
10 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278620
27 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281624
1 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277213
26 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969411
29 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965828
20 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279850
14 July 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272048
17 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274711
6 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276642
7 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966118
7 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969515

Deficiency record · 226

Electrical › Lighting (emergency)
Issued 5 February 2003 Resolved
Repair emergency lighting fixture for port and starboard pump room escape ladder. LEGACY COMPONENT DESC: Lighting Fixture
Due 5 April 2003
Resolved 20 March 2003
Stability › Watertight Integrity
Issued 5 February 2003 Resolved
Adjust water tight door for starboard elevator shaft and prove proper operations. LEGACY COMPONENT DESC: Water tight door
Due 5 March 2003
Resolved 5 March 2003
Resolution: repaired [name withheld].
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 February 2003 Resolved
Adjust ventilation intake for quarter ventilation intake on front of house.
Due 5 March 2003
Resolved 6 March 2003
Resolution: was corrected [name withheld].
Electrical › Electric Generation Source (service)
Issued 5 February 2003 Resolved
Relocate or remove A/C unit in Hazardous area by aviation fuel tank.
Due 5 March 2003
Resolved 6 March 2003
Resolution: Removed by welder
Lifesaving
Issued 7 February 2001 Resolved
Replace the six missing emergency breathing air cylinders in the lifeboats.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Documentation
Issued 7 February 2001 Resolved
Provide ABS documentation of completion of annual crane examination for theport (Seaking) crane.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Lifesaving
Issued 7 February 2001 Resolved
Provide documentation of ABS or third party witnessing of liferaft davit weight testing (both davits) since the davit falls were renewed in April, 2000.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Engineering
Issued 7 February 2001 Resolved
Provide documentation that all unfired pressure vessel (UPV) relief valves have been renewed or tested by an ASME coded servicing facility within the last 12 months. Includes relief valves on motion compensator/riser tensioner storage cylinders, rig air, ship's air and bulk storage(P-tanks)
Condition: Unknown
Due 7 February 2001
Resolved 7 February 2001
Engineering
Issued 7 February 2001 Resolved
Install proper flame screens (30 X 30 mesh, corrosion-resistent material) on the JP-5 helicopter fuel tank.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Construction/Loadline › Structures
Issued 31 January 2001 Resolved
RENEW CLOSURE DEVICE ON ENGINE ROOM DOORS LEADING TO WEATHER DECK LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2002
Resolved 22 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 31 January 2001 Resolved
PROPERLY STOW GEAR IN ELEVATOR ACCESS SPACE IN A MANNER TO PREVENT FOULING IN THE ELEVATOR CABLES.
Action required: 705 - Other - as specified
Due 1 March 2002
Resolved 22 February 2002
Electrical › Electric Generation Source (emergency)
Issued 31 January 2001 Resolved
RENEW FOG SIGNAL BATTERY, PROPERLY BLOCK OBSTRUCTION LIGHT BATTERY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2002
Resolved 22 February 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 31 January 2001 Resolved
PROVIDE ADEQUATE EMERGENCY LIGHTING COVERING THE ESCAPE LADDER FROM BOTH PUMP ROOMS WITH THE ELEVATOR STOPPED IN ANY POSITION. LADDERS IN ELEVATOR TRUNK AND ELEVATOR BLOCKED THE ONLY SOURCE OF E-LIGH. LABEL ESCAPE HATCH 'DO NOT BLOCK EMERGENCY EXIT'.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2002
Resolved 25 March 2002
Resolution: rcvd fax
Lifesaving
Issued 7 February 2000 Resolved
PROVE PROPER OPERATION OF PURGE ALARMS ON DRILLERS CONSOLE.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Construction/Loadline
Issued 7 February 2000 Resolved
RENEW GASKET IWO GALLEY VENT..
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Electrical
Issued 7 February 2000 Resolved
MAKE REPAIRS TO EXPLOSION PROOF LIGHTING IN MUD PIT ROOM.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Electrical
Issued 7 February 2000 Resolved
VERIFY CONDITION OF INCONDESENT LIGHT IWO MUD PIT ROOM CENTER FWD.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Lifesaving
Issued 7 February 2000 Resolved
PROVE PROPER OPERATION OF MUD PIT ROOM VENTILATION SHUT DOWN ALARM. MAKE REPAIRS TO PRESSURE SENCOR.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Accommodation/Occupational Safety
Issued 3 March 1999 Resolved
In both shower rooms replace / repair tile and medal trim.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Lifesaving
Issued 12 March 1998 Resolved
PLACE ADDITIONAL APPROVED ROCKET PROPELLED LINETHROWING APPLIANCE ON BOARD.
Condition: Unknown
Due 12 April 1998
Resolved 24 March 1998
Electrical
Issued 12 March 1998 Resolved
LABEL MOTOR CONTROLLERS THROUGHOUT MACHINERY SPACES.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Fire Fighting
Issued 12 March 1998 Resolved
MAKE REPAIRS TO FIXED, SEMIPORTABLE AND PORTABLE FIREFIGHTING SYSTEMS IN ACCORDANCE WITH FIREMASTER REPORT, DATED 11-13FEB98. PLACE AN ADDITIONAL B-V SEMIPORTABLE FIRE EXTINGUISHER ON THE HELIDECK.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Construction/Loadline
Issued 12 March 1998 Resolved
CROP AND RENEW WASTED LADDER SUPPORTS AT BOW EMBARKATION DECK.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
CORRECT ALL DEFICIENCIES NOTED ON AMERICAN BUREAU OF SHIPPING REPORT, DATEDMARCH 12, 1998.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
STRIP AND CLEAN LIFEBOAT NO. 1. CONDUCT LIFEBOAT WINCH INSPECTIONS. LOG EACH REQUIRED INSPECTION.
Condition: Unknown
Due 26 March 1998
Resolved 24 March 1998
Lifesaving
Issued 12 March 1998 Resolved
STENCIL LIFEBOAT NUMBER AND RELEASE LEVER AND REPLACE MISSING WHISTLE AND JACKKNIFE ON LIFEBOAT NO. 3. REPLACE MISSING WHISTLE AND RETROREFLECTIVE TAPE ON LIFEBOAT NO. 1.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Documentation
Issued 12 March 1998 Resolved
OBTAIN APPROVAL FOR REVISED FIRE CONTROL PLAN. PLACE APPROVED PLAN ON BOARD.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
CONDUCT LIFEBOAT RELEASE GEAR TEST UNDER A LOAD OF 1.1 TIMES THE TOTAL MASSOF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Unknown
Issued 12 March 1998 Resolved
REPLACE MUD PIT DOORS.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
CONDUCT 110% LOAD TEST OF EACH LIFERAFT DAVIT FALL.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Fire Fighting
Issued 12 March 1998 Resolved
REPLACE DRY-ROTTED SELF-CONTAINED BREATHING APPARATUS AIR LINES.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
REPLACE MISSING FISHING KIT, WHISTLE AND JACKKNIFE ON LIFEBOAT NO. 2. REPLACE CRACKED WINDOW. CROP AND RENEW WASTED SPAN SUPPORT BEAMS AND CONDUCT 110% LIFEBOAT DAVIT LOAD TEST FOLLOWING REPAIRS.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
IMPLEMENT PROCEDURE TO ACCOUNT FOR ALL PERSONNEL AT ALTERNATE ABANDONMENT STATIONS.
Condition: Unknown
Due 26 March 1998
Resolved 24 March 1998
Fire Fighting
Issued 12 March 1998 Resolved
CROP AND RENEW FIRE STATION NO. 14.
Condition: Unknown
Due 26 March 1998
Resolved 24 March 1998
Electrical
Issued 18 March 1997 Resolved
PROPERLY LINE OR REMOVE BATTERY BOX FOR COMMUNICATIONS SYSTEM.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 18 March 1997 Resolved
MAKE REPAIRS IN ACCORDANCE WITH AMERICAN BUREAU OF SHIPPING SURVEY REPORT, DATED MARCH 18, 1997.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Lifesaving
Issued 18 March 1997 Resolved
CONDUCT AND PROPERLY LOG LINE THROWING APPLIANCE TRAINING.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Fire Fighting
Issued 18 March 1997 Resolved
INSTALL DOOR KNOBS IN GALLEY CLASS A DOORS.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Engineering
Issued 18 March 1997 Resolved
REPLACE VALVE ON STARBOARD FUEL TRANSFER HOSE. PROPERLY LABEL ALL FUEL TRANSFER HOSES.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Lifesaving
Issued 18 March 1997 Resolved
ARREST CORROSION TO DAVITS FOR LIFEBOAT NO. 1 AND NO. 2.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Construction/Loadline
Issued 18 March 1997 Resolved
CROP AND RENEW WASTED RAILS, GRATES AND STRUCTURAL MEMBERS ASSOCIATED WITH ALL COLUMN EMBARKATION LADDERS.
Condition: Unknown
Due 18 March 1997
Resolved 18 March 1997
Lifesaving
Issued 25 March 1996 Resolved
REPAIR MALFUNCTIONING BELL ON ONE SCBA IN SCR ROOM.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Lifesaving
Issued 25 March 1996 Resolved
PROVIDE BREATHING AIR SYSTEM IN LIFEBOAT AS PER OPERATING MANUAL.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Documentation
Issued 25 March 1996 Resolved
PROVIDE FUEL OIL TRANSFER PROCEDURES IAW 33CFR155.720.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Lifesaving
Issued 25 March 1996 Resolved
PROVIDE COVERS OR WATER SPRAY SYSTEM FOR WINDOWS FACING DRILL FLOOR IN RADIO ROOM IAW SECTION 9.2.13 OF THE 1979 IMO MODU CODE.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Electrical
Issued 25 March 1996 Resolved
PROVE PROPER OPERATION OF PURGE LOSS ALARM FOR VIDEO CAMERA IN SHALE SHAKERHOUSE.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Electrical
Issued 25 March 1996 Resolved
PROVE PROPER OPERATION OF PURGE LOSS ALARM FOR TOP DRIVE T.V. MONITOR.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Fire Fighting
Issued 25 March 1996 Resolved
REMOVE EXTRA HOSE FITTINGS FROM HOSE STATIONS AS NEEDED.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Lifesaving
Issued 25 March 1996 Resolved
INSTALL HYDROSTATIC RELEASES ON ALL LIFERAFTS.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Lifesaving
Issued 25 March 1996 Resolved
PROVIDE SEA ANCHORS FOR LIFE BOATS.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Electrical
Issued 3 April 1995 Resolved
REMOVE INDICATOR ON DRILL FLOOR AD CONTROLLER CONSOLE OR INSTALL IN EXPLOSION-PROOF BOX.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995 Resolved
REPAIR EXPLOSION-PROOF PRESSURE SENDING UNIT COVER ON DRILL FLOOR APV CONSOLE (CURRENTLY REPAIRED WITH JB WELD).
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995 Resolved
REPAIR PNUEMATIC CYLINDER OPERATED LOUVER CLOSURE ON EMERGENCY GENERATOR RADIATOR INTAKE.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995 Resolved
TEST EACH BATTLE LANTERN THROUGHOUT RIG AND REPAIR OR REPLACE WEAK BATTERIES.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995 Resolved
INSTALL PROPER EXPLOSION-PROOF CABLE GLANDS (EYS OR BICC) ON SEVEN STATER BOXES AND/OR J-BOXES AREA OF DRILLER'S CONSOLE.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 3 April 1995 Resolved
REPAIR OR REPLACE VENTILATION COVERS ON VENTS ON FORWARD BULKHEAD OF QUARTERS (MAIN DECK) DUE TO WASTAGE, THREE ACROSS FRONT OF QUARTERS.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 3 April 1995 Resolved
REPAIR HELO DECK FOAM FIRE PUMP. NO HELICOPTER REFUELING OPERATIONS ARE TO BE CONDUCTED UNTIL FOAM PUMP IS REPAIRED AND EXAMINED BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995 Resolved
INSTALL BLANKS OVER EMPTY CIRCUIT BREAKERS IN HEAT TRACING PANEL P-205L.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Documentation
Issued 3 April 1995 Resolved
PROVIDE ABS SURVEY REPORTS TO MSO NEW ORLEANS, ATTENTION [name withheld].
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 3 April 1995 Resolved
PROVIDE SECOND QUICK RELEASE RING BUOY WITH LIGHT AND SMOKE.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 4 April 1994 Resolved
PROVE PROPER OPERATION OF THE DRILLER'S CONSOLE PRESSURE/PURGE ALARM.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Construction/Loadline
Issued 4 April 1994 Resolved
RENEW BOTH DOORS TO MUD PIT ROOM AND PROVE PROPER OPERATION OF SAME.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Accommodation/Occupational Safety
Issued 1 April 1993 Resolved
PROVIDE EVIDENCE OF TESTING OF THE PERSONNEL ELEVATORS, FOR THE PORT & STBDPUMP ROOMS, BY AN INDEPENDENT ORGANIZATION.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Construction/Loadline
Issued 1 April 1993 Resolved
MAKE VESSEL AVAILABLE FOR A UNDERWATER SURVEY TO BE WITNESSED BY CLASS SOCIETY (ABS).
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Unknown
Issued 1 April 1993 Resolved
PROVIDE REGULATED AIR OF LESS THAN 3 PSI TO PURGED SYSTEMS ON DRILL FLOOR AND INSTALL GAUGES WHICH CAN BE READ TO 3 PSI.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Electrical
Issued 1 April 1993 Resolved
PROPERLY RUN CABLES IN CELLAR DECK AND PROVIDE CABLE GUARD WHERE MISSING ONSTBD SIDE OF CELLAR DECK.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Fire Fighting
Issued 1 April 1993 Resolved
PROVIDE COPY OF SOTEC FIRE EQUIPMENT SERVICING REPORT TO ATTN. OF INSPECTION DEPARTMENT AT ABOVE ADDRESS.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Documentation
Issued 1 April 1993 Resolved
PROVIDE AN APPROVED FIRE CONTROL AND LIFESAVING PLAN ABOARD. PLAN TO BE APPROVED BY ABS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Documentation
Issued 1 April 1993 Resolved
PROVIDE AN APPROVED OPERATING MANUAL (VOL. I & III) ONBOARD. MANUAL SHALL BE APPROVED BY ABS.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Engineering
Issued 1 April 1993 Resolved
PROVIDE DOCUMENTATION THAT PRESSURE VESSEL INTERNALS AND RELIEF VALVES HAVEBEEN WITNESSED BY ABS. CONTACT INSPECTION DEPARTMENT AT MSO NEW ORLEANS PRIOR TO CONDUCTING THESE EXAMINATIONS AND TESTS._x001C_
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Documentation
Issued 17 April 1991 Resolved
SUBMIT FOR APPROVAL AN EMERGENCY EVACUATION PLAN IAW 33 CFR 146.140.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Documentation
Issued 17 April 1991 Resolved
PROVIDE ONBOARD AN APPROVED OPERATIONS MANUAL THAT MEETS THE REQUIREMENTS_x001C_ OF 46 CFR 109.121.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Lifesaving
Issued 17 April 1991 Resolved
PROVIDE ONBOARD DAVIT LAUNCHED LIFERAFTS TO REPLACE ALL THROWOVER LIFERAFTSWEIGHT TEST SAME IN PRESENCE OF USCG MARINE INSPECTOR OR PROVIDE ABS OR THIRD PARTY TEST REPORT._x001C_
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Unknown
Issued 27 March 1990 Resolved
INSTALL A CGB FITTING APPROVED FOR CL I DIV II LOCATIONS ON THE ROTARY SWITCH IN THE COMPENSATOR PANEL ON THE DRILL FLOOR.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Unknown
Issued 27 March 1990 Resolved
FIX THE VENT CLOSURE PLATES FROM THE STAIR WELL TO THE BALLEST CONTROL AND RAIDO ROOMS SO THAT IT CAN BE CLOSED FROM BOTH SIDES.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Unknown
Issued 27 March 1990 Resolved
REPAIR THE ADAIR MUD MONITOR LOSS OF PURGE ALARM.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Unknown
Issued 27 March 1990 Resolved
REPAIR THE KNOCKING IN THE LIFEBOAT ENGIN/TRANSMISSION.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Unknown
Issued 27 March 1990 Resolved
RENEW THE WINDOWS IN THE LIFEBOAT.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Unknown
Issued 27 March 1990 Resolved
RENEW THE EXTINGUISHER #41.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Unknown
Issued 15 October 1989 Resolved
PROVIDE A REPAIR PROPOSAL AND TIME FRAME TO CONNECT THE INSET AREAS ON THE TWO VERTICLE DIAGONALS OFF THE PORT AFT COLUMN. ONE AREA 8'X3'X4". THE INBOARD VD IS ESTIMATED AS 3'X3'X4".
Condition: Unknown
Due 15 October 1989
Resolved 15 October 1989
Unknown
Issued 15 October 1989 Resolved
PROVIDE A COPY OF THE BELT GUAGINGS AND COLUMN GUAGINGS IN THE WIND AND WATER AREAS.
Condition: Unknown
Due 15 October 1989
Resolved 15 October 1989
Unknown
Issued 15 October 1989 Resolved
LEAVING THE EAST CAMERON LOCATION PROVIE DIVERS AND ASSOCIATED EQUIPMENT TOCOMPLETE THE CREDIT HULL INSPECTION OF THE UNDERWATER BODY, SEA CHESTS AND SEA VALVES. SEA VALVE TO BE PULLED SHOULD BE OTHER THAN THOSE PULLED DURING THE LAST INSPECTION.
Condition: Unknown
Due 15 October 1989
Resolved 15 October 1989
Electrical
Issued 31 March 1989 Resolved
REPAIR H2S ALARM SYSTEM PRIOR TO DRILLING.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
RENEW TYPE "SO"CABLE IN MUD PIT ROOM ON LEVEL INDICATORS WITH APPROVED CABLE PRIOR TO COMMENCING.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
RENEW TYPE "SO" CABLE IN BALLAST CONTROL ROOM ON GAS DETECTOR PANEL WITH APPROVED CABLE.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
RENEW TYPE "SO" CABLE IN RADIO ROOM ON SSB WITH APPROVED CABLE.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Engineering
Issued 31 March 1989 Resolved
REPAIR LOW & HIGH OIL TEMP LIGHTS ON #1 GENERATORS.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Engineering
Issued 31 March 1989 Resolved
REPAIR LOW OIL TEMP LIGHT AND CRANKCASE SELECTOR BUTTON ON #2 GENERATOR.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Engineering
Issued 31 March 1989 Resolved
REPAIR LOW OIL TEMP AND CRANKCASE LIGHTS ON #3 GENERATOR.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Deck/Cargo
Issued 31 March 1989 Resolved
REPIAR/INSTALL DECK AND OVERHEAD ESCAPE DOOR INTERLOCKS ON PORT ELEVATOR.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Deck/Cargo
Issued 31 March 1989 Resolved
REPAIR/INSTALL DECK AND OVERHEAD ESCAPE DOOR INTERLOCKS ON STBD ELEVATOR.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
PROVIDE 89 BAGS OF WATER FOR #1 CAPSULE (ORDERED 3/29/89).
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
RENEW FLEX HOSE BETWEEN PUMP AND SPRINKLER #1 CAPSULE.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
PROVIDE SEVEN (7) QUARTS OF WATER FOR CAPSULE #2 (ORDERED 3/29/89).
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
PROVIDE ONE (1) BI FIRE EXTINGUISHER FOR #2 CAPSULE (ORDERED 3/29/89).
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
PROVIDE 200 BAGS OF WATER FOR THE FORTY TWO MAN LIFE BOAT.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
PROVIDE ONE (1) TWENTY (20) MAN INFLATABLE LIFERAFT INSTALLED TOTAL PERSON ALLOWED ON BOARD UNTIL INSTALLED IS SEVENTY SIX (76).
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Construction/Loadline
Issued 31 March 1989 Resolved
RENEW PLUG IN VENT OVER #2 COLUMN.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Construction/Loadline
Issued 31 March 1989 Resolved
NON SKID HELO DECK.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Unknown
Issued 31 March 1989 Resolved
REPAIR MUD PIT DOOR JAMS AND DOORS AS NEEDED.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Unknown
Issued 31 March 1989 Resolved
CORRECT CLOSURE DEVICES ON MUD PIT DOORS.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Unknown
Issued 31 March 1989 Resolved
REMOVE DOUBLERS ON MUD PIT BULKHEAD TO PUMPROOM INSERT 18" & 24" RADIUS CORNERS, FULL PENETRATION WELD.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
MAKE PERMINENT REPAIRS TO THE COVER ON LIFEBOAT #3.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 31 March 1989 Resolved
REMARK INTERIOR FIREMAINS STATIONS SO THEY CAN BETTER BE SEEN WHEN LOOKING DOWN THE PASSAGEWAYS.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 31 March 1989 Resolved
HYDRO SPARE AIR BOTTLE IN SCR FIREMANS OUTFIT.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 31 March 1989 Resolved
CLEAN FOG APPLICATOR INSERTS.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
REPLACE BATTERIES IN THE EPRIB'S IN #1 & #2 CAPSULES.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
REPLACE ANTENNA ON THE EPRIB IN #1 CAPSULE.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 31 March 1989 Resolved
PROVIDE FOAM ANALYSIS REPORT.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 31 March 1989 Resolved
SERVICE ALL FIXED SYSTEMS, SEMI PORTABLE AND PORTABLE FIRE EXTINGUSHERS.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
REPAIR GENERAL ALARM BELLS EXTERIOR STARB BOW, SACK ROOM, SHALE SHAKER, MUDPIT ROOM.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
STENCIL LEGEND "WHEN BELL RINGS GO TO YOUR STATION"FOR GENERAL ALARM BELL AT, SUB SEA CONTROL PANEL ENGINE ROOM FLASHING LIGHT AT COMPRESSORS. (PAINT SUB SEA BELL RED).
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 31 March 1989 Resolved
PROVIDE RELIEF VALVES FOR BOTH FIRE PUMPS SET AT 165 PSI.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Construction/Loadline
Issued 31 March 1989 Resolved
REPAIR DECK AT AIR TUGGER BY HELO PAD.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Construction/Loadline
Issued 31 March 1989 Resolved
PAINT ALL VERTICAL LIPS/ COAMINGS IN TRAFFIC PATHS A CONTRASTING COLOR.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Accommodation/Occupational Safety
Issued 31 March 1989 Resolved
REPAIR MUD PIT VENT ALARM PRIOR TO DRILLING.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
REPAIR STBD PUMP ROOM DOOR INTERLOCK.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Engineering
Issued 31 March 1989 Resolved
INSTALL STAINLESS STEEL BOWL HEAT SHIELDS ON BACOR FUEL FILTERS FOR EMD'S.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
REPAIR EMERGENCY LIGHTS IN PORT PUMPROOM.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Deck/Cargo
Issued 31 March 1989 Resolved
PROVIDE EXPLOSION PROOF OR PURGE CONSOLE FOR CAMERON CHOKE PANEL ON DRILL FLOOR PRIOR TO DRILLING.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Construction/Loadline
Issued 31 March 1989 Resolved
CLOSE UP ELECTRICAL AND OTHER THROUGH BULKHEAD PENETRATIONS IN MUD PIT ROOM PRIOR TO DRILLING.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Accommodation/Occupational Safety
Issued 19 May 1988 Resolved
PROVE PROPER OPERATION OF MUD PIT VENTILATION ALARM.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Lifesaving
Issued 19 May 1988 Resolved
OBTAIN COAST GUARD APPROVED LINE THROWING GUN/ROCKETS.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Accommodation/Occupational Safety
Issued 19 May 1988 Resolved
PROVIDE VENTILATION CLOSURES FOR EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Construction/Loadline
Issued 19 May 1988 Resolved
FIX WATER TIGHT DOOR #5 CAISSON, ELEVATOR SHAFT.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Fire Fighting
Issued 19 May 1988 Resolved
REPAIR FIRE STATION NOZZLE RETAINER RETURN SPRING (ALL NOZZLES).
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Deck/Cargo
Issued 22 March 1987 Resolved
MAKE PERMANENT REPAIRS TO THE SOFT PATCH ON 6" SALT WATER LINE LOCATED PORT PUMP ROOM. LINE RUNS FROM THE SALT WATER SERVICE PUMP.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Accommodation/Occupational Safety
Issued 22 March 1987 Resolved
REINSTALL HAND RAILING NEAR EMERGENCY EMBARKATION (ESCAPE) LADDER LOCATED STBD BOW AREA.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Lifesaving
Issued 22 March 1987 Resolved
REMOVE SUPPLY HOSE BLOCKING EMERGENCY EMBARKATION (ESCAPE) LADDER LOCATED PORT STERN AREA.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Accommodation/Occupational Safety
Issued 22 March 1987 Resolved
CLEAN OIL AND GREASE FROM EXHAUST VENTS ABOVE STOVES IN GALLEY.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Fire Fighting
Issued 22 March 1987 Resolved
MAKE PERMANENT REPAIR TO GENERATOR ROOM SUPPLY VENTILLATOR PORT SIDE FWD AND REINSTALL FIRE DAMPER.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Fire Fighting
Issued 22 March 1987 Resolved
SUBMIT COPY OF FOAM SAMPLE ANALYSIS REPORT TO OUR OFFICE
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Fire Fighting
Issued 22 March 1987 Resolved
REFILL LOW AIR BOTTLE ON SCUBA LOCATED IN RADIO ROOM. HAVE AIR BOTTLE HYDROTESTED ON SCUBA LOCATED SCR SPACE.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Construction/Loadline
Issued 22 March 1987 Resolved
INSTALL COVERS OVER ALL DECK SCUPPENS (DECK DRAINS) THROUGH OUT DECK AREAS.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Navigation
Issued 22 March 1987 Resolved
PROIDE NAVIGATION DAY SHAPES FOR TOWAGE AND ANCHORING IN ACCORDANCE WITH THE COLREGS.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Engineering
Issued 22 March 1987 Resolved
PROVIDE MISSING GUARD FOR EMERGENCY DIESEL DOG TANK SIGHT GLASS.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Accommodation/Occupational Safety
Issued 22 March 1987 Resolved
POVIDE OPERATIONAL RELIEF VALVE FOR FIRE BULK TANKS WHERE RELIEF VALVE FAILED TEST. (40 PSI)
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Construction/Loadline
Issued 22 March 1987 Resolved
REPLACE MISSING DOG ON DECK HATCH COVER, MAIN DECK, PORT BOW COLUMN, AND ONBALLAST TANK VENT PIPE LOCATED PORT SIDE NEAR FLARE BOOM.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Accommodation/Occupational Safety
Issued 22 March 1987 Resolved
PROVIDE OPERATIONAL RELIEF VALVE FOR THE 8 RISER TENSION VALVE WHICH FAILED THE OPERATIONAL TEST. (240 PSE)
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Electrical
Issued 22 March 1987 Resolved
PROVIDE INTRINSUALLY SAFE EYES FITTING FOR WIRE AT JUNCTION BOX IN THE OVERHEAD ABOVE THE HALIBURTON UNIT.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Construction/Loadline
Issued 22 March 1987 Resolved
CLEAN AND REPAINT LOAD LINE PLIMSOL MARKS ON VESSEL'S PORT AND STBD SIDES.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Accommodation/Occupational Safety
Issued 22 March 1987 Resolved
MAKE PERMANENT REPAIR TO HOT WATER LINE IN GENERATOR ROOM IN WAY OF SOFT PATCHER.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Lifesaving
Issued 22 March 1987 Resolved
BOTH CAPSULES AND LIFEBOAT TO BE OPERATED IN THE WATER.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Fire Fighting
Issued 22 March 1987 Resolved
HAVE ALL OUT OT DATE FIXED CO2 BOTTLES, SEMIPORTABLE AND PORTABLE FIRE EXTINGUISHERS HYDRO TESTED IN ACCORDANCE WITH ALKUDRA SERVICE COMPANY REPORT DATED 3/18/87
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Navigation
Issued 22 March 1987 Resolved
MAKE OPERABLE THE PORT NAVIGATION RUNNING LIGHT.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Fire Fighting
Issued 22 March 1987 Resolved
COMPLETE THE FOLLOWING ON STBD AFT PAINT LOCKER: (A) PROVIDE VENT CLOSURE DEVICE ON VENT; (B) PLUG HOLE IN AFT HULKHEAD OF LOCKER; (C) LABEL REMOTE CONTROL FOR FIXED CO2 SYSTEM.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Electrical
Issued 22 March 1987 Resolved
REPAIR ELEVATOR RECALL CONTROL ON STBD ELEVATOR.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Construction/Loadline
Issued 22 March 1987 Resolved
REPAIR FOLLOWING LIGHTS ON BALLAST CONTROL BOARD; STBD BALL NO. 9, STBD SWB PUMP NO. 1, PORT BALL NO. 2.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Lifesaving
Issued 22 March 1987 Resolved
STENCILE VESSEL'S NAME ON CAPSULE NO. 1. PROVIDE THE FOLLOWING FOR CAPSULENO. 1: MILK (CONDENSED 1LB/MAN), JACKNIFE
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Lifesaving
Issued 22 March 1987 Resolved
PROVIDE THE FOLLOWING FOR CAPSULE NO. 2: MILK (CONDENSED 1LB/MAN), JACKNIFE
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Lifesaving
Issued 22 March 1987 Resolved
INSTALL BREAK-AWAY LINKS ON ALL LIFERAFT CANISTER.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Construction/Loadline
Issued 22 March 1987 Resolved
ALL REQUIRED SAFETY DRILLS, TESTS, AND INSPECTIONS TO BE LOGGED IN ACCORDANCE WITH 46 CFR 109
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Fire Fighting
Issued 22 March 1987 Resolved
A HOT WORK PERMIT SYSTEM SHALL BE ESTABLISHED, USED, AND PERMITS MAINTAINED IN ACCORDANCE WITH 46 CFR 109.433 AND 109.573
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Accommodation/Occupational Safety
Issued 22 March 1987 Resolved
REPAIR VALVE HANDLES IN MUD PUMP ROOM (REPAIR/REPLACE ONLY THE BLACK HANDLE THAT HAS TWO HANDLE SPOKES BROKER)
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Electrical
Issued 22 March 1987 Resolved
CONDUCT MONTHLY TEST OF EMERGENCY GENERATOR FOR 2 HOURS UNDER LOAD IN ACCORDANCE WITH 46 CFR 109.211.
Condition: Unknown
Due 22 March 1987
Resolved 22 March 1987
Deck/Cargo
Issued 7 March 1986 Resolved
PROVIDE RELIEF VALVES ON TWO (2) HOT WATER HEATERS UL OR ASME APPROVED TO RELIEVE AT NOT MORE THAN 100 PSIG AND 210 F.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Construction/Loadline
Issued 7 March 1986 Resolved
REPLACE MISSING GASKET ON OUTSIDE WATER TIGHT DOOR ON CAISSON#1.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Fire Fighting
Issued 7 March 1986 Resolved
INSTALL RELIEF VALVES ON EACH FIRE PUMP IN ACCORDANCE WITH 46CFR.108.417 ORSUBMIT FOR APPROVAL THE EXISTING FIRE MAIN SYSTEM.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Accommodation/Occupational Safety
Issued 7 March 1986 Resolved
THE RIG'S RED FOX UNIT IS A CG, APPROVED SYSTEM.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Electrical
Issued 7 March 1986 Resolved
MAKE OPERABLE THE GENERAL ALARM LIGHT IN THE ENGINE ROOM.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Documentation
Issued 7 March 1986 Resolved
PROVIDE A COPY OF THE STABILITY LETTER ON BOARD THE RIG, THAT REFLECTS THE INCLINE TEST DATA COMPLETED IN FEBRUARY 1985.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Documentation
Issued 7 March 1986 Resolved
PROVIDE A COPY OF THE CG, APPROVAL LETTER THAT ACCOMPANY'S THE OPERATING MANUAL.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Navigation
Issued 7 March 1986 Resolved
REPLACE HOUSE HOLD BULBS WITH PROPER NAVIGATION BULBS IN THE PORT; STBD RUNNING LIGHTS AND STERN LIGHT.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Fire Fighting
Issued 7 March 1986 Resolved
POST UNDER GLASS THE CG, APPROVED FIRE CONTROL LIFESAVING PLAN AND PROVIDE EVIDENCE TO [name withheld] THAT THE RIG HAS AN APPROVED HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Lifesaving
Issued 7 March 1986 Resolved
THE TOTAL PERSONS ALLOWED ONBOARD IS 78 UNTIL THE REQUIRED NUMBER OF INFLATABLE LIFERAFTS REQUIRED BY THE COI ARE PROVIDED ONBOARD. (ONE 20 MAN RAFT IS ASHORE BEING. SERVICED. THE TOTAL PERSONS ALLOWED ONBOARD ONCE ALLLIFESAVING EQUIPMENT IS ONBOARD IS 85(IE 85 BUNKS ONBOARD RIG).
Condition: Unknown
Due 7 March 1986
Resolved 7 March 1986
Fire Fighting
Issued 9 March 1984 Resolved
SUBMIT A FIRE CONTROL PLAN TO THE COAST GUARD FOR REVIEW. 46 CFR 107.305
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Electrical
Issued 9 March 1984 Resolved
SUBMIT A HAZARDOUS LOCATION PLAN TO THE COAST GUARD FOR REVIEW. 46 CFR 111.05-05.
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Documentation
Issued 9 March 1984 Resolved
PROVIDE A CONSTRUCTION PORTFOLIO ON BOARD THE VESSEL. 46 CFR 107.305
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Construction/Loadline
Issued 9 March 1984 Resolved
(CONT. 8) PIECE NUMBER 148 AND FRAME 6. INCLUDE DETAILED DESCRIPTION OF THE DAMAGE WITH STILL PHOTOGRAPHS.
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Deck/Cargo
Issued 9 March 1984 Resolved
REPLACE OR MAKE PERMANENT REPAIRS TO THE TRAVELING BLOCK COMPENSATOR PRES- SURE VESSEL LOCATED ON THE FORWARD SIDE OF THE BLOCK. 46 CFR 54
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Construction/Loadline
Issued 9 March 1984 Resolved
SUBMIT A REPAIR PROPOSAL TO THE OFFICER IN CHARGE MARINE INSPECTION FOR THEDAMAGE TO THE NUMBER 1 PORT BALLAST TANK IN WAY OF THE ANCHOR BOLSTER,
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Lifesaving
Issued 9 March 1984 Resolved
WEIGHT TEST THE #2 CAPSULE WHEN INSTALLED ON BOARD TO REPLACE THE RENTAL UNIT PRESENTLY ON BOARD. THE TEST IS TO BE CONDUCTED IN THE PRESENCE OF
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Lifesaving
Issued 9 March 1984 Resolved
(CONT. 4) A COAST GUARD MARINE INSPECTOR. 46 CFR 107.239
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Lifesaving
Issued 9 March 1984 Resolved
CONDUCT AN INVENTORY OF THE #2 CAPSULE WHEN INSTALLED. INVENTORY TO BE CON-DUCTED N THE PRESENCE OF A COAST MARINE INSPECTOR. 46 CFR 107.231
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Electrical
Issued 9 March 1984 Resolved
PROVIDE GENERAL ALARM BELLS IN THE FOLLOWING CAISSONS: 1, 3, 4 AND 6. 46 CFR 113,25-9
Condition: Unknown
Due 9 April 1984
Resolved 9 March 1984
Lifesaving
Issued 10 January 1984 Resolved
REDUCE THE TOTAL PERSONS ALLOWED ON BOARD THE RIG FROM 86 TO 70. THIS MAN- NING REQUIREMENT IS EFFECTIVE IMMEDIATELY AND SHALL REMAIN IN EFFECT UNTIL
Condition: Unknown
Due 10 January 1984
Resolved 10 January 1984
Lifesaving
Issued 10 January 1984 Resolved
(CONTINUE FROM D1) THE 28 MAN CAPSULE THAT IS MISSING IS REPLACED 46 CFR 108.503
Condition: Unknown
Due 10 January 1984
Resolved 10 January 1984
Documentation
Issued 27 July 1983 Resolved
PROVIDE CONSTRUCTION PORTFOLIO ABOARD RIG AS PER 46 CFR 107.305(HH).
Condition: Unknown
Due 27 July 1983
Resolved 27 July 1983
Unknown
Issued 27 July 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL ZAPATA LEXTINGTON, DN571193.
Condition: Unknown
Due 27 July 1983
Resolved 27 July 1983
Documentation
Issued 27 July 1983 Resolved
PROVIDE APPROVED CLASSIFIED AREA PLAN ABOARD RIG AS PER 46 CFR 111.05-5.
Condition: Unknown
Due 27 July 1983
Resolved 27 July 1983
Documentation
Issued 27 July 1983 Resolved
REVISE VESSEL'S FIRE CONTROL PLAN TO INCLUDE EQUIPMENT ADDED.
Condition: Unknown
Due 27 July 1983
Resolved 27 July 1983
Unknown
Issued 26 May 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL ZAPATA LEXINGTON, DN571193
Condition: Unknown
Due 26 June 1983
Resolved 26 May 1983
Deck/Cargo
Issued 26 May 1983 Resolved
PROVIDE SUITABLE FLAME SCREEN FOR THE BOW FUEL OIL DAY TANK VENT OF CORRO- SION RESISTANT WIRE OF AT LEAST 30 X 30 MESH AS PER 46 CFR 56.50-70(H) AND
Condition: Unknown
Due 26 May 1983
Resolved 26 May 1983
Navigation
Issued 26 May 1983 Resolved
REMOUNT, CLEAN AND PAINT BACKGROUND OF PORT AND STARBOARD RUNNING LIGHTS ASPER 46 CFR 111.75-15(G).
Condition: Unknown
Due 26 May 1983
Resolved 26 May 1983
Deck/Cargo
Issued 26 May 1983 Resolved
(REQUIREMENT 1 CONTINUED) 56.50-75(B)3.
Condition: Unknown
Due 26 May 1983
Resolved 26 May 1983
Documentation
Issued 26 May 1983 Resolved
PROVIDE CONSTRUCTION PORTFOLIO ON BOARD THE RIG AS PER 46 CFR 107.305(HH).
Condition: Unknown
Due 26 August 1983
Resolved 26 May 1983
Documentation
Issued 26 May 1983 Resolved
PROVIDE APPROVED FIRE CONTROL PLAN ON BOARD THE RIG AS PER 46 CFR 107.305 (CV).
Condition: Unknown
Due 26 July 1983
Resolved 26 May 1983
Documentation
Issued 26 May 1983 Resolved
PROVIDE APPROVED HAZARDOUS LOCATION PLAN AS PER 46 CFR 111.05-5.
Condition: Unknown
Due 26 July 1983
Resolved 26 May 1983
Lifesaving
Issued 26 May 1983 Resolved
PROVIDE ONE (1) 1500 FOOT AUXILIARY LINE FOR LINE THROWING GUN AS PER 46 CFR 108.517.
Condition: Unknown
Due 26 May 1983
Resolved 26 May 1983
Navigation
Issued 26 May 1983 Resolved
PROVIDE ONE (1) BLACK BALL DAY SHAPE AS PER 33 CFR 87.
Condition: Unknown
Due 26 May 1983
Resolved 26 May 1983
Deck/Cargo
Issued 26 May 1983 Resolved
PROVIDE GUARD ON AIR TUGGER STARBOARD BOW AS PER 46 CFR 108.223.
Condition: Unknown
Due 26 May 1983
Resolved 26 May 1983
Navigation
Issued 26 May 1983 Resolved
CLEAN AND REPAIR ALL OBSTRUCTION LIGHTS AS PER 33 CFR 67.
Condition: Unknown
Due 26 May 1983
Resolved 26 May 1983
Unknown
Issued 6 April 1982 Resolved
PROVIDE SIGHT GLASS GUARDS FOR LUB OIL SERVICE TANK
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
REPAIR LINE IN STARBOARD PUMPROOM AUTOMATIC BILGE SYSTEM.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Electrical
Issued 7 March 1982 Resolved
PROV. & DEMO. OSPD (SPD LT'NG DEV.) & LOW LUBE OIL TRP. & AUD. ALMS FOR ON LUBE OIL HIGH CL'NG WAT. TEMP. FOR THE EMER. GEN. DIE. (46 CFR 112.40-1(A))
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
RENEW "SHUTDOWN" SOLENOID SWITCH ON EMERGENCY BOARD; IN THE MEAN TIME MAK- ING PROVISION FOR THE SAFE AND RELIABLE OPER. OF THE EMER. POWER SYSTEM.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Lifesaving
Issued 7 March 1982 Resolved
PROPERLY INSTALL HYDROSTATIC RELEASES FOR LIFERAFTS #1, #2, #3, & #4.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Lifesaving
Issued 7 March 1982 Resolved
INSTALL APPROVED LIGHTS ON 28 LIFEJACKETS AS REQUIRED BY 46 CFR 108.514.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
MAKE FOL. EQUIP. SUIT. FOR INST. IN CLASS. AREAS AS REQ. BY 46 CFR 111.80 OR NFPA 496 ON EQUIPMENT LIST.
Condition: Unknown
Due 6 April 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
PROVIDE A 10' LOW VELOCITY SPRAY APPLICATOR AT FIRE STATIONS #1 & #2 AS REQUIRED BY 46 CFR 108.425(D)(2).
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Documentation
Issued 7 March 1982 Resolved
PROVIDE AN APPROVED OPERATING MANUAL AS REQUIRED BY 46 CFR 109.121.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
PROVIDE BLUE AND AMBER LIGHTS FOR HELO DECK AS REQUIRED BY 46 CFR 108.241 (A)(2).
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Deck/Cargo
Issued 7 March 1982 Resolved
REPAIR FAULTY "DEADMAN" NOZZLE FOR HELO REFUELING SYSTEM.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
REPAIR ELEVATOR DOOR INTERLOCK SWITCHES.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
REPAINT DRAFT MARKS.
Condition: Unknown
Due 6 April 1982
Resolved 7 March 1982
Construction/Loadline
Issued 7 March 1982 Resolved
REPAINT LOADLINE.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Construction/Loadline
Issued 7 March 1982 Resolved
MAKE PERMANENT REPAIRS TO THE FOLLOWING DAMAGED AREAS DAMAGE WORKLIST.
Condition: Unknown
Due 6 April 1982
Resolved 7 March 1982
Unknown
Issued 7 March 1982 Resolved
REPLACE DETERIORIATED DOORS TO MUD PIT ROOM REMOVE HOLD BACKS INSURE AD- EQUATE SEAL WITH DOOR FRAME AT ALL EDGES.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Lifesaving
Issued 7 March 1982 Resolved
REPAIR TRANSFORMER FOR #1 CAPSULE WINCH.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Lifesaving
Issued 7 March 1982 Resolved
REPAIR FAULTY LIMIT SWITCHES #1 & #2 CAPSULES.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
CHARGE EMER. GENERATOR ROOM COUVER CONTROLER WITH HYDRAULIC OIL.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
PROVIDE RUBBER MATS IN FRONT OF MOTOR CONTROL CENTERS NUMBERS 2, 4 & 5.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
RENEW PRESSURE RELIEF VALVE ON A/R HOU 75-364.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
TEST PRESSURE RELIEF VALVE AND MAKE AVAILABLE FOR INTERNAL EXAM: A/R HOU 74-1141.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Unknown
Issued 7 March 1982 Resolved
MAKE THE FOLLOWING P-TANKS AVAILABLE FOR INTERNAL EXAM: NUMBERS 7952, 7951& 7956.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Unknown
Issued 7 March 1982 Resolved
REMOVE DEAD WIRING ON P-TANKS AND A BOP BATTERY CHARGER.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Unknown
Issued 7 March 1982 Resolved
PROVIDE CONTAINMENT AROUND OIL BARRELS STORED IN MUD PUMP ROOM.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Unknown
Issued 7 March 1982 Resolved
RESCURE BARGE ALARM AND WIRING IN PORT PUMP ROOM.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Fire Fighting
Issued 7 March 1982 Resolved
REACK FIREPUMP AND DRILL WATER PUMP IN STBD PUMP ROOM.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Unknown
Issued 7 March 1982 Resolved
REPAIR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS OR REPLACE - RISERENSIONER BOTTLE SEA 74-223 DUE TO SHELL DAMAGE.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Unknown
Issued 7 March 1982 Resolved
TEST & INST. REL. VAL. WHICH CAN BE VER AS MT'NG THE CRIT. OF 46 CFR 54.10 ON THE FOL. TENS. BOT.: PIT 272,256,252,251,274,277,276,268,273,270.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Unknown
Issued 7 March 1982 Resolved
MAKE RISER TENSIONER (VERTICAL BOTTLES AVAILABE FOR INTERNAL INSPECTION & TEST REQUIRED RELIEF VALVES ON EACH BOTTLE SEE ITEM BFOR RELIEF VALVE CRIT.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
REPAIR OIL LINE LEADING TO THE COVERNOR ON #2 SERVICE GENERATOR.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
AMEND OIL TRANSFER PROCEDURES TO INCORPORATE DATA REQUIRED BY 33 CFR 155. 750 & PORT IN ACCORDANCE WITH 33 CFR 155.740.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Electrical
Issued 7 March 1982 Resolved
RENEW SIGHT GLASS ON THE 40 WT. OIL DAY TANK.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982
Lifesaving
Issued 7 March 1982 Resolved
REPLACE AIR BOTTLES IN LIFE BOAT.
Condition: Unknown
Due 7 March 1982
Resolved 7 March 1982