Records from 1982 to 2023. Most recent: inspection, 26 October 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 55
26 October 2023
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7810216
24 April 2023
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7671862
12 May 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7448873
17 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7413902
4 October 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7326632
23 July 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7265228
29 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7185876
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108539
5 October 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7071767
21 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6689098
27 March 2019
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6650170
13 September 2018
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6540028
6 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6499307
17 July 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6483482
6 July 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6195562
16 June 2016
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5915851
9 October 2014
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5001525
10 May 2012
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4307542
24 August 2011
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4125174
26 June 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3248771
12 October 2007
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3078294
6 July 2007
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2991556
4 June 2007
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2951723
21 June 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2106254
19 June 2003
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1821669
4 September 2002
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1670844
26 June 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1637585
29 June 2001
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468660
23 June 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432348
20 July 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1101284
24 June 1999
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469588
20 August 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 796758
14 August 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797767
16 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450166
24 June 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466471
18 June 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411316
1 December 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428557
21 June 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402081
24 June 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435508
22 June 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358107
4 December 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384998
23 July 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260983
23 June 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391779
27 June 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233038
6 August 1990
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927762
28 July 1989
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198229
4 August 1988
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343822
28 April 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350612
31 August 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004084
12 September 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005826
27 August 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000797
4 September 1985
Credit Drydock · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295899
27 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975928
30 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965947
2 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969895
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 October 2023
Resolved
The strength of the float free link must be determined by the combined capacity of the group of life floats. Vessel had a 12 & 15 capacity life float. Float free link was rated only for 11-20 capacity.
46 CFR 180.37(e)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2023
Resolved 1 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 October 2023
Resolved
The name of the vessel must be marked or painted in clearly legible letters on all life floats and life float paddles. Both life floats and all 4 paddles did not have the vessel name.
46 CFR 185.604
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2023
Resolved 1 March 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2023
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern. Vessel was marked with New Orleans, LA on the stern. COD and COI states Chauvin, LA as the hailing port.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2023
Resolved 1 March 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 October 2023
Resolved
Vessel must comply with applicable requirements for EPIRB installations, including certificates to be issued by the FCC as set forth in 47 CFR part 809. Vessel did not have EPIRB registration sticker at the time of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2023
Resolved 1 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 October 2023
Resolved
At each initial and subsequent inspection for
certification the MI shall examine and test auxiliary machinery to determine that they are in proper operating condition and fit for the service that they are intended. Owner stated prior to CG arrival generator stopped working properly. MI's were unable test for proper operation. Generator is not used for any vital systems on board.
46 CFR 176.25-10 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2023
Resolved 1 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 October 2023
Resolved
At each initial and subsequent inspection for
certification the MI shall examine and test main propulsion machinery to determine that they are in proper operating condition and fit for the service that they are intended. Starboard main engine would not start after drills.
46 CFR 176.25-10 (Old T)
Action required: 10 - Deficiency Rectified
Resolved 26 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 October 2023
Resolved
At each initial and subsequent inspection for
certification the MI shall examine and test main propulsion machinery to determine that they are in proper operating condition and fit for the service that they are intended. While conducting a "Fire in the Engine Drill" the starboard main engine would not secure.
46 CFR 176.25-10
Action required: 10 - Deficiency Rectified
Resolved 26 October 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 October 2023
Resolved
Each officer employed on any vessel subject to this sub-chapter must have his or her license on-board and available for examination at all times when vessel is operating. The first Master did not have a license that met the tonnage requirement and the second Master to take charge did not have a current medical certificate.
46 CFR 15.401
Action required: 10 - Deficiency Rectified
Resolved 30 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2022
Resolved
Electrical equipment shall be in proper operating condition, and fit for the service for which they are intended. Starboard spot light was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2022
Resolved 17 June 2022
Resolution: Provided photographic evidence of properly installed search light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2022
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed or hazardous places such as gears, machinery, etc. Missing machinery guard on port engine.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2022
Resolved 2 June 2022
Resolution: Installed proper machinery guard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 May 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel did not have any portable battery lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2022
Resolved 13 May 2022
Resolution: Vessel acquired new portable lights, and provided photograpgic evidence.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 May 2022
Resolved
A vessel must carry adequate and up-to-date charts. Vessel's charts are outdated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2022
Resolved 26 May 2022
Resolution: Provided photographic evidence of new and updated paper chart.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2022
Resolved
Each life jacket must be marked with Type I retro reflective material.
05 life jackets had worn or missing retro reflective material.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2022
Resolved 2 June 2022
Resolution: Installed new PFD's to replace older one.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2022
Resolved
Each ring buoy must be marked with Type II retroreflective material. Ring buoy had worn retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2022
Resolved 13 May 2022
Resolution: Vessel provided photographic evidence of new retro reflective tape on ring buoy.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 October 2021
Resolved
Master had expired credentials.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 4 November 2021
Resolved 4 November 2021
Resolution: Received video graphic evidence of discrepancy being corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 October 2021
Resolved
#1 MPDE was leaking water from water pump tell tail hole.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 4 November 2021
Resolution: Received video graphic evidence of discrepancy being corrected.
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 4 October 2021
Resolved
Compass deviation card was expired
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 4 November 2021
Resolution: Received video graphic evidence of discrepancy being corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2021
Resolved
Vessel was due for Drydock on 31 Mar 21. Vessel rep called MSU Houma and self-reported that they had been operating past that date, without drydocking. Vessel shall not operate until a successful drydock has been completed in the presence of the attending marine inspector. 46 CFR 176.600 (1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2021
Resolved 23 July 2021
Resolution: DD completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2018
Resolved
Life ring waterlight batteries are required to be replaced prior to their expiration. All waterlights on board including those on the throwable life rings and life floats had batteries which were expired. Must replace waterlight batteries with approved make and model.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2018
Resolved 13 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 August 2018
Resolved
Automatic bildge pumps are required to have an indicator light at the operators station to alert the operator when energized. Bildge pump in the engine room was not equipped with an indicator light. An indicator light must be installed at the operators station to comply with regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2018
Resolved 13 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 August 2018
Resolved
A positive shut off is required to be installed in line on bilge pipes which pierce the skin of the vessel. The bilge pump in the engine room was not equipped with a valve. A positive shut off must be installed to comply with this regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2018
Resolved 13 September 2018
Construction/Loadline › Penetrations › Weld
Issued 16 June 2016
Resolved
Cracked welds were identified on the Port and Starboard exhaust pipes leading to the lazarette, specifically where the exhaust pipes are welded to the aft bulkhead of the engine room. Welds need to be gouged out and rewelded.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 23 June 2016
Construction/Loadline › Hull › Side Shell
Issued 9 October 2014
Resolved
Plug hole in side shell plating on port side of machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Plugged hole.
Lifesaving › Lifebuoys › Serviceable
Issued 9 October 2014
Resolved
Replace ringbuoy due to wasted plug.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Ringbuoy replaced.
Lifesaving › Lifefloat › Float-free Link
Issued 9 October 2014
Resolved
Replace float-free link on lifefloat with one of appropriate size.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Float free link replaced.
Fire Fighting › Fire Bucket › Quantity
Issued 9 October 2014
Resolved
Provide three (03) fire buckets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Provided fire buckets.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 October 2014
Resolved
Place wire splices and dead end cables inside junction boxes.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Corrected wiring issues.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 October 2014
Resolved
Replace masthead light with a light that provides proper characteristics (225 degrees).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Replace light.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 October 2014
Resolved
Update EAP phone numbers.
Action required: 705 - Other - as specified
Due 9 November 2014
Resolved 10 October 2014
Resolution: Updated EAP phone numbers.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 October 2014
Resolved
Provide proof of Marine Radio operator permit.
Action required: 705 - Other - as specified
Due 9 November 2014
Resolved 14 November 2014
Resolution: Provided proof of attending course to obatain Marine Radio Operator''s Permit.
Documentation › Certificates/Documents › Stability Letter
Issued 10 May 2012
Resolved
Vessel does not have a valid stability letter meeting AAWPP requirements.
Due 4 June 2012
Resolved 2 June 2012
Resolution: Vessel owner chose to reduce passengers to meet AAWPP requirements. MSU Houma will issue stability letter addendum.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 August 2011
Resolved
Alcohol test strips expired.
Due 1 October 2011
Resolved 5 September 2011
Resolution: Replaced test strips.
Fire Fighting › Fire Bucket › Stenciling
Issued 24 August 2011
Resolved
Fire buckets not properly labeled
Condition: Improper/Lack of Maintenance
Due 1 October 2011
Resolved 5 September 2011
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 24 August 2011
Resolved
Engine room vent covers will not close.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2011
Resolved 5 September 2011
Resolution: Cleaned paint off vents
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 August 2011
Resolved
Engine room bilge alarm not working
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2011
Resolved 5 September 2011
Resolution: Cleaned float switch in engine room.
Lifesaving › Lifefloat › Markings
Issued 26 June 2008
Resolved
The maximum personnel capacity was not marked on the lifefloat.
Action required: 705 - Other - as specified
Resolved 26 June 2008
Resolution: Corrected on the spot.
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 June 2007
Resolved
A hydraulic line from the pilot house to the aft steering was leaking fluid.
Due 30 June 2007
Resolved 14 June 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2007
Resolved
Not under command lighting was not installed and the stern light was not operable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2007
Communications › Audible Communications › Horn/Whistle
Issued 4 June 2007
Resolved
The ship's whistle was not operable and no other sound producing device was present.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 June 2007
Resolved
The vessel was recently purchased and the new COD was not onboard.
Due 30 June 2007
Resolved 14 June 2007
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 4 June 2007
Resolved
A waste management plan was not posted.
Due 30 June 2007
Resolved 14 June 2007
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 4 June 2007
Resolved
Employee Assistance information was not posted.
Due 30 June 2007
Resolved 14 June 2007
Documentation › Certificates/Documents › Stability Letter
Issued 4 June 2007
Resolved
A stability letter was not onboard.
Action required: 705 - Other - as specified
Resolved 6 July 2007
Resolution: Received sistership documentation
Communications › Radio Communications › VHF Radiotelephone
Issued 2 July 2003
Resolved
Provide proof of operable VHF-FM radio.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2003
Resolved 2 July 2003
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 2 July 2003
Resolved
Provide new FCC safety radio certificate.
Action required: 705 - Other - as specified
Due 2 August 2003
Resolved 2 July 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 July 2003
Resolved
Make repairs to stern light.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2003
Resolved 2 July 2003
Stability › Incline Test
Issued 26 June 2002
Resolved
SIMPLIFIED STABILITY TEST NEVER COMPLETED.
Action required: 705 - Other - as specified
Due 30 July 2002
Resolved 4 September 2002
Resolution: VESSEL APPEALED REQUIRED STABILITY TEST TO THE OCMI OF MORGAN CITY, LOUISIANA. UPON REVIEW OF VESSEL CHARACTERISTICS AND VESSE''S SAME LAKES, BAYS AND SOUNDS ROUTE DURING THE LAST 20 YEARS THIS VESSEL IS HEREBY EXEMPTED FROM CARRYING A STABILITY LETTER.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 26 June 2002
Resolved
IMPROPER FLAME SCREEN INSTALLED ON FUEL OIL TANK VENT.
Due 26 June 2002
Resolved 26 June 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 June 2002
Resolved
FLEX HOSES CHAFFING ON ENGINE MOUNTS. NO CHAFFING GEAR INSTALLED. LEGACY COMPONENT DESC: FLEX HOSES
Due 26 June 2002
Resolved 26 June 2002
Construction/Loadline
Issued 24 June 1999
Resolved
INSTALL HIGH LEVEL BILGE ALARMS IAW 46 CFR 182.530 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, PRIOR TO 24 JULY 1999 IN THE RUDDER ROOM AND THE ENGINE ROOM.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Construction/Loadline
Issued 16 June 1998
Resolved
REPAIR FOREPEAK BILGE SUCTION TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO SAILING.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Engineering
Issued 16 June 1998
Resolved
INSTALL MAIN ENGINE DIESEL SHUTDOWNS AT OPERATING STATION TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Documentation
Issued 23 June 1992
Resolved
PROVIDE CURRENT FCC SAFETY CERTIFICATE ON BOARD. VESSEL IS RESTRICTED TO SERVICE WITHIN 1000' OF LAND.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Construction/Loadline
Issued 27 August 1986
Resolved
MAKE PERMANENT REPAIRS, AS ORIGINAL, TO THE DAMAGE LOCATED ON PORT AFTER RUB RAIL NEAR TRANSOM AND WELD PINHOLE LOCATED ON PAD-EYE-TO-HULL CONNECTION, PORT QUARTER AFT.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986