Registered dimensions (L × B × D)77.5 ft × 26.7 ft × 8.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNICHOLS BROS. BOAT BLDGS · FREELAND, WA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
29 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 29
24 March 2026
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8295197
4 March 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8311781
23 May 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8156093
27 March 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8104725
6 January 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8059067
1 April 2024
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7888056
7 March 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7875802
5 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7875243
22 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7868467
16 August 2023
Deficiency Check · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7770181
11 May 2023
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7690693
9 March 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7644472
25 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7437925
22 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412563
2 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7404465
11 March 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7148181
1 August 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7023255
22 June 2020
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6984196
18 March 2020
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6926374
25 October 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6842126
20 September 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6816754
9 September 2019
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6807906
18 April 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6665773
1 February 2019
Construction Oversight · Inclining Experiment · Plan Review (Other than "T")
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6618765
7 March 2018
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6367968
27 February 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6361947
8 March 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6100675
11 March 2016
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5830263
24 February 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5823027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2026
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI observed cracks on both propellers.
46 CFR 182.05-1
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2026
Resolution: Propellers satisfactorily repaired and reinstalled.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 24 March 2026
Resolved
Each opening in a watertight bulkhead must have a means to close it watertight. MI observed several drilled holes in the watertight bulkhead in the access to the Engine Room.
46 CFR 177.13-1
46 CFR 117.111
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2026
Resolution: Holes filled with bolts.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 March 2026
No resolution recorded
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. MI observed life float in unserviceable condition. Vessel's max passenger count is reduced by 22, the capacity of the life float, until a replacement is brought into service on board the vessel.
46 CFR 122.700(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2026
Resolved
Table 1 to 118.500(b) indicates the minimum required number and type of extinguisher for each space listed. The total quantity, class types, and locations of the portable fire extinguishers were not in line with the requirements of this table. Prior to the completion of next drydock (March 2026), o/o is to ensure the vessel is equipped with a sufficient quantity of portable fire extinguishers and that all are appropriately rated for the spaces served.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2026
Resolved 24 March 2026
Resolution: MI verified number and placement of fire extinguishers meets table 118.500(a).
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 March 2024
Resolved
If operated in cold water, be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board except each vessel certificated to operate on a lakes, bays, and sounds route within one mile of land is not required to carry survival craft.
Vessel representative self-reported out of service status for one IBA with 150 person capacity due to maintenance. Vessel now has survival craft capacity of 232 total persons. When operating more than one mile of land, vessel passenger count will be reduced to 227 total passengers with 232 total persons allowed.
46 CFR 117.207(c)(1)
46 CFR 117.207 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 18 March 2024
Resolution: Vessel O/O sent in pictures of service reports and re-installed IBAs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 February 2024
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). MI noted failed operation of Void No. 4 bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2024
Resolved 26 February 2024
Resolution: Replaced check valve.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 February 2024
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. MI could not verify if garbage cans were made of non-combustible materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2024
Resolved 25 March 2024
Resolution: O/O purchased and installed approved metal trash cans with metal lids on each deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2022
Resolved
Replace 55 unserviceable adult life jackets. Reduce the total persons allowed on board by 55 adults.
Action required: 705 - Other - as specified
Due 28 April 2022
Resolved 2 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 March 2022
Resolved
IBAs removed from vessel for servicing. Based on LBS route, vessel operating within one mile from land is not required to carry survival craft. Vessel restricted to operating within one mile from land. Notify this office once IBAs are returned to service on vessel.
Action required: 705 - Other - as specified
Resolved 6 April 2022
Resolution: IBAs returned to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2021
Resolved
Mortar in the auxiliary boiler has deteriorated and needs to be replaced. 46CFR61.05
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 13 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 March 2021
Resolved
Watertight door leading to Engine Room has a deteriorated gasket that needs to be replaced. 46CFR171.124
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 13 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 March 2021
Resolved
There is a penetration in Engine Room bulkhead, bulkhead needs to be made watertight.46CFR179.320(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 13 May 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 March 2021
Resolved
Vessel is required to have fire protection and fire plan. 46CFR177.10-5(a)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 13 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 March 2021
Resolved
Thimble missing on wire in steering system. 182.30-1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 13 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 March 2021
Resolved
Rudder stops has cracks present in welds. 46CFR182.610(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 13 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 August 2020
Resolved
33 CFR 164.46/ 17c - A self-propelled vessel of 65 feet or more in length, engaged in commercial service must have on board a properly installed, operational Coast Guard type-approved AIS Class A device. Vessel's AIS was reported inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 August 2020
Resolved 3 August 2020
Resolution: Operator submitted photos of AIS in proper operation. Operator mentioned that a power switch was inadvertently switched off, which is why the AIS unit was not operating initially.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2020
Resolved
Portable fire extinguisher annual servicing expired in May 2020. Service portable fire extinguishers IAW 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 30 June 2020
Resolution: Received report from Western Fire dated 23JUN2020 for servicing of fire extinguisher servicing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2019
Resolved
x1 Fire extinguisher at concession stand requires 2-A.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 24 April 2019
Resolution: Facetime to show 3-A installed at the main deck concession by Chris House.