MAURY USCG vessel records
← All vessels

J LYNN C

Built
1976
Last inspected
6 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ9460
Flag
UNITED STATES
Maury page id
psix-48644

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 17 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 11 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

6 March 2026 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8314625
26 February 2025 Annual Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8083947
25 March 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7884816
17 February 2023 Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7635936
6 April 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7417771
19 March 2021 Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7150781
31 January 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6901737
31 May 2019 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6795338
2 March 2018 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6362155
24 March 2017 Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6108155
15 June 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5906545

Deficiency record · 37

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 February 2025 Resolved
Bilge alarm was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 April 2025
Resolved 25 March 2025
Resolution: Repaired and tested by attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2025 Resolved
Station license expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2025 Resolved
Flexible hoses off the main engine's exhaust were collapsed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Hoses replaced
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 26 February 2025 Resolved
Excesseive oil in the bilges. MI's observed several saturated diapers soaked in oil. Clean and dispose of diapers properly.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Engine room cleaned and diapers were dispoed of properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2025 Resolved
Exhaust system on both mains and generator had several areas of concern including leaks and excessive weld from previous repairs. Replace to the satisfaction of the attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Exhaust was replaced and tested to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2025 Resolved
Air intakes on both mains were dirty (oil). Clean to the satisfaction of attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Air intakes were cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2025 Resolved
Windings on generator were covered in dirty oil. Identify source, clean, to the satisfaction of attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Windings cleaned and oil is reported from crankcase in ER.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 February 2025 Resolved
Lifefloat is not float free due to bent light pole above.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Lifefloat is now float free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2025 Resolved
Fuel shut off valve reach rod is rubbing excessively against exahust in lazerette.Operation of valve is hindered due to being in contact with exhaust.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 March 2025
Resolved 25 March 2025
Resolution: Adjustment made and now shut off valve is working without obstruction.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 February 2023 Resolved
The shutoff valve at the tank shall be operable from outside the tank compartment. Emergency fuel shutoff valve was inoperable when tested from weatherdeck. Reconnect and adjust reach rod to emergency fuel shutoff valve. 46 CFR 182.20-40 (b)(3)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2023 Resolved
Gages to indicate cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. When engine is freshwater cooled and exhaust pipe is cooled by a separate water cooling system, a suitable warning, visible or audible at the operating station, shall be provided. Alarm indicators for exhaust cooling system discharge temperature, jacket water temperature, and L/O pressure on both MDEs were inoperable at both operating stations. Rewire and connect alarms in kind.46 CFR 182.15-5 (b)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2023 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items...(3) Engine control mechanisms. Such mechanisms shall be tested by operation and examined, visually, throughout their length. Fuel shutoff solenoid valves on both MDEs not connected properly effecting remote shutoff capability. 46 CFR 176.25-10 (a)(3)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2023 Resolved
When the exhaust cooling system is separate from the engine cooling system, a suitable warning device shall be provided to indicate any failure of water flow in the exhaust cooling system. Inoperable flowmeter for the exhaust cooling system on both MDEs. Flowmeters to be replaced or repaired. 46 CFR 182.20-15 (a)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2023 Resolved
The engine head, block and exhaust manifold shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating. Jacket water hose for starboard MDE found chaffed with small leak. Replace hose in kind. 46 CFR 182.20-10 (b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2023 Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas-tight throughout its length and shall be properly supported by non-combustible hangers or blocks. MI identified cracked weld in port exhaust support. Grind and re-weld. 46 CFR 182.15-20 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 April 2022 Resolved
46 CFR 183.10-5(f)(2): Generators and motors designed for 40 degrees Celsius may be used in 50 degrees Celsius ambient locations provided the machines are derated to 80 percent of full load rating or setting of the overcurrent devices is reduced accordingly. An additional nameplate specifying the derated capacity shall be provided for each such motor and generator. MI found nameplate specifying generator was designed for 40 degrees Celsius, and generator was not derated. Provide nameplate for the generator's capacity in design for 50 degrees Celsius or that the generator has been derated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: Received tag proving the generator is rated for 50 degree Celsius ambient operation.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 April 2022 Resolved
46 CFR 176-25-35(a): At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. MI found the rudder stop mount cracked at the base on two of the three mounting points, allowing the rudder to move further than intended. Repair the cracks for the based to provide proper stopping points.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Vessel rudder stop mount was repaired by welding the mount to the frame.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 April 2022 Resolved
46 CFR 183.05-20(b): Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. MI found batteries not secured to prevent motion. Add shoring to prevent possible battery shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Rep placed wood shoring in the batteries to prevent shifting.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 6 April 2022 Resolved
46 CFR 182.20-35(d): The discharge ends of vent pipes shall be fitted with removable flame screens of flames arresters. MI found the fuel tank vent with no vent screen attached. Place at least a single screen of corrosion resistant wire of at least 30 x 30 mesh.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Placed a 30 x 30 mesh screen on the fuel tank vent.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2022 Resolved
46 CFR 180.70(b)(3): Each life ring buoy on a vessel must: Be stowed in a way that it can be rapidly cast loose. MI found the lifeline tied to itself, not allowing full extension if deployed. Lifeline needs to be readily deployable to it's full length.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2022
Resolution: Rep detangled the throw line and placed in a bag.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 April 2022 Resolved
47 CFR 80.905(a)(5): Vessels must comply with the requirements for a navigation receiver or manual updating of position information contained in 47 CFR 80.1085. MI found the VHF radio not displaying the vessels coordinates.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Radio was programmed and shows position of the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 April 2022 Resolved
46 CFR 121.24(b)(1): Each hatch cover must have securing devices. MI found the Engine Room hatch securing bolts not long enough to sufficiently secure the hatch. Replace with a bolt of appropriate size to secure the hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Longer hardware was placed in the hatch which can now be secured from opening while transiting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 April 2022 Resolved
46 CFR 176.25-10(a)(3): Engine control mechanisms. Such mechanisms shall be tested by operation and examined, visually, throughout their length. MI found the Port engine Reduction gear cable heavily chafed. Place chafing protection on the cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Replaced the reduction gear cable and placed chafing to prevent future wear.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 March 2017 Resolved
Replace STBD engine battery cable due to melted casing as indicated by Marine Inspector during engine room exam.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2017
Resolved 3 April 2017
Resolution: Battery Cable replaced to satisfaction of attending MI.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 March 2017 Resolved
Rearrange lifejacket storage in main cabin to make ease of access more accessible. Current storage does not allow for easy removal.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2017
Resolved 3 April 2017
Resolution: Life Jackets restowed to make them more accessible, to satisfaction of attending MI.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 March 2017 Resolved
Crew failed man overboard drill, deckhand was unfamiliar with vessel equipment and procedures. Prior to commercial operations, crew shall conduct man overboard drill to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 27 March 2017
Resolution: Attending marine inspector witnessed satisfactory man overboard drill.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 March 2017 Resolved
Vessel is required to have emergency instructions mounted at the operating station that the master and crew shall be familiar with. The contact of the emergency instructions shall contain actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2017
Resolved 27 March 2017
Resolution: Vessel owner placed emergency instructions at the operating station and conducted man overboard drill to show familiarity with content.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 March 2017 Resolved
Wires in the engine room shall be hung using metal clips, not zip ties.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 3 April 2017
Resolution: Wires were tied using metal clips to satisfaction of attending MI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 March 2017 Resolved
Vessels great than 40' in length shall have "Not Under Command" lights. Vessel is restricted to daytime operation until the deficiency is corrected.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 3 April 2017
Resolution: "Not Under Command" Light installed and operating correctly to satisfaction of attending MI.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 27 March 2017 Resolved
Vessel's greater than 40' in length shall have day shapes.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 27 March 2017
Resolution: Vessel owner purchased day shapes to be placed on the vessel.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 27 March 2017 Resolved
Vessel's greater tjam 40' in length, using a route greater than 3NM from shore, shall have a waste management plan.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 5 April 2017
Resolution: RCVD Copy of new Waste Management Plan satisfying requirements.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 March 2017 Resolved
Replace lanyard on ring lifebuoy floating water light. Lanyard shall be at least 3' but not more than 6' in length. Current lanyard is 9'.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 3 April 2017
Resolution: Lanyard on life float light was replaced with correct length lanyard to satisfaction of attending MI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 March 2017 Resolved
a two-year salt water service dry dock interval schedule. Company failed to make the vessel available for dry dock inspection within two years of its last credited dry dock on February 12, 2015. In addition, company carried passengers on the vessel between 12FEB17 and the date the dry dock occurred on 24MAR17.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Attending Marine Inspector conducted dry dock inspection. All sat. Letter of Warning was issued to the vessel owner, CORKERN CREWBOAT SERVICE, INC, for missing the dry dock.
Engineering › Bilge Water Management System › Interface Detector
Issued 15 June 2016 Resolved
E/R & Lazarette bilge alarms did not indicate.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 20 June 2016
Resolution: Completed def. check bilge alarms indicated. Loose wire was cause, Bilge alarm for engine room and lazarette rewired.
Lifesaving › Lifefloat › Paddle
Issued 15 June 2016 Resolved
Lifefloat does not have paddles as required.
Due 1 July 2016
Resolved 20 June 2016
Resolution: Completed def check 2 paddles were provided.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 15 June 2016 Resolved
Distribution panel at operating station; determine proper amperage for corresponding equipment and label accordingly.
Due 1 July 2016
Resolved 20 June 2016
Resolution: Electrical system was traced out, breakers labeled properly along w/ proper amperage required by equipment.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 June 2016 Resolved
Master did not have MMC and FCC Operators license onboard.
Due 1 July 2016
Resolved 15 June 2016
Resolution: Master produced MMC Credentials & FCC Operators license.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.