Records from 1982 to 2026. Most recent: inspection, 6 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 49
6 March 2026
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8314625
26 February 2025
Annual Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8083947
25 March 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7884816
17 February 2023
Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7635936
6 April 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7417771
19 March 2021
Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7150781
31 January 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6901737
31 May 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6795338
2 March 2018
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6362155
24 March 2017
Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6108155
15 June 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5906545
13 May 2014
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4843502
14 February 2011
DAPI Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3937930
25 February 2010
DAPI Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3690453
19 January 2010
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3659393
5 February 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3401099
12 August 2008
Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3288955
31 January 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3131611
25 January 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2858537
10 August 2006
Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2741668
6 January 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2562189
4 January 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2561573
8 July 2004
Examination of Repairs · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2125783
4 September 2003
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1896606
12 August 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1873946
10 October 2002
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1687722
4 September 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1670743
22 July 2002
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1650372
4 October 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1074723
6 September 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447136
12 September 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1054196
17 August 2000
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399348
22 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1127721
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188692
13 June 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335302
28 May 1991
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930150
4 October 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1226746
14 August 1990
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 912390
3 October 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326567
2 June 1988
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 887326
8 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001693
19 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021679
5 June 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298048
27 March 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999556
26 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289106
23 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975128
30 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966349
22 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276333
23 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969444
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 February 2025
Resolved
Bilge alarm was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 April 2025
Resolved 25 March 2025
Resolution: Repaired and tested by attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2025
Resolved
Station license expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2025
Resolved
Flexible hoses off the main engine's exhaust were collapsed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Hoses replaced
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 26 February 2025
Resolved
Excesseive oil in the bilges. MI's observed several saturated diapers soaked in oil. Clean and dispose of diapers properly.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Engine room cleaned and diapers were dispoed of properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2025
Resolved
Exhaust system on both mains and generator had several areas of concern including leaks and excessive weld from previous repairs. Replace to the satisfaction of the attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Exhaust was replaced and tested to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2025
Resolved
Air intakes on both mains were dirty (oil). Clean to the satisfaction of attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Air intakes were cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2025
Resolved
Windings on generator were covered in dirty oil. Identify source, clean, to the satisfaction of attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Windings cleaned and oil is reported from crankcase in ER.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 February 2025
Resolved
Lifefloat is not float free due to bent light pole above.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2025
Resolution: Lifefloat is now float free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2025
Resolved
Fuel shut off valve reach rod is rubbing excessively against exahust in lazerette.Operation of valve is hindered due to being in contact with exhaust.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 March 2025
Resolved 25 March 2025
Resolution: Adjustment made and now shut off valve is working without obstruction.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 February 2023
Resolved
The shutoff valve at the tank shall be operable from outside the tank compartment. Emergency fuel shutoff valve was inoperable when tested from weatherdeck. Reconnect and adjust reach rod to emergency fuel shutoff valve. 46 CFR 182.20-40 (b)(3)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2023
Resolved
Gages to indicate cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. When engine is freshwater cooled and exhaust pipe is cooled by a separate water cooling system, a suitable warning, visible or audible at the operating station, shall be provided. Alarm indicators for exhaust cooling system discharge temperature, jacket water temperature, and L/O pressure on both MDEs were inoperable at both operating stations. Rewire and connect alarms in kind.46 CFR 182.15-5 (b)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2023
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items...(3) Engine control mechanisms. Such mechanisms shall be tested by operation and examined, visually, throughout their length. Fuel shutoff solenoid valves on both MDEs not connected properly effecting remote shutoff capability.
46 CFR 176.25-10 (a)(3)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2023
Resolved
When the exhaust cooling system is separate from the engine cooling system, a suitable warning device shall be provided to indicate any failure of water flow in the exhaust cooling system. Inoperable flowmeter for the exhaust cooling system on both MDEs. Flowmeters to be replaced or repaired.
46 CFR 182.20-15 (a)
Action required: 60 - Rectify deficiencies prior to movement
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2023
Resolved
The engine head, block and exhaust manifold shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating. Jacket water hose for starboard MDE found chaffed with small leak. Replace hose in kind. 46 CFR 182.20-10 (b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2023
Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas-tight throughout its length and shall be properly supported by non-combustible hangers or blocks. MI identified cracked weld in port exhaust support. Grind and re-weld.
46 CFR 182.15-20 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 27 February 2023
Resolution: Witnessed all repairs to be Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 April 2022
Resolved
46 CFR 183.10-5(f)(2): Generators and motors designed for 40 degrees Celsius may be used in 50 degrees Celsius ambient locations provided the machines are derated to 80 percent of full load rating or setting of the overcurrent devices is reduced accordingly. An additional nameplate specifying the derated capacity shall be provided for each such motor and generator. MI found nameplate specifying generator was designed for 40 degrees Celsius, and generator was not derated. Provide nameplate for the generator's capacity in design for 50 degrees Celsius or that the generator has been derated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: Received tag proving the generator is rated for 50 degree Celsius ambient operation.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 April 2022
Resolved
46 CFR 176-25-35(a): At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. MI found the rudder stop mount cracked at the base on two of the three mounting points, allowing the rudder to move further than intended. Repair the cracks for the based to provide proper stopping points.
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Vessel rudder stop mount was repaired by welding the mount to the frame.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 April 2022
Resolved
46 CFR 183.05-20(b): Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. MI found batteries not secured to prevent motion. Add shoring to prevent possible battery shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Rep placed wood shoring in the batteries to prevent shifting.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 6 April 2022
Resolved
46 CFR 182.20-35(d): The discharge ends of vent pipes shall be fitted with removable flame screens of flames arresters. MI found the fuel tank vent with no vent screen attached. Place at least a single screen of corrosion resistant wire of at least 30 x 30 mesh.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Placed a 30 x 30 mesh screen on the fuel tank vent.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2022
Resolved
46 CFR 180.70(b)(3): Each life ring buoy on a vessel must: Be stowed in a way that it can be rapidly cast loose. MI found the lifeline tied to itself, not allowing full extension if deployed. Lifeline needs to be readily deployable to it's full length.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2022
Resolution: Rep detangled the throw line and placed in a bag.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 April 2022
Resolved
47 CFR 80.905(a)(5): Vessels must comply with the requirements for a navigation receiver or manual updating of position information contained in 47 CFR 80.1085. MI found the VHF radio not displaying the vessels coordinates.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Radio was programmed and shows position of the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 April 2022
Resolved
46 CFR 121.24(b)(1): Each hatch cover must have securing devices. MI found the Engine Room hatch securing bolts not long enough to sufficiently secure the hatch. Replace with a bolt of appropriate size to secure the hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Longer hardware was placed in the hatch which can now be secured from opening while transiting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 April 2022
Resolved
46 CFR 176.25-10(a)(3): Engine control mechanisms.
Such mechanisms shall be tested by operation and examined, visually, throughout their length. MI found the Port engine Reduction gear cable heavily chafed. Place chafing protection on the cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2022
Resolution: Replaced the reduction gear cable and placed chafing to prevent future wear.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 March 2017
Resolved
Replace STBD engine battery cable due to melted casing as indicated by Marine Inspector during engine room exam.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2017
Resolved 3 April 2017
Resolution: Battery Cable replaced to satisfaction of attending MI.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 March 2017
Resolved
Rearrange lifejacket storage in main cabin to make ease of access more accessible. Current storage does not allow for easy removal.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2017
Resolved 3 April 2017
Resolution: Life Jackets restowed to make them more accessible, to satisfaction of attending MI.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 March 2017
Resolved
Crew failed man overboard drill, deckhand was unfamiliar with vessel equipment and procedures. Prior to commercial operations, crew shall conduct man overboard drill to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 27 March 2017
Resolution: Attending marine inspector witnessed satisfactory man overboard drill.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 March 2017
Resolved
Vessel is required to have emergency instructions mounted at the operating station that the master and crew shall be familiar with. The contact of the emergency instructions shall contain actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2017
Resolved 27 March 2017
Resolution: Vessel owner placed emergency instructions at the operating station and conducted man overboard drill to show familiarity with content.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 March 2017
Resolved
Wires in the engine room shall be hung using metal clips, not zip ties.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 3 April 2017
Resolution: Wires were tied using metal clips to satisfaction of attending MI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 March 2017
Resolved
Vessels great than 40' in length shall have "Not Under Command" lights. Vessel is restricted to daytime operation until the deficiency is corrected.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 3 April 2017
Resolution: "Not Under Command" Light installed and operating correctly to satisfaction of attending MI.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 27 March 2017
Resolved
Vessel's greater than 40' in length shall have day shapes.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 27 March 2017
Resolution: Vessel owner purchased day shapes to be placed on the vessel.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 27 March 2017
Resolved
Vessel's greater tjam 40' in length, using a route greater than 3NM from shore, shall have a waste management plan.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 5 April 2017
Resolution: RCVD Copy of new Waste Management Plan satisfying requirements.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 March 2017
Resolved
Replace lanyard on ring lifebuoy floating water light. Lanyard shall be at least 3' but not more than 6' in length. Current lanyard is 9'.
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 3 April 2017
Resolution: Lanyard on life float light was replaced with correct length lanyard to satisfaction of attending MI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 March 2017
Resolved
a two-year salt water service dry dock interval schedule. Company failed to make the vessel available for dry dock inspection within two years of its last credited dry dock on February 12, 2015. In addition, company carried passengers on the vessel between 12FEB17 and the date the dry dock occurred on 24MAR17.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Attending Marine Inspector conducted dry dock inspection. All sat. Letter of Warning was issued to the vessel owner, CORKERN CREWBOAT SERVICE, INC, for missing the dry dock.
Engineering › Bilge Water Management System › Interface Detector
Issued 15 June 2016
Resolved
E/R & Lazarette bilge alarms did not indicate.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 20 June 2016
Resolution: Completed def. check bilge alarms indicated. Loose wire was cause, Bilge alarm for engine room and lazarette rewired.
Lifesaving › Lifefloat › Paddle
Issued 15 June 2016
Resolved
Lifefloat does not have paddles as required.
Due 1 July 2016
Resolved 20 June 2016
Resolution: Completed def check 2 paddles were provided.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 15 June 2016
Resolved
Distribution panel at operating station; determine proper amperage for corresponding equipment and label accordingly.
Due 1 July 2016
Resolved 20 June 2016
Resolution: Electrical system was traced out, breakers labeled properly along w/ proper amperage required by equipment.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 June 2016
Resolved
Master did not have MMC and FCC Operators license onboard.
Due 1 July 2016
Resolved 15 June 2016
Resolution: Master produced MMC Credentials & FCC Operators license.
Documentation › Logs/Records › Drug Test Records
Issued 25 February 2010
Resolved
Company was missing the last five years of positive drug test results.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 February 2010
Resolved 25 February 2010
Resolution: Unable to retrieve most records lost due to Hurricane Katrina.
Lifesaving › Lifefloat › Float-free Link
Issued 19 January 2010
Resolved
Float free link missing tag.
Condition: Improper Installation
Due 26 January 2010
Resolved 2 February 2010
Resolution: New float free link with tag was added.
Lifesaving › Lifefloat › Serviceable
Issued 19 January 2010
Resolved
Make repairs to life float in way of a 2"x2" fracture above label plate. Lifefloat serial # 6-891
Condition: Unknown
Due 19 February 2010
Resolved 2 February 2010
Resolution: Life float was replaced with new one.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 January 2010
Resolved
Prove vessel has a valid drug and alcohol plan.
Condition: Unknown
Due 19 February 2010
Resolved 3 March 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 January 2010
Resolved
Make repairs to compass light. Compass light bulb not mounted correctly.
Condition: Unknown
Due 19 February 2010
Resolved 2 February 2010
Resolution: Compass light bulb mounted correctly.
Communications › Radio Communications › EPIRB
Issued 19 January 2010
Resolved
Replace EPIRB hydro, hydro expired.
Due 26 January 2010
Resolved 2 February 2010
Resolution: EPIRB hydro was replaced.
Documentation › Certificates/Documents › FCC SSL
Issued 19 January 2010
Resolved
Obtain a FCC Radio Safety Certificate IAW 47 CFR 80.401
Condition: Unknown
Due 19 February 2010
Resolved 2 February 2010
Resolution: Radio safety certificate was acquired and onboard.
Electrical › Electrical Distribution System (service)
Issued 12 August 2003
Resolved
Properly wire refer. TV & microwave oven IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 2 September 2003
Stability › Weathertight Integrity
Issued 12 August 2003
Resolved
Repair or replace weathertight door aft main deck to passenger compartment. LEGACY COMPONENT DESC: Weathertight door
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 2 September 2003
Navigation › Piloting/Steering
Issued 12 August 2003
Resolved
Replace & install double nuts to stboard side rudder packing assembly. LEGACY COMPONENT DESC: Rudder Packing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2003
Resolved 2 September 2003
Lifesaving › Visual Distress Signals (General)
Issued 4 September 2002
Resolved
Provide watertight container for distress flares that is bright in color and marked "Distress Signals" in contrasting color at least 1/2" high. LEGACY COMPONENT DESC: Storage
Due 5 October 2002
Resolved 10 October 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 September 2002
Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 5 October 2002
Resolved 10 October 2002
Lifesaving › Lifebuoys
Issued 4 September 2002
Resolved
Replace retro on lifering.
Due 5 October 2002
Resolved 10 October 2002
Construction/Loadline › Penetrations
Issued 4 September 2002
Resolved
Make bulkhead between machinery space and passenger compartment watertight/vapor tight. Stbd side shows light through stuffing tube.
Due 5 October 2002
Resolved 10 October 2002
Engineering
Issued 4 September 2002
Resolved
Install exhaust lagging on generator exhaust between manifold and where water is injected.
Due 5 October 2002
Resolved 10 October 2002
Construction/Loadline › Hull
Issued 4 September 2002
Resolved
Repair cracks in Lazarette port side along hull to deck. Also repair crack in steering ram bracket. Insert minimum of 18" x 18" in bow: crack between #1 & #2 stbd side longitudinal. LEGACY COMPONENT DESC: Hull Plating
Due 5 October 2002
Resolved 16 October 2002
Engineering › Bilge Water Management System
Issued 4 September 2002
Resolved
Bilge pump suction line in the passenger compartment needs strainer installed that is three times the pipe size.
Due 5 October 2002
Resolved 10 October 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 September 2002
Resolved
Renew retro reflective material on all life jackets in correct position and on both sides of jacket. (46 CFR 180.25-25) LEGACY COMPONENT DESC: Retroreflective Material
Due 5 October 2002
Resolved 10 October 2002
Fire Fighting
Issued 6 September 2001
Resolved
PROVE PROPER CHARGE ON PORTABLE FIRE EXTINGUISHER AT FIRE STATION NO. 3 IN PASSENGER COMPARTMENT.
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Documentation
Issued 6 September 2001
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Documentation
Issued 17 August 2000
Resolved
POST EMERGENCY BROADCAST PLACARD BY RADIO
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Documentation
Issued 17 August 2000
Resolved
SUBMIT MANAGEMENT INFORMATION SYSTEM FOR CHEMICAL DRUG TESTING TO CG HEADQUARTERS
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Engineering
Issued 17 August 2000
Resolved
INSTALL GUARDS OVER ROTATING MACHINERY ON BOTH MAIN ENGINES & GENERATOR
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Documentation
Issued 17 August 2000
Resolved
PROVIDE UPDATED TIDAL CURRENT TABLE
Condition: Unknown
Due 17 August 2000
Resolved 17 August 2000
Engineering
Issued 28 May 1991
Resolved
PERFORM OPERATIONAL TEST OF BOTH MAIN DIESEL ENGINES AND SHIP'S SERVICE DIESEL GENERATOR IN PRESENCE OF USCG INSPECTOR.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Navigation
Issued 28 May 1991
Resolved
INSTALL DOUBLE NUT ON HYDRAULIC RAM FOR STEERING SYSTEM.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Electrical
Issued 28 May 1991
Resolved
PROVIDE BATTERY BOX COVERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Electrical
Issued 28 May 1991
Resolved
INSTALL GLOBE AND GUARD ON BOTH LIGHTS IN ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Engineering
Issued 28 May 1991
Resolved
INSTALL FUEL OIL PIPING SUPPORTS TO PREVENT HOSES FROM LAYING IN BILGES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Lifesaving
Issued 28 May 1991
Resolved
LASH PADDLES TO LIFEFLOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Lifesaving
Issued 28 May 1991
Resolved
ATTACH 60 FT. LINE TO RINGBUOY.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Fire Fighting
Issued 28 May 1991
Resolved
SERVICE ALL FIRE EXTINGUISHERS ONBOARD.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Fire Fighting
Issued 14 August 1990
Resolved
THE FIRE PUMP OPERATED OFF THE PORT-ENGINE MUST HAVE THE APPROPRIATE SEA STRAINER WITHIN THE LINE.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990