QUINN RIVER

QUINN RIVER is a 1976 offshore supply vessel. The Coast Guard has recorded 36 inspections since 1982, most recently in April 2008, along with 28 deficiencies — 13 with no resolution recorded —.

Records from 1982 to 2008. Most recent: inspection, 17 April 2008.

Built
1976
Last inspected
17 April 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC9126
Flag
UNITED STATES
303588000 (licence lapsed)
Maury page id
psix-48646

Inspections, by type

…with no type recorded11
…past their stated due date8
Years with a record 24 calendar years (1982–2008)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC9126MMSI 303588000 · expired · compulsorily equipped · granted 9 March 2006, cancelled 14 May 2016
WCY2925MMSI not assigned · expired · compulsorily equipped · granted 9 April 1998, cancelled 14 June 2008
WCX4257MMSI not assigned · cancelled · voluntarily equipped · granted 25 April 1997, cancelled 4 April 2003
WCW8809MMSI not assigned · expired · compulsorily equipped · granted 23 September 1996, cancelled 25 November 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 36

17 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3186183
16 July 2007 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2997551
6 April 2006 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2618025
20 February 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1487625
15 February 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425089
16 January 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 467938
19 October 2000 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823288
10 October 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 17902
25 February 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415305
3 February 2000 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 86480
11 January 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 496053
13 October 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 5760
1 March 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424713
27 February 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386209
2 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784239
28 February 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456449
16 January 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353858
31 January 1995 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416085
27 January 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356499
29 March 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443368
28 January 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1006507
21 January 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947321
9 April 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920354
9 February 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911204
22 September 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1321925
21 July 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342110
30 November 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315308
27 July 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1339226
29 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310289
23 July 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300512
1 August 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298946
16 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283931
26 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974656
29 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276447
5 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966600
25 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964186

Deficiency record · 28

Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 April 2008 No resolution recorded
2 Kapok lifejackets were found with busted internal floatation. Replace lifejackets.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2008 — due date passed with no resolution recorded
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 April 2008 No resolution recorded
Missing Coast Pilot publication. Aquire publication
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 May 2008 — due date passed with no resolution recorded
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 April 2008 No resolution recorded
Approach chart for Fourchon is missing. Aquire chart.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 April 2008 No resolution recorded
Bilge alarms forward of steering compartment did not work. Fix alarms.
Action required: 17 - Rectify deficiencies prior to departure
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 April 2008 No resolution recorded
Missing cover on electrical junction box in the engine room. Replace cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2008 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Hose
Issued 17 April 2008 No resolution recorded
Secondary plug missing on fuel siphon hose. Replace plug.
Action required: 705 - Other - as specified
Due 17 May 2008 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 April 2008 No resolution recorded
Remove deadend wires from battery charger cables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2008 — due date passed with no resolution recorded
Communications › Visual Communication › Warning Sign (radio room)
Issued 17 April 2008 No resolution recorded
Label phone box.
Action required: 705 - Other - as specified
Due 17 May 2008 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Coaming
Issued 17 April 2008 No resolution recorded
Bottom knife edge of watertight door is wasted. Crop and renew ledge.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Compressed Air System (start air) › Valve
Issued 17 April 2008 No resolution recorded
Air receiver's pressure gauge is missing. Replace guage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2008 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 April 2008 No resolution recorded
Leaks found in MDE exhaust near supporting framework. Fix and cover with lagging.
Action required: 705 - Other - as specified
Due 17 May 2008 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2008 No resolution recorded
Replace nav light bulbs with marine grade.
Action required: 17 - Rectify deficiencies prior to departure
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2008 No resolution recorded
2 Nav lights fixtures found busted. Replace fixtures
Action required: 17 - Rectify deficiencies prior to departure
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 July 2007 Resolved
Engine room and steering compartment bilge alarms wired into same indicator light on bridge. Wire alarms to seperate indicator lights for each compartment.
Due 10 August 2007
Resolved 28 August 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 July 2007 Resolved
Several motor controllers in engineroom were missing covers. The missing covers exposed hazards. (air comp., bilge pump)
Due 16 July 2007
Resolved 16 July 2007
Resolution: Exposed hazards were covered with appropriate covers.
Stability › Watertight Integrity › General
Issued 10 July 2007 Resolved
Remove paint/clean watertight door knife edges.
Due 10 August 2007
Resolved 31 August 2007
Resolution: Received email documentation from [name withheld] that he witnessed satisfactory chaulk testing of knife edge.
Stability › Unintentional Flooding › General
Issued 10 July 2007 Resolved
Shaft packings were leaking excessively. Tighten shaft packings to minimize water intrusion.
Due 10 August 2007
Resolved 31 August 2007
Resolution: Received 3rd party service report.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 10 July 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 31 August 2007
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 July 2007 Resolved
Vessel did not have current nav publications on board. (Tides, Currents, and Coast Pilot)
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: All new Nav publications were onboard.
Engineering › Compressed Air System (start air) › Valve
Issued 2 July 2007 Resolved
Test or replace pressre relief valves on pressure vessels.
Due 10 July 2007
Resolved 10 July 2007
Resolution: New pressure relief valves were installed on pressure vessel.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 July 2007 Resolved
Vessel needs to be cleaned. Remove all unnecessary rags, and rubbish.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Vessel was satisfactorily cleaned.
Lifesaving › Lifefloat › Painter
Issued 2 July 2007 Resolved
Painter in between lifefloats must be spliced around body of lifefloat.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Painter was spliced correctly onto lifefloat.
Communications › Alarms/Indicators
Issued 20 February 2002 Resolved
PROPERLY INSTALL ENGINE ROOM BILGE HIGH LEVEL ALARM. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2002
Resolved 8 March 2002
Engineering › Diesel Engine (auxiliary)
Issued 20 February 2002 Resolved
INSTALL GUARDS ON FIRE MONTOR ENGINE SHAFT AND BILGE PUMP SHAFT. LEGACY COMPONENT DESC: SHAFT GUARD
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 April 2002
Resolved 7 March 2002
Navigation › Piloting/Steering
Issued 20 February 2002 Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON STEERING GEAR FLEXIBLE HOSES. LEGACY COMPONENT DESC: FLEXIBLE HOSES
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2002
Resolved 7 March 2002
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 20 February 2002 Resolved
HYDRO OR RENEW LOWER ENGINE ROOM AIR RECEIVER WITH APPROVED PRESSURE VESSEL DUE TO OUTSIDE PITTING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2002
Resolved 8 March 2002
Fire Fighting › Fire Pumps › Pressure
Issued 20 February 2002 Resolved
FIRE PUMP WILL NOT MEET 60 PSI REQUIRED PRESSURE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2002
Resolved 8 March 2002
Resolution: RENEWED FIRE PUMP, 53 PSI AND 65 GPM APPROVED BY CID.
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 February 2001 Resolved
Install and demonstrate proper operation of bilge alarm visual indicator atoperating station to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 1 April 2001
Resolved 4 April 2006
Resolution: Bilge alarms all in working order.

Ownership record