← All vessels
MS. NORMA
MS. NORMA is a 1976 offshore supply vessel. The Coast Guard has recorded 60 inspections since 1981, most recently in November 2020, along with 64 deficiencies and 1 casualty investigation in 2014.
Records from 1981 to 2020. Most recent: inspection, 17 November 2020.
- Built
- 1976
- Last inspected
- 17 November 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 64 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2014
Identity
571565
7505853 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCX8258
48655
Flag
UNITED STATES
367010310 (licence lapsed)
Maury page id
psix-48655
Inspections, by type
…with no type recorded15
Years with a record
31 calendar years (1981–2020)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it669 - Convention (Subpart B), Gross Ton
200 - Convention (Subpart B), Net Ton
200 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCX8258MMSI 367010310 · expired · compulsorily equipped · granted 9 August 2007, cancelled 6 January 2018 · licensed under a name not among this hull’s recorded names (not shown)
WCX5689MMSI not assigned · expired · compulsorily equipped · granted 26 June 1997, cancelled 1 September 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 60
17 November 2020
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7105864
25 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5905387
8 February 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4240777
20 December 2010
Cargo Tank Internal · Internal Structural Exam · MTSA Verification · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3912417
22 January 2010
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3667920
23 October 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3350153
12 February 2008
Examination of Repairs · COI Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3145816
14 May 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977622
6 June 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2867286
18 November 2005
Hull Examination · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2538290
29 March 2005
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2322518
10 March 2005
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2307612
23 February 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2297832
20 February 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2297710
10 March 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2021908
16 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971690
14 March 2003
Hull Examination · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1770400
10 December 2002
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1717275
21 November 2002
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1704692
16 October 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1690950
5 September 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366556
20 September 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403228
14 October 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455769
24 September 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461080
8 April 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368744
23 October 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364491
20 August 1997
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 758006
13 August 1997
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 195826
16 January 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1364077
27 March 1996
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1078160
1 March 1996
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 884551
8 December 1995
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360328
2 February 1995
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1417734
16 February 1994
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 853012
11 January 1994
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1417597
8 December 1993
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 836640
29 April 1993
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1382582
12 November 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1471647
11 September 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1263556
2 June 1992
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362630
16 April 1992
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 958218
4 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923033
31 January 1991
Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1242306
22 October 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231189
11 October 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912869
24 September 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905737
26 October 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1023746
24 September 1988
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 890132
11 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335935
22 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314566
10 December 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995630
3 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285990
15 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291455
18 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984248
22 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279664
4 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971909
3 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971450
6 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963826
16 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274697
5 October 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968471
Deficiency record · 64
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 February 2012
Resolved
Reach Rod T-handle weld broken
Fire Fighting › Portable Foam Applicators › General
Issued 8 February 2012
Resolved
Inline educator not working.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 February 2012
Resolved
Batteries need replacing.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 February 2008
Resolved
Replace faded retro tape on two lifebuoys as directed.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 February 2008
Resolved
Replace broken plastic safety cover on light fixture in engineer's state room.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 February 2008
Resolved
Renew safety harness required for MOB drill evolutions.
Construction/Loadline › Structures › Door
Issued 12 February 2008
Resolved
Adjust all w/t doors per ABS surveyor's direction.
Communications › Audible Communications › Horn/Whistle
Issued 12 February 2008
Resolved
Repair air horn on vsl's bridge.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 3 March 2006
Resolved
33U.S.C.1321(j)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge
33U.S.C.1321(j)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 3 March 2006
Resolved
33U.S.C.1321(j)(D)(ii)-The NTVRP does not identify a qualified individual, provide 24-hour contract information for the qualified individual, or indicate that the qualified individual will have immediate contact with the NRC and the oil spill removal organization
33U.S.C.1321(j)D)(iv)-The NTVRP does not address training as well as all applicable drill/exercise frequencies
Engineering › Fuel Oil Service System › Piping
Issued 10 March 2005
Resolved
Repair holed fuel oil manifold IWO engine room (soft patch).
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 March 2003
Resolved
ADJUST EMERGENCY LIGHTS TO ILLUMINATE EMERGENCY EXITS.
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 March 2003
Resolved
PROVIDE PROPER CONNECTORS FOR BATTERIES.
Stability › Watertight Integrity
Issued 31 March 2003
Resolved
ADJUST DOGS ON MAIN DECK DOOR. LEGACY COMPONENT DESC: WATERTIGHT DOORS
Electrical › Electrical Distribution System (service) › Panelboard
Issued 31 March 2003
Resolved
REPAIR STEERING PUMPS INDICATORS LIGHTS FOR #1 PUMP.
Pollution Prevention/Response
Issued 21 November 2002
Resolved
Determine what the sludge is in the bilge of the tunnel and the source. Also remove sludge if it is in-fact oil based.
Engineering › Fuel Oil Service System
Issued 16 October 2002
Resolved
Provide flange cover shield over fuel flange piping. LEGACY COMPONENT DESC: Piping
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Adjust water tight door on 01 deck next to dryer.
Engineering › Steering Gear System
Issued 16 October 2002
Resolved
Adjust steering gear so that it doesn't hit rudder stop.
Lifesaving
Issued 20 September 2000
Resolved
DEMONSTRATE PROPER OPERATION OF THE INSTALLED PILOTHOUSE ALARM PANEL , TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Engineering
Issued 20 September 2000
Resolved
DEMONSTRATE PROPER OPERATION OF PORT AND STBD FUEL OIL REACH RODS, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Documentation
Issued 14 October 1999
Resolved
Provide evidence that vessel was built under Coast Guard inspection IAW PL 96-378.
Deck/Cargo
Issued 14 October 1999
Resolved
Permanently mount liquid mud containment enclosures.
Lifesaving
Issued 14 October 1999
Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District Policy Ltr. dated 12NOV98 "Rescue Boat Requirements on Offshore Supply Vessels" to the satisfaction of the attending Marine Inspector.
Fire Fighting
Issued 14 October 1999
Resolved
Provide an ammended and correct Fire and Safety plan.
Engineering
Issued 14 October 1999
Resolved
Refurbish stuffing tubes for reach rods.
Navigation
Issued 1 March 1996
Resolved
PROVE THAT RUDDER ANGLE INDICATOR IN PILOTHOUSE MATCHES ACTUAL RUDDER ANGLEAS WELL AS ENGINEROOM INDICATOR.
Engineering
Issued 8 December 1995
Resolved
PROVIDE HAND HELD TACH TO TEST O/S TRIP ON BOTH GENERATORS.
Fire Fighting
Issued 8 December 1995
Resolved
PROCURE FLAME SAFETY LAMP OR OXYGEN METER FOR FIREMAN OUTFIT.
Lifesaving
Issued 8 December 1995
Resolved
PROCURE AUXILIARY LINE FOR LINE THROWING GUN I.A.W. 46 CFR 94.45-15(b)(6).
Lifesaving
Issued 8 December 1995
Resolved
PROVIDE 3 ADDITIONAL CARTRIDGES FOR A TOTAL OF 25 CARTRIDGES FOR SHOULDER LINE THROWING GUN I.A.W. 46 CFR 94.45-15(b)(2).
Construction/Loadline
Issued 8 December 1995
Resolved
REPAIR AFT BILGE HIGH WATER ALARM SENSOR.
Navigation
Issued 8 December 1995
Resolved
PROVE THAT RUDDER ANGLE INDICATOR AT PILOT HOUSE MATCHES TRUE POSITION OF RUDDER.
Electrical
Issued 8 December 1995
Resolved
INSTALL PROTECTIVE GUARDS ON BOTH GENERATORS AROUND VIBRATION DAMPENERS.
Engineering
Issued 8 December 1995
Resolved
REPAIR BOTH THE STBD/PORT SHAFT TACH/DIRECTION INDICATOR.
Construction/Loadline
Issued 8 December 1995
Resolved
PROPERLY MARK WTD LEADING TO ENGINEROOM AND AFT STEERING COMPARTMENT.
Fire Fighting
Issued 8 December 1993
Resolved
Provide proposal to cognizant OCMI for review to make fire pump operable from outside of machinery space.
Electrical
Issued 8 December 1993
Resolved
Fit main switchboard with interlock bar.
Lifesaving
Issued 8 December 1993
Resolved
Fit guards on sight glasses in machinery space.
Unknown
Issued 8 December 1993
Resolved
Provide standard discharge connection per 33 CFR 155.420, 155.430
Engineering
Issued 2 June 1992
Resolved
DEMONSTRATE AUTOMATION OF VITAL SYSTEM USING SUBMITTED TEST PROCEDURES._x001C_
Lifesaving
Issued 16 April 1992
Resolved
CONDUCT FIRE AND BOAT DRILLS.
Lifesaving
Issued 16 April 1992
Resolved
PROVIDE TWO COMPLETE FIREMAN OUTFITS.
Lifesaving
Issued 16 April 1992
Resolved
PROPERLY MOUNT EPIRB FLOAT-FREE.
Lifesaving
Issued 16 April 1992
Resolved
PROVIDE TWO QUICK RELEASE FLOATING ORANGE SMOKE SIGNALS.
Navigation
Issued 16 April 1992
Resolved
PROVIDE ALL NECESSARY PUBS/CHARTS FOR INTENDED SERVICE AREA.
Navigation
Issued 16 April 1992
Resolved
UPDATE COMPASS DEVIATION CARD.
Documentation
Issued 16 April 1992
Resolved
SHOW LICENSES FOR REQUIRED CREW.
Lifesaving
Issued 16 April 1992
Resolved
PROVIDE SIX ADDITIONAL EXPOSURE SUITS FOR A TOTAL OF FIFTEEN.
Engineering
Issued 16 April 1992
Resolved
SHOW PROPER OPERATION OF SHAFT TACHOMETERS.
Accommodation/Occupational Safety
Issued 16 April 1992
Resolved
HYDROSTATICALLY TEST BOTH AIR RECEIVERS TO 1 1/4 MAWP.
Engineering
Issued 16 April 1992
Resolved
SUBMIT FOR APPROVAL VITAL SYSTEM AUTOMATION TEST PROCEDURES.
Accommodation/Occupational Safety
Issued 24 September 1990
Resolved
SECURE WASHER AND CLOTHES DRYER.
Lifesaving
Issued 24 September 1990
Resolved
ADD MISSING LINE FOR LINE THROWING GUN.
Accommodation/Occupational Safety
Issued 24 September 1990
Resolved
REPAIR BROKEN TOILET (MAIN DECK) AND INSTALL PROPER TYPE SEAT ON TOILET NEXT TO IT.
Fire Fighting
Issued 24 September 1990
Resolved
SERVICE B-5 SEMI-PORTABLE FIRE EXTINGUISHER.
Navigation
Issued 24 September 1990
Resolved
INSTALL PROPER TYPE LENS FOR AFT ANCHOR LIGHT.
Deck/Cargo
Issued 24 September 1990
Resolved
REPAIR INOPERATIVE STBD FUEL OIL SHUT OFF REACH ROD.
Fire Fighting
Issued 24 September 1990
Resolved
REPAIR LEAKING/FROZEN VALVE ON FIRE MAIN LINE.
Electrical
Issued 24 September 1990
Resolved
INSTALL PROPER LID FOR BATTERY BOX FOR PORT GENERATOR.
Engineering
Issued 24 September 1990
Resolved
REMOVE ALL EXCESS OIL AND SLUDGE FROM BILGES.
Electrical
Issued 24 September 1990
Resolved
REPAIR INOPERATIVE CONTROL BOX FOR DIRTY OIL PUMP AND REMOVE SHUT DOWN SWITCH.
Construction/Loadline
Issued 4 March 1984
Resolved
MAKE PERMANENT REPAIRS TO HOLED HULL IN WAY OF STARBOARD BOW
Deck/Cargo
Issued 5 October 1981
Resolved
PROVIDE STABILITY LETTER REFLECTING READMEASURED TONNAGES PRIOR TO CARRIAGEOF DRILLING FLUIDS IN # 1&2 PORT AND STARBOARD CARGO TANKS.
Casualty record · 1
6 January 2014Routine · role: Involved in a Marine Casualty · activity 4778480
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.