Records from 1982 to 2016. Most recent: inspection, 28 October 2016.
Inspection history · 53
28 October 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6031221
2 October 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4998022
12 May 2014
Type not recorded
No type recorded · Station Sandy Hook · USCG Northeast District (CGD-NE) · Activity 4858012
10 May 2014
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 4855422
9 May 2014
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 4854866
9 May 2014
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 4854896
15 March 2007
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2888597
25 May 2006
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2658580
12 July 2005
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2424476
13 June 2005
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2389607
5 May 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2350175
16 September 2004
Deficiency Check · Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2197990
28 May 2003
Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1804076
5 May 2003
Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1793673
20 December 2002
Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1721488
6 December 2001
Examination of Repairs
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1417422
25 June 2001
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1465669
4 May 2001
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1423552
27 April 2000
COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1384347
24 August 1999
Plan Review "T" Boat · Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1411822
19 May 1998
Drydock Extension · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1411704
2 October 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1457542
20 May 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1107515
17 April 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1453348
22 March 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1136062
17 November 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1447400
21 April 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 856938
5 April 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 853368
29 June 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1155796
10 June 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 838074
20 April 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1139209
13 April 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1144761
1 April 1993
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462338
24 November 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 828074
12 June 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 887106
21 August 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1238921
7 June 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 910531
28 August 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1033239
17 July 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1210108
22 June 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 887175
1 June 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1350800
26 April 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 899230
4 April 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1349585
17 June 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1310471
19 May 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1027875
2 September 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1019968
30 May 1986
Credit Drydock
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 998483
25 June 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987668
11 March 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 980536
11 March 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1287182
7 August 1984
Type not recorded
No type recorded · MSO CINCINNATI · Activity 980710
24 July 1984
Type not recorded
No type recorded · MSO CINCINNATI · Activity 980689
29 June 1982
Type not recorded
No type recorded · MSO CINCINNATI · Activity 976021
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 March 2007
No resolution recorded
Return expired COI to SLIS.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Electric Supply System (service) › Cable
Issued 25 May 2006
Resolved
Remove/ Rewire electrical boat cable running thru access door on the top deck portside.
Due 1 June 2006
Resolved 31 May 2006
Resolution: Cable has been rerouted
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 25 May 2006
Resolved
Repair/ repalce broken Paddles on paddle wheel (both port and starboard)
Due 1 June 2006
Resolved 31 May 2006
Resolution: Broken Paddles have been replaced
Lifesaving › Lifefloat › Markings
Issued 13 June 2005
Resolved
Relabel capacity.
Due 30 June 2005
Resolved 12 July 2005
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 13 June 2005
Resolved
Relabel and replace retro as needed.
Due 30 June 2005
Resolved 12 July 2005
Lifesaving › Lifefloat › Lifeline
Issued 13 June 2005
Resolved
Replace line from weak link to waterlights for all 3 lifefloats.
Due 30 June 2005
Resolved 12 July 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2005
Resolved
Remove all dead ended wires throughout the vsl.
Due 13 July 2005
Resolved 18 May 2006
Resolution: Wires have been removed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 June 2005
Resolved
Eliminate through hull fitting in watertight bulkhead compartment 2 b/n compartment 2 and 3.
Due 30 June 2005
Resolved 12 July 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 June 2005
Resolved
Replace extinguished emergency lights in galley area and main psngr area fwd of head.
Due 13 July 2005
Resolved 12 July 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 13 June 2005
Resolved
Replace light covers in port and strbd heads.
Due 13 July 2005
Resolved 12 July 2005
Engineering › Bilge Water Management System › Pump
Issued 13 June 2005
Resolved
Prove proper operation of bilge pump in compartment 5 and 6 and log official statement in log book.
Due 14 June 2005
Resolved 14 June 2005
Resolution: O/O called and confirmed via phone and also ordered an additional pump to carry onboard.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 13 June 2005
Resolved
Provide plans for approval of new AC system, including list of materials and one line diagram of wiring.
Due 13 July 2005
Resolved 18 May 2006
Resolution: A/C system has been installed as original
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2005
Resolved
Remove tape and pressure fit connection for high level water alarm in forepeak.
Due 30 June 2005
Resolved 12 July 2005
Engineering › Bilge Water Management System › Not Operational
Issued 5 May 2005
Resolved
Prove proper operation of forepeak bilge alarm.
Condition: Improper/Lack of Maintenance
Due 28 May 2005
Resolved 13 June 2005
Engineering › Bilge Water Management System › Eductor
Issued 5 May 2005
Resolved
Install bilge suction strainer in void #3.
Condition: Unknown
Due 28 May 2005
Resolved 13 June 2005
Construction/Loadline › Structures › Manhole
Issued 5 May 2005
Resolved
Prove watertighness of forepeak manhole plate.
Condition: Improper/Lack of Maintenance
Due 28 May 2005
Resolved 13 June 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 5 May 2005
Resolved
Repair light fixtures around exterior of house as needed.
Condition: Improper/Lack of Maintenance
Due 28 May 2005
Resolved 13 June 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 September 2004
Resolved
Post COI visible to passengers.
Due 17 October 2004
Resolved 13 June 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 16 September 2004
Resolved
Log drills and instructions.
Due 17 October 2004
Resolved 13 June 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 16 September 2004
Resolved
Provide means to convey passenger count to Coast Guard.
Due 17 October 2004
Resolved 13 June 2005
Resolution: Installed mailbox to maintain psngr count on dock.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 16 September 2004
Resolved
Replace retro reflective material on life jackets as needed.
Due 17 October 2004
Resolved 12 July 2005
Lifesaving › Lifefloat › Painter
Issued 16 September 2004
Resolved
Replace painter and weak link.
Due 17 October 2004
Resolved 13 June 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 16 September 2004
Resolved
Ensure portable fire extinguishers are tested IAW NFPA 10.
Due 17 October 2004
Resolved 13 June 2005
Resolution: Current servicing tag and in the green.
Engineering › Bilge Water Management System › Manifold
Issued 16 September 2004
Resolved
Provide bilge and fire system diagram.
Due 17 October 2004
Resolved 13 June 2005
Resolution: Color coded system.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 September 2004
Resolved
Label panel board boxes.
Due 17 October 2004
Resolved 13 June 2005
Resolution: Pen and ink.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 16 September 2004
Resolved
Add lagging around exhaust piping.
Due 17 October 2004
Resolved 13 June 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 16 September 2004
Resolved
Secure bilge alarm.
Due 17 October 2004
Resolved 13 June 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 September 2004
Resolved
Vessel failed to arrange for annual exam by due date.
Due 16 September 2004
Resolved 16 September 2004
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 28 May 2003
Resolved
Provide adequate covers for E/R batteries. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Unknown
Due 17 October 2004
Resolved 13 June 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 28 May 2003
Resolved
Provide guards for engine room lighting as needed. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 2 July 2003
Resolved 16 September 2004
Resolution: Sighted plastic covers on lights.
Electrical
Issued 25 June 2001
Resolved
Remove extension cords from garbage disposal and ice cream cooler.
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Documentation
Issued 25 June 2001
Resolved
Obtain FCC Safety Radio Certificate
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Lifesaving
Issued 25 June 2001
Resolved
Equip 3rd 22 person life float with a waterlight and a painter meeting 46 CFR 180.137
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Construction/Loadline
Issued 25 June 2001
Resolved
Equip bilge suctions with strainers meeting 46 CFR 182.510
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Engineering
Issued 25 June 2001
Resolved
Repair hydraulic leak on Fwd/Reverse valve
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Construction/Loadline
Issued 25 June 2001
Resolved
Submit repair proposal for wasted areas of hull plate
Condition: Unknown
Due 1 November 2001
Resolved 10 July 2002
Electrical
Issued 25 June 2001
Resolved
Remove dead ended wire from E/R
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Engineering
Issued 25 June 2001
Resolved
Lag engine exhaust
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Engineering
Issued 25 June 2001
Resolved
Prove proper operation of fuel shutoff valve
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Fire Fighting
Issued 25 June 2001
Resolved
Remove plastic trash cans
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Lifesaving
Issued 25 June 2001
Resolved
Mount lifejacket donning instructions
Condition: Unknown
Due 25 July 2001
Resolved 10 July 2002
Documentation
Issued 27 April 2000
Resolved
COMPLETE OUTSTANDING CG-835'S NO'S 5,6,16,17 FROM CG-835, CASE#MI99005538.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Fire Fighting
Issued 27 April 2000
Resolved
PROVIDE A PROPER TYPE FIRE-EXTINGUISHER BRACKET FOR THE B-1 FIRE EXTINGUISHER ON THE BRIDGE.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Documentation
Issued 27 April 2000
Resolved
COMPLY WITH THE REQUIREMENTS OF THE DRUG AND ALCOHOL PROGRAM.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 27 April 2000
Resolved
PROVIDE A 6" HIGH COAMING FOR THE PORT AND STARBOARD HATCHES. VESSEL IS RESTRICTED TO PROTECTED WATERS UNTIL SUCH TIME THAT THE COAMING HEIGHTS ARECHANGED.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Accommodation/Occupational Safety
Issued 27 April 2000
Resolved
PROPERLY SECURE WARMER IN THE GALLEY.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Lifesaving
Issued 27 April 2000
Resolved
PROVIDE ONE ADDITIONAL TYPE ONE PFDS. VESSEL IS RESTRICTED TO 142 TOTAL PERSONS O A RIVERS ROUTE.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Fire Fighting
Issued 27 April 2000
Resolved
PROVE PROPER OPERATION OF FIRE PUMP.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 27 April 2000
Resolved
INSTALL CAP FOR MDE SEA SUCTION AND VENT.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 27 April 2000
Resolved
REPAIR LEAKING SEA STRAINER.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Engineering
Issued 27 April 2000
Resolved
INSTALL AND PROVE PROPER OPERATION OF THE REMOTE FUEL VALVE FOR DIESEL GENERATOR.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Electrical
Issued 27 April 2000
Resolved
REMOVE PORTABLE BATTERY CHARGERS.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 24 August 1999
Resolved
REMOVE PVC DRESSER COUPLING FROM BILGE PIPE IN ENGINEROOM AND MAKE PROPER AND PERMANENT REPAIRS.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Construction/Loadline
Issued 24 August 1999
Resolved
LABEL ALL HIGH LEVEL BILGE ALARMS.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Engineering
Issued 24 August 1999
Resolved
PROVIDE SHIELD AROUND HYDRAULIC PADDLWHEEL MOTOR FOR STBD PADDLEWHEEL.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Lifesaving
Issued 24 August 1999
Resolved
PROVE COMPLIANCE WITH CHEMICAL TESTING REQUIREMENTS OF 46 CFR.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Lifesaving
Issued 24 August 1999
Resolved
CONDUCT REQUIRED EMERGENCY DRILL IN PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Electrical
Issued 24 August 1999
Resolved
LABEL ALL ELECTRICAL BREAKERS & PROVIDE DIRECTORY IN DISTRIBUTION PANELS.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Lifesaving
Issued 24 August 1999
Resolved
PROVIDE PROPER NUMBER OF PFDs AS NOTED ON COI.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Construction/Loadline
Issued 24 August 1999
Resolved
PROVIDE PROPER HULL MARKINGS, I.E. DRAFT MARKS, VESSEL NAME.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Engineering
Issued 24 August 1999
Resolved
ENSURE ALL HYDRAULIC, FUEL, AND COOLING FLEX HOSES ARE DOUBLE CLAMPED ON EACH END.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Lifesaving
Issued 24 August 1999
Resolved
PROVIDE REQUIRED EQUIPMENT FOR ALL LIFEFLOATS.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Construction/Loadline
Issued 24 August 1999
Resolved
ENSURE ALL BULKHEAD PENETRATIONS ARE WATERTIGHT.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Lifesaving
Issued 24 August 1999
Resolved
ENSURE ALL RING BUOYS, PFDs, & SURVIVAL CRAFT ARE MARKED AND STOWED IAW 46 CFR 180.70 - 180.137.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Engineering
Issued 24 August 1999
Resolved
PROPERLY INSULATE EXHAUST STACKS ON UPPER DECK.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Accommodation/Occupational Safety
Issued 24 August 1999
Resolved
REPLACE ALL BROKEN WINDOWS ON MAIN DECK.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Fire Fighting
Issued 24 August 1999
Resolved
PROVIDE FIRE HOSES IAW 46 CFR 181.320(b)(1-3).
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Accommodation/Occupational Safety
Issued 24 August 1999
Resolved
PROVIDE SYSTEM TO PREVENT SUDDEN CLOSURE OF STAIRWELL DOOR DURING VESSEL MOVEMENT (TURN TO PORT).
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Lifesaving
Issued 24 August 1999
Resolved
PROVE ABILITY TO SAFELY AND EFFECTIVELY RECOVER VICTIM IN WATER USING RESCUE PLATFORM.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Fire Fighting
Issued 19 May 1998
Resolved
Prior to getteing underway with passengers, service all expired (3) fire extinguishers.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Electrical
Issued 19 May 1998
Resolved
Provide portable battery lights at bridge and engine room.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
Install lifejacket donning instructions.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
Prior to getting underway with passengers, prove proper operation of vesselP/A system.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Electrical
Issued 19 May 1998
Resolved
Remove extension cord from galley air vent.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Electrical
Issued 19 May 1998
Resolved
Remove dead-end wire from 01 deck bar.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Engineering
Issued 19 May 1998
Resolved
Ensure proper operation of bridge amp and oil temp gauge.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Electrical
Issued 19 May 1998
Resolved
Properly secure and cover batteries in engine room.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Electrical
Issued 19 May 1998
Resolved
Remove extension cord from light in sewage space overhead.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
Ensure first aid kit meets requirements of sub chapter "Q" 160.041.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
Replace all expired (6) flares.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Construction/Loadline
Issued 19 May 1998
Resolved
Proir to getting underway with passengers, prove proper operation and knowledge of bilge system.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
Ensure access (PFD's were covering) to remote fuel shut off valve.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Construction/Loadline
Issued 19 May 1998
Resolved
Properly label #1 void bilge remote rod.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Documentation
Issued 2 October 1997
Resolved
PROVIDE THIS OFFICE THE MOST RECENT STABILITY LETTER.
Condition: Unknown
Due 10 October 1997
Resolved 2 March 1998
Electrical
Issued 2 October 1997
Resolved
Properly adjust interior lighting to proper clearance from window curtains.
Condition: Unknown
Due 28 October 1997
Resolved 2 March 1998
Fire Fighting
Issued 17 April 1997
Resolved
PROVIDE PROTECTIVE GUARD FOR BELT AND PULLEY SYSTEM FOR AUXILIARY FIRE PUMPAND HYDRAULIC STEERING PUMP
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 17 April 1997
Resolved
PROVIDE NEW VESSEL NAME FOR ALL LIFE JACKETS AND REPLACE ALL WORN RETROREFLECTIVE TAPE.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Construction/Loadline
Issued 17 April 1997
Resolved
MAKE WATERTIGHT THE BULKHEADS BETWEEN #1 AND #2 VOIDS, #2 AND #3 VOIDS, ENGINEROOM AND #5 VOID AND #5 AND #6 VOIDS. (OLD THRU-HULL FITTINGS NEED TO BE CAPPED)
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Construction/Loadline
Issued 17 April 1997
Resolved
PROVIDE WATERTIGHT CAP FOR OLD AC DRAIN PIPE IN FOREPEAK, PORT SIDE
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
REMOVE OLD ELECTRICAL WIRES FROM FOREPEAK VOID.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Accommodation/Occupational Safety
Issued 17 April 1997
Resolved
PROPERLY SUPPORT WATERLINES IN #3 VOID_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 17 April 1997
Resolved
VESSEL IS LIMITED TO THE CARRIAGE OF 127 ADULT PASSENGERS UNTIL REPAIRS AREMADE TO NECK STRAPS ON 17 ADULT LIFE JACKETS AND 8 NEW LIFEJACKETS ARE PROVIDED.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHT IN GALLEY
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
RECONNECT CONDUIT ON BOTTOM OF CROSS OVER CONTROL.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
PROVIDE PROTECTIVE GLOB ON STBD SIDE OF ENGINE ROOM, TIGHTEN PROTECTIVE GLOBE ON PORT SIDE OF ENGINE ROOM.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
PROVIDE ELECTRICAL BOX CONNECTIONS FOR EXHAUST FAN IN ENIGINE ROOM.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
PROPERLY SECURE BATTERIES IN ENGINE ROOM.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
REMOVE WIRES FROM OLD SEWAGE PUMP INSTALLATION IN #3 VOID
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
PROPERLY SECURE ELECTRICAL BOX COVERS IN #3 AND #5 VOIDS.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 17 April 1997
Resolved
PROPERLY FILL OUT DIRECTORY CARD IN ELECTRICAL BOX IN ENGINEROOM
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Accommodation/Occupational Safety
Issued 17 April 1997
Resolved
PROVE PROPER OPERATION OF PUBLIC ADDRESS SYSTEM
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 17 April 1997
Resolved
PROVIDE LIFERING WITH VESSEL'S NAME AND PROPERLY ATTACH WATER LIGHT.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 22 March 1995
Resolved
REPLACE WASTED AND MISSING ADULT SIZE PFDs WITH PROPER, APPROVED ADULT SIZEPFDs. VESSEL LIMITED THE NOT MORE THAN 128 ADULT ON BOARD UNTIL CORRECTED.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995
Resolved
PROVIDE PROTECTIVE GLOBES FOR EXTERIOR LIGHTS.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Documentation
Issued 22 March 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995
Resolved
PROVIDE ELECTRICAL RECEPTACLE BOX FOR GALLEY EXHAUST FAN.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995
Resolved
PROVIDE GUARD FOR GALLEY EXHAUST FAN BLADES.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995
Resolved
PROVE OPERATION OF EMERGENCY EXIT LIGHTING.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Fire Fighting
Issued 22 March 1995
Resolved
DEMONSTRATE AN EFFECTIVE FIRE-FIGHTING STREAM OF WATER FROM BOTH FIRE STATIONS.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995
Resolved
PROVIDE GUARD FOR POWER EXHAUST FAN BLADES IN ENGINE ROOM, PORT SIDE.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995
Resolved
PROVIDE PROTECTIVE COVERS FOR BATTERIES IN ENGINE ROOM.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995
Resolved
INSTALL LIGHT BULB AND PROTECTIVE GLOBE IN WHERE MISSING IN ENGINE ROOM OVERHEAD FIXTURE IN FWD PORT CORNER.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Lifesaving
Issued 22 March 1995
Resolved
CONDUCT EMERGENCY DRILLS WITH FULL CREW COMPLEMENT IN PRESENCE OF USCG MARINE INSPECTOR PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Lifesaving
Issued 5 April 1994
Resolved
AMEND EMERGENCY CHECK OFF LIST TO REFLECT THE USE OF DECKHAND TO ASSIST PASSENGERS AT SECOND DECK FWD ESCAPE ROUTE PER SLMMS LTR DTD 02FEB94.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Electrical
Issued 5 April 1994
Resolved
PROVIDE COVERS FOR 12 VOLT BATTERIES IN ENGINEROOM.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Lifesaving
Issued 5 April 1994
Resolved
REMOVE TRIPPING HAZARD FROM FORWARD SECOND DECK ESCAPE ROUTE.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Lifesaving
Issued 5 April 1994
Resolved
REPLACE LINE ON RING BUOY.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Fire Fighting
Issued 1 April 1993
Resolved
PROVIDE PROOF OF SATISFACTORY ANNUAL SERVICING OF BI AND BII MAIN DECK FIREEXTINGUISHER.
Condition: Unknown
Due 1 May 1993
Resolved 13 April 1993
Documentation
Issued 1 April 1993
Resolved
PROVIDE PROOF OF ENROLLMENT IN EMPLOYEE ANNUAL RANDOM DRUG/CHEMICAL TESTING.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Lifesaving
Issued 1 April 1993
Resolved
PROVIDE 7 ADDITIONAL APPROVED ADULT PFDS TO BRING TOTAL ON BOARD TO 152.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Documentation
Issued 1 April 1993
Resolved
POST VALID FCC STATION LICENSE.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Electrical
Issued 1 April 1993
Resolved
PROVE PROPER OPERATION OF SHIP'S GENERATOR SET.
Condition: Unknown
Due 1 May 1993
Resolved 13 April 1993
Engineering
Issued 7 June 1990
Resolved
PROVIDE FUEL SHUT OFF VALVE AT MAIN ENGINE.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Electrical
Issued 7 June 1990
Resolved
CLEAN BATTERY BOX AND BLOCK BATTERIES TO KEEP THEM FROM SHIFTING.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Engineering
Issued 7 June 1990
Resolved
REPLACE MISSING HAND WHEEL ON BILGE SYSTEM.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Navigation
Issued 7 June 1990
Resolved
REPLACE BROKEN PADDLE ON PORT AND STARBOARD WHEELS.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Accommodation/Occupational Safety
Issued 7 June 1990
Resolved
INSTALL SCREEN ON WATER TANK VENTS.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Lifesaving
Issued 7 June 1990
Resolved
STENCIL VESSEL NAME ON RING BUOY
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Lifesaving
Issued 7 June 1990
Resolved
PROVIDE 6 ORANGE FLARES.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Fire Fighting
Issued 7 June 1990
Resolved
PROVIDE 3 APPROVED B-II FIRE EXTINGUISHER BRACKETS.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Documentation
Issued 1 June 1989
Resolved
POST STABILITY LETTER IN WHEELHOUSE.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Navigation
Issued 1 June 1989
Resolved
SHOW PROPER STERN NAVIGATION LIGHT.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Engineering
Issued 4 April 1989
Resolved
TEST FIXED BILGE PUMP & SYSTEM IN PRESENCE OF MARINE INSPECTOR FOR BOW VOID.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Navigation
Issued 4 April 1989
Resolved
SHOW PROPER STERN NAVIGATION LIGHT.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 4 April 1989
Resolved
PROVIDE SIX SMOKE FLARES AND WATERTIGHT CONTAINER.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Documentation
Issued 4 April 1989
Resolved
POST STABILITY LETTER IN WHEELHOUSE.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 4 April 1989
Resolved
PROVIDE 78 ADULT LIFE PRESERVERS. TYPE I USCG APPROVED. NUMBER OF TOTAL PERSONS REQUIRED LIMITED TO 82.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 4 April 1989
Resolved
RENEW GRAB LINE TO RING BUOY.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Lifesaving
Issued 4 April 1989
Resolved
PROVIDE SEPARATE STOWAGE FOR CHILD LIFE PRESERVERS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Fire Fighting
Issued 4 April 1989
Resolved
PROVIDE 3 B-II FIRE EXT TO BE PROPERLY MOUNTED ON REQUIRED BRACKETS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Fire Fighting
Issued 4 April 1989
Resolved
PROVIDE HAND FIRE PUMP WITH FIRE HOSE CONNECTION FOR FIRE HOSE.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Fire Fighting
Issued 4 April 1989
Resolved
PROVIDE (2) 5/8" GARDEN HOSES FOR FIRE FIGHTING. .
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Engineering
Issued 4 April 1989
Resolved
PROVIDE BELT GUARDS FOR MAIN ENGINES.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Engineering
Issued 4 April 1989
Resolved
LABEL FUEL OIL SHUT-OFF IN PASSAGEWAY.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
PROVIDE BATTERY BOX COVER.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
CORRECTLY LABEL ALL SWITCHBOARDS AND PANEL BOARDS (ENGINEROOM, WHEELHOUSE, ETC.)
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Electrical
Issued 4 April 1989
Resolved
REMOVE WIRE NUTS IN JUNCTION BOXES AND PROVIDE CRIMP CONNECTIONS.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Construction/Loadline
Issued 11 March 1985
Resolved
PROPERLY MARK THE VESSEL'S HULL WITH VESSEL NAME, DRAFT MARKS AND HAILING PORT.
Condition: Unknown
Due 11 March 1985
Resolved 11 March 1985
Engineering
Issued 29 June 1982
Resolved
PROPERLY INSULATE THE ENGINE EXHAUST PIPE.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Engineering
Issued 29 June 1982
Resolved
ADEQUATELY STABILIZE THE FUEL OIL RETURN LINE FROM THE MAIN ENGINE.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Accommodation/Occupational Safety
Issued 29 June 1982
Resolved
MAKE REPAIRS AS NECESSARY TO MAKE THE BASIN IN THE MEN'S HEAD OPERABLE.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Construction/Loadline
Issued 29 June 1982
Resolved
PROVIDE A SHUT OFF VALVE ON ALL LINES FROM THE FORWARD SEA CHEST STARBOARD SIDE.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Construction/Loadline
Issued 29 June 1982
Resolved
LABEL ALL BILGE VALVES AT THE ENGINE ROOM MANIFOLD.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Engineering
Issued 29 June 1982
Resolved
REPLACE THE PULLEY GUARD ON THE MAIN ENGINE.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Construction/Loadline
Issued 29 June 1982
Resolved
MAKE BULKHEAD PENETRATIONS FOR STEERING SYSTEM HYDRAULIC LINES WATERTIGHT IN ALL BULKHEADS.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Construction/Loadline
Issued 29 June 1982
Resolved
REPLACE THE SCREEN FOR THE STEERING ROOM BILGE SUCTION.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Construction/Loadline
Issued 29 June 1982
Resolved
PROVIDE ACCESS TO THE FOREMOST COMPARTMENT TO FACILITATE INSPECTION OF THE SPACE.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Engineering
Issued 29 June 1982
Resolved
PROVIDE A HEAT RESISTANT FUEL OIL FILTER ON THE MAIN ENGINE FUEL OIL SUPPLY
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Engineering
Issued 29 June 1982
Resolved
PROPERLY MARK THE REMOTE FUEL SHUT-OFF VALVE FOR THE MAIN ENGINE.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Navigation
Issued 29 June 1982
Resolved
REMOVE ALL PINS FORM THE RUDDER POST AND MAKE AVAILABLE THE RUDDER SYSTEMS FOR A THROUGH INSPECTION.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982
Construction/Loadline
Issued 29 June 1982
Resolved
PROPERLY REPAIR THE SMALL HOLE IN THE COLLISION BULKHEAD JUST FORWARD OF THE AIR RECEIVER.
Condition: Unknown
Due 29 June 1982
Resolved 29 June 1982