MAURY USCG vessel records
← All vessels

WHALE WATCHER

Built
1999
Last inspected
22 June 2026
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK8294
486675
Flag
UNITED STATES
Maury page id
psix-486675

Documentation record

Registered dimensions (L × B × D)106.4 ft × 28.0 ft × 11.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)106.4 ft × 28.0 ft × 11.8 ft
ITC tonnagegross 315 / net 129
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBARNSTABLE, MA
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it315 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
129 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

22 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8410167
26 March 2026 Examination of Repairs · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8332369
24 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8165480
3 March 2025 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8085101
17 October 2024 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8020421
20 June 2024 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7938439
15 April 2024 Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7892483
11 October 2023 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7806797
2 May 2023 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7676186
14 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644549
19 September 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7560391
26 April 2022 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7436077
21 March 2022 Deficiency Check · Examination of Repairs · Plan Review (Other than "T")
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7409401
6 October 2021 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7327661
5 March 2021 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7128866
10 July 2020 MTSA Verification · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7002495
24 June 2019 DAPI Audit · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6720912
14 March 2019 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6638636
22 May 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6420629
7 May 2018 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6405851
2 May 2017 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6134568
23 February 2017 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6088957
19 May 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5884383

Deficiency record · 11

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 June 2024 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. The vessel is currently combining the logs for drills, EPIRB and security in one log book. Vessel to create a separate crew drills and monthly EPIRB test log readily available for USCG inspection. Security log is to be kept secured along with the security plan. 46CFR 122.728.c.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 8 July 2024
Resolution: Log created and seperated from the security drill log.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2024 Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard and, if accessible from the rear, on the deck in the rear of the switchboard. Vessel is missing the required matting in front of the ships main switchboard. Provide IAW regulation to the attending USCG MI. 46CFR 120.330.g.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 8 August 2024
Resolution: Mat provided
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 20 June 2024 Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval. Vessels originally MSC and USCG MI approved DVTP's have undergone changes made by the manufacture's servicing/installation technician. Owner to re-submit updated DVTP's to MSC for review with OCMI in copy. 46CFR 61.40-1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 8 August 2024
Resolution: DVTP's resubmitted.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 2 May 2023 Resolved
Vessel's restricted areas were not labeled correctly. Restricted areas shall be: Clearly mark all restricted areas and indicate that access to the area is restricted and that unauthorized presence within the area constitutes a breach of security.33CFR104.207
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2023
Resolution: Received an email with pictures of signs posted
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 May 2023 Resolved
Exercises must be conducted at least once each calendar year, with no more than 18 months between exercises. No exercise has been completed with in the past 18 months.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2023
Resolution: Received an email with completed exercise
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 May 2023 Resolved
The Vessel Security Officer must keep records of the activities as set out in paragraph (b) of this section for at least 2 years and make them available to the Coast Guard upon request. Vessel does not have any records required by 33CFR104.235
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2023
Resolution: Received an email with required records
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2022 Resolved
MTSA Annual Audit is missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 20 June 2024
Resolution: Audit reviewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 April 2022 Resolved
All microprocessor or computer based system must meet the requirements of part 62 in subchapter F of this chapter. Section 6.8, for Handheld Remote Joystick of approved DVTPs were not conducted. Conduct section 6.8 DVTPs once equipment is installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2022
Resolved 8 July 2022
Resolution: DVTPs completed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 April 2022 Resolved
All microprocessor or computer based system must meet the requirements of part 62 in subchapter F of this chapter. During process of conducting DVTPs, found errors with procedures/results. Amend DVTPs to show correct procedures/results and resubmit to MSC for approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2022
Resolved 20 June 2024
Resolution: Item has been rewritten for clarification.
Electrical › Electric Generation Source (service) › Conductor
Issued 7 May 2018 Resolved
Vessel installed new wiring for the SSDGs. Provide electrical drawing, specifications, and data for the new wring installation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 22 May 2018
Resolution: Vessel rep provided details on the wiring for the SSDG.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 7 May 2018 Resolved
Vessel does have test procedures for testing electrical controls of the vessel's propulsion controls. Provide test procedures for the main engines.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 22 May 2018
Resolution: Owner provided PSTP and they have been uploaded to MISLE documents

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.