MAURY USCG vessel records Sign in
← All vessels

SEA LION

SEA LION is a 1976 industrial vessel. The Coast Guard has recorded 52 inspections since 1990, most recently in January 2009, along with 82 deficiencies — 3 with no resolution recorded — and 2 casualty investigations in 2008.

Records from 1990 to 2009. Most recent: inspection, 20 January 2009.

Built
1976
Last inspected
20 January 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7641059 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBY5965
Flag
UNITED STATES
338546000 (licence lapsed)
Maury page id
psix-48692

Inspections, by type

…with no type recorded14
…past their stated due date3
Years with a record 20 calendar years (1990–2009)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it1087 - Convention (Subpart B), Gross Ton
464 - Regulatory (Subpart C or D), Gross Ton
326 - Convention (Subpart B), Net Ton
315 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBY5965MMSI 338546000 · expired · compulsorily equipped · granted 2 August 2008, cancelled 20 October 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 52

20 January 2009 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3397078
18 December 2008 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3382283
12 November 2008 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3362905
11 November 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3510931
23 July 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3277077
14 July 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3267895
20 May 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3212651
10 April 2008 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3181495
8 April 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3179773
18 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3132834
19 July 2007 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3000711
16 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2750060
2 May 2006 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2634664
17 January 2006 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2568238
20 June 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2396789
7 March 2005 MARPOL Annex I Examination · COI Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2296816
8 March 2004 Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2020709
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972327
20 August 2003 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1881653
18 April 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1775996
8 May 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1614368
3 April 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427959
16 March 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406671
24 June 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397196
22 February 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411814
3 November 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 675789
1 November 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 43293
7 August 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 82866
16 July 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471988
25 September 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431853
1 August 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451090
18 May 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427070
14 October 1994 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446126
8 October 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 35139
20 May 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354789
19 March 1994 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 855734
4 February 1994 Permit to Proceed · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464491
30 November 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 842459
17 November 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 839750
27 October 1993 Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1141109
28 October 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938580
28 August 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263780
25 August 1992 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1261798
9 September 1991 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1247277
13 August 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938746
17 May 1991 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1260110
5 August 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 929053
27 July 1990 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 903200
14 July 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 913597
7 July 1990 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1244777
11 June 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 910926
11 June 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1229650

Deficiency record · 82

Construction/Loadline › Hull › Bottom Plating
Issued 21 November 2008 No resolution recorded
Proceed directly to Bollinger Shipyard in Amelia, LA to effect permanent repairs to damaged bottom shell plating IWO port and STBD bow thruster tunnel.
Action required: 705 - Other - as specified
Due 24 November 2008 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Pipe Flange
Issued 21 November 2008 No resolution recorded
Re-pack all cable and piping penetrations on the FWD engine room watertight bulkhead and test.
Action required: 705 - Other - as specified
Due 21 December 2008 — due date passed with no resolution recorded
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 November 2008 No resolution recorded
Properly repair switchboard and prove proper operation.
Action required: 705 - Other - as specified
Due 21 December 2008 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 April 2008 Resolved
Breakers on Main Switchboard in enginroom are not labeled. Label all breakers with name plate and rating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2008
Resolution: Labeled Main switchboard.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 7 April 2008 Resolved
Locking bar interlock for generator/ shoretie breakers does not fit properly. Replace existing bar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2008
Resolution: Replaced locking bar.
Communications › Internal Communications System › Sound-powered Telephone
Issued 7 April 2008 Resolved
Aft steering sound powered bell is missing and has exposed wires. Replace bell.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2008
Resolution: Had third party replace bell.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 April 2008 Resolved
Emergency lighting in bowthruster space and aftsteering not working. Repair or replace both fixtures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2008
Resolution: Replaced both emergency lights.
Lifesaving › Lifebuoys › Stowage
Issued 7 April 2008 Resolved
Lifebuoys are not stowed IAW life saving plan. Ensure all lifesaving equiptment is stowed IAW life saving plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2008
Resolution: Developed new lifesaving plan and ensured proper stowage of equiptment.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 April 2008 Resolved
Engineer not able to operate OWS. Prove proper operation of OWS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2008
Resolution: New engineer operated properly.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 16 August 2006 Resolved
Upon completion of WTD installation, update Fire Control Plan and submit for approval/signature to local OCMI.
Due 16 September 2006
Resolved 19 July 2007
Resolution: Bulkhead installation was not initiated as requested.
Fire Fighting › Fire Hydrants › Condition
Issued 18 April 2003 Resolved
Pipe leading through deck bulkhead was fractured.
Condition: Unknown
Due 18 April 2003
Resolved 18 April 2003
Resolution: Yard personnel cropped and renewed pipe leading to hydrant.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 April 2003 Resolved
Control box loctaed within starboard winch room was wasted due to service.
Condition: Design Flaw
Due 15 May 2003
Resolved 18 April 2003
Resolution: Vessel electrician replaced wasted box with new fiberglass box.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 18 April 2003 Resolved
Fuel vent flame screens on the port #1,2 fuel tanks, starboard day tank and #3 fuel tank were punctured.
Condition: Damaged By Earlier Event
Due 15 May 2003
Resolved 18 April 2003
Resolution: Vessel''s crew replaced wasted flame screens with brand new 30 X 30 mesh screens.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 18 April 2003 Resolved
Port captain was ddirected to install missing lent traps within laundry space.
Condition: Unknown
Due 15 May 2003
Resolved 18 April 2003
Resolution: Port captain provided inspector with drawings of lent traps currently being produced for vessel.
Fire Fighting › Ventilation Systems › Fans
Issued 18 April 2003 Resolved
Exhust/Inflow fan located within engine room was coated with excessive oil due to lack of cleaning.
Condition: Improper Installation
Due 25 April 2003
Resolved 18 April 2003
Resolution: Bollinger shipyard was on scene degreasing and pressure washing the duct system. Fan was also degreased and cleaned.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 8 May 2002 Resolved
PROVIDE APPROVED AUTOMATION TEST PROCEDURES. VESSEL MUST CARRY FULL CREW. LEGACY COMPONENT DESC: AUTOMATION TEST PROCEDURES
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 8 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 May 2002 Resolved
PREFORM 12 YEAR HYDROSTATIC TEST ON THREE EXTINGUISHERS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2002
Resolved 9 May 2002
Navigation › Piloting/Steering
Issued 8 May 2002 Resolved
PROVIDE AND POST EMERGENCY STEERING INSTRUCTIONS. LEGACY COMPONENT DESC: EMERGENCY STEERING INSTRUCTIONS
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 9 May 2002
Engineering › Bilge Water Management System
Issued 8 May 2002 Resolved
PERMANENTLY INSTALL BOW THRUSTER BILGE HIGH LEVEL ALARM SENSOR. LEGACY COMPONENT DESC: HIGH LEVEL SENSOR
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2002
Resolved 9 May 2002
Accommodation/Occupational Safety › Ventilation › General
Issued 8 May 2002 Resolved
CLEAN EXCESSIVE OIL RESIDUE FROM ENGINE ROO EXHAUST FAN AND RELOCATE CRANK CASE VENT HOSES. LEGACY COMPONENT DESC: EXHAUST FAN
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 8 March 2005
Resolution: Installed
Communications › Internal Communications System › Sound-powered Telephone
Issued 8 May 2002 Resolved
DEMONSTRATE ENGINE ROOM SOUND POWER PHONE VISUAL INDICATOR ON THE FINAL POWER SOURSE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 8 March 2005
Resolution: Installed
Lifesaving
Issued 16 March 2000 Resolved
DEMONSTRATE COMPLIANCE WITH D8 POLICY LETTER DATED 12NOV98 "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS", TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Lifesaving
Issued 24 June 1999 Resolved
REPAIR RESCUE BOAT FORWARD LIFTING EYE.
Condition: Unknown
Due 24 July 1999
Resolved 29 June 1999
Accommodation/Occupational Safety
Issued 25 September 1997 Resolved
CLEAN GALLEY STOVE HOOD AND REPLACE MISSING VENT FILTER FOR SAME.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Navigation
Issued 25 September 1997 Resolved
CALIBRATE RUDDER AND HELM INDICATOR (SPERRY) IN PILOT HOUSE.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Construction/Loadline
Issued 20 May 1994 Resolved
REPLACE BILGE FLOATS IN AFT PASSAGE AND ENGINE ROOM.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Accommodation/Occupational Safety
Issued 20 May 1994 Resolved
SECURE DEEP FAT FRYER.
Condition: Unknown
Due 23 May 1994
Resolved 28 June 1994
Fire Fighting
Issued 20 May 1994 Resolved
REPLACE FIRE DETECTOR OVER STBD MDE.
Condition: Unknown
Due 30 May 1994
Resolved 28 June 1994
Engineering
Issued 20 May 1994 Resolved
INSTALL AN APPROVED OWS.
Condition: Unknown
Due 1 July 1994
Resolved 20 July 1994
Engineering
Issued 20 May 1994 Resolved
PROVIDE APPROVED PLANS AND TEST PROCEDURES FOR THE AUTOMATED MONITORING/CONTROL SYSTEM IAW NAVIC 1-78.
Condition: Unknown
Due 1 July 1994
Resolved 20 July 1994
Fire Fighting
Issued 20 May 1994 Resolved
PROVIDE APPROVED PLANS FOR ENGINE ROOM HALON SYSTEM.
Condition: Unknown
Due 1 July 1994
Resolved 20 July 1994
Fire Fighting
Issued 20 May 1994 Resolved
INSTALL NEW FIRE MAIN PRESSURE GAUGE IN PILOT HOUSE.
Condition: Unknown
Due 30 May 1994
Resolved 20 July 1994
Navigation
Issued 20 May 1994 Resolved
INSTALL DUAL SOURCE AFT MASTHEAD LIGHT.
Condition: Unknown
Due 1 July 1994
Resolved 20 July 1994
Accommodation/Occupational Safety
Issued 20 May 1994 Resolved
INSTALL REMOTE SHUTDOWN FOR GALLEY STOVE VENT FAN.
Condition: Unknown
Due 1 July 1994
Resolved 20 July 1994
Documentation
Issued 20 May 1994 Resolved
PROVIDE A CARGO SHIP RADIOTELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 1 July 1994
Resolved 26 September 1994
Documentation
Issued 28 August 1992 Resolved
PROVIDE ON BOARD A BREATH TESTING DEVICE AND URINE SPECIMEN COLLECTION / SHIPPING KITS THAT MEET THE REQUIREMENTS OF BOTH 46 CFR 4.06-20 AND 46 CFR 16.330
Condition: Unknown
Due 3 November 1992
Resolved 3 November 1992
Electrical
Issued 17 May 1991 Resolved
PROVIDE COVERS FOR THE FOLLOWING ELECTRICAL POWER PANNELS, 2nd DECK A/C_x001C_ UNIT, GALLEY A/C UNIT, AND REEFER COMPRESSOR ROOM.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Documentation
Issued 17 May 1991 Resolved
SUBMITT STABILITY CALULATIONS FOR PRESENT VESSEL CONFIGURERATION FOR APPROVAL BY U.S.COAST GUARD FOR NEW STABILITY LETTER AND LOADING IMFORMATION.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Lifesaving
Issued 17 May 1991 Resolved
PROVIDE 16 ADDITIONAL LIFE JACKETS, INTEL ADDITIONAL JACKETS ARE PROVIDED _x001C_TOTAL PERSONS ALLOWED IS 17
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Fire Fighting
Issued 17 May 1991 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR FIX HALON SYSTEM INSTALLED FOR ENGINE ROOM.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Unknown
Issued 11 June 1990 Resolved
PROVIDE A NEW STABILITY LETTER TO REFLECT NEW VESSEL TONNAGE AND POST IN THE WHHELHOUSE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE CG APPROVED PLANS FOR THE INSTALLED ENGINE ROOM FIXED HALON SYSTEM AND TEST SATISFACTORILY NO LATER THAN 22 DEC 90 AND PRIOR TO REDUCING ENGINE ROOM MANNING.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE CG APPROVED PLAN FOR THE ENGINE ROOM FIXED FIRE DETECTION SYSTEM AND TEST SATISFACTORILY NO LATER THAN 22 DEC 90 AND PRIOR TO REDUCING ENGINE ROOM MANNING.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
HAVE VESSEL READMEASURED TO REFLECT NEW VESSEL TONNAGE DUE TO REMOVAL OF DECK HOUSE ON AFT DECK.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE SUITABLE FIRST AID SUPPLIES FOR THE HOSPITAL.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REPLACE GLASS COVER AND MINI HAMMER FOR EMERGENCY VENTILATION SHUTDOWN
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PERMANENTLY MOUNT ELECTRICAL AIR CONDITIONING JUNCTION BOX ON PORT SIDE AFT OF THE LIFERAFT STATION.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE A CG APPROVED FIRE CONTROL SAFETY PLAN AND PROPERLY POST ON THE VSL
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REMOVE ALL DEAD END WIRES FROM THE ENGINE ROOM.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REPLACE ALL PLASTIC WIRE TIES IN THE TUNNEL TO THE ENGINE ROOM WITH STEEL STRAPPING.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
ALL ACCOMODATIONS IN THE AFTER DECK HOUSE ARE TO BE CG INSPECTED PRIOR TO CARRYING PERSONS IN THE AFTER HOUSE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE A SUITABLE HOSPITAL/TREATMENT/ISOLATION ROOM.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROPERLY STENCILE ALL REACH RODS ON THE MAIN DECK.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PERMANENTLY SEAL ALL CABLEWAYS AND STUFFING TUBES THROUGHTHE AFTER BULKHEAD OF THE AFTER HOUSE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE VENTILATION TO THE OUTSIDE FOR THE GENERAL ALARM BATTERIES.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REPLACE EMERGENCY BATTERY COVERS.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE 3 ADDITIONAL CG APPROVED HAND HELD SMOKE SIGNALS.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE A WATERPROOF CONTAINER FOR ALL HANDL HELD DISTRESS SIGNALS.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REMOVE OIL NON-CG APPROVED SOLAS LIFERAFTS FROM THE VESSEL.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REPLACE ALL MISSING JUNCTION BOX COVERS THROUGH OUT THE VESSEL.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PERMANENTLY MOUNT ANCHOR WINDLASS SWITCH ON THE FOS'CLE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROPERLY SECURE THE NAVIGATION LIGHT ELECTRICAL CABLE ON THE FORWARD MAST.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE METAL LIGHT GUARD FOR LIGHT ON THE WEATHER DECK STARBOARD SIDE BETWEEN THE FORWARD AND AFTER HOUSE ON THE 01 LEVEL.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PERMANENTLY REPAIR ALL MAIN ENGINE GAUGES IN THE WHEEL HOUSE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
RE-WIRE PORT AND STARBOARD LIFERAFT LAUNCHING ILLUMINATION LIGHTS TO THE EMERGENCY POWER CIRCUIT.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REPACK/SEAL ALL LOOSE WIRES IN THE ENGINE ROOM AFTER BULKHEAD.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
POST VESSEL STABILITY LETTER IN THE PILOTHOUSE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REMOVE ALL DEADEND ELECTRICAL CABLES THROUGH THE AFTER BULKHEAD OF THE AFT HOUSE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE OPERABLE GENERAL ALARM BELLS IN THE AFT DECK HOUSE NO LATER THAN 11JUL 90 AND PRIOR TO CARRYING PERSONS IN THE AFT DECK HOUSE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REPLACE THE EXISTING RESCUE BOAT WITH A CG ACCEPTED RESCUE BOAT.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE 5 ADDITIONAL COAST GUARD APPROVED TYPE I PFD'S.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
CONDUCT A PITOT TUBE PRESSURE TEST OF THE FIRE MAIN SYSTEM.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVE OPERATIONAL BOTH MSD'S
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROPERLY MARK ENGINE ROOM GENERAL ALARM FLASHING LIGHT: GENERAL ALARM LIGHTWHEN LIGHT FLASHES GO TO YOUR STATION.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REPOSITION GENERAL ALARM FLASHING LIGHT IN THE ENGINE ROOM TO WHERE BEST SEEN THROUGH OUT THE ENGINE ROOM.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
INSTALL A GENERATOR SWITCH SAFETY BAR ON THE MAIN SWITCHBOARD.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
MAKE PERMANENT REPIARS TO THE DAY TANK FUEL OIL TRANSFER PUMP REMOTE SHUT OFF SWITCH AND TEST SATISFACTORILY.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROVIDE A GENERAL ALARM FLASHING LIGHT IN THE ENGINE ROOM WITH SUFFICIENT INTENSITY THAT WILL ALERT ALL PERSONNEL THROUGH OUT THE ENGINE ROOM.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PROPERLY SECURE ALL LOOSE WIRING IN THE WHEEL HOUSE.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
PERMANENTLY WIRE THE ANCHOR LIGHT ON THE FORWARD MAST.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Unknown
Issued 11 June 1990 Resolved
REPLACE ALL MISSING LIGHT COVERS THROUGH OUT THE VESSEL.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990

Casualty record · 2

20 May 2008Routine · role: Involved in a Marine Casualty · activity 3212651
11 November 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3510931
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.