Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named BAY MONARCH
BAY MONARCH is a 1976 passenger vessel (inspected). The Coast Guard has recorded 116 inspections since 1985, most recently in April 2025, along with 171 deficiencies — 2 with no resolution recorded —, 2 operational controls and 6 casualty investigations between 2005 and 2016.
Records from 1985 to 2025. Most recent: inspection, 17 April 2025.
- Built
- 1976
- Last inspected
- 17 April 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 116
- Deficiencies
- 171 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 6 investigations · 2005–2016
Identity
572538
WCZ9381
48697
Flag
UNITED STATES
368190860
Maury page id
psix-48697
Inspections, by type
…with no type recorded26
Years with a record
37 calendar years (1985–2025)
The 116 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)127.4 ft × 34.6 ft × 10.8 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOLBERG INC · STOCKTON CA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM2725MMSI 368190860 · active · compulsorily equipped · granted 3 April 2021, expires 3 April 2031
WCZ9381MMSI 366985310 · expired · compulsorily equipped · granted 5 June 2010, cancelled 19 September 2020
WCX6680MMSI not assigned · expired · compulsorily equipped · granted 11 August 1997, cancelled 13 October 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 116
17 April 2025
Examination of Repairs · Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8113647
19 February 2025
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8082537
13 March 2024
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7878012
28 November 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7831483
3 April 2023
Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7661657
15 February 2023
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7633275
17 November 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7595756
1 October 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7569816
14 April 2022
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7430912
8 February 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7393041
16 December 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7369433
6 August 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7279149
14 April 2021
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7174482
10 March 2021
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7157451
23 July 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7033245
28 January 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6895588
15 April 2019
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6663120
10 January 2019
Internal Structural Exam · In-Service Inspection · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6607718
10 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6558344
21 February 2018
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6356527
24 March 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6119321
15 March 2017
Annual Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6123904
27 December 2016
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6063996
16 December 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6060177
16 December 2016
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6061980
30 July 2016
Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5962766
18 February 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5817432
23 July 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4093900
27 January 2011
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3934630
28 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3880412
21 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3874980
19 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3873340
13 October 2010
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3879382
8 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3866439
7 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3865786
11 March 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3426828
10 December 2008
Drydock Exam · Examination of Repairs · Plan Review (Other than "T")
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3377459
17 October 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3377191
15 October 2008
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3345588
9 August 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3293597
11 May 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3203806
15 April 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3184919
29 March 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3173606
15 March 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3165205
20 February 2008
MTSA Verification · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3147188
2 February 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3140769
19 January 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3133230
21 February 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2872712
24 January 2007
Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2861041
15 July 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2837229
9 June 2006
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2675212
22 February 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2586534
1 December 2005
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2544671
20 May 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2363465
30 April 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2348447
16 March 2005
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2302125
10 March 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2269433
28 December 2004
In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2265530
9 July 2004
MTSA Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2127506
12 May 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2065933
20 April 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1996873
15 August 2003
In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1840197
16 April 2003
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1775005
17 March 2003
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1758334
25 February 2003
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1718595
19 December 2002
Construction Oversight
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1693430
9 December 2002
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1716433
15 November 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1706167
14 March 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1494427
6 February 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1480361
16 November 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384912
27 August 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1071217
14 August 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1069454
26 April 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1066546
20 April 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1063021
20 April 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1063022
6 March 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1454902
7 February 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1462185
8 February 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391218
5 April 1999
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 786521
8 March 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440098
5 February 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1458597
3 December 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 805480
9 February 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383770
9 July 1997
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1114397
26 June 1997
Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396751
21 June 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 134060
10 February 1997
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1439814
5 June 1996
Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380519
17 May 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 118527
8 February 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1455328
17 February 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 846214
18 January 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 866339
18 February 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 853690
8 February 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 852900
19 October 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149256
12 February 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1140939
3 February 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1133625
4 February 1992
COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 961185
9 March 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241850
11 February 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1221076
1 November 1990
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1215596
29 May 1990
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 916600
22 February 1990
COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 906363
20 October 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1212765
18 October 1989
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1042882
17 May 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1195856
8 March 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1204737
22 February 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1041081
24 February 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1331865
20 October 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1016415
26 February 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1006603
24 February 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1323172
3 April 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985103
11 March 1986
Credit Drydock · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1304316
11 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1286622
Deficiency record · 171
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2025
No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull... Hull wastage was found during drydock in the sewage void IVO stbd main longitudinal, 2nd transverse frame. Worst wastage was 40% in single pit. Vessel was unable to complete repair at drydock. Temporary belzona coating authorized, affected area to be cropped and renewed at next haul out. Vessel crew shall monitor the affected area weekly and maintain a log to ensure condition does not worsen. 46 CFR 116.100(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2025
No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull... Deck wastage was discovered in port fan space on 2nd deck. Temporary repair authorized to maintain watertight integrity. Crop and renew at next haul out. 46 CFR 116.100(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 March 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The vessel’s shaft seals were leaking beyond limitations. Vessel to repair shaft seals to proper limitations to the satisfaction of the marine inspector.
46 CFR 182.05-1
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 March 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessels Port/Starboard rudder posts packing glads leaking. Vessel to repair rudder posts packing glands to the satisfaction of the marine inspector.
46 CFR 182.05-1
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 March 2024
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel had an expired registration sticker. Vessel route restricted to 3 NM from the coastline.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 March 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine and test by operation all watertight closures in the hull, deck, and bulkheads. Vessels forward watertight door's bottom knife edge has wastage beyond limitations and has two inop dogs. Vessel to submit repair plan for knife edge wastage and replace dogs to the satisfaction of the marine inspector.
46 CFR 176.25-5(a)(2)
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 13 March 2024
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Vessels VHF-DSC does not have an MMSI number programed and does not have the ability to transmit latitude and longitude. Vessel to repair radio to the satisfaction of the marine inspector.
47 CFR 80.805
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 March 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine and test by operation all watertight closures in the hull, decks, and bulkheads. The vessel’s port hole in starboard engine room entryway is cracked. Vessel to replace port hull to the satisfaction of the marine inspector.
46 CFR 176.25-5(a)(2)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 March 2024
Resolved
An internal structural examination conducted in compliance with § 115.600 of this part may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating, voids, and ballast, cargo, and fuel oil tanks. Vessel has sharp insets on the port side of the sewage hold resulting in cracked welds between the 2nd, 3rd, and 5th frames. Vessel to submit repair plan to the satisfaction of the marine inspector prior to next credit dry dock.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 February 2023
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. Pressure gauge on fire pump was inadequate and did not read more than 30 psi.
46 CFR 181.10 (c) “OLD T”
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported a mechanical failure of three muff coupling bolts on the STBD shaft. Make repairs to satisfaction of attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of a vessel in accordance with the terms of its COI giving consideration for provisions for a seaworthy hull. Vessel struck piling and damaged rub rail on starboard quarter. Vessel is authorized a temporary welded repair utilizing a doubler.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of a vessel in accordance with the terms of its COI giving consideration for provisions for a seaworthy hull. Vessel to make permanent repairs for deficiency 01 prior to credit drydock. Plans shall be submitted as per 46 CFR 115.700(a) prior to starting work.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 February 2022
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine all accessible parts of the interior of the hull, and watertight bulkheads. Vessel has cable runs through bulkhead in between sewage void and engine room that are not secured with an approved sealant in addition to too many cables running through the bulkhead penetration.
46 CFR 176.25-5(a)(1) Old T(L)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 April 2021
Resolved
Adequate means of ground detection shall be provided on
ships service generator and distribution switchboard.
The bulb on panel for number two generator was inoperable.
46 CFR 111.30-15(b)(7)
(old J)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 April 2021
Resolved
Vessel operating in cold water that maintains radio communications every 15 minutes may provide life floats that will accommodate at least 100 % of total number of persons on board that is operating on limited coastwise route. Vessel has 12 life floats on board not concurrent with COI, passenger count restricted for limited coastwise to total persons on board 240.
46 CFR 117.205(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2021
Resolved
Distribution panels of switchboard type shall be completely enclosed or otherwise protected against accidental contact and unauthorized operation. MI observed no enclosure on general switchboard for starboard generator, leaving exposed wires.
46 CFR 111.40-1(b)(1)
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 April 2021
Resolved
Lighting fixtures in locations exposed to the weather or any other locations exposed to splashing water shall be made of watertight construction. The main deck overhead light was missing cover and bulb was inoperable.
46 CFR 111.75-20(b)
(old J)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2020
Resolved
The VSO must ensure that at least one security drill is conducted at least every three months. Security drill records not present.
33 CFR 104.230(b)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2020
Resolved
The vessel owner or operator must ensure that a written VSA report is prepared and included as part of the VSP. Vessel security assessment was not present.
33 CFR 104.305(d)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2020
Resolved
The CSO or VSO must ensure a audit of the VSP is performed annually. Security audit not present.
33 CFR 104.415(b)(1)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 January 2020
Resolved
The required monthly EPIRB test shall be logged or otherwise documented. No EPIRB logs found.
46 CFR 185.728(c)
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 28 January 2020
Resolved
Every vessel must have a detailed inspection of the radio installation by an FCC-licensed technician every five years. FCC-licensed technician did not verify inspection of EPIRB installation on Communications Act Safety Radiotelephony Certificate.
46 CFR 184.502 [Parent cite] & 47 CFR 80.903
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 January 2020
Resolved
When buoyant apparatuses are stowed in tiers, the separate units must be kept apart by spaces. Wooden spaces not evident in BA tiers.
46 CFR 180.137(f)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2020
Resolved
Electrical installations and equipment shall not cause fire and reasonably safe from electrical shock of personnel. Dead end wires in lazarette space found hanging in bilge and not capped.
46 CFR 183.01-5 [Old T]
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 October 2018
Resolved
ZERO DRAFT: no static draft information
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 March 2017
Resolved
Fixed CO2 systems on inspected vessels need to be type approved and installed in accordance with applicable regulations. Relocate the CO2 pressure switch outside of the protected space. Cite: 46CFR118.410(b)(1)(i), See MSIB 1512 for reference.
Construction/Loadline › Structures › Door
Issued 16 December 2016
Resolved
Repair damage to stern port side tonnage door to original condition to the satisfaction of the attending marine inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 16 December 2016
Resolved
Repair or replace remote pull cable for CO2 system and have the system retested to the satisfaction of attending marine inspector.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 18 February 2016
Resolved
The bouyant apparatus float free link must be the proper size for the bouyant apparatus. The current link is too large; change link size or re-arrange BAs on the STBD bridge wing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 18 February 2016
Resolved
Provide complete, accurate, and simple CO2 system instructions locally and at the remote pull station.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 March 2009
Resolved
Service 30-person IBA.
Stability › Intact Stability (when using lifting gear) › General
Issued 10 December 2008
Resolved
Prior to resuming normal operations the vessel is restricted to 587 passengers and 13 crew for a total of 600 persons onboard, with the maximum of 200 passengers on the upper deck. This requirement is to be posted for the Masters and crew to see at all times.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 October 2008
Resolved
Prove proper operation of starboard propulsion engine and shaft brake.
Communications › Radio Communications › EPIRB
Issued 20 February 2008
Resolved
Provide current hydrostatic release for EPIRB. Vessel is restricted to not more than 3 miles from shore.
Engineering › Bilge Water Management System › Strainer
Issued 20 February 2008
Resolved
Permanently affix lazarette bilge suction strainer.
Construction/Loadline › Hull › Side Shell
Issued 20 February 2008
Resolved
Submit repair proposal for 6-8" split, port side void #3 under stairs, and provide UT shots of plate side shell.
Construction/Loadline › Hull › Side Shell
Issued 20 February 2008
Resolved
Make repairs in accordance with approved plans.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 20 February 2008
Resolved
Properly label 35 child lifejackets. Replace retro reflective tape on 11 identified jackets, and remove 1 condemned jacket from forward storage locker on the port bow prior to carrying lifejackets on board.
Lifesaving › Hand Flares › Quantity
Issued 21 February 2007
Resolved
Replace required number of distress signals for vessel's Limited Coastwise route. Vessel is restricted to a Lakes, Bays, and Sounds route until this requirement is satisfied.
Communications › Radio Communications › EPIRB
Issued 21 February 2007
Resolved
Replace antenna on vessel's EPIRB. Vessel is restricted to voyages within the boundary line.
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 21 February 2007
Resolved
Replace hydrostatic release on the IBA. The IBA is a required equipment as per the SF-VMAP. The passenger count is reduced to 400 until this requirement is satisfied.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2007
Resolved
Submit repair proposal for the split in the side shell, port side in the CHT void, aft at the deck level approx 12" - 18" fwd of the bulkhead.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2007
Resolved
Make repairs IAW submitted and approved proposal plans.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 22 February 2006
Resolved
Replace chaffed port shaft air break hose.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 February 2006
Resolved
End cap E/R electrical outlet.
Lifesaving › Buoyant Apparatus › Float Free
Issued 22 February 2006
Resolved
Make starboard BA arrangement float free in way of retaining line tangled on stanchion.
Lifesaving › Buoyant Apparatus › Float Free
Issued 22 February 2006
Resolved
Provide spacer between stacked port BA's.
Electrical › Lighting (service) › Lighting Feeder
Issued 22 February 2006
Resolved
Renew main deck cracked light globe.
Stability › Weathertight Integrity › General
Issued 16 March 2005
Resolved
Provide specifications for new windows on main deck.
Construction/Loadline › Structures › Door
Issued 16 March 2005
Resolved
Crop and renew wasted overhead frames outside port and starboard embarkation doors.
Construction/Loadline › Structures › Door
Issued 16 March 2005
Resolved
Replace aluminum flange at base of frame on starboard embarkation door.
Construction/Loadline › Structures › Deck Plating
Issued 16 March 2005
Resolved
Provide gauging forward of both embarkation doors in way of bulkhead and deck under passenger bench.
Construction/Loadline › Hull › Stiffener
Issued 16 March 2005
Resolved
Crop and renew wasted bench (PFD storage) framing and supports on main deck.
Construction/Loadline › Structures › Scupper
Issued 16 March 2005
Resolved
Crop and renew deck drain at frame 20, starboard side, on main deck
Electrical › Electric Supply System (service) › Cable
Issued 16 March 2005
Resolved
Remove dead end wires on aft bulkhead on womens head.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 March 2005
Resolved
Repair junction box below loud hailer on aft section of 01 deck.
Accommodation/Occupational Safety › Ventilation › General
Issued 16 March 2005
Resolved
Provide screens for gooseneck vents under benches on forward part of 01 deck.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 March 2005
Resolved
Repair wastage on portside 01 deck bulkhead aft of last window.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 March 2005
Resolved
Repair holes in bulkhead below portside 01 deck fan room door.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 16 March 2005
Resolved
Provide plans and material list for generator keel cooler installation.
Construction/Loadline › Structures › Scuttle
Issued 16 March 2005
Resolved
Prove watertightness of all main deck watertight scuttles.
Construction/Loadline › Hull › Stiffener
Issued 16 March 2005
Resolved
Crop and renew wasted vertical stiffeners on forward side of collision bulkhead.
Construction/Loadline › Structures › Superstructure
Issued 16 March 2005
Resolved
Clean knife edges and prove both fore and aft watertight doors on main deck are watertight.
Construction/Loadline › Hull › Hull Plating
Issued 16 March 2005
Resolved
Provide gauging in fore peak in way of collision bulkhead and both sides of keel out to five feet in all directions.
Construction/Loadline › Hull › Hull Plating
Issued 16 March 2005
Resolved
Remove scale and standing water in fore peak to make space available for inspection
Construction/Loadline › Hull › Hull Plating
Issued 16 March 2005
Resolved
Provide gauging in #2 hold in way of the aft 4 frame bays alongside the keel out to the first longitudinal plate weld.
Engineering › Lubricating Oil Service System › Pump
Issued 16 March 2005
Resolved
Remove or plug abandoned oil piping in #2 hold.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 16 March 2005
Resolved
Repair leaks to sewage and sink drain piping in sewage void.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 16 March 2005
Resolved
Replace broken hose clamps on sewage system piping in sewage void.
Construction/Loadline › Hull › Hull Plating
Issued 16 March 2005
Resolved
Provide gauging in engine room, on starboard side hull plating in way of bilge manifold, bilge pump and raw water suction out to six feet.
Construction/Loadline › Hull › Hull Plating
Issued 16 March 2005
Resolved
Provide gauging in the engine room, starboard side in two frame bays from the fire pump to the MDE bed.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 16 March 2005
Resolved
Clean oil and garbage from bilge in engine room.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 16 March 2005
Resolved
Provide drawings for renewal of sea water intake valve and hull insert on starboard side engine room.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 16 March 2005
Resolved
Provide shaft and bearing reading report.
Personnel › Training › First Aid/CPR
Issued 10 March 2005
Resolved
Provide proof, that at a minimum, 50% of required deckhands are certified in having current CPR & First Aid training in accordance with NVIC 1-91.
Construction/Loadline › Structures › Air Pipe
Issued 10 March 2005
Resolved
Repair 8 goosenecks on 01 deck prior to the end of next drydock that is scheduled for 03/23/2005.
Engineering › Sea-water System (primary cooling) › Valve
Issued 10 March 2005
Resolved
Repair raw water leak on port main diesel engine's keel cooler isolation joint prior to the end of next drydock scheduled for 03/23/2005.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 March 2005
Resolved
Make repairs to 2 limber holes on starboard side in #4 void space adjoining to the Sewage Compartment prior to the end of next drydock scheduled for 03/23/2005.
Construction/Loadline › Structures › Deck Plating
Issued 10 March 2005
Resolved
Repair port and starboard brow embarkation holding points on main deck prior to the end of next drydock scheduled on 03/23/2005.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 10 March 2005
Resolved
Repair seized lid in way of 02 deck's forward most PFD storage locker.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 10 March 2005
Resolved
Clean & remove standing water in the port side, upper deck PFD locker.
Construction/Loadline › Structures › Superstructure
Issued 10 March 2005
Resolved
Crop & renew holes on the port side overhang forward of the pilot house as seen from the main deck prior to the end of next drydock scheduled on 03/23/2005.
Construction/Loadline › Structures › Door
Issued 10 March 2005
Resolved
Repair watertight door and missing/broken dogs prior to the end of next drydock scheduled on 03/23/2005.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 10 March 2005
Resolved
Renew 2 grates on the main deck passenger area electric heaters.
Lifesaving › Embarkation Appliances/Stations › Handholds
Issued 10 March 2005
Resolved
Repair 2 damaged stanchion pipes on aft deck prior to the end of next drydock scheduled on 03/23/2005.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 10 March 2005
Resolved
Repair mounting brackets on aft deck for IBA prior to the end of next drydock scheduled on 03/23/2005.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 10 March 2005
Resolved
Provide temporary IBA installation until mounting brackets from item #12 are repaired prior to the end of next drydock scheduled on 03/23/2005.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 March 2005
Resolved
[name withheld] with vessel's name.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 March 2005
Resolved
Provide log of EPIRB's NOAA registration, monthly testing & maintenance records
Personnel › Certificates/Documents/Licenses › PIC
Issued 10 March 2005
Resolved
Vessel's master sign Senior Deckhand letter.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 10 March 2005
Resolved
Provide current IBA servicing documentation.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 March 2005
Resolved
Remove old, expired COD that is posted in pilot house.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 March 2005
Resolved
Install 1/2" knock out plug in overhead 4-gang duplex outlet box in passenger area on main deck, starboard side.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 10 March 2005
Resolved
Install 1/2" knock out plug in engine room battery charger on right side of enclosure.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2005
Resolved
Replace spent (burnt) light bulbs in engine room.
Communications › Radio Communications
Issued 20 April 2004
Resolved
Vessel is restricted to no more than 3-NM off coast until EPIRB is repaired and properly installed back on vessel. LEGACY COMPONENT DESC: EPIRB
Lifesaving › Buoyant Apparatus
Issued 20 April 2004
Resolved
Remove covers from buoyant apparatus group so that they are free floating. LEGACY COMPONENT DESC: Covers
Fire Fighting › Combustible Materials
Issued 20 April 2004
Resolved
Remove fuel oil soaked absorbent pads from drip tray from fuel oil discharge pipe in engine space. LEGACY COMPONENT DESC: Fuel oil
Construction/Loadline › Penetrations
Issued 25 February 2003
Resolved
Repair sewage pump 3 inch discharge pipe to 4 bolt flange joint, in way of sewage void stbd side overhead. LEGACY COMPONENT DESC: Pipe Flange
Electrical › Electrical Distribution System (service)
Issued 25 February 2003
Resolved
Renew reset switch on sewage ejector pump controller in way of sewage void. LEGACY COMPONENT DESC: Switch
Engineering › Compressed Air System (start air)
Issued 25 February 2003
Resolved
Hydro test portside air receiver IAW 61.10-5 (3). LEGACY COMPONENT DESC: Receiver/Bottle
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 February 2003
Resolved
CONDEMNED 3 LIFE JACKETS
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 25 February 2003
Resolved
Anchor Windlass riding paw was frozen.
Stability › Watertight Integrity
Issued 25 February 2003
Resolved
Existing day light through cable stuffing tubes blk hd seperating voids three and four.
Engineering › Steering Gear System › Rudder Stock
Issued 25 February 2003
Resolved
excessive water leakage through rudder post packing.
Electrical › Electric Generation Source (service)
Issued 19 December 2002
Resolved
Demonstrate operation of low lubricating oil and high jacket water temperature shutdowns prior to operation with passengers. LEGACY COMPONENT DESC: Prime mover
Electrical › Lighting (emergency)
Issued 14 February 2002
Resolved
Ensure that there is portable lighting located at the accesses to the engineroom IAW 46 CFR 120.430.
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 February 2002
Resolved
Ensure that vessel name is marked on all lifejackets IAW 46 CFR 122.604. LEGACY COMPONENT DESC: Marking
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 February 2002
Resolved
Mark the locations of child and adult lifejackets located on the port and stbd side of ladder on main deck and on second deck port side. LEGACY COMPONENT DESC: Storage
Stability › Watertight Integrity
Issued 14 February 2002
Resolved
Ensure that hatch leading into the collision bulkhead is watertight.
Communications › Radio Communications
Issued 14 February 2002
Resolved
Ensure that EPIRB is registered with NOAA. LEGACY COMPONENT DESC: EPIRB
Engineering › Fuel Oil Service System
Issued 14 February 2002
Resolved
Replace damaged fuel tank vents IAW 46 CFR 119.450 LEGACY COMPONENT DESC: Vent Pipe
Navigation › Piloting/Steering
Issued 14 February 2002
Resolved
Ensure magnetic compass has a current deviation table. LEGACY COMPONENT DESC: Deviation Table/Graph
Construction/Loadline › Structures
Issued 14 February 2002
Resolved
Fix hole in superstructure below hatch leading into fan room on stbd side of 2nd deck. LEGACY COMPONENT DESC: Superstructure
Construction/Loadline
Issued 7 February 2001
Resolved
FILLET WELD OR CROP AND RENEW PORT SIDESHELL AND DECKPLATE IN WAY OF GANGWAY SOCKETS. ENSURE WATERTIGHT INTEGRITY.
Engineering
Issued 7 February 2001
Resolved
REPLACE PORT AND STARBOARD SHAFT PACKING.
Lifesaving
Issued 8 February 2000
Resolved
LIFE LIFE ATTACHMENT RING SEPERATED FROM BUOYANT APPARATUS WITH SER NO. 404
Lifesaving
Issued 8 February 2000
Resolved
LIFE LINE ATTACHMENT RING SEPERATED FROM BOUYANT APP WITH SER NO. 405.
Lifesaving
Issued 8 February 2000
Resolved
LIFE LINE ATTACHMENT RING SEPERATED FROM BUOYANT APP WITH SER NO. 411.
Engineering
Issued 8 February 1996
Resolved
Repair or replace relief valve on port side air receiver in engine room.
Construction/Loadline
Issued 18 January 1995
Resolved
REPAIR SUPPORTS FOR REACH ROD CONNECTED TO BILGE SUCTION VALVE IN CHAIN LOCKER.
Lifesaving
Issued 8 February 1994
Resolved
REPAIR CUTS AND PUT A SEAL COATING ON BUOYANT APPARATUS.
Lifesaving
Issued 8 February 1994
Resolved
LABEL THE LIFE JACKET STORAGE AREAS.
Electrical
Issued 8 February 1994
Resolved
IN #5 HOLD REPACK STUFFING TUBES FOR WIRE RUN ON THE FWD BULKHEAD.
Fire Fighting
Issued 8 February 1994
Resolved
SERVICE THE FIXED CO2 SYSTEM.
Lifesaving
Issued 8 February 1994
Resolved
REPLACE LINES FOR PAINTERS ON BUOYANT APPARATUS.
Construction/Loadline
Issued 3 February 1993
Resolved
CROP AND RENEW WASTED FOREPEAK HATCH.
Construction/Loadline
Issued 3 February 1993
Resolved
CROP AND RENEW BOTTOM COAMING ON BOTH PORT AND STARBOARD WEATHERTIGHT DOORS.
Electrical
Issued 4 February 1992
Resolved
PROVIDE AND INSTALL PROPER ELECTRICAL CONNECTORS IN THE FOLLOWING AREAS: PILOT HOUSE (FWD & AFT CABINETS), ENG ROOM (STBD MAIN DIESEL ENG TACH GEN CONNECTIONS.)
Accommodation/Occupational Safety
Issued 4 February 1992
Resolved
PROVIDE & INSTALL PERMANENT BRACKET FOR PRESSURIZED BOTTLES IN THE SNACK BAR AREA.
Electrical
Issued 4 February 1992
Resolved
PROVIDE & INSTALL RUBBER GASKET FOR 120 VAC OUTLET ON TRANSOM.
Electrical
Issued 4 February 1992
Resolved
PROVIDE & INSTALL COVER FOR J-BOX ON SEWAGE RAW WATER SUPPLY PUMP.
Deck/Cargo
Issued 11 February 1991
Resolved
PROVIDE ONE ADDITIONAL ANCHOR AND CHAIN.
Fire Fighting
Issued 22 February 1990
Resolved
REPLACE THE B-I PORTABLE EXTINGUISHER IN THE GALLEY WITH A B-II, AND PROVIDE AN ADDITIONAL B-II FOR THE SECOND PASSENGER DECK.
Navigation
Issued 22 February 1990
Resolved
REPAIR HYDRAULIC LEAKS AND REMOVE HYDRAULIC FLUID FROM THE BILGE IN COMPARTMENTS #3 & #4.
Engineering
Issued 22 February 1990
Resolved
REPAIR GEAR OIL LEAK IN THE #1 MAIN DIESEL ENGINE.
Electrical
Issued 22 February 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF LOW LUBE OIL AND HIGH TEMP SHUTDOWN ON #2 GENERATOR.
Construction/Loadline
Issued 22 February 1990
Resolved
REPLACE MISSING DECK DRAIN GRATES ON ALL WX DECKS.
Construction/Loadline
Issued 20 October 1989
Resolved
REMOVE HYDRALIC FLUID FROM ALL VOID COMPARTMENTS.
Construction/Loadline
Issued 20 October 1989
Resolved
AT NEXT DRYDOCK, INSTALL VALVES IN KEEL COOLER LINES AT VESSEL'S BOTTOM SHELL PLATE.
Construction/Loadline
Issued 17 May 1989
Resolved
REPAIR AND HOSE TEST FOREPEAK FLUSH DECK HATCH COVER AND REATTACH CAPTURE CHAIN.
Navigation
Issued 17 May 1989
Resolved
REPAIR AS MARKED, FRACTURES IN WAY OF PORT RUDDER LOG STIFFENERS.
Navigation
Issued 17 May 1989
Resolved
REPAIR STEERING GEAR HYDROLIC LEAKES BETWEEN MSD ROOM AND PILOT HOUSE.
Fire Fighting
Issued 8 March 1989
Resolved
INSTALL & DEMONSTRATE PROPER OPERATION OF OPENING CLOSURES FOR MACHINERY SPACE PROTECTED BY FIXED CO2 SYSTEM IAW 46 CFR 76.15-35(C) AND NVIC 11-83.
Lifesaving
Issued 22 February 1989
Resolved
PROVIDE 80 ADULT PFD'S; OPS LIMITED TO 720 ADULT PASSENGERS UNTIL PROVIDED.
Construction/Loadline
Issued 22 February 1989
Resolved
REPAIR ACCESS SIDE PORT, STARBOARD SIDE IN WAY OF LADDER TO ENGINE COMPARTMENT, SO THAT IT IS WATERTIGHT.
Engineering
Issued 24 February 1988
Resolved
REPAIR STBD ENGINE PRIOR TO OPERATION.
Deck/Cargo
Issued 24 February 1988
Resolved
PROVIDE ONE ADDITIONAL ANCHOR.
Construction/Loadline
Issued 24 February 1988
Resolved
REPAIR PORT AND STBD SIDE PORTS LOCATED IN ENINGEROOM ACCESSES SO THAT THEYARE WATERTIGHT.
Lifesaving
Issued 24 February 1987
Resolved
PROVIDE ONE ADDITIONAL RING LIFE BUOY WITH A WATER LIGHT AND 60 FEET OF LINE.
Lifesaving
Issued 24 February 1987
Resolved
REPLACE THE GRAB LINES ON ALL BUOYANT APPARATUS.
Lifesaving
Issued 24 February 1987
Resolved
PROVIDE TWO 20-MAN BUOYANT APPARATUS TO BRING THE TOTAL ON BOARD TO 20 (20-MAN) BUOYANT APPARATUS.
Navigation
Issued 24 February 1987
Resolved
REPOSITION THE VESSEL'S NAVIGATION LIGHTS TO COMPLY WITH 72 COLREGS.
Construction/Loadline
Issued 24 February 1987
Resolved
REMOVE BILGE WATER AND OIL FROM THE FOLLOWING SPACES: ENGINEROOM, #2 VOID, MSD COMPARTMENT.
Accommodation/Occupational Safety
Issued 24 February 1987
Resolved
REPAIR THE BROKEN LADDER RUNG AT THE BASE OF THE STEERING GEAR COMPARTMENT.
Construction/Loadline
Issued 24 February 1987
Resolved
INSTALL A CAPTIVE CHAIN FOR THE FORE PEAK WATERTIGHT HATCH.
Engineering
Issued 11 March 1986
Resolved
RENEW BILGE LINE IN FOREPEAK.
Construction/Loadline
Issued 11 March 1986
Resolved
RENEW APPROXIMATELY 3 FEET OF VENT LINE IN FOREPEAK.
Construction/Loadline
Issued 11 March 1986
Resolved
CLEAN BOTH BILGE STRAINERS IN ENGINE ROOM.
Lifesaving
Issued 11 March 1986
Resolved
REPAIR LEAKING PACKING / SEAL IN AFTER BILGE PUMP.
Construction/Loadline
Issued 11 March 1986
Resolved
REPAIR LEAK WHERE PORT FUEL OIL SUPPLY PIPING ENTERS ENGINEROOM AND TANK SPACE BULKHEAD.
Fire Fighting
Issued 11 March 1985
Resolved
REPLACE FIRE HOSE ON 02 DECK PRIOR TO OPERATIONS BUT IN NO CASE LATER THAN COMPLIANCE DATE.
Navigation
Issued 11 March 1985
Resolved
OBTAIN ANCHOR LIGHT PRIOR TO OPERATIONS BUT IN NO CASE LATER THAN COMPLIANCE DATE.
Documentation
Issued 11 March 1985
Resolved
RENEW VESSEL'S DOCUMENT.
Engineering
Issued 11 March 1985
Resolved
TIGHTEN LOOSE JCT BOXES ON STBD MAIN ENGINE.
Accommodation/Occupational Safety
Issued 11 March 1985
Resolved
CLEAN UP HYDRAULIC OIL IN BILGES OF SEWAGE TANK COMPARTMENT AND WATCH FOR FURTHER LEAKAGE.
Fire Fighting
Issued 11 March 1985
Resolved
INSTALL DISCHARGE AND SUCTION HOSES ON HAND PUMP AND PROVE 5 GPM OUTPUT WITH THEM.
Accommodation/Occupational Safety
Issued 11 March 1985
Resolved
REWELD LADDER RUNG IN STEERING COMPT.
Electrical
Issued 11 March 1985
Resolved
INSTALL THREE-PRONG PLUG TO GROUND THE BEVERAGE DISPENSER.
Engineering
Issued 11 March 1985
Resolved
TIGHTEN FO SHUTOFF VALVES P/S, TEST REMOTE OPERATION AND CLEAN UP FO IN BILGES OF FUEL TANK COMPARTMENT, PRIOR TO OPERATIONS BUT IN NO CASE LATER THAN COMPLIANCE DATE.
Casualty record · 6
30 April 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2348447
17 October 2008Routine · role: Involved in a Marine Casualty · activity 3377191
22 May 2011Routine · role: Involved in a Marine Casualty · activity 4019950
29 October 2011Routine · role: Involved in a Marine Casualty · activity 4179619
27 April 2012Routine · role: Involved in a Marine Casualty · activity 4329253
16 December 2016Routine · role: Involved in a Marine Casualty · activity 6060177
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.