Inspection history · 66
28 July 2025
COC-CVE Annual
Administrative · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8197954
13 July 2025
PSC B
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 8184996
3 October 2024
COC-CVE Quarterly · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8013955
1 August 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7972518
22 July 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7964326
6 July 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7950299
21 June 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7939798
17 June 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7936896
20 April 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7917560
12 April 2024
PSC B · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7892164
8 February 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7877325
4 October 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7803081
6 July 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7808938
19 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7805658
13 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7785716
12 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7785717
2 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7757915
27 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7750359
27 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7750368
25 April 2023
PSC A · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7675021
4 January 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616421
30 November 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7602081
13 October 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7577040
24 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542740
9 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529390
29 July 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7519803
21 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7483457
21 June 2022
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7483505
21 June 2022
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7875303
14 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7477770
16 April 2022
PSC B · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7430558
7 January 2021
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7120900
14 October 2020
Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 7081577
8 October 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7074304
4 April 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6935637
1 November 2019
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6846741
28 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6825497
25 September 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6821072
30 August 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6799323
14 August 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6783248
30 April 2019
COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6673528
25 March 2019
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6649058
6 November 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6576000
22 October 2018
ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6565708
2 October 2018
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6554053
1 October 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6581757
22 May 2018
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6414534
3 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6404641
19 March 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6374835
8 November 2017
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6303519
8 November 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306296
17 October 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6287172
8 October 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6284130
15 September 2017
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6270555
22 August 2017
Special · MARPOL Annex IV Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6248818
15 August 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6244045
24 May 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6154805
24 April 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6129044
5 February 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6082491
3 February 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6082081
4 January 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065777
22 December 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6061422
6 November 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6036063
23 October 2016
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6027769
19 September 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6005089
24 April 2016
COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5861025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 October 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of more than 40 s and no less than 20 s. PSCO observed fire door 05.5.14 unable to fully close. 74SOLAS 97 II-2/30.4.1, 10c
Action required: 10 - Deficiency Rectified
Due 3 October 2024
Resolved 3 October 2024
Resolution: Vessel crew corrected self-closure.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 October 2023
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for the safety in an emergency, due regard being paid to such services as may have been operated simultaneously. The emergency source of electrical power shall be capable, having regard to starting currents and the transitory nature of certain loads, of supplying simultaneously at least the following services for the periods specified hereinafter (section 2.1-2.6), if they depend upon electrical source for their operation. PSCO observed independent fuel supply level at .2 meters below required level. Fuel supply level must be maintained at 1.2 meters to be able to supply emergency systems throughout required time period.
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: Engineering staff refilled independent fuel supply tank to required level.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 October 2023
Resolved
Doors and door frames in "B" class divisions ventilation openings may be permitted in the lower portion of such doors. Where such openings is in or under a door the total net area of any such opening or openings shall not exceed 0.05 m2. When such opening is cut in a door it shall be fitted with a grill made of non-combustible material. PSCO observed that method to secure the lower portion of the ventilation grill was found to be missing and rendering the closure inoperable.
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: Crew was able to close the ventilation opening and leave it in the closed position.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 October 2023
Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. PSCO observed multiple B15 doors that were not able to secure due to the latching issue, the following doors were noted (OFFICE 3E082, CREW MESS 3G094).
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: Crew repaired/adjusted doors so they latched properly.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 4 October 2023
Resolved
The company should establish procedures, plans and instructions, including checklist as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. PSCO observed checklist for fuel transfer operations was logged prematurely, checklist section for completion of transfer was logged completed while fuel was actively being transferred.
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: On the spot training completed by Chief Engineer to engineering staff.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 October 2023
Resolved
When the fire-extinguishing medium is stored outside a protected space, it shall be stored in a room which shall be situated in a safe and readily accessible position and shall be effectively ventilated to the satisfaction of the administration. PSCO noted damage to the blet on the belt driven ventilation fan in the CO2 space.
Action required: 10 - Deficiency Rectified
Resolved 4 October 2023
Resolution: belt was replaced and ventilation verified operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 November 2019
Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. In spa area, which was recently modified, corridors were furnished with non-fixed seating in way of reception desk.74SOLAS II-2/13.1.2
Action required: 10 - Deficiency Rectified
Resolved 1 November 2019
Resolution: Furnishing was readjusted in way to not obstruct escape route.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 November 2019
Resolved
At least two widely separated and ready means of escape shall be provided from all spaces. The secondary escape from the gym is not labeled and contains door with locking mechanism. 74SOLAS, II-2/13.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 October 2020
Resolution: Recieved class society report which properly docoumented the deficiency rectified.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 25 March 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.Ship reported loss of approximately 35 liters of stern tube oil for unknown reasons.
Action required: 705 - Other - as specified
Due 6 September 2019
Resolved 29 September 2019
Resolution: Satisfactory class report, see documents for additional information.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 26 October 2018
Resolved
To assist in casualty investigations ships shall be fitted with a voyage data recorder. The VDR on board had an issue with the hard drive and can't record data for two newly installed fire screen doors or water depth.
74 SOLAS (2014) V/20.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 October 2018
Resolved 6 November 2018
Resolution: VDR manufacturer technician attended and rectified deficiency.
Engineering › Generator (propulsion-electric) › Reverse Power Protection Relay Circuitry
Issued 8 November 2017
Resolved
1410-Propulsion Main Engine- The condition of the ship and its equipment shall be maintained to conform with the provisions of the regulating to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Vessel experienced a complete loss of ships power and propulsion. The ship was operating with three of four diesel generators online. All three generators tripped offline without advance warning- 74SOLAS(04) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2017
Resolution: Received class report confirming repairs and satisfactory testing was completed on SSDGs 1 thru 4, along with testing of the power management system and protection/reverse power relays.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 November 2017
Resolved
1430-Auxilliary Engines- The electrical power available shall be sufficient to supply all the services essentialfor safety in an emergency with due regard for services that must be operated simultaneously following the vessel's loss of ship service power and propulsion, the emergency generator successfully started but subsequently experienced a high temperature condtion that rendered the generator inoperable- 74SOLAS(04) II-1/42.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2017
Resolution: Received class report confirming repairs and satisfactory testing of the EDG.
Engineering › Fuel Oil Service System › Valve
Issued 17 October 2017
Resolved
74 SOLAS (2001 cons) Ch. II-2/15.2.5 - Every oil fuel pipe, which if damaged would allow oil to escape from a storage settling or daily service tank situated above the double bottom shall be fitted with a vavle capable of being closed from a safe position outside the space. Quick closing valve CTT2164 did not properly close.
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 17 October 2017
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 17 October 2017
Resolved
74 SOLAS (2001 cons) Ch. II-2/18.1.1 - Where "A" class divisions are penetrated for the passage of electrical cables, pipes, trunks, etc. shall be made to ensure that the fire resistance is not impaired. Copper gauge line running through the bulkhead at frame 116 from the laundry room to the chiller room on stbd side is not properly insulated.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 17 October 2017
Engineering › Thrusters › Seal
Issued 9 October 2017
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel personnel discovered an oil leak originating from the bow thruster during a load test. 74 SOLAS (14Cons)Chapter I, Reg 11(a)
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 24 October 2017
Resolution: Received Corrective Action Statement from [name withheld] stating the short term actions that have been implemented until a long term fix is identified. Condition of Class issued, due October 2018.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 14 February 2017
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations... The NRC has received three separate reports in four months related to hydraulic oil leaking from the starboard propeller shaft. Request a monitoring procedure approved by Class to assess the respective gravity tank until May 2017 dry-dock.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 24 May 2017
Resolution: Starboard stern tube shaft seal replaced during May 2017 dry dock.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 22 December 2016
Resolved
The machinery and fittings shall be of a design and construcion adequate for service for which the are intended. Stbd side shaft is leaking approximately 1.5 Liters/Day through external seal. 74 SOLAS (09) II-1 / 26.1
Action required: 15 - Rectify deficiencies by next port
Resolved 4 January 2017
Resolution: Recieved class report attesting to the repair of the vessel shaft seal.