MAURY USCG vessel records Sign in
← All vessels

TIKI

TIKI is a 1975 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1985, most recently in May 2026, along with 72 deficiencies, 3 operational controls and 2 casualty investigations between 2008 and 2019.

Records from 1985 to 2026. Most recent: inspection, 21 May 2026.

Built
1975
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7702
Flag
UNITED STATES
367396560
Maury page id
psix-48702

Inspections, by type

…with no type recorded5
Years with a record 38 calendar years (1985–2026)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.0 ft × 20.0 ft × 3.4 ft
Registered tonnagegross 24 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRYSTALINER CORPORATION · COSTA MESA, CA, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE7702MMSI 367396560 · active · compulsorily equipped · granted 21 February 2019, expires 24 February 2029
WBJ9516MMSI not assigned · expired · compulsorily equipped · granted 2 September 1997, cancelled 13 October 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 75

21 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8332589
25 February 2026 Administrative Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8282739
24 February 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8063053
29 May 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7909441
21 February 2024 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7845953
16 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675548
4 April 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7629993
31 May 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7422382
8 February 2022 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7311630
20 May 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7302049
3 March 2020 DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6914859
25 February 2020 Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6877388
11 April 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6630810
19 February 2019 Damage Survey · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6628484
18 February 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6630109
27 March 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6364147
6 March 2018 Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6367952
1 March 2018 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6364376
2 March 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6084298
9 March 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5811545
2 February 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5811538
30 May 2012 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4294354
21 February 2012 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4227969
23 February 2010 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3662681
12 January 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3662670
12 February 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3390403
26 April 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3194589
15 April 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3177789
30 January 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3122291
26 July 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3008340
26 April 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2916066
12 April 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2872890
8 March 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2598089
6 February 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2580024
29 March 2005 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2322547
28 February 2005 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2297971
13 April 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2042395
13 January 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1980509
22 October 2003 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1928063
10 April 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1770508
20 March 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1597230
6 November 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382429
10 May 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373467
22 March 2001 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1064566
2 March 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1433603
16 November 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451463
23 March 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445437
16 February 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1128736
24 March 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1402628
2 October 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406190
6 March 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1441180
7 March 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1422645
29 September 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390126
6 March 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1434225
9 March 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 857685
21 September 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1158168
25 March 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149198
19 March 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1318489
24 September 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1251023
13 March 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1231780
13 March 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1231957
28 March 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1225776
26 September 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210245
13 March 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 893468
13 June 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 890144
25 April 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1341490
24 March 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 990547
8 May 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335625
28 April 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1322978
23 April 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1322977
30 December 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1313721
29 April 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985047
27 March 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985046
28 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 983926
27 March 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288631

Deficiency record · 72

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable regs. Vessel bow & stern light are not properly working. Vessel restricted to day time operations only. 46CFR183.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2026
Resolved 21 May 2026
Resolution: Vessel renewed bulbs & socket for stern light.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 February 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Generator failed to shutdown when tested. Prove proper shutdown of generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 19 March 2025
Resolution: Generator wired into shut-down circuit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 February 2025 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Ring buoy waterlight had an unapproved spring terminal battery installed. Replace battery with approved battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 14 April 2025
Resolution: Proper battery installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2025 Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Provide required markings on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2025
Resolved 14 April 2025
Resolution: Name and hailing port on stern.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. While the vessel is certificated to carry 150 total persons, 142 adult life jackets were found on board. The maximum amount of persons allowed on board is 142 persons until the full complement of life jackets is made available on the vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 21 April 2023
Resolution: Photographs of additional eight life jackets marked with the vessel's name were provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 April 2023 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. The vessel's whistle was found to be inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 21 April 2023
Resolution: Owner provided a video proving operation of the ship's whistle.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 4 April 2023 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. The magnetic compass is not fitted with a light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 21 April 2023
Resolution: Photos of a newly-installed magnetic compass with light was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The vessel had placards identifying stowage for 124 life jackets while the vessel is certificated for 150 total persons.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 28 April 2023
Resolution: Received photos from owner that placards have been installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 March 2020 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel does not have vent closures for the engine room and it is protected by a fixed fire fighting system. Provide vent closures for the vents for the engine room. 46CFR182.470
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2020
Resolved 30 September 2020
Resolution: Vent closures were installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 March 2020 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by am FCC licensed technician in accordance with 47CFR80.59 once every 5 years. Vessel does not have a radiotelephony certificate. 47CFR80.903
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2020
Resolved 3 May 2020
Resolution: Vessel provided proof of valid Radiotelephony Certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 March 2020 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. There is no machinery guard on the exposed gears and bels on the generator. Install machinery guard. 46CFR177.35-15.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2020
Resolved 30 September 2020
Resolution: A machinery guard was installed on the generator.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 11 April 2019 Resolved
Vessel did not have a valid FCC Safety Certificate or valid Radio Station Authorization.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 11 May 2019
Resolution: Received confirmation from vessel operator that a valid FCC Safety Certificate was obtained.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2019 Resolved
Updated Navigational Charts were not onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 15 April 2019
Resolution: New charts purchased for the vessels operatings area (Newport Bay).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 February 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load without exceeding its designed limitations. Prove proper operation of the Port Main Engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2019
Resolution: The vessel operator replaced the fuel filter, fuel pump and had the transmission rebuilt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 February 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load without exceeding its designed limitations. Prove proper operation of the Starboard Main Engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2019
Resolution: The vessel operator replaced the fuel filter, fuel pump and had the transmission rebuilt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 February 2019 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubrication oil pressure must be provided for all propulsion engines installed in the vessel. RPM indictors for both engines (Port/Starboard) are inoperable. Also, Oil Pressure Gauges require verification of proper function (correct readings).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2019
Resolution: The RPM and oil gauges were repaired and verified to be working properly.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 27 March 2018 Resolved
Vessel required to provide at least two means of shutdown for port main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2018
Resolved 1 March 2019
Resolution: MI witnessed proper operation of of two means of shutdown for port main diesel engine.
Engineering › Bilge Water Management System › Valve
Issued 27 March 2018 Resolved
Provide stop and check valves or stop-check valve to bilge system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2018
Resolved 29 March 2018
Resolution: Inspected the bilge system manifold and it appears there are stop check valves in the engine room bilge manifold WOG 200 1.5 inch bronze.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 March 2018 Resolved
Complete satisfactory drydock inspection for credit.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 20 March 2018
Resolution: Completed Satisfactory Credit Drydock.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 March 2017 Resolved
Vessel did not have a valid FFC Safety Certificate
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 11 May 2019
Resolution: Received confirmation from vessel owner that a valid FCC License had been obtained.
Stability › Weathertight Integrity › General
Issued 2 February 2016 Resolved
Repair 2 broken windows for the house on 2nd deck.
Action required: 705 - Other - as specified
Due 2 October 2016
Resolved 5 February 2016
Construction/Loadline › Hull › Hull Plating
Issued 2 February 2016 Resolved
Repair, remove, clean and treat wood rot on stern hull as indicated by the Marine Inspector.
Due 2 March 2016
Resolved 5 February 2016
Engineering › Sea-water System (primary cooling) › Valve
Issued 2 February 2016 Resolved
Replace 4 seavalves as indicated by Marine Inspector.
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 5 February 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 May 2012 Resolved
A B-II fire extinguisher had an expired service tag. The extinguisher was missed when the service report was completed. Extinguisher was replaced with a valid extinguisher and the servicing company was contacted to schedule servicing of the missed extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2012
Resolved 30 May 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 January 2008 Resolved
Crop and renew wasted upper deck rails. Vessel may not carry passengers on outer deck area until competed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 15 April 2008
Resolution: Renewed upper deck rails.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 January 2008 Resolved
Install and hang wiring in engine room overhead with metal clips every 24 inches.
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 15 April 2008
Resolution: Metal clips installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 30 January 2008 Resolved
Make aft engine room bulkhead air & water tight.
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 15 April 2008
Resolution: Bulkhead sealed and made water and air tight.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 12 April 2007 Resolved
Provide proof of 1 hour supervisor training (EAP).
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 26 July 2007
Resolution: Received a fax from vessel rep showing that [name withheld] is the designated vessel representative that has watched the EAP training video and understands the concepts.
Engineering › Bilge Water Management System › Interface Detector
Issued 12 April 2007 Resolved
Ensure all visual alarms (bilge) are working for the correct compartments.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 24 April 2007
Resolution: Bilge alarms are working in correct compartments as identified on bridge console.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 April 2007 Resolved
Ensure/provide appropriate number of lifejackets are onboard. Total person count is reduced to 140.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 31 July 2007
Resolution: Vessel reps bought 9 additional life jackets, stenciled them with vessel name and added them to the vessel.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 February 2006 Resolved
Provide in line fuses for wires powering fuel pumps and bilge pump in engine room.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 8 March 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2006 Resolved
Replace speaker wire powering starboard fuel pump with approved wiring.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 8 March 2006
Construction/Loadline › Hull › Stringer
Issued 28 February 2005 Resolved
Scrape and treat rot on stringers on both port and starboard side where engines are mounted on outboard side.
Action required: 705 - Other - as specified
Due 28 March 2005
Resolved 29 March 2005
Resolution: Cleaned and treated rot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 February 2005 Resolved
Provide metal clamps every 24" IAW 46CFR183.340(b)(4) throughout vessel.
Action required: 705 - Other - as specified
Due 28 March 2005
Resolved 29 March 2005
Resolution: Provided clamps.
Engineering › Bilge Water Management System › Piping
Issued 28 February 2005 Resolved
Replace flexible hose in bilge system with metallic hose.
Action required: 705 - Other - as specified
Due 28 March 2005
Resolved 29 March 2005
Resolution: Replaced bilge piping with metalic piping.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 February 2005 Resolved
Provide 12 adult lifejackets, person on board limited to 138.
Action required: 705 - Other - as specified
Due 28 March 2005
Resolved 29 March 2005
Resolution: Provided 12 adult Type I lifejackets.
Engineering › Bilge Water Management System › Manifold
Issued 28 February 2005 Resolved
Provide labels on bilge manifold.
Action required: 705 - Other - as specified
Due 28 March 2005
Resolved 29 March 2005
Resolution: Labeled manifold.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 April 2004 Resolved
Failed one child's life jacket and five adult life jackets. Owner to provide replacement.
Action required: 705 - Other - as specified
Due 13 April 2004
Resolved 13 April 2004
Resolution: Owner provided correct number of life jackets for both adults and children.
Engineering › Bilge Water Management System
Issued 22 October 2003 Resolved
Bilge line in forward water tank space wasted/rusted. Renew repair bilge line and remove flexible hose IAW 46 CFR 182.510 LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 30 November 2003
Resolved 25 November 2003
Engineering › Bilge Water Management System
Issued 22 October 2003 Resolved
Bilge line in lazarette wasted/rusted. Renew repair bilge line and remove flexible hose IAW 46 CFR 182.510 LEGACY COMPONENT DESC: Piping
Due 30 November 2003
Resolved 25 November 2003
Engineering › Bilge Water Management System
Issued 22 October 2003 Resolved
Bilge line in engine room loose. Anchor bilge line and remove flexible hose IAW 46 CFR 182.510 LEGACY COMPONENT DESC: Piping
Due 30 November 2003
Resolved 25 November 2003
Engineering › Bilge Water Management System
Issued 10 April 2003 Resolved
Renew bilge piping. IAW 46 CFR 182. To be completed during next drydocking but in no case later than 30NOV03. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 22 October 2003
Resolution: Cancelled 835. Reissued on 22 Oct 03
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2002 Resolved
Remove loose wires on bridge under control console, insulate exposed wires in fuel tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2002
Resolved 20 March 2002
Resolution: Loose wires removed and insulated.
Engineering › Sea-water System (primary cooling)
Issued 20 March 2002 Resolved
Replace deteriorated generator S/W cooling suction hose.
Action required: 705 - Other - as specified
Due 20 March 2002
Resolved 20 March 2002
Resolution: Hose replaced.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 March 2002 Resolved
Re-Install 2nd hose clamp to diesel fuel tank fill flex hose section.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2002
Resolved 20 March 2002
Resolution: Hose clamp re-installed.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 20 March 2002 Resolved
Connect steering compartment's electrical bonding network to vessels's bonding system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2002
Resolved 20 March 2002
Resolution: Bonding system connected.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 20 March 2002 Resolved
Replace one child size life jacket due to wasted straps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2002
Resolved 20 March 2002
Resolution: Life jacket replaced.
Navigation
Issued 22 March 2001 Resolved
Demonstrate operation of new steering system. The new steering system mustmeet the requirements of 46 CFR 182.600. No passengers may be carried oncethe new steering system is installed until it is approved by an attending marine inspector.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Accommodation/Occupational Safety
Issued 16 November 1999 Resolved
Provide check valves for all through hull fittings below the waterline.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Documentation
Issued 23 March 1999 Resolved
Provide proof of current Certificate of Documentation renewal sticker.
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Engineering
Issued 24 March 1998 Resolved
Renew fuel supply hoses and fittings on all machinery with CG appoved type.
Condition: Unknown
Due 7 April 1998
Resolved 27 March 1998
Construction/Loadline
Issued 2 October 1997 Resolved
835 issued, TO perminately plug through-hull fittings located in FWD most void space, port side. Item to be completed prior to 8 OCT 97.
Condition: Unknown
Due 8 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 2 October 1997 Resolved
835 issued. Operator to submit repair proposal for work to be completed. Work must be completed prior to carrying passengers for hire.
Condition: Unknown
Due 8 October 1997
Resolved 20 October 1997
Construction/Loadline
Issued 9 March 1994 Resolved
PROVIDE DOUBLE CLAMPING ON ALL FLEXIBLE BILGE HOSE EXTENSIONS.
Condition: Unknown
Due 15 April 1994
Resolved 14 March 1994
Fire Fighting
Issued 9 March 1994 Resolved
PROVE PROPER SERVICING AND HYDROSTATIC TESTING OF ALL DRY CHEMICAL HAND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 15 April 1994
Resolved 14 March 1994
Fire Fighting
Issued 9 March 1994 Resolved
REPLACE ELBOW JOINTS IN THE FIXED CO2 PIPING WITH "T" JOINTS WITH 2" EXTENSIONS (CAPPED).
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Fire Fighting
Issued 9 March 1994 Resolved
POST, AT THE CO2 CONTROL STATION, INSTRUCTIONS FOR OPERATING THE FIXED CO2 SYSTEM.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Lifesaving
Issued 9 March 1994 Resolved
STENCIL UPPER DECK PFD STOWAGE AS APPROPRIATE.
Condition: Unknown
Due 15 April 1994
Resolved 14 March 1994
Fire Fighting
Issued 9 March 1994 Resolved
PROVIDE UPTAKE HOSE OF SUITABLE LENGTH ON PORTABLE HAND PUMP.
Condition: Unknown
Due 15 April 1994
Resolved 14 March 1994
Electrical
Issued 9 March 1994 Resolved
REPLACE WINGNUTS ON ALL BATTERY TERMINALS WITH REGULAR NUTS, AND WASHERS ASNEEDED, IN ACCORDANCE WITH GOOD MARINE PRACTICE.
Condition: Unknown
Due 15 April 1994
Resolved 14 March 1994
Lifesaving
Issued 9 March 1994 Resolved
VESSEL'S ROUTE IS RESTRICTED TO CARRYING 142 PERSONS ON BOARD UNTIL AN ADDITIONAL EIGHT ADULT PFDS ARE PROVIDED.
Condition: Unknown
Due 15 April 1994
Resolved 14 March 1994
Electrical
Issued 25 March 1993 Resolved
ENSURE THAT ALL LIGHT BULBS ON BOARD ARE COVERED WITH APPROPRIATE FIXTURES.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Fire Fighting
Issued 25 March 1993 Resolved
PROVIDE ADDITIONAL PORTABLE B-II FIRE EXTINGUISHER AND APPROVED BRACKET FORUPPER ACCOMMODATION SPACE, BRINGING TOTAL NUMBER OF PORTABLE FIRE EXTINGUISHERS REQUIRED ON BOARD TO THREE (1 B-II, UPPER ACCOMMODATION SPACE; 1 B-II, LOWER ACCOMMODATION SPACE; AND 1 B-I, WHEEL HOUSE).
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Lifesaving
Issued 19 March 1992 Resolved
REPLACE RING BUOY IN WHEELHOUSE WITH COAST GUARD APPROVED 24" DIAMETER RINGBUOY.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Electrical
Issued 19 March 1992 Resolved
INSTALL METALLIC WIRE SUPPORTS IN THE ENGINEROOM ON 24" CENTERS.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Engineering
Issued 26 September 1989 Resolved
RENEW SEA VALVE FOR GENERATOR SALT WATER INTAKE AND FREE UP SEA VALVE FOR STBD MAIN ENGINE SALT WATER INTAKE.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Documentation
Issued 24 March 1988 Resolved
RENEW EXPIRED DOCUMENT.
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Fire Fighting
Issued 23 April 1987 Resolved
REPAIR/REPLACE THE HAND FIRE & BILGE PUMP.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Lifesaving
Issued 23 April 1987 Resolved
PROVIDE 6 ADDITIONAL ADULT LIFE PRESERVERS.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Fire Fighting
Issued 27 March 1985 Resolved
HAVE 50 POUND CO2 BOTTLE FROM ENGINE ROOM FIXED FIRE FIGHTING SYSTEM HYDROSTATICALLY TESTED.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Engineering
Issued 27 March 1985 Resolved
MARK EMERGENCY FUEL SHUT-OFF'S IN CONTRASTING COLORS, WHITE BACKGROUND WITH RED LETTERING.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Electrical
Issued 27 March 1985 Resolved
REMOVE OR PROPERLY CONNECT WIRES THAT ARE LOOSE IN BRIDGE GAUGE CONSOLE.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985

Casualty record · 2

26 April 2008Routine · role: Involved in a Marine Casualty · activity 3194589
18 February 2019Routine · role: Involved in a Marine Casualty · activity 6630109
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record