LADY LUCK

LADY LUCK is a 1976 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in June 2026, along with 51 deficiencies and 1 casualty investigation in 2016.

Records from 2016 to 2026. Most recent: inspection, 3 June 2026.

Built
1976
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL4062
Flag
UNITED STATES
Maury page id
psix-48704

Documentation record

Registered dimensions (L × B × D)41.5 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOMER, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

3 June 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8391426
2 July 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8172270
28 May 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8146684
19 August 2024 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7985006
2 August 2024 Type not recorded
No type recorded · Maritime Safety & Security Team Seattle (91101) · Activity 7973298
18 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7933675
25 August 2021 Annual Inspection · Deficiency Check · Drydock Exam · COI Inspection · Simplified Stability Test · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7297720
5 May 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6952318
29 August 2019 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6697415
13 August 2019 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6724104
19 June 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6451482
27 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6276723
27 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6289813
8 May 2017 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6141686
24 April 2017 Drydock Exam · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6235784
17 November 2016 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6043064
13 November 2016 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6042629
22 June 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5915924

Deficiency record · 51

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2023 Resolved
Ensure proper battery is installed in RLB waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 14 July 2023
Resolution: Verified manufacturer-specified lithium battery installed in water light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2023 Resolved
Provide 02 additional Type I adult life jackets. Vsl restricted to 18 total people.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 14 July 2023
Resolution: Verified two new Type 1 lifejackets with suitable retroflective material and lights with appropriate batteries attached were onboard and marked with vessel's name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023 Resolved
Test loss of power to throttles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 18 June 2024
Resolution: Verified QFAs for throttles
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 August 2021 Resolved
Complete satisfactory COI Renewal Inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2023
Resolution: Conducted annual since vessel has be not operating for so long while waiting for new engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 August 2019 Resolved
Show that the vessels bilge pumps and high water alarms are properly arranged and function as intended.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2019
Resolution: Replaced the aft float switch for the bilge pump and engine room high water alarm unit. All sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 August 2019 Resolved
Vessel crew to provide adequate sea trials / drills to an attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2019
Resolution: Sea trials / drills completed in the presence of an attending CG marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 August 2019 Resolved
Provide a valid CG Certificate of Documentation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2019
Resolved 29 August 2019
Resolution: Vessel rep showed correspondence from NVDC showing proof vessel holds a valid COD.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 August 2019 Resolved
Provide a waste management plan for the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep generated a waste management plan for the vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 August 2019 Resolved
Provide proof of the vessel holding a valid FCC safety certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2019
Resolved 5 July 2023
Resolution: onboard
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 August 2019 Resolved
Provide procedures of an abandon ship drill onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep generated abandon ship procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 August 2019 Resolved
Replace retro-reflective tape on the ring buoy.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep replaced the worn retro-reflective tape on the ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 August 2019 Resolved
Post an inflatable IBA instruction placard onboard the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep posted an IBA instruction placard IVO the mounted location.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 August 2019 Resolved
Provide a means of locking the sewage overboard valve.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep showed adequate means of securing the vessels overboard valve.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 August 2019 Resolved
Provide a ring buoy light w/ 3'-6' of lineand a non-corrosive clip installed near the ring buoy.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 5 July 2023
Resolution: provided
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 August 2019 Resolved
Provide guards around the port and starboard engine drive belts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 5 July 2023
Resolution: installed
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2018 Resolved
Provide training records/logs. 46 CFR 185.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 22 June 2018
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2018 Resolved
Provide emergency training and drill logs. 46 CFR 185.520(f)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 22 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 June 2018 Resolved
Remove dead end wire midships stowage 46 CFR 183.340(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 22 June 2018
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2018 Resolved
Provide weekly inpsectino documentation for survival craft. 46 CFR 185.720
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 22 June 2018
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2018 Resolved
Provide monthly inspection documentation of EPIRB. 46 CFR 185.728
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 22 June 2018
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 June 2018 Resolved
Provide EPIRB registration. 46 CFR 185.604(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 June 2018 Resolved
Provide up to date light list for operational area. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 22 June 2018
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 June 2018 Resolved
Provide current table. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2018
Resolved 22 June 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2018 Resolved
Provide documentation for fire extinguisher servicing. 46 CFR 46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 June 2018 Resolved
Replace expired items from First Aid Kit. 46 CFR 160.041
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 11 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2018 Resolved
Provide Life Jacket donning placards for all types. 46 CFR 185.516
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 19 June 2018 Resolved
Replace burned out accommodation lights. 46 CFR 183.410
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 22 June 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 June 2018 Resolved
Plug hole in fwd ER water tight bulkhead,IWO centerline. 46 CFR 179.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2018 Resolved
Re-attach hanging relay switch for head water pump. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 22 June 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 19 June 2018 Resolved
Double clamp all hoses that require double clamping. 46 CFR 182.450(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 11 July 2018
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 June 2018 Resolved
Engine room air supply vent must be capable of being closed. 46 CFR 182.465
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
14 - Pollution Prevention › 146 - MARPOL Annex VI › Approval for exhaust gas cleaning system
Issued 19 June 2018 Resolved
Install flaps on port and stbd exhaust at waterline. 46 CFR 182.425(a)(2)
Action required: 705 - Other - as specified
Due 19 October 2019
Resolved 5 July 2023
Resolution: engine exhaust has bend to prevent back flow of water
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 19 June 2018 Resolved
Replace worn plastic sea water pipe in way of stb engine fwd mount. 46 CFR 182.40-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 11 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 June 2018 Resolved
Provide required manufacturer's instructions for onboard maintenance of survival craft. 46 CFR 185.702
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 June 2018 Resolved
Replace bubbled seawater hose to head. 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 11 July 2018
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 June 2018 Resolved
Secure seawater supply pump to head. 46 CFR 184.704
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 11 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 June 2018 Resolved
Provide operational hand bilge pump. 46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 11 July 2018
Communications › Radio Communications › EPIRB
Issued 30 August 2017 Resolved
Battery on EPIRB expires 31Aug17. Replace battery. 46 CFR 180.64
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2017
Resolved 27 September 2017
Documentation › Certificates/Documents › FCC SSL
Issued 30 August 2017 Resolved
FCC Station License expired 13MAR2017. 47 CFR 80.13
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 27 September 2017
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 30 August 2017 Resolved
Must have means to conduct post-casualty alcohol testing. 46 CFR 16.201
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 28 September 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 August 2017 Resolved
Label child life preserver with correct number of PFD's 46 CFR 185.604
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 28 September 2017
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 30 August 2017 Resolved
Update emergency procedures to reflect current procedures. 46 185.512
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 27 September 2017
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 30 August 2017 Resolved
Repair loose MSD tank discharge hose. 33 CFR 159.95(a)(1)
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 27 September 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 August 2017 Resolved
Replace holed flame screens for the port and stb emergency fuel shutoffs. 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 5 July 2023
Resolution: installed
Construction/Loadline › Penetrations › Flange Pad
Issued 30 August 2017 Resolved
Re-seal leaking anchor davit. 46 CFR 176.802
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 27 September 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 August 2017 Resolved
Make operational high level alarm in lazarette and properly secure. 46 CFR 176.804(i)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2017
Resolved 28 September 2017
Construction/Loadline › Structures › Deck Plating
Issued 30 August 2017 Resolved
Repair two leaks into the lazarette from the main deck. Contact local Coast Guard prior to applying new repair material. 46 CFR 176.802
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 9 October 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 May 2017 Resolved
Conduct COI exam and underway drills. 46 CFR 176.404
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2017
Resolved 30 August 2017
Construction/Loadline › Hull › Longitudinal Frame
Issued 17 November 2016 Resolved
Must submit repair proposal and make permanent repairs to the hole on the stbd side of the hull.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2016
Resolved 15 August 2017
Engineering › Bilge Water Management System › Hose
Issued 22 June 2016 Resolved
Make emergency bilge pump hose able to reach any bilge and discharge overboard. 46 CFR 182.520(b)
Due 21 July 2016
Resolved 6 July 2016
Engineering › Bilge Water Management System › Hose
Issued 22 June 2016 Resolved
Replace cracked bilge hose in lazarette. 46 CFR 182.510
Due 21 July 2016
Resolved 28 June 2016

Casualty record · 1

13 November 2016Routine · role: Subject of Search and Rescue · activity 6042629
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record