Records from 2016 to 2026. Most recent: inspection, 3 June 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2023
Resolved
Ensure proper battery is installed in RLB waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 14 July 2023
Resolution: Verified manufacturer-specified lithium battery installed in water light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2023
Resolved
Provide 02 additional Type I adult life jackets. Vsl restricted to 18 total people.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 14 July 2023
Resolution: Verified two new Type 1 lifejackets with suitable retroflective material and lights with appropriate batteries attached were onboard and marked with vessel's name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023
Resolved
Test loss of power to throttles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 18 June 2024
Resolution: Verified QFAs for throttles
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 August 2021
Resolved
Complete satisfactory COI Renewal Inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2023
Resolution: Conducted annual since vessel has be not operating for so long while waiting for new engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 August 2019
Resolved
Show that the vessels bilge pumps and high water alarms are properly arranged and function as intended.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2019
Resolution: Replaced the aft float switch for the bilge pump and engine room high water alarm unit. All sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 August 2019
Resolved
Vessel crew to provide adequate sea trials / drills to an attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2019
Resolution: Sea trials / drills completed in the presence of an attending CG marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 August 2019
Resolved
Provide a valid CG Certificate of Documentation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2019
Resolved 29 August 2019
Resolution: Vessel rep showed correspondence from NVDC showing proof vessel holds a valid COD.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 August 2019
Resolved
Provide a waste management plan for the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep generated a waste management plan for the vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 August 2019
Resolved
Provide proof of the vessel holding a valid FCC safety certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2019
Resolved 5 July 2023
Resolution: onboard
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 August 2019
Resolved
Provide procedures of an abandon ship drill onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep generated abandon ship procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 August 2019
Resolved
Replace retro-reflective tape on the ring buoy.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep replaced the worn retro-reflective tape on the ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 August 2019
Resolved
Post an inflatable IBA instruction placard onboard the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep posted an IBA instruction placard IVO the mounted location.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 August 2019
Resolved
Provide a means of locking the sewage overboard valve.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 29 August 2019
Resolution: Vessel rep showed adequate means of securing the vessels overboard valve.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 August 2019
Resolved
Provide a ring buoy light w/ 3'-6' of lineand a non-corrosive clip installed near the ring buoy.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 5 July 2023
Resolution: provided
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 August 2019
Resolved
Provide guards around the port and starboard engine drive belts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 5 July 2023
Resolution: installed
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2018
Resolved
Provide training records/logs. 46 CFR 185.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 22 June 2018
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2018
Resolved
Provide emergency training and drill logs. 46 CFR 185.520(f)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 22 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 June 2018
Resolved
Remove dead end wire midships stowage 46 CFR 183.340(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 22 June 2018
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2018
Resolved
Provide weekly inpsectino documentation for survival craft. 46 CFR 185.720
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 22 June 2018
Documentation › Logs/Records › Logbook (official)
Issued 19 June 2018
Resolved
Provide monthly inspection documentation of EPIRB. 46 CFR 185.728
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2018
Resolved 22 June 2018
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 June 2018
Resolved
Provide EPIRB registration. 46 CFR 185.604(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 June 2018
Resolved
Provide up to date light list for operational area. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 22 June 2018
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 June 2018
Resolved
Provide current table. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2018
Resolved 22 June 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2018
Resolved
Provide documentation for fire extinguisher servicing. 46 CFR 46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 June 2018
Resolved
Replace expired items from First Aid Kit. 46 CFR 160.041
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 11 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2018
Resolved
Provide Life Jacket donning placards for all types. 46 CFR 185.516
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 19 June 2018
Resolved
Replace burned out accommodation lights. 46 CFR 183.410
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 22 June 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 June 2018
Resolved
Plug hole in fwd ER water tight bulkhead,IWO centerline. 46 CFR 179.320(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2018
Resolved
Re-attach hanging relay switch for head water pump. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 22 June 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 19 June 2018
Resolved
Double clamp all hoses that require double clamping. 46 CFR 182.450(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 11 July 2018
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 June 2018
Resolved
Engine room air supply vent must be capable of being closed. 46 CFR 182.465
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
14 - Pollution Prevention › 146 - MARPOL Annex VI › Approval for exhaust gas cleaning system
Issued 19 June 2018
Resolved
Install flaps on port and stbd exhaust at waterline. 46 CFR 182.425(a)(2)
Action required: 705 - Other - as specified
Due 19 October 2019
Resolved 5 July 2023
Resolution: engine exhaust has bend to prevent back flow of water
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 19 June 2018
Resolved
Replace worn plastic sea water pipe in way of stb engine fwd mount. 46 CFR 182.40-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 11 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 June 2018
Resolved
Provide required manufacturer's instructions for onboard maintenance of survival craft. 46 CFR 185.702
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 22 June 2018
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 June 2018
Resolved
Replace bubbled seawater hose to head. 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 11 July 2018
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 June 2018
Resolved
Secure seawater supply pump to head. 46 CFR 184.704
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 11 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 June 2018
Resolved
Provide operational hand bilge pump. 46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2018
Resolved 11 July 2018
Communications › Radio Communications › EPIRB
Issued 30 August 2017
Resolved
Battery on EPIRB expires 31Aug17. Replace battery. 46 CFR 180.64
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2017
Resolved 27 September 2017
Documentation › Certificates/Documents › FCC SSL
Issued 30 August 2017
Resolved
FCC Station License expired 13MAR2017. 47 CFR 80.13
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 27 September 2017
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 30 August 2017
Resolved
Must have means to conduct post-casualty alcohol testing. 46 CFR 16.201
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 28 September 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 August 2017
Resolved
Label child life preserver with correct number of PFD's 46 CFR 185.604
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 28 September 2017
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 30 August 2017
Resolved
Update emergency procedures to reflect current procedures. 46 185.512
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 27 September 2017
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 30 August 2017
Resolved
Repair loose MSD tank discharge hose. 33 CFR 159.95(a)(1)
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 27 September 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 August 2017
Resolved
Replace holed flame screens for the port and stb emergency fuel shutoffs. 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 5 July 2023
Resolution: installed
Construction/Loadline › Penetrations › Flange Pad
Issued 30 August 2017
Resolved
Re-seal leaking anchor davit. 46 CFR 176.802
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 27 September 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 August 2017
Resolved
Make operational high level alarm in lazarette and properly secure. 46 CFR 176.804(i)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2017
Resolved 28 September 2017
Construction/Loadline › Structures › Deck Plating
Issued 30 August 2017
Resolved
Repair two leaks into the lazarette from the main deck. Contact local Coast Guard prior to applying new repair material. 46 CFR 176.802
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 9 October 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 May 2017
Resolved
Conduct COI exam and underway drills. 46 CFR 176.404
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2017
Resolved 30 August 2017
Construction/Loadline › Hull › Longitudinal Frame
Issued 17 November 2016
Resolved
Must submit repair proposal and make permanent repairs to the hole on the stbd side of the hull.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2016
Resolved 15 August 2017
Engineering › Bilge Water Management System › Hose
Issued 22 June 2016
Resolved
Make emergency bilge pump hose able to reach any bilge and discharge overboard. 46 CFR 182.520(b)
Due 21 July 2016
Resolved 6 July 2016
Engineering › Bilge Water Management System › Hose
Issued 22 June 2016
Resolved
Replace cracked bilge hose in lazarette. 46 CFR 182.510
Due 21 July 2016
Resolved 28 June 2016