Records from 1985 to 2019. Most recent: inspection, 1 May 2019.
Documentation record
Registered dimensions (L × B × D)35.6 ft × 11.9 ft × 6.7 ft
Registered tonnagegross 21 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES INC · SEATTLE, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSALTERY COVE, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 18 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
1 May 2019
Uninspected Passenger Vessel
Physical examination · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 6675643
8 May 2017
Type not recorded
No type recorded · Station Ketchikan · USCG Arctic District (CGD-A) · Activity 6141876
13 April 1993
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1353445
7 April 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1258695
25 March 1992
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1262792
6 May 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1217501
26 March 1991
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1234408
1 March 1990
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 916952
18 September 1989
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1042344
10 April 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1343037
29 March 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1204657
31 March 1988
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1301365
4 June 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1000785
18 May 1987
Hull Examination · Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1000784
6 May 1986
Re-Inspection · Credit Drydock
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1303296
9 May 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 978049
3 April 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 981286
Navigation
Issued 25 March 1992
Resolved
MOVE ANCHOR LIGHT SO IT CAN BE SEEN 360 DEGREE AND DOES NOT OPERATE WHEN THE RUNNING LIGHTS ARE ON.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Accommodation/Occupational Safety
Issued 25 March 1992
Resolved
REPLACE HANDLE ON "Y" VALVE FOR MSD IN HEAD.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Construction/Loadline
Issued 25 March 1992
Resolved
RE-LABEL BILGE MANIFOLD.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Engineering
Issued 25 March 1992
Resolved
MAKE REMOTE FUEL SHUT OFF VALVES OPERABLE FROM OUTSIDE OF THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Construction/Loadline
Issued 26 March 1991
Resolved
PROVIDE DOUBLE CLAMP FOR FLEX CONNECTION ON SEA VALVE.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Unknown
Issued 26 March 1991
Resolved
PROVE SATISFACTORY OPERATION OF MAIN ENGINE AND ENGINE DRIVEN BILGE PUMP.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Documentation
Issued 26 March 1991
Resolved
CONDUCT STABILITY TEST OR PROVE SISTER VESSEL STATUS FOR STABILITY.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Construction/Loadline
Issued 29 March 1989
Resolved
PROVIDE HATCH RETENTION DEVICE FOR LAZARETTE DECK HATCH.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Engineering
Issued 29 March 1989
Resolved
REPLACE PORT AND STARBOARD FLEXIBLE FUEL FILL HOSES, DOUBLE CLAMPING BOTH ENDS OF HOSE CONNECTIONS.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Fire Fighting
Issued 29 March 1989
Resolved
PROVIDE PROOF OF HYDROSTATIC TEST OR PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 6 May 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 May 1986
Resolved 6 May 1986