CATCH MY DRIFT

CATCH MY DRIFT is a 1976 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1984, most recently in May 2026, along with 266 deficiencies, 1 operational control and 6 casualty investigations between 2010 and 2013.

Records from 1984 to 2026. Most recent: inspection, 4 May 2026.

Built
1976
Last inspected
4 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD3228
Flag
UNITED STATES
368269670
Maury page id
psix-48707

Inspections, by type

…with no type recorded14
Years with a record 42 calendar years (1984–2026)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)74.7 ft × 21.7 ft × 7.1 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFT. LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 22 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN3228MMSI 368269670 · active · compulsorily equipped · granted 26 July 2022, expires 26 July 2032
WDA6858MMSI 366836870 · expired · compulsorily equipped · granted 29 January 2002, cancelled 31 March 2012 · licensed under a name not among this hull’s recorded names (not shown)
WBJ5653MMSI not assigned · expired · compulsorily equipped · granted 2 June 1997, cancelled 6 October 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BLUE MANA Passenger (Uninspected) · MISLE 105348 · 19 June 2012 · activity 4350943

Inspection history · 91

4 May 2026 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8357882
11 August 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8202096
16 October 2024 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8019906
14 August 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7980379
9 May 2023 Annual Inspection · In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7683433
19 October 2022 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7580598
3 August 2022 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7523765
14 May 2021 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7190575
12 November 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7093825
29 October 2020 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7086640
19 October 2020 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7080835
30 March 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933311
21 May 2019 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6689340
1 November 2018 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6568640
19 June 2018 Internal Structural Exam · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6449207
5 August 2017 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 6232337
6 June 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6166581
16 November 2016 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6042096
20 April 2016 COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5856476
15 October 2015 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5744070
21 July 2015 Annual Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5191071
16 October 2014 Drydock Exam · Deficiency Check · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5010941
19 June 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4350943
19 June 2012 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4358338
13 June 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4343862
11 June 2012 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4337749
12 May 2012 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 4309141
28 February 2012 In-Service Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4274429
17 August 2011 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4142586
1 August 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4102347
5 July 2011 Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4069584
4 July 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4072446
8 February 2011 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3941250
5 January 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3658439
27 July 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3544187
15 July 2008 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3267344
11 December 2007 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3113301
9 May 2007 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2925813
3 January 2006 In-Service Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2559860
1 December 2005 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2542605
13 October 2005 Uninspected Passenger Vessel
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2514417
13 May 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2356959
7 April 2005 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2327760
1 April 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2343465
6 April 2004 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2038507
10 December 2003 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1961916
31 January 2003 Administrative Inspection · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1756194
17 December 2002 Administrative Inspection · MARPOL Annex V Examination · In-Service Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1719902
10 December 2002 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1716881
26 March 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1608694
15 January 2002 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1478745
23 March 2001 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1427992
17 May 2000 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1049967
18 April 2000 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1403108
23 April 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1469897
22 March 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1434838
17 June 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1126697
5 May 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1418343
29 May 1997 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 773445
19 May 1997 Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1091388
27 March 1997 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1380807
25 April 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1081273
26 April 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1145499
21 March 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1180065
29 April 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1167977
29 April 1993 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1149101
5 March 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1150054
26 March 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 951621
5 March 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1254721
23 April 1991 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 931150
20 March 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1243365
28 February 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 926048
4 May 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 916736
2 April 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 923454
6 July 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1201861
4 May 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1037862
9 March 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 886525
28 April 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1344400
31 March 1988 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 994622
27 January 1988 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1014089
17 December 1987 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1006147
16 April 1987 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1328426
6 December 1986 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1003548
27 August 1986 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 989650
26 March 1986 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 998314
13 March 1986 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1304030
27 March 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 980880
6 March 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1285566
6 March 1985 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1290066
6 March 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1294906
16 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973927

Deficiency record · 266

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 May 2026 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. The number of lifejackets was improperly marked in all locations where they were stowed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 18 May 2026
Resolution: All life jacket stowage properly labled for the size and number of PFD's stored.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 4 May 2026 Resolved
Excessive salt buildup in bilges is causing galvanic corrosion. Windows were found leaking by on the starboard main deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 15 May 2026
Resolution: Windows re-glazed and bilges cleared of salt accumulation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 Resolved
The distribution panel on the aft main deck would not latch closed, and the distribution panel in the engine room was not labeled for all circuits controlled. 46CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 14 May 2026
Resolution: All circuits labled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 Resolved
All electrical installation shall be to the satisfaction of the OCMI. The v-belt on the port generator serving the water pump was loose. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 15 May 2026
Resolution: Water pump adjusted to tighten v-belt.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 Resolved
All electrical installation shall be to the satisfaction of the OCMI. The light receptacle wired from the bridge house was found exposed and adrift. Four floodlights were found cracked and inoperable.46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 15 May 2026
Resolution: Lights replaced and secured to bridge house.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 Resolved
All electrical installation shall be to the satisfaction of the OCMI. The voltage regulator box mounted on the port generator was free from it’s mount. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 19 May 2026
Resolution: OEM voltage box replaced in kind and secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 Resolved
All electrical installation shall be to the satisfaction of the [name withheld] outlets on the port aft interior accommodation space was protruding from bulkhead. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 15 May 2026
Resolution: Outlet refastened flush to bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 Resolved
All electrical installation shall be to the satisfaction of the [name withheld] connections (plugs) were being utilized for permanently fitted equipment in tank room on the overhead. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 15 May 2026
Resolution: Wired permanently attached in a suitable conduit box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2026 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. All life rings were not approved for use for a vessel of 74 feet in length.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 14 May 2026
Resolution: Lifebouys replaced with proper size bouys, labled, and outfitted properly.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 May 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Fuel was accumulated in the heat shield of the starboard generator fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 14 May 2026
Resolution: Heat sheilds cleaned and free of fuel.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 May 2026 Resolved
Blow-by pipes were allowing crank case vapors from all combustion engines to freely flow into engine space. Arrest vapor and mist with an effective means.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 14 May 2026
Resolution: All engines fitted with purpose built intakes that accept crank case blowby lines.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 11 August 2025 Resolved
Each survival craft required on a vessel by this part must meet one of the following: For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. All life floats were missing CG approval placards and were damaged. Vessel is not permitted to operate outside of 3NM until all life floats are replaced. 46 CFR 180.200(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 23 September 2025
Resolution: Vessel rep received three brand new life floats with Coast Guard approval placards and installed to the vessel. Vessel permitted to operate outside of 3NM.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 August 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Five adult life jackets were found in-serviceable and requires replacement. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 13 August 2025
Resolution: Inservicable life jackets were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 August 2025 Resolved
Each lifeline on a ring life buoy must have a breaking strength of at least 5 kilonewtons (1,124 pounds). MIs observed the throw line attached to the top, port side life ring buoy deteriorated and incorrectly tied to the float light. 46 CFR 180.70(c)(5) 46 CFR 18.70(c)(5)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 12 September 2025
Resolution: Photo evidence of port side life ring buoy throw line tied to the float light was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 11 August 2025 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. MIs observed hydraulic fittings on the anchor wench corroded beyond repair. 46 CFR 184.300
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 18 September 2025
Resolution: Hydraulic fittings will be replaced in late October, once vessel is pulled out at ship yard.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 11 August 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MIs observed emergency instructions were not posted at the operating station. 46 CFR 185.510(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 12 September 2025
Resolution: Picture evidence was received of emergency instructions posted onboard.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 August 2025 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel did not have a monthly inspection log of firefighting equipment. 46 CFR 176.810(b)(1)(ii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 22 September 2025
Resolution: Photo evidence was received of monthly inspections for each fire extinguisher onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 August 2025 Resolved
...on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. The pressure gauge did not operate while the fire pump was energized. 46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 19 August 2025
Resolution: The perssure gauge was replaced and is operable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2025 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have a solder lug on each conductor. MIs observed exposed wires that were not capped off on the topside deck, above the bridge, and in the engine room, including; a missing light bulb without installed casing above starboard MDE. 46 CFR 183.340(g)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 20 September 2025
Resolution: Video and photo evidence provided of capped off wires and casing around newly installed light bulb above the starboard MDE.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 August 2025 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matte black inboard screens and meet the requirements of § 84.15. The housing case to the navigation lights are not matte black. 33 CFR 84.05(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 19 August 2025
Resolution: The housing case to the navigation lights were painted matte black.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 August 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer 'in Charge, Marine Inspection. MIs observed a floodlight on the topside deck above the bridge to be broken off and not in use. Floodlight is to be replaced or removed. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2025
Resolved 13 August 2025
Resolution: Floodlight above wheel house was removed and wires capped off.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2024 Resolved
Materials not covered by standards in this subchapter may be inspected IAW standards acceptable to OCMI as good marine practice. Excessive salt build up in bilges due to previously replaces leaking hatches which leads to galvanic corrosion. Remove salt buildup and other materials from all bilge spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2024
Resolution: Removed excessive salt/debris from bilge.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 August 2024 Resolved
A hatch exposed to the weather must be watertight. All weather-deck hatches were unable to be properly secured to watertight condition. 46 CFR § 179.360 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2024
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 14 August 2024 Resolved
Except as provided in paragraph (c) of this section, each vessel must comply with the Type II subdivision and damage stability requirements of §§ 171.070 through 171.073 and 171.080 of this chapter. Bulkhead between V-berth and [name withheld] is wasted and has multiple holes; bulkhead does not meet Type II subdivision and damage stability requirements. 46 CFR § 179.212 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 August 2024 Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. Hydraulic steering pump at the helm is leaking and must be fixed. 46 CFR § 182.610 (a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2024
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 14 August 2024 Resolved
A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station if:(1) The vessel is self-propelled;(2) The vessel has an oceans, coastwise, limited coastwise, or Great Lakes route; and(3) The vessel carries more than 49 passengers. Vessel has non-operational radar that must be replaced prior to operating with more than 49 passengers. 46 § 184.404 (a)(1)-(3)
Action required: 705 - Other - as specified
Resolved 26 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 August 2024 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. Pressure gage is missing from the fire pump. 46 CFR § 181.10-1 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 14 August 2024 Resolved
The float-free link required by § 180.130(a)(1) must be: Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Replace float-free links which are missing ID tags for both life floats. 46 CFR § 180.137 (b) (2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 August 2024 Resolved
... A vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. The bell or gong or both may be replaced by other equipment having the same respective sound characteristics, provided that manual sounding of the prescribed signals shall always be possible. Vessel's sounding horn is non-operational. 33 CFR § 83.33 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 August 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Remove loose-end wires on starboard engine left behind from the old alternator. 46 CFR § 183.200 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 May 2023 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. MIs found weld on hydraulic steering stanchion cracked. Vessel is required to repair to Marine Inspector standard. 46 CFR 182.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2023
Resolution: Weld repairs conductied to satisfaction of the MI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2023 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. MIs found 32 life preservers not suitable for service. Vessel is required to obtain new life preservers and replace. 46 CFR 180.25-5(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2023
Resolution: 32 new life jackets are on board and marked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2023 Resolved
Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. MIs observed a visible hole through the exhaust piping on the starboard side. Vessel is required to repair to MI’s satisfaction. The hose clamp from generator exhaust is allowing exhaust gasses to be vented into the engine room. Replace hose clamp and ensure gastight. 46 CFR 182.20-20(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2023
Resolution: Welded repairs to the satisfaction of the MI
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 May 2023 Resolved
Inspect all railings and bulwarks and their attachment to the hull structure. MIs noticed that the welding between the railing post and hull was cracked. Vessel is required to reweld. 46 CFR 176.25-5(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2023
Resolution: Weld repairs made to the saisfaction of the MI
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 May 2023 Resolved
If both the required fixed power bilge pumps are electrically driven, two generators shall be provided. Vessel’s second generator is not operational. Vessel is required to repair generator. 46 CFR 183.05-10(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2023
Resolution: Replaced fuel pump, tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 May 2023 Resolved
At each inspection... the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Remove excess oil in machinery space. 46 CFR 176.25-50
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2023
Resolution: Oil removed, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 May 2023 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Bulkhead penetrations for wires were found between midship and forward stowage compartments. Remove wood veneer and ensure proper bulkhead penetration seals. 46 CFR 181.20-35
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2023
Resolution: BLKHD penetrations sealed, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2023 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] observed exposed/dead-end wiring for equipment of unknown origin. Remove or secure excess wiring. Outlet cover in midship stowage space missing. Replace cover. Broken wires on starboard generator sensor. Replace wires. Excess/broken lighting fixtures. Either replace or remove. Breaker panel in engine room cannot be secured, nor are the breakers labeled. Vessel must repair panel so it can be secured and label all breakers with corresponding circuits. Paralleling transformer is not mounted. Must remount paralleling transformer. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 23 May 2023
Resolution: excessive not in use wiring removed, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 9 May 2023 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: “Emergency Exit. Keep Clear.” Emergency exit in midship storage space is still marked with escape markings despite the exit being welded closed permanently. Remove exit markings. 46 CFR 185.30-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2023
Resolution: Egress markings covered over, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 May 2023 Resolved
All vessels shall be fitted with such ground tackle and hawsers as deemed necessary by the Officer in Charge, Marine Inspection. MIs observed hydraulic lines dry rotted and cracked in the forward winch area of the anchor and in addition heavy corrosion of several pieces of hardware. Vessel is required to replace dry rotted, cracked, and corroded materials. 46 CFR 184.10-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2023
Resolution: Hydraulic winch hose and fittings replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 May 2023 Resolved
At each initial and subsequent inspection … the marine inspector shall examine and test the main and auxilliary steering apparatus … to determine that its condition is satisfactory. MIs observed severe chaffing on the steering hydraulic line. Hydraulic line requires replacement. 46 CFR 176.25-35
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 May 2023
Resolution: Hydraulic line replaced, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2023 Resolved
Electrical equipment and circuits which are a necessary part of any system vital to the safe navigation of the vessel … shall be subject to certain additional requirements as determined by the Officer in Charge, Marine Inspection. MI’s discovered that the starboard side alternator is inoperable and hanging in position, but not necessary to for the safe operation of the vessel. This alternator requires one of the following: 1) outright removal, 2) replaced and placed into operable condition, or 3) not replaced but safely secured to vessel to MI’s satisfaction. 46 CFR 183.01-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 May 2023
Resolution: Port and Starboard alternator's removed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2023 Resolved
Installation shall be in accordance with 182.15-15: Exhaust piping shall be led to the point of escape with … . It shall be gastight throughout its length. Port exhaust ventilation box has severe corrosion on it. Exhaust ventilation box needs to be repaired. Generator intake/exhaust hose requires replacement. Replace generator intake/exhaust hose. 46 CFR 182.20-15
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2023
Resolution: Generator exhaust hose replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 May 2023 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguisher in the portside engine room is unmounted. Vessel must mount portable extinguisher. 46 CFR 181.30-10(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2023
Resolution: Mount replaced, all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 May 2023 Resolved
Vessels shall be equipped with a suitable number of portable battery lights. The portable battery in the forward compartment is non-operational. Vessel must renew portable battery light to operational condition. 46 CFR 184.30-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2023
Resolution: Batt's replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 May 2023 Resolved
The life line shall be properly secured around the sides and ends of the life float or buoyant apparatus. MIs discovered that all lifelines on all lifebuoys, floating water lights, lifefloats, and buoyant apparatuses are degraded. Vessel must replace and renew all life lines. 46 CFR 180.15-5(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2023
Resolved 15 June 2023
Resolution: Received pictures, all lines replaced on lifesaving equipment. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2023 Resolved
Before getting underway, the master of each vessel subject to this subpart shall ensure that … , instructive placards … are provided. Vessel has two different types of Type 1 lifejackets, but vessel only has instructive donning placards for one type. Vessel must have instructive donning placards for each type of Type 1 life jacket on board. 46 CFR 185.25-1(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2023
Resolution: Placards replaced, all sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 May 2023 Resolved
The inspection shall … also be such as to insure that the materials, workmanship and condition of all parts of the vessel and its machinery and equipment are in all respects satisfactory for the service intended. The forepeak watertight hatch lower bushing is in need or replacement. Vessel must replace this lower bushing. 46 CFR 176.05-5(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 May 2023
Resolution: Hatch replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 May 2021 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous be corrected, MI found excessive oil residue on engine room bulkheads and ceiling and oil saturated air filter for both main diesel engines creating a fire hazard. Wipe all surfaces, engines and components clean and replace both air filters. 46 CFR 176.25-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2021
Resolved 28 May 2021
Resolution: Crew cleaned all engine room surfaces. Will keep an eye for any leaks. All Sat
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 14 May 2021 Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. Bilge remote valve was seized due to corrosion on deck through hull preventing proper operation and impeding system from taking suction from FWD peak. Replace valve and proof proper operation of bilge suction and system. 46 CFR 182.25-5(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2021
Resolved 28 May 2021
Resolution: Crew replaced old valve with new one. Operational check was performed, test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2021 Resolved
Remote fuel shut-off stations shall be marked on both sides in at least 1-inch letters indicating purpose of the valve and direction of operation. Fuel shut-off label was missing. Replace with new sign. 46 CFR 185.30-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2021
Resolved 28 May 2021
Resolution: Crew labeled both benches in front of the fuel shut off. All sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 May 2021 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous be corrected, MI found Stbd side pump and raw water strainer loose due to corroded bolts mounting surface. Reattached pump and strainer to mounting surface. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2021
Resolved 28 May 2021
Resolution: Crew fastened Strainer and pump to Mounting. All sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2020 Resolved
starboard side cutlass bearing has melted line in way of the bearing and an observation of the condition of the bearing could not be determined. Make ready for inspection.
Action required: 705 - Other - as specified
Resolved 2 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 October 2020 Resolved
Repair or replace inoperable bilge pump. 46CFR176.05-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2020
Resolved 2 November 2020
Resolution: Bilge pump replaced and tested. Test Sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020 Resolved
Replace expired alcohol test strips. 46CFR4.06(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 October 2020
Resolved 2 November 2020
Resolution: New alcohol testing strips were purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 October 2020 Resolved
Replace 4 expired distress flares. 46CFR180.35-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2020
Resolved 19 October 2020
Resolution: Vessel purchased new and discraded the expired flares.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 May 2019 Resolved
Replace battery on lifefloat strobe, port side second in.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
Resolution: Battery replaced with proper type.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 May 2019 Resolved
EPIRB battery is expired. Replace expired battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
Resolution: Owner replaced EPIRB with brand new EPIRB and registered the new device under same registration of previous EPIRB. 2DCC4 46BA2 FFBFF
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 May 2019 Resolved
EPIRB hydrostatic release is expired. Replace with new hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
Resolution: New hydrostatic release was installed for EPIRB.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 November 2018 Resolved
Repair cracked handrails where they meet the deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2018
Resolution: Cracks in handrails have been repaired by re-welding to the deck.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 November 2018 Resolved
Repair inset on port quarter side shell that has been patched when bondo. Inset was deep enough to cause metal to tear and breach side shell.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2018
Resolution: Owner had welder crop and renew side shell.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 November 2018 Resolved
Repair hole found in port side stern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2018
Resolution: Owner cropped and renewed metal in stern.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 November 2018 Resolved
Repair cracks on both sides of the bow pulpit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2018
Resolution: Owner had welder re-weld both sides of bow pulpit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2018 Resolved
Clean two compartments just forward of steering compart and make ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2018
Resolution: Cleaned compartments and made ready for inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 June 2018 Resolved
Expired battery needs to be replaced. light inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2018
Lifesaving › Lifebuoys › Serviceable
Issued 20 June 2018 Resolved
wrong type and unserviceable ring buoy taken out of service and replaced with a new serviceable ring buoy.
Due 20 June 2018
Resolved 20 June 2018
Documentation › Certificates/Documents › FCC SSL
Issued 6 June 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 30 June 2017
Resolution: Provided valid FCC Station License.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 6 June 2017 Resolved
Provide Valid FCC Bridge to Bridge Certificate. 47 CFR 80.1005
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 30 June 2017
Resolution: Provided valid FCC Bridge to Bridge Certificate.
Electrical › Electric Supply System (service) › Cable
Issued 6 June 2017 Resolved
Remove or cap dead-end wires in STBD battery and in bridge. 46 CFR 183.05-50
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 30 June 2017
Resolution: Removed dead-end wires in STBD battery and in bridge.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2017 Resolved
Provide visual high level alarm for aft crew space. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 30 June 2017
Resolution: Provided visual high level alarm for aft crew space.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 June 2017 Resolved
Relabel lifejacket capacity. 46 CFR 180.25-10
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 30 June 2017
Resolution: Relabeled lifejacket capacity.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 6 June 2017 Resolved
Provide Alcohol test strips.
Action required: 705 - Other - as specified
Resolved 6 June 2017
Resolution: Vessel owner provided new test strips prior to completion of the inspection.
Engineering › Steering Gear System › Rudder Stock
Issued 16 November 2016 Resolved
Repair/renew steering tie bracket. Prior to DD/ISE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2016
Resolved 21 November 2016
Resolution: Renewed steering tie bracket.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 November 2016 Resolved
Replace plastic zip ties on electrical wires with metalic brackets in STBD side berthing compartment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2016
Resolved 21 November 2016
Resolution: Zip ties on electrical wires with metalic brackets were replaced with metalin STBD side berthing compartment.
Stability › Watertight Integrity › General
Issued 16 November 2016 Resolved
Space going from steering room to engine compartment to pass wires trhough needs to meet watertight requirements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2016
Resolved 21 November 2016
Resolution: Space going from steering room to engine compartment to pass wires through has meet watertight requirements.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 April 2016 Resolved
provide 06 childrens and 09 adult lifejackets. Damaged lifejackets were removed from vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Resolution: New lifejackets were placed on vessel and properly stenciled prior to completing the exam.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 April 2016 Resolved
Remove wing nuts from terminal fittings on engine batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 5 May 2016
Resolution: Crew removed wing nuts from terminal fittings on engine batteries.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 April 2016 Resolved
Provide ring buoy retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 5 May 2016
Resolution: Crew provided ring buoy retro reflective tape.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 April 2016 Resolved
Provide ring buoy water light clip.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 5 May 2016
Resolution: Crew provided ring buoy water light clip.
Engineering › Feedwater/Condensate Water System › Piping
Issued 29 October 2014 Resolved
Strap/secure potable water hose in overhead.
Action required: 705 - Other - as specified
Resolved 13 November 2014
Stability › Watertight Integrity › General
Issued 29 October 2014 Resolved
Make wx deck scuttles water tight.
Action required: 705 - Other - as specified
Resolved 13 November 2014
Construction/Loadline › Structures › Deck Plating
Issued 29 October 2014 Resolved
Clean and remove all bilge debri from water tank and sewage compartment bilges.
Action required: 705 - Other - as specified
Resolved 4 November 2014
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 29 October 2014 Resolved
Provide repair proposal for (2) cracks in port SSDG mounting frames.
Action required: 705 - Other - as specified
Resolved 4 November 2014
Construction/Loadline › Structures › Deck Plating
Issued 29 October 2014 Resolved
Plug holes (2) in both main deck heads IWO toilet drains.
Action required: 705 - Other - as specified
Resolved 4 November 2014
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 October 2014 Resolved
Provide repair proposal for wasted fuel tank bulkhead.
Action required: 705 - Other - as specified
Resolved 23 October 2014
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 October 2014 Resolved
Have fuel tank cleaned and gas free by a marine chemist.
Action required: 705 - Other - as specified
Resolved 23 October 2014
Electrical › Electric Generation Source (service) › Generator
Issued 20 October 2014 Resolved
Provide a install proposal with all specs for the port SSDG replacement.
Action required: 705 - Other - as specified
Resolved 13 November 2014
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 October 2014 Resolved
Make all thru-hull fittings @ waterline avail for inspection.
Action required: 705 - Other - as specified
Resolved 23 October 2014
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 20 October 2014 Resolved
Replace both cutlass bearings.
Action required: 705 - Other - as specified
Resolved 4 November 2014
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 19 June 2012 Resolved
Show proper operation of port engine electronic controllers while underway, in the presents of a USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2012
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 19 June 2012 Resolved
Provide written report of failed port engine electronic controller component.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2012
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 June 2012 Resolved
Make available for inspection or replace the hydraulic steering hose feed line to the STBD MDE gear driven pump.
Action required: 705 - Other - as specified
Due 20 June 2012
Resolved 14 June 2012
Stability › Weathertight Integrity › General
Issued 14 June 2012 Resolved
Plug all holes in pilothouse console.
Action required: 705 - Other - as specified
Due 14 June 2012
Resolved 14 June 2012
Engineering › Fuel Oil Service System › Hose
Issued 13 June 2012 Resolved
Conduct a thorough check of all fuel service line fittings, hoses, and racors within system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 13 June 2012 Resolved
Remove all fuel and oily water from engine room bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 June 2012 Resolved
Make available for inspection the STBD MDE exhaust outlet IWO turbo charger to the satisfaction of a USCG marine inspector.
Action required: 705 - Other - as specified
Due 20 June 2012
Resolved 14 June 2012
Engineering › Bilge Water Management System › Interface Detector
Issued 8 June 2012 Resolved
Show proof of operation of the bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2012
Electrical › Electric Generation Source (service) › Generator
Issued 8 June 2012 Resolved
Show proof of operation of the #1 SSDG under load.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Electrical › Electric Generation Source (service) › Generator Cable
Issued 8 June 2012 Resolved
Make electrical repairs to #2 SSDG. Generator is arcing from the bottom of the control box.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Engineering › Fuel Oil Service System › Filter
Issued 8 June 2012 Resolved
Remove fuel from the #2 MDE racor bowl and make available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 June 2012 Resolved
Make repairs and properly secure #1 MDE battery switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 June 2012 Resolved
Provide guards for both MDE shafts.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 13 June 2012
Electrical › Electrical Distribution System (service) › Switch
Issued 8 June 2012 Resolved
Label the following engine room switches: Bilge pump, fire pump, and the knife switch on aft port bulkhead IWO 24v controller.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 13 June 2012
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 8 June 2012 Resolved
Replace or make available for inspection both MDE's j/w cooler inlet and outlet hoses.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 13 June 2012
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 June 2012 Resolved
Conduct u/w drills of MOB and fire drill with USCG marine inspector.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 14 June 2012
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 June 2012 Resolved
Provide FCC radio telephony certificate.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 21 June 2012
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 8 June 2012 Resolved
Provide FCC bridge to bridge certificate.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 21 June 2012
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 June 2012 Resolved
Provide original COI onboard vessel.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 26 June 2012
Stability › Watertight Integrity › General
Issued 8 June 2012 Resolved
Plug the two holes in the pilot house fwd corners, port and stbd side.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 13 June 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 8 June 2012 Resolved
Remove or properly terminate dead end cable in pilothouse overhead fwd.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 13 June 2012
Stability › Watertight Integrity › General
Issued 8 June 2012 Resolved
Provide cap for anchor line hauser fitting.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 13 June 2012
Electrical › Electric Generation Source (service) › Generator Cable
Issued 8 June 2012 Resolved
Provide a service report from a certified marine electrician on the #2 SSDG electrical system, with insulation resistance measurements. Replace any cracked, frayed, or damaged cables as original.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 26 June 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 8 June 2012 Resolved
Remove all electrical cables as high as possible from the bilge and properly chaft/insulate from any metal objects.
Action required: 705 - Other - as specified
Due 26 June 2012
Resolved 21 June 2012
Engineering › Fuel Oil Service System › Piping
Issued 8 June 2012 Resolved
Make repairs to the port MDE fuel return line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2012
Construction/Loadline › Structures › Deck Plating
Issued 17 February 2011 Resolved
Crop and renew wasted and holed main deck IWO starboard toilet.
Due 24 February 2011
Resolved 24 February 2011
Construction/Loadline › Penetrations › Weld
Issued 17 February 2011 Resolved
V-out and weld areas identified on starboard exhaust piping and bulkhead.
Due 24 February 2011
Resolved 24 February 2011
Construction/Loadline › Structures › Deck Plating
Issued 17 February 2011 Resolved
Crop and renew as original wasted and holed deck plating, center line, IWO doubler plate. Remove doubler plate.
Due 24 February 2011
Resolved 24 February 2011
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 8 February 2011 Resolved
Replace strut bearings on port and stbd tail shafts.
Action required: 705 - Other - as specified
Resolved 16 February 2011
Stability › Unintentional Flooding › General
Issued 8 February 2011 Resolved
Crop and renew holed pipe for sink/galley drain on port side in rudder room.
Action required: 705 - Other - as specified
Resolved 17 February 2011
Stability › Unintentional Flooding › General
Issued 8 February 2011 Resolved
Crop and renew holed pipe for water line in stbd side rudder room
Action required: 705 - Other - as specified
Resolved 24 February 2011
Construction/Loadline › Penetrations › Valve Flange
Issued 8 February 2011 Resolved
Prove proper operation of through hull valve, salt water intake on port main engine.
Action required: 705 - Other - as specified
Resolved 16 February 2011
Construction/Loadline › Hull › Bracket
Issued 8 February 2011 Resolved
Repair two cracked welds IWO generator, stbd side inboard engine room.
Action required: 705 - Other - as specified
Resolved 17 February 2011
Engineering › Bilge Water Management System › Piping
Issued 8 February 2011 Resolved
Crop and renew holed pipe to bilge system in forepeak.
Action required: 705 - Other - as specified
Resolved 17 February 2011
Stability › Weathertight Integrity › General
Issued 8 February 2011 Resolved
Provide cover for anchor line deck fitting.
Action required: 705 - Other - as specified
Resolved 17 February 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 February 2011 Resolved
Properly label lifebuoys on port and stbd side with name of vessel IAW 46 CFR 185.604.
Action required: 705 - Other - as specified
Resolved 16 February 2011
Construction/Loadline › Hull › Strut/Cross Tie
Issued 8 February 2011 Resolved
Make proper repairs to holed strut bearing on port side.
Action required: 705 - Other - as specified
Resolved 17 February 2011
Construction/Loadline › Structures › Deck Plating
Issued 8 February 2011 Resolved
Crop and renew wasted overhead in rudder room IWO the heads.
Action required: 705 - Other - as specified
Resolved 24 February 2011
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2010 Resolved
Crop out port side plate under port shaft boot and replace IAW USCG NVIC/ABS standards. Ensure plate insert is at least 18" X 18". Plate is 4-6" passed frame member. Plate is original thickness/specification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 January 2010 Resolved
Clean out 2nd compartment (V-berth) and make available for USCG inspection (currently heavy salt deposit in bilge).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2010
Construction/Loadline › Hull › Hull Plating
Issued 5 January 2010 Resolved
Provide gauging report for port and starboard hull under shaft boots.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2010
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 5 January 2010 Resolved
Crop to good metal and replace as original leading edge of shaft tube IWO shaft boot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2010
Construction/Loadline › Structures › Scuttle
Issued 5 January 2010 Resolved
Correct 03 CG-835s that were due at dry dock (hatch frame port side, flex hose port exhaust and service/repair MSD tank).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2010
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 January 2010 Resolved
Crop out frames that were replaced and use as-original size t-bar or request to use 3" X 2" t-bar.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2010
Resolution: Owner requested to use larger t-bar because they are having difficulty finding a source of supply.
Construction/Loadline › Hull › Hull Plating
Issued 5 January 2010 Resolved
Once area is proper and ready for insert contact USCG for fit-up approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 27 July 2009 Resolved
Provide an additional B-II fire extinguisher IAW 46 CFR 181.30-1(a) table in Subchapter "T" prior to March 11, 1996, in engine room.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 13 August 2009
Documentation › Certificates/Documents › FCC SSL
Issued 27 July 2009 Resolved
Provide FCC Bridge-to-Bridge onboard.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 13 August 2009
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 July 2009 Resolved
Provide updated tide tables, tidal currents and US Coast pilot onboard Vsl.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 13 August 2009
Lifesaving › Lifefloat › Lifeline
Issued 27 July 2009 Resolved
Provide lifeline on all lifefloats IAW 46 CFR 160.010.
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 13 August 2009
Stability › Watertight Integrity › General
Issued 27 July 2009 Resolved
Make all hatches watertight (fwd, steering compartment and aft compartment found with 8"-1.5' of water in bilge).
Action required: 705 - Other - as specified
Due 13 August 2009
Resolved 13 August 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 July 2009 Resolved
At dry-dock replace port flexible coupler in aft compartment on port exhaust.
Action required: 705 - Other - as specified
Due 31 December 2009
Resolved 13 January 2010
Stability › Watertight Integrity › General
Issued 27 July 2009 Resolved
At dry dock make permanent repairs to port aft compartment hatch frame *currently it is cracked in three places).
Action required: 705 - Other - as specified
Due 31 December 2009
Resolved 14 January 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 27 July 2009 Resolved
Service/make proper repairs to MSD system so that system does not leak in aft compartment, at dry-dock.
Action required: 705 - Other - as specified
Due 31 December 2009
Resolved 14 January 2010
Fire Fighting › Fire Pumps › Capacity
Issued 27 July 2009 Resolved
Provide gage IAW 46 CFR 181.10-1(c) in old "T" showing not less than 60 psi at pump outlet.
Action required: 705 - Other - as specified
Due 26 August 2009
Resolved 19 August 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 December 2007 Resolved
Submit repair proposal; crop and renew port MDE exhaust piping. NDT installation in the presence of a Coast Guard Inspector.
Action required: 705 - Other - as specified
Due 21 December 2007
Resolved 21 December 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 12 December 2007 Resolved
Prove proper operation of bilge high water alarms, de-watering pump, and starboard Generator.
Action required: 705 - Other - as specified
Due 12 December 2007
Resolved 21 December 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 December 2007 Resolved
Remove all dead end wiring.
Action required: 705 - Other - as specified
Due 12 December 2007
Resolved 21 December 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 December 2007 Resolved
Properly mark portside ring life buoy.
Action required: 705 - Other - as specified
Due 12 December 2007
Resolved 21 December 2007
Communications › Radio Communications › EPIRB
Issued 9 May 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 23 May 2007
Resolution: fax
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 9 May 2007 Resolved
Provide complete First Aid Kit onboard.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 23 May 2007
Resolution: fax
Operations/Management › Drills/Instruction › Fire
Issued 9 May 2007 Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 14 May 2007
Resolution: onboard
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 May 2007 Resolved
Repair/replace starboard SSDG [name withheld].
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 14 May 2007
Resolution: onboard
Electrical › Electric Generation Source (service) › Generator
Issued 9 May 2007 Resolved
Prove proper operation of STBD SSDG, make repairs to heat exchanger.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2007
Resolved 14 May 2007
Resolution: onboard
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 9 May 2007 Resolved
Prove proper operation of STBD MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2007
Resolved 14 May 2007
Resolution: onboard
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 May 2007 Resolved
Conduct MOB drill, Fire drill, and prove proper operation of Fire Pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2007
Resolved 14 May 2007
Resolution: onboard
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 7 March 2006 Resolved
Provide complete first aid kit onboard.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Deck/Cargo › Cargo Stowage › General
Issued 7 March 2006 Resolved
Properly mount all appliances in galley to include refrigerator, microwave, TV, etc.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Deck/Cargo › Cargo Stowage › General
Issued 7 March 2006 Resolved
Properly mount all equipment in engine room.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 March 2006 Resolved
Show proper operation of electrical switchboard meters.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 March 2006 Resolved
Replace all holed piping in engine room to include the firemain, bilge, head drain, to include all temporary rubber hose patches.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 March 2006 Resolved
Provide 15 child size and 151 adult PFD's with lights onboard and properly mark all life jacket stowage areas.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Fire Fighting › Fire Main › Condition
Issued 7 March 2006 Resolved
Show proper operation of fire and bilge pumps.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Electrical › Electric Generation Source (service) › Generator
Issued 7 March 2006 Resolved
Show proper operation of both generators.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 March 2006 Resolved
Prove proper operation of all Life Float Water marker lights.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Communications › Radio Communications › EPIRB
Issued 7 March 2006 Resolved
Show proof of EPIRB maintenance log.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Navigation › Piloting/Steering › Compass Deviation Table
Issued 7 March 2006 Resolved
Provide Compass deviation table.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 March 2006 Resolved
Provide all current Navigational Publications onboard.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 March 2006 Resolved
Conduct and provide crew training log.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 March 2006 Resolved
Demonstrate crew proficiency in required drills.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Electrical › Lighting (service) › Conductor
Issued 7 March 2006 Resolved
Renew flood light cable with proper cable IAW 46 CFR 183.340
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 March 2006 Resolved
Conduct full Drug Testing Audit and provide all documentation.
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 9 May 2007
Resolution: onboard
Electrical › Electric Generation Source (service) › Generator
Issued 7 March 2006 Resolved
Properly mount generator end.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Engineering › Fuel Oil Service System › Hose
Issued 7 March 2006 Resolved
Ensure generator fuel hose fittings meet 46 CFR 182.710
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 4 May 2006
Construction/Loadline › Hull › Stiffener
Issued 19 December 2005 Resolved
Crop and renew the #1 - 4 port underdeck longitutinal channel stiffeners ( 2 in. face x 1/4 in. flange) from the transom bulkhead to the first transverse 4" x 3" x 1/4" frame.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2005
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 December 2005 Resolved
Crop and renew transverse underdeck 4 in. x 3 in. x 1/4 in. angle x 52-1/4 in. from the centerline outboard to port located in the sewage tank space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2005
Resolution: RECINDED
Construction/Loadline › Hull › Sheerstrake
Issued 1 December 2005 Resolved
Crop and renew to original scantlings the transom plate in way of the centerline and bottom shell. The insert plate to be a minimum of 12 in. high; 24 in in. to port and 24 in. to stbd measured from the centerline. Upper port and stbd radius corner to be a minimum of 1-1/2 in.
Action required: 705 - Other - as specified
Resolved 19 December 2005
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 1 December 2005 Resolved
In the engine room, crop and renew the salt water service bottom riser to a minimum of schedule 80 pipe.
Action required: 705 - Other - as specified
Resolved 19 December 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 1 December 2005 Resolved
Crop and renew the MSD.
Due 15 January 2006
Resolved 14 December 2005
Resolution: MSD holding tank removed from vessel.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 1 December 2005 Resolved
Stbd side, main deck house, remove the LEXAN window; arrest corrosion and reinstall the window. Prior to installation of the window, conduct an electrical wire check of installed wiring behind the interior bulkhead and overhead panels.
Due 15 January 2006
Resolved 9 December 2005
Construction/Loadline › Hull › Hull Plating
Issued 1 December 2005 Resolved
Reinsert the Main Deck in way of the new MSD Tank and MSD processing unit, port side, as cut-out this date. Conduct a hose test of the weld in way of the insert plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2005
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 6 April 2004 Resolved
VESSEL IS RESTRICTED FROM CARRYING OVERNIGHT PASSENGERS PER MSO JACKSONVILLE CID LETTER 083-02. LEGACY COMPONENT DESC: Berth
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 4 May 2006
Stability › Incline Test › General
Issued 6 April 2004 Resolved
PASSENGER COUNT IS REDUCED TO 49 ON AN OCEANS ROUTE AND 74 ON A LIMITED COASTWISE ROUTE UNTIL A STABILITY TEST IS COMPLETED ACCOUNTING FOR THE FISH / ICE BOXES ON THE UPPER DECK.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 4 May 2006
Resolution: Boxes were removed fromvessel prior to the sale to new owner.
Lifesaving › Lifejacket/PFD (Type I)
Issued 31 January 2003 Resolved
The vessel has 126 adult PFD's that are found "serviceable" the number of persons carried is limited to 126 adults and 16 children. This requirement was cleared and re-issued. Captain stated that he does not intend to carrying full compliment for some time. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 6 April 2004
Lifesaving › Lifebuoys
Issued 17 December 2002 Resolved
Paint all (4) 25 person Life Floats International Orange. LEGACY COMPONENT DESC: Color
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 31 January 2003
Resolution: Re-painted all (4) Life Floats International Orange.
Electrical › Electric Generation Source (service)
Issued 17 December 2002 Resolved
Provide blanks for open breaker slots in 110 V breaker panel located in the wheelhouse. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 31 January 2003
Resolution: Corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 17 December 2002 Resolved
Remove oily pads in vessel' s engine room. LEGACY COMPONENT DESC: Oily waste in bilges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 31 January 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 December 2002 Resolved
The vessel has 126 adult PFDs that are found serviceable. The number of persons carried is limited to 126 adults and 16 children. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 31 January 2003
Resolution: Owner/Captain stated that he has not, and would not be carrying more than 126 adult passengers, and 16 children while operating in the FL Keys.
Operations/Management › Drug and Alcohol Testing
Issued 17 December 2002 Resolved
Provide proof of Marine Employer's drug testing contract with an approved consortium prior to operating with passengers. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2003
Resolved 18 December 2002
Resolution: Corrected. All current employee''s are enrolled with Dr. Garcia of IMESON PRIMARY and Family Care Center, 10385 N. Main St. PO BOX 26999, Jacksonville, FL 32226. [phone withheld].
Accommodation/Occupational Safety › Occupational Safety
Issued 17 December 2002 Resolved
Install mesh, netting or additional course rails between the top rail and the deck or bulwark so that no space is greater than 4 inches where passengers have access to the rail. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 31 January 2003
Resolution: Corrected.
Electrical › Lighting (service)
Issued 28 February 2002 Resolved
COMPLETE PERMANENT WIRING IN DECK FLOOD LIGHTS LEGACY COMPONENT DESC: Lighting Fixture
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 26 March 2002
Engineering › Bilge Water Management System
Issued 25 February 2002 Resolved
Replace forepeak shut-off valve and reach rod. LEGACY COMPONENT DESC: Valve
Due 25 February 2002
Resolved 25 February 2002
Personnel › Certificates/Documents/Licenses
Issued 25 February 2002 Resolved
PROVIDE ORIGINAL LICENSE ONBOARD.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Documentation › Certificates/Documents
Issued 25 February 2002 Resolved
POST COI LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Documentation › Certificates/Documents
Issued 25 February 2002 Resolved
POST STABILITY LETTER LEGACY COMPONENT DESC: Stability Letter
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Documentation › Safety/Response Plans/Programs
Issued 25 February 2002 Resolved
PROVIDE WASTE MANAGEMENT PLAN LEGACY COMPONENT DESC: Waste Management Plan
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Personnel › Certificates/Documents/Licenses
Issued 25 February 2002 Resolved
PROVIDE FIRST AID/CPR CARDS FOR 50% OF CREW. LEGACY COMPONENT DESC: Certificate, First Aid Course Completion
Due 14 March 2002
Resolved 26 March 2002
Documentation › Certificates/Documents
Issued 25 February 2002 Resolved
PROVIDE VOYAGE PLAN
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Communications › Radio Communications
Issued 25 February 2002 Resolved
POST EMERGENCY BROADCAST PLACARD. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 25 February 2002 Resolved
PROVIDE WINDOW WIPER FOR BRIDGE WINDOW
Due 14 March 2002
Resolved 28 February 2002
Stability › Watertight Integrity
Issued 25 February 2002 Resolved
REPLACE GASKETS ON HATCHES ON DECK
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Stability › Weathertight Integrity
Issued 25 February 2002 Resolved
REPAIR DECK DOORS TO CLOSE PROPERLY
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 25 February 2002 Resolved
VESSEL PROHIBITED FROM UTILIZING BERTHING SPACE DUE TO INADEQUATE OVERNIGHT ACCOMMODATION LEGACY COMPONENT DESC: Berth
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2002
Resolved 26 March 2002
Resolution: VESSEL ACCOMMODATIONS ARE AS BUILT. MEET MINIMUM REQUIREMENTS OF THE REGULATIONS.
Accommodation/Occupational Safety › Cooking Systems
Issued 25 February 2002 Resolved
COMPLETE REPAIRS TO GALLEY
Action required: 705 - Other - as specified
Due 14 March 2002
Resolved 26 March 2002
Resolution: NO INSTALLED GALLEY.
Lifesaving › Lifebuoys
Issued 25 February 2002 Resolved
PROVIDE DETACHABLE CLIPS FOR LIFE BUOY WATER LIGHT
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 25 February 2002
Lifesaving › Lifejacket/PFD (Type III)
Issued 25 February 2002 Resolved
LABEL LIFE JACKET COMPARTMENT WITH AMOUNT AND TYPE ON UPPER DECK LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 25 February 2002 Resolved
PROVIDE CG APPROVED OR EQUIVALENT FIRST AID KIT LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 25 February 2002 Resolved
MOUNT FIRE EXTINGUISHER IN MAIN CABIN
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 25 February 2002 Resolved
PROVIDE FIRE/SMOKE DETECTOR BERTHING SPACE LEGACY COMPONENT DESC: Smoking
Action required: 705 - Other - as specified
Due 14 March 2002
Resolved 26 March 2002
Resolution: U/L LISTED DUAL SMOKE ALARM INSTALLED.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 25 February 2002 Resolved
INSTALL HOSE TO EXHAUST SYSTEM FOR VAPOR LINE ON BOTH ENGINES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 25 February 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 25 February 2002 Resolved
INSTALL MACHINERY GUARDS BOTH PROPULSION ENGINE AND STARBOARD GENERATOR
Due 14 March 2002
Resolved 26 March 2002
Electrical › Electric Supply System (service)
Issued 25 February 2002 Resolved
LABEL SWITCHES AT BRIDGE OPERATING STATION.
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 25 February 2002 Resolved
PERMANENT WIRE IN HEATER STARBOARD SIDE AFT MAIN CABIN. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Improper Installation
Due 14 March 2002
Resolved 28 February 2002
Engineering › Bilge Water Management System
Issued 25 February 2002 Resolved
PUMP DRY AND CLEAN BILGES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Electrical › Electrical Distribution System (service)
Issued 25 February 2002 Resolved
PROPERTY TERMINATE ELECTRICAL WIRES UNDER BRIDGE CONSOLE, ENGINE ROOM AND THROUGHOUT THE VESSEL. INSTALL RECEPTACLE COVERS THROUGHOUT THE VESSEL. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 14 March 2002
Resolved 26 March 2002
Electrical › Electrical Distribution System (service)
Issued 25 February 2002 Resolved
COMPLETE WIRING IN LIGHTING SYSTEM IN BERTHING SPACE LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Resolved 26 March 2002
Electrical › Electrical Distribution System (service)
Issued 25 February 2002 Resolved
PROVIDE COVER FOR FUSE BOX ON BRIDGE LEGACY COMPONENT DESC: Fuse
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Potable Water System
Issued 25 February 2002 Resolved
DEMONSTRATE WATER TO SINKS AND TOILETS THROUGHOUT THE VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 25 February 2002 Resolved
PROVIDE LOCK FOR SEWAGE TANK OVERBOARD VALVE
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 25 February 2002 Resolved
INSTALL FOR COVER BILGE PUMP ELECTRICAL CONNECTIONS.
Condition: Improper Installation
Due 14 March 2002
Resolved 26 March 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 25 February 2002 Resolved
PROVIDE AND MOUNT WRENCH FOR EMERGENCY ESCAPE EXIT IN ENGINE ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Accommodation/Occupational Safety › Potable Water System
Issued 25 February 2002 Resolved
PROPERTY TERMINATE WATER PIPING PORT SIDE AFT ENGINE ROOM.
Due 14 March 2002
Resolved 28 February 2002
Navigation › Piloting/Steering
Issued 15 January 2002 Resolved
INSTALL U. L. APPROVED NAVIGATION LIGHTS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2002
Resolved 25 February 2002
Construction/Loadline › Penetrations
Issued 15 January 2002 Resolved
Replace gasket in forepeak watertight flush hatch and provide capture chain. LEGACY COMPONENT DESC: Gasket
Action required: 705 - Other - as specified
Due 8 February 2002
Resolved 28 February 2002
Fire Fighting › Fire Pumps
Issued 15 January 2002 Resolved
Provide drawings of new fire/bilge pump arrangements. LEGACY COMPONENT DESC: Arrangement
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2002
Resolved 15 January 2002
Resolution: RESOLVED AT PTCD
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 15 January 2002 Resolved
Provide drawings for new MDE and reduction gear installation.
Due 8 February 2002
Resolved 17 February 2002
Electrical › Lighting (service)
Issued 15 January 2002 Resolved
Renew all internal light fixtures with current U.L. approved marine type. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 8 February 2002
Resolved 28 February 2002
Electrical › Electrical Distribution System (service)
Issued 15 January 2002 Resolved
Remove all dead ended wires throughout vessel. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 8 February 2002
Resolved 28 February 2002
Pollution Prevention/Response › Prevention Equipment
Issued 15 January 2002 Resolved
Prove sewage holding tank is of adequate size for number of persons allowed and route of operation. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Design Flaw
Due 8 February 2002
Resolved 8 February 2002
Resolution: 58.6 GAL.
Electrical › Lighting (emergency)
Issued 15 January 2002 Resolved
DEMONSTRATE PROPER OPERATION OF THE EMERGENCY LIGHTING SYSTEM
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2002
Resolved 28 February 2002
Electrical › Lighting (service)
Issued 15 January 2002 Resolved
REPLACE LIGHTING GUARDS AND GLOBES THROUGHOUT THE VESSEL LEGACY COMPONENT DESC: Lighting Fixture
Due 14 March 2002
Resolved 28 February 2002
Lifesaving
Issued 18 April 2000 Resolved
REPAIR/REPLACE 2 INOPERABLE WATERLIGHTS ON L/F'S.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Lifesaving
Issued 18 April 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Lifesaving
Issued 18 April 2000 Resolved
REPLACE 7 INOPERABLE LIGHTS ON LIFEJACKETS.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Documentation
Issued 18 April 2000 Resolved
FCC SAFETY CERT. EXPIRED._x001C_
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Lifesaving
Issued 23 April 1999 Resolved
REPLACE RETROREFLECTIVE MATERIAL FOR ALL LIFE FLOATS
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 23 April 1999 Resolved
REPAIR REPLACE WATERLIGHT ON LIFE RING
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 23 April 1999 Resolved
LABEL ALL LIFE JACKETS (NEW NAME)
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 23 April 1999 Resolved
LABEL ALL LIFE RINGS (NEW NAME)
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 23 April 1999 Resolved
LABEL FIRE AXE (NEW NAME)
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 23 April 1999 Resolved
REPLACE DAMAGED FIRE HOSE
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 23 April 1999 Resolved
REPLACE MISSING FIRE NOZZLE
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Accommodation/Occupational Safety
Issued 23 April 1999 Resolved
REPLACE SINK BASES
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Accommodation/Occupational Safety
Issued 23 April 1999 Resolved
REPAIR HEAD PIPING
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 23 April 1999 Resolved
LABEL ALL LIFE FLOATS (NEW NAME)
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 22 March 1999 Resolved
REPAIR STUFFING TUBE UPPER BULKHEAD STARBOARD SIDE CREW BERTHING BLKHD - NEW CABLE WAS RUN W/O SECURING STUFFING TUBE - OUTSIDE OF RING/STUFFING MATERIAL
Condition: Unknown
Due 22 April 1999
Resolved 7 May 1999
Construction/Loadline
Issued 22 March 1999 Resolved
BILGE SYSTEM ALUMINUM PIPING AT BILGE MANIFOLD CORRODED THROUGH - REPLACE AS NEW
Condition: Unknown
Due 22 April 1999
Resolved 7 May 1999
Lifesaving
Issued 5 May 1998 Resolved
VESSEL TO PROVE PROPER OPERATION/TEST OF EPIRB.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Navigation
Issued 5 May 1998 Resolved
VESSEL TO PROVE PROPER OPERATION OF ANCHOR LIGHT.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Construction/Loadline
Issued 19 May 1997 Resolved
REMOVE PLASTIC THRU HULL FITTINGS (FROM RHULE PUMPS) AND CORRECT IN ACCORDANCE WITH 46 CFR 182.40(a)(3).
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Accommodation/Occupational Safety
Issued 19 May 1997 Resolved
PROVIDE CHAIN AND SIGN ON STAIRS TO UPPER DECK THAT READS " NO PASSENGERS ALLOWED ON UPPER DECK".
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Electrical
Issued 19 May 1997 Resolved
HARD WIRE SALT WATER/ SANITARY PUMP.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Accommodation/Occupational Safety
Issued 19 May 1997 Resolved
STENCIL BULKHEAD "EMERGENGY EXIT" WITH ARROW IN ENGINE ROOM.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Lifesaving
Issued 29 April 1993 Resolved
REMOVE OIL FROM ENGINE ROOM BILGE.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Electrical
Issued 29 April 1993 Resolved
UPON COMPLETION OF REPAIRS TO THE PORT SIDE EMERGENCY GENERATOR LOCATED IN WAY OF THE MACHINERY SPACE DEMONSTRATE SATISFACTORY OPERATION OF THE SAME.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Fire Fighting
Issued 29 April 1993 Resolved
REPLACE STBD SIDE 1-1/2" FIRE HOSE TO STBD FIRE STATION FOUND RUPTURED,_x001C_ WITH SERVICEABLE HOSE IN KIND.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Navigation
Issued 29 April 1993 Resolved
REPLACE FRACTURED PORT SIDE FWD WINSHIELD WITH CLEAR AND UNOBSTRUCTED_x001C_ WINDSHIELD PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Lifesaving
Issued 29 April 1993 Resolved
REPLACE POLYPROPLENE GRABLINES ATTACHED TO TWO AFT RING BOUYS PRIOR TO_x001C_ CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Electrical
Issued 26 March 1992 Resolved
PROVE OPERATION OF 8KW GENERATOR UNDER LOAD.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Navigation
Issued 20 March 1991 Resolved
VESSEL MUST HAVE CHARTS AND PUBLICATIONS PLACED ON BOARD FOR OPERATING AREAPRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Lifesaving
Issued 20 March 1991 Resolved
VESSEL MUST HAVE PFD LIGHTS PLACED ON 7 ADULT AND 2 CHILDREN LIFE JACKETS_x001C_ PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Electrical
Issued 31 March 1988 Resolved
DOUBLE CLAMP COOLING WATER HOSES FROM SEA VALVES TO SERVICE GENERATOR.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988
Fire Fighting
Issued 31 March 1988 Resolved
REPLACE FIRE HOSES.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988
Fire Fighting
Issued 16 April 1987 Resolved
REPLACE PORT SIDE 1 1/2" FIRE HOSE.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Electrical
Issued 26 March 1986 Resolved
REPLACE MISSING LIGHT COVER IN WOMEN'S TOILET.
Condition: Unknown
Due 26 March 1986
Resolved 26 March 1986
Electrical
Issued 26 March 1986 Resolved
REPLACE MISSING ELECTRICAL RECEPTICAL COVERS IN AFTER BERTHING COMPARTMENT AND IN GALLEY. VESSEL MAY NOT CARRY PASSENGERS FOR HIRE UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 26 March 1986
Resolved 26 March 1986
Accommodation/Occupational Safety
Issued 26 March 1986 Resolved
PROVIDE 24 INCH VERTICAL SPACING BETWEEN PASSENGER BUNKS IN AFTER BERTHING COMPARTMENT.
Condition: Unknown
Due 26 March 1986
Resolved 26 March 1986
Engineering
Issued 26 March 1986 Resolved
REPLACE MISSING FUEL TANK VENT SCREEN ON STARBOARD SIDE OF VESSEL. VESSEL MAY NOT CARRY PASSENGERS FOR HIRE UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 26 March 1986
Resolved 26 March 1986

Casualty record · 6

15 August 2010Routine · role: Involved in a Marine Casualty · activity 4030138
4 July 2011Routine · role: Involved in a Marine Casualty · activity 4072446
13 June 2012Routine · role: Involved in a Marine Casualty · activity 4343862
19 June 2012Routine · role: Involved in a Marine Casualty · activity 4350943
30 August 2012Routine · role: Involved in a Marine Casualty · activity 4431524
15 December 2013Routine · role: Involved in a Marine Casualty · activity 4779634
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.