HAPPY HOOKER

HAPPY HOOKER is a 1976 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1985, most recently in February 2025, along with 93 deficiencies and 5 operational controls.

Records from 1985 to 2025. Most recent: inspection, 18 February 2025.

Built
1976
Last inspected
18 February 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYJ7886
Flag
UNITED STATES
366945880
Maury page id
psix-48708

Inspections, by type

…with no type recorded7
Years with a record 36 calendar years (1985–2025)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)52.4 ft × 15.8 ft × 6.1 ft
Registered tonnagegross 41 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WESTPORT, WASHINGTON:PORTLAND, OREGON, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ4862MMSI 366945880 · active · compulsorily equipped · granted 9 July 2025, expires 9 July 2035
WYJ7886MMSI 366945880 · expired · compulsorily equipped · granted 24 April 2014, cancelled 3 August 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

18 February 2025 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8080514
11 April 2024 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7889823
16 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7689196
27 February 2023 Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7642545
21 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611935
28 June 2022 Simplified Stability Test · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7590616
14 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7476802
26 May 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7205656
14 April 2021 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7175215
13 April 2021 Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7174655
1 April 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7167302
27 May 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6961161
10 April 2019 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6660092
3 April 2019 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6655203
17 April 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6393153
11 April 2017 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6115324
9 March 2017 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6100574
7 March 2016 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5828497
18 January 2011 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3938187
9 April 2009 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3442919
2 April 2009 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3437171
12 May 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3199272
2 May 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2992767
18 April 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2901566
4 May 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639334
4 May 2005 Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2318500
27 April 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2344797
27 July 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2147280
14 July 2004 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2132890
23 April 2004 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2051190
30 April 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1783970
16 April 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1775028
17 June 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1632289
7 June 2002 Annual Inspection · Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1627773
5 March 2002 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1491239
25 April 2001 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373436
2 April 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1060251
11 April 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1433632
28 April 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1391003
14 April 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788478
20 February 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 212582
26 January 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 804770
21 April 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1426073
11 April 1997 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1466461
19 May 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 48982
10 April 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1083615
2 April 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1377686
27 April 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 864263
19 April 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1164620
8 April 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1167603
7 April 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166809
13 May 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 837030
23 April 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 831400
22 April 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1136267
20 April 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1151199
22 June 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 59752
18 May 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257253
1 May 1992 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1414060
11 July 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 643731
16 April 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1134721
16 April 1991 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1220610
31 May 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 922206
18 May 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931968
19 May 1989 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1346719
24 May 1988 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1195144
23 July 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328250
15 May 1987 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1336124
12 June 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 990502
14 June 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 985960
14 June 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 986034
16 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1288732

Deficiency record · 93

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 April 2024 Resolved
...the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Marine inspector observed dead end wiring within sewage void near MSD tank, and exposed junction box with dead end wiring starboard side forward engine room bulkhead. 46 CFR 176.25-50
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 11 September 2024
Resolution: Operator provided photograph of junction box with cover.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 April 2024 Resolved
These regulations prescribe the minimum standards, procedures, and means to be used to test for the use of dangerous drugs. During audit of Chemical Testing Program Compliance the vessel was unable to provide evidence of the following: -Copy of latest Management Information System (MIS) form, or Consortium letter stating report filed for employer. (46 CFR 16.500) -Employee Assistance Program (EAP) informational material (46 CFR 16.401) -Crewmembers properly trained before assuming safety sensitive position prior to starting safety-sensitive function or Supervisor(s) received 1 hour EAP training(46 CFR 16.401) -Substance Abuse Professional (SAP) name and contact information (46 CFR 16.401) (46 CFR 16.101(a))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 8 October 2024
Resolution: Operator provided documentation of SAP, EAP training/materials, and MIS submission via email
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The engine room does not have a sign notifying that the space is protected by carbon dioxide. 46 CFR 185.612(g)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 11 July 2023
Resolution: Received satisfatory documentation of installed signage.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 May 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant OCMI. The escape hatch is not marked on the deck side. 46 CFR 185.606
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 11 July 2023
Resolution: Received satisfactory documentation of escape hatch markings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2023 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical. There are numerous dead end wires throughout the vessel in the machinery space and sewage holding space. 46 CFR 183.01-5(a) "Old T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 1 August 2023
Resolution: Dead end wires have been removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2023 Resolved
Through hull fittings and shutoff valves must be metallic. In the case of nonmetallic hulls, materials that will afford an equal degree of safety and heat resistivity as that afforded by the hull may be approved. The through hull fittings for the sewage tank vent and the galley sink discharge are plastic. 46 CFR 182.720(d)(3)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 11 July 2023
Resolution: Received satisfactory documentation of new through hull fittings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 07 adult kapok life jackets and 01 child kapok life jacket are leaking air and no longer in serviceable condition. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 May 2023
Resolution: New lifejackets were brought onboard the vessel to replace the leaking ones.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Fire buckets are not marked. 46 CFR 181.610
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 May 2023
Resolution: Fire buckets were labelled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023 Resolved
No more than 19 liters (five gallons) of flammable liquids may be stowed in any machinery space. The flammable liquids must be in containers of 3.8 liters (one gallon) or less. There was an excess of oil being stored in the engine room. 46 CFR 147.45(c)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 16 May 2023
Resolution: Extra oil was removed from the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 16 May 2023 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. There is an accumulation of debris in the bilge in the machinery space. 46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 11 July 2023
Resolution: Received satisfactory documentation of cleaned bilges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2023 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. There is a longitudinal crack in the wood of the steering post on the starboard side of the bolt. 46 CFR 176.814
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 1 August 2023
Resolution: Operator has sealed the crack with an epoxy resin.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2023 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. The bilge line in the machinery space could not be verified of its operational status due to its location and cleanliness of the bilge. 46 CFR 182.25-5(a) "Old T"
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 1 August 2023
Resolution: Bilge has been cleaned out.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have installed detectors in required spaces by 27Dec2022. Vessel has been limited to a Limited Coastwise route until detector installation has been verified by a Marine Inspector. 46 CFR 181.405(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 December 2022
Resolved 16 May 2023
Resolution: Verified installation of fire detectors.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 14 June 2022 Resolved
The items contained in first-aid kit shall be as listed in Table 160.041-4(b)...Opthalmic ointment. Opthalmic ointment is expired and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 21 June 2022
Resolution: Received satisfactory photograph of eye wash from operator.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 June 2022 Resolved
A vessel on a...coastwise route must carry- (1) Six hand red flare distress signals; (2) Six hand orange smoke distress signals. Vessel missing six orange smoke distress signals.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: Operator brought required hand flares onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 June 2022 Resolved
Crew accommodations [must be] of sufficient size adequate construction, and with suitable equipment to provide for the protection and accommodation of the crew. Exposed staples in the overhead of the crew accommodation space must be removed. 46 CFR 177.25-1(a) OLD T.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: Operator removed exposed staples.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 April 2021 Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock and internal structural examination at least once every two years. Vessel has failed to schedule drydock and internal structural examination within two years of last drydock as listed on the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2021
Resolved 13 April 2021
Resolution: Vessel completed credit Dry dock and ISE on 4/13/2021.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 May 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Vessel did not have operable fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 May 2020
Resolution: Witnessed successful operation new emergency fuel shutoff valve.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 May 2020 Resolved
Each survival craft must be secured to vessel by a painter. Vessel's has deteriorated painter line. 46 CFR 180.20-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 27 May 2020
Resolution: Operator purchased new painter line and MI's verified attachment of painter to vessel and life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 May 2020 Resolved
Each life float must be fitted with a light. 01 lifefloat had inoperable light. 46 CFR 180.15-5(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 27 May 2020
Resolution: Operator purchased new light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2020 Resolved
At each initial and subsequent inspection for certification and reinspection the MI shall inspect all lifesaving equipment to determine its serviceability. 10 Kapok life jackets plastic covered pads were wasted. 46 CFR 176.25-20(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 27 May 2020
Resolution: Operator replaced life jacket with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2020 Resolved
A vessel operating on a coastwise route must carry six orange and six red hand flares. Missing 04 flares. 46 CFR 180.35-5
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 27 May 2020
Resolution: Operator purchase 04 red flares.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2020 Resolved
Pyrotechnic distress signals shall stowed in a portable watertight container. 46 CFR 180.35-10
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 27 May 2020
Resolution: Rectified on the spot. Operator bought and labeled new container that meets all requirements.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 May 2020 Resolved
As appropriate for the intended voyage, vessel must carry up-to-date U.S. Coast Pilot. Operator did not have access to coast pilot on board. 46 CFR 185.20-35
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 27 May 2020
Resolution: Operator provided downloaded Coast Pilot on phone with the ability to access it without internet or service.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 May 2020 Resolved
Each survival craft must be visually inspected to ensure it's readiness for use on a weekly basis. Operator had no log of survival craft maintenance.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 May 2020
Resolution: Operator provided form for recording survival craft maintenance in the future, and logged maintenance from annual inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 May 2020 Resolved
Items in a first aid kit shall contain 10 ammonia inhalants. Vessel's first aid kit had expired ammonia inhalants. 46 CFR 184.710 & 46 CFR 160.041-4(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 27 May 2020
Resolution: Operator provided new ammonia inhalants.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 May 2020 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 01 inch high indicating direction of operation. Fuel shutoff stations labeling too small and missing direction of operation. 46 CFR 185.30-25
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 27 May 2020
Resolution: Operator updated labeling to be 01 inch and includes direction of operation.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 May 2020 Resolved
Lifefloats must be marked with Type II retroreflective material. Reflective tape worn on life floats.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 May 2020
Resolution: Operator affixed new Type II retroreflective tape on life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 April 2019 Resolved
46CFR 180.25-1(a)(7) - Life floats and buoyant apparatus when stowed in tiers, the seperate units must be kept apart by spacers. Life floats stacked in a tier of 3 on the vessel with no spacers in between the seperate units. Add spacers per regulation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 30 April 2019
Resolution: Vessel operator submitted photos of life floats being stacked with appropriate spacers.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 April 2019 Resolved
On a vessel of 26 or more feet in length, a visual and audible alarm must be provided at the operating station to indidcate a high water level in the affected space. Engine room bilge high level alarm indicator light at the operating station indicated multiple spaces (ER & Aft space) being activated. Repair so high level alarm activation in each space only indicates the appropriate compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 6 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 10 April 2019 Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across the terminals. All battery boxes missing appropriate cover to protect the terminals. Install covers across all batteries.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 6 May 2019
Resolution: Vessel submitted photos of battery screen/cover installed in machinery space.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 10 April 2019 Resolved
46CFR 177.01-5 - The scantlings, material, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Vessel deck rails consisting of 02 cracked welds on stbd side. Vessel must repair or replace all areas of rails containing deterioration, cracking, and corrosion at next credit dry dock in 2021.
Action required: 705 - Other - as specified
Due 11 April 2021
Resolved 13 April 2021
Resolution: Operator repaired cracked railings by re-welding damaged areas. Verified overall strength and condition of reails at dry dock exam on 4/13.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 April 2018 Resolved
Vessel does not have emergency instructions onboard and posted. 46 CFR 185.510.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 26 April 2018
Resolution: Owner posted emergency instructions.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2018 Resolved
Vessel's masthead light is inoperable. 33 CFR 83.21 and 33 CFR 83.23.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 18 April 2018
Resolution: Vessel installed new masthead light.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 17 April 2018 Resolved
Vessel has wire and cable runs passing through the engine room bulkheads into both fore and aft compartments that are not vapor tight. 46 CFR 177.405(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 10 May 2018
Resolution: Holes in engine room bulkhead are vapor tight.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 April 2018 Resolved
Vessel does not have alcohol testing equipment onboard. 46 CFR 4.06
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 1 May 2018
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 11 April 2017 Resolved
Replace light on (1) child PFD
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: Corrected on the spot
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 April 2017 Resolved
Name of vessel on buoy
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: Corrected on the spot
Engineering › Steering Gear System › Chain
Issued 11 April 2017 Resolved
Replace corroded chain rudder stops
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 12 April 2017
Resolution: Corrected on the spot
Engineering › Steering Gear System › Rudder
Issued 9 March 2017 Resolved
The marine inspector may conduct a visual exam and require NDT of the propeller shafting whenever the condition is in question. Propeller contained heavey pitting, 2 separate 1 inch cracks within 6 inches of the hub, and a 3 inch portion of several cracks on a previous repair on the hub.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2017
Resolved 10 March 2017
Resolution: Operator met with Marine Inspector and provided previously reworked propeller for inspection. New propeller ready for installation.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 March 2016 Resolved
Make bulkhead penetrations watertight in Laz and E/R
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2016
Resolved 11 March 2016
Resolution: Owner made bulkhead penetrations in Laz and E/R watertight by installing wooden plates around penetrations and sealing with water resistant silicone.
Lifesaving › Lifebuoys › Serviceable
Issued 10 March 2016 Resolved
Replace ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2016
Resolved 11 March 2016
Resolution: Owner installed new 24" Orange life ring buoy with required labeling and Q spec.
Communications › Radio Communications › EPIRB
Issued 10 March 2016 Resolved
Submit proof of EPIRB regristration.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 11 March 2016
Resolution: Owner provided proof of EPIRB registration.
Engineering › Bilge Water Management System › Not Operational
Issued 7 March 2016 Resolved
Fixed Bilge pump must be operational and pump at 25 gallons per minute. Repair cracked lazarette bilge pipe.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2016
Resolved 11 March 2016
Resolution: Owner replaced fixed power bilge pump impeller and installed new pipe and strainer in the Laz. Bilge pump operated superbly, pumped water from the Laz without issue
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 24 January 2011 Resolved
Submit all required plans and details for review of the recent re-power from a CAT 3406E to a Cat C18 engine. Prior to operations with passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2011
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 April 2009 Resolved
Repair and prevent chafing of fuel hose in engine room.
Due 9 May 2009
Resolved 9 April 2009
Resolution: Repaired on the spot.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 12 May 2008 Resolved
Provide placard with emergency broadcast instructions as per 46 CFR 184.510.
Due 12 June 2008
Resolved 12 May 2008
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Paddle
Issued 2 May 2007 Resolved
Renew deteriorated paddle in aft lifefloat.
Due 2 June 2007
Resolved 2 May 2007
Lifesaving › Lifefloat › Paddle
Issued 4 May 2006 Resolved
Replace broken lifefloat paddle for upper lifefloat.
Due 4 May 2006
Resolved 4 May 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 4 May 2006 Resolved
Renew retro reflective tape on all upper lifefloat apparatus.
Due 4 May 2006
Resolved 4 May 2006
Navigation › Piloting/Steering › Notices to Navigation
Issued 4 May 2006 Resolved
Have on board a current copy of the following: Lightlist, Coast Pilot, Notice to Mariners.
Due 4 May 2006
Resolved 4 May 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 May 2006 Resolved
Provide a copy of Lifesaving equipment maintenance records, drills and training for crew.
Due 4 May 2006
Resolved 4 May 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 May 2005 Resolved
Replace cracked waterlight for vessel's 18 passenger lifefloat. Vessel is resricted to carrying 33 passengers till corrected.
Due 4 June 2005
Resolved 4 May 2005
Resolution: Owner provided proof of purchase of waterlight to replace cracked waterlight.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 4 May 2005 Resolved
Provide current or corrected navigation charts onboard.
Due 4 June 2005
Resolved 4 May 2005
Resolution: Owner provided proof of purchase of current updated applicable navigation charts.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 4 May 2005 Resolved
Renew non operational lights on 1 adult and 1 child PFD's.
Due 4 June 2005
Resolved 4 May 2005
Resolution: Replaced battery in light for 1 adult PFD and replaced light for 1 child PFD. COS 5/4/05
Electrical › Electrical Distribution System (service)
Issued 11 May 2004 Resolved
Screw outlet cover plate back on outlet in passenger cabin under first seat fwd port side. LEGACY COMPONENT DESC: Outlet Box
Due 11 May 2004
Resolved 11 May 2004
Resolution: Corrected on spot.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 May 2004 Resolved
Prove operation of one lifejacket light or renew. LEGACY COMPONENT DESC: Lights
Due 11 May 2004
Resolved 11 May 2004
Resolution: Corrected on spot.
Lifesaving › Buoyant Apparatus
Issued 11 May 2004 Resolved
Put spacers between stacked lifefloats. LEGACY COMPONENT DESC: Lifefloat Spacers
Due 11 May 2004
Resolved 11 May 2004
Resolution: Corrected on spot.
Engineering › Steering Gear System
Issued 11 May 2004 Resolved
Eliminate excessive leakage from port rudder packing. LEGACY COMPONENT DESC: Rudder Stock
Due 11 May 2004
Resolved 11 May 2004
Resolution: Corrected on spot.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 May 2004 Resolved
Provide plans to renew existing welding cable on main engine starting system with marine grade battery cable. LEGACY COMPONENT DESC: Cable
Due 25 June 2004
Resolved 26 July 2004
Documentation › Logs/Records
Issued 30 April 2003 Resolved
Provide recent Drug and Alcohol test results per 46 CFR 16. LEGACY COMPONENT DESC: Drug Test Records
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 May 2003
Resolution: Provided results.
Lifesaving › Buoyant Apparatus
Issued 30 April 2003 Resolved
Provide and install waterlight mounting brackets for all three life float water lights. LEGACY COMPONENT DESC: Water light mounting brackets
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 May 2003
Resolution: Provided brackets.
Lifesaving › Lifebuoys
Issued 7 June 2002 Resolved
Renew lifering waterlight LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 25 June 2002
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 June 2002 Resolved
Renew 1 Child PFD
Due 30 June 2002
Resolved 7 June 2002
Construction/Loadline › Structures
Issued 7 June 2002 Resolved
Make collision bulkhead watertight as required by 46 CFR 179.210 LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 25 June 2002
Communications
Issued 7 June 2002 Resolved
Update FCC license to include 406 EPIRB.
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 17 June 2002
Navigation › Piloting/Steering
Issued 7 June 2002 Resolved
Service compass, swing compass or renew compass. LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 25 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 June 2002 Resolved
Update first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 25 June 2002
Engineering › Fuel Oil Service System
Issued 7 June 2002 Resolved
Provide proof that the fuel oil filters meet the requirements of 46 CFR 182.455(b)(6). LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 25 June 2002
Construction/Loadline
Issued 2 April 1996 Resolved
Properly seal forward bulkhead under galley area port side.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 7 April 1994 Resolved
PROPERLY REMARK FORWARD CABIN OUTSIDE HATCH WITH "EMERGENCY EXIT-KEEP CLEAR".
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Electrical
Issued 7 April 1994 Resolved
PROPERLY SPLICE ELECTRICAL CONNECTIONS ON DIESEL STOVE SUPPLY PUMP.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Lifesaving
Issued 7 April 1994 Resolved
DEMONSTRATE PROPER OPERATION OF AFT LIFE FLOAT WATERLIGHT.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Lifesaving
Issued 7 April 1994 Resolved
PROPERLY MARK VESSEL'S NAME OF EPIRB.
Condition: Unknown
Due 14 April 1994
Resolved 14 April 1994
Fire Fighting
Issued 23 April 1993 Resolved
PROVIDE THE PROPER AMOUNT OF TYPE B-II PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 23 May 1993
Resolved 13 May 1993
Lifesaving
Issued 23 April 1993 Resolved
DEMONSTRATE A PROPER MAN OVERBOARD DRILL RECOVERY.
Condition: Unknown
Due 23 June 1993
Resolved 13 May 1993
Navigation
Issued 20 April 1993 Resolved
PROPERLY REPAIR RUDDER PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Lifesaving
Issued 1 May 1992 Resolved
PLACE NAME ON EPIRB.
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Documentation
Issued 1 May 1992 Resolved
HAVE ON BOARD RESULTS OF RANDOM DRUG TESTING.
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Construction/Loadline
Issued 1 May 1992 Resolved
ENSURE ALL FREEING PORTS OPERATE FREELY, PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Fire Fighting
Issued 1 May 1992 Resolved
ENSURE ALL FIRE EXTINGUISHERS HAVE BEEN PROPERLY SERVICED.
Condition: Unknown
Due 1 June 1992
Resolved 19 May 1992
Engineering
Issued 1 May 1992 Resolved
PROPERLY MARK FUEL VALVE SHUTOFFS FOR TANKS.
Condition: Unknown
Due 1 June 1992
Resolved 19 May 1992
Documentation
Issued 16 April 1991 Resolved
PROVIDE ONE MARPOL V PLACARD.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Lifesaving
Issued 16 April 1991 Resolved
STENCIL STOWAGE COMPARTMENT FOR CHILDRENS LIFE PRESERVERS TO READ (FIVE).
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Lifesaving
Issued 16 April 1991 Resolved
PROVIDE ONE RING BOUY, WITH LIGHT AND LINE ATTACHED, IN OPERATIONAL CONDITION.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Engineering
Issued 18 May 1990 Resolved
PLACE STRAINER ON BILGE SUCTION INLET IN LAZARRETTE.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Lifesaving
Issued 15 May 1987 Resolved
VESSEL HAS A BUOYANT APPARATUS RATED FOR EIGHTEEN (18) PERSONS TO BRING LIFE SAVING EQUIPMENT INTO COMPLIANCE WITH OCEAN OPERATIONS. BUOYANT APPARATUS CANNOT SUFFICE FOR LIFE FLOATS.
Condition: Unknown
Due 15 May 1987
Resolved 15 May 1987
Documentation
Issued 12 June 1986 Resolved
PROVIDE EXTENSION LETTER FOR FCC OPERATOR LICENCE.
Condition: Unknown
Due 12 June 1986
Resolved 12 June 1986
Accommodation/Occupational Safety
Issued 14 June 1985 Resolved
STENCIL EMERGENCY EXIT (FORWARD BERTH).
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Lifesaving
Issued 14 June 1985 Resolved
STENCIL VESSEL NAME AND CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Construction/Loadline
Issued 14 June 1985 Resolved
ATTACH SAFETY CHAIN TO LAZERETTE HATCH COVER.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Navigation
Issued 14 June 1985 Resolved
PROVE OPERATION OF EPIRB.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Lifesaving
Issued 14 June 1985 Resolved
OBTAIN WATERLIGHT FOR RING BUOY.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.