APOLLO

APOLLO is a 1976 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2017, most recently in August 2025, along with 12 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 8 August 2025.

Built
1976
Last inspected
8 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 August 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG5249
Flag
UNITED STATES
Maury page id
psix-48709

Documentation record

Registered dimensions (L × B × D)100.0 ft × 22.8 ft × 4.7 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHALMETTE, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 September 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

8 August 2025 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8205411
12 August 2024 Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7979607
27 June 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7946281
25 June 2023 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7722730
30 August 2022 Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7547009
8 June 2022 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7472169
22 July 2021 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7264356
13 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7174410
15 July 2020 Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7006967
15 July 2020 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7026729
4 June 2020 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6967762
30 July 2019 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6767551
25 June 2018 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6455119
26 February 2018 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6361844
1 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6331049
31 July 2017 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6226647
13 July 2017 Inclining Experiment
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6209241

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 June 2024 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. MI observed all extinguishers out of date by several months. Vessel is required to have all extinguishers inspected/service prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 July 2024
Resolution: MI attended vessel and obsereved the fire extinguishers to be inspected and tagged.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 June 2023 Resolved
(a) An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600); (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power. The vessel's installed smoke detection system is not interconnected in all spaces, specifically, the machinery space/engine room. Make corrections to the satisfaction of a CG Marine Inspector. CITE: 46 CFR 181.450(a)(1)-(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 26 July 2023
Resolution: System installed and inspected; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2023 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. MI observed fire pump pressure of 48 psi at the local pressure gauge. Affect repairs to the firemain system and /or fire pump in order to achieve the required 60 psi. CITE: 46 CFR 181.300 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 26 July 2023
Resolution: Tested the newly installed fire pump; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2023 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section.The vessel has three 10-B:C CO2 portable fire extinguishers (PFEs) in the machinery space, however is required to have one 40-B:C in the vicinity of the exit as per 46 CFR Table 181.500(b). CITE: 46 CFR 181.500(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 18 August 2023
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 June 2023 Resolved
Rails shall consist of evenly spaced courses and the spacing between courses shall be not greater than 12". The chain rail across the aft deck is missing at least two chain courses, which must be installed. CITE: 46 CFR 177.35-1(a) Old-T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 26 July 2023
Resolution: Chain courses installed; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 8 June 2022 Resolved
On board bench grinder missing machinery guard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 June 2022
Resolved 8 June 2022
Resolution: Vessel crew removed bench grinder from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 June 2020 Resolved
In addition to meeting §180.130, each life float and buoyant apparatus must be stowed as required under this section, The float-free link required by §180.130(a)(1) must be: Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Vessel did not have tag on float-free link to determine if it was the proper size. Vessel must provide proof of the strength of the weak link to the satisfaction of the MI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 22 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2020 Resolved
No. 10 or smaller conductors may be connected by means of clamps screw with terminal plates having up turned lugs. Vessel had connections on main engine and generators that did not have up turned lugs. Vessel is required to replace all connectors that do not meet the standard to the satisfaction of the MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 22 July 2021
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 30 July 2019 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces. Vessel did not have an operable public address system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 6 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2019 Resolved
All electrical installations shall be to the satisfaction of the OCMI. 02 dead end wires were found in the port side void space aft of the frame 10 WT bulkhead, 01 dead end wire STBD side void space outboard of the crew quarters, and underneath the console on the bridge. All dead end wires need to be removed or properly terminated to the satisfaction of the attending Marine Inspectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 6 September 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 July 2019 Resolved
A penetration in a watertight bulkhead must be made watertight. A cable penetration on the port side of the #10 frame watertight bulkhead was open between either side of the bulkhead, and not WT. Penetration need to be made WT to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 6 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2019 Resolved
Replace all expired Alcohol test swab.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 6 September 2019