Records from 2016 to 2026. Most recent: inspection, 17 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 October 2025
No resolution recorded
Vessel's port quarter significantly damged from the rail to approximately 4 planks down, but above the waterline. Owner must submit repair proposal and effect repairs to the satisfaction of an attending USCG Marine Isnpector prior to operating as a Small Passenger Vessel.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 June 2025
Resolved
Investigate water intrusion in the forepeak, possibly coming from the starboard side stem but to investigate entire surrounding area and provide a repair proposal
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 13 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 June 2025
Resolved
Remove all dead-end wiring in tank space as discussed with vessel owner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 13 June 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 June 2025
Resolved
Provide repair proposal for port side aft bulkhead in tank space/forward bulkhead of engine room as discussed with vessel owner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 24 July 2025
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 June 2025
Resolved
Provide repair proposal for deck beam in tank space as discussed with vessel owner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 13 June 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2025
Resolved
Properly mount all bilge pumps, float switches and high-water alarms throughout vessel as discussed with vessel owner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 24 July 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 June 2025
Resolved
Update FCC Safety Radio Certificate, vessel is restricted to 1000’ from shore until certificate is updated
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 13 June 2025
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 21 May 2025
Resolved
Vessel shall conduct man overboard drill with a USCG Marine Inspector by July 26th, 2025
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 24 July 2025
Resolution: Conducted drills
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 21 May 2025
Resolved
Repair shore tie outlet in way of house on port side, aft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 24 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 May 2025
Resolved
Repair/replace oil supplied pressure gauge supply line at helm as discussed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 24 July 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 February 2025
Resolved
During the in-water portion of the drydock the O/O had installed a new firebuoy system but had not installed a manual pull cable. Issued requirement to install.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2025
Resolved 23 May 2025
Resolution: Installed and tested.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 26 September 2024
Resolved
Abandon ship drills were not logged nor conducted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: Done.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2024
Resolved
Missing 01 fire bucket
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: Added.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 September 2024
Resolved
Missing items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: Added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2024
Resolved
Waterlight line was corroded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 September 2024
Resolved
O/O had not enrolled crew member in a drug consortium
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: Enrolled.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 June 2024
Resolved
Due to the grounding or refloating an area above the prop that was repaired at some point with epoxy filler vice oakum fell out creating a large gap between the vertical board buts and keel. This created a flooding condition when the vessel was refloated requiring hauling and repair. Issued CG-835 to conduct repairs and sea trials.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2024
Resolved 3 July 2024
Resolution: O/O had repairs complete.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 4 October 2023
Resolved
Vessel was missing drug consortium letter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 4 October 2023
Resolution: Found at the end of the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 October 2023
Resolved
Vessel was missing or did not have updated pubs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 5 October 2023
Resolution: Purchased.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 4 October 2023
Resolved
Vessel had not logged any drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 4 October 2023
Resolution: Corrected during annual inspection while underway.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 October 2023
Resolved
Bilge high water alarms were operational, however the covers of the alarms kept falling off. Issued requirement to repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 28 November 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 October 2023
Resolved
E/R vents were stuck in the open position.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 5 October 2023
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 October 2023
Resolved
Emergency fuel shut-off placard was half missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 28 November 2023
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 October 2023
Resolved
Vessel's VHF radio had MMSI but the Lat/long was not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 28 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 October 2023
Resolved
Railings both port & starboard had a section of pipe to secure embarkation/debarkation. However, there is a stopper to prevent top part of railing from sliding out. This was missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 5 October 2023
Resolution: Fixed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 October 2023
Resolved
Deck hatches looked as though they are not usually dogged down by the presence of a large amount of fresh water inside. Ensure hatches are dogged down at all times when not in use.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2023
Resolved 5 October 2023
Resolution: Dogged.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 September 2022
Resolved
Prove proper operation of the high water alarm light at the operating station and label the location of each each.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 11 October 2022
Resolution: Received photographs of high level alarm light illuminating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2022
Resolved
Replace broken hose clamp on raw water pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 11 October 2022
Resolution: Received e-mail showing the hose clamp was replaced on the raw water pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2022
Resolved
Prior to carrying more than 32 passengers, replace 3 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 11 October 2022
Resolution: Received photograph of 3 new lifejackets.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 September 2022
Resolved
Provide plan to secure engine room ventilation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 11 October 2022
Resolution: Received plan to secure engine room ventilation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 October 2021
Resolved
Vessel's posted emergency procedures placard was mostly unreadable and covered in mold. What could be read was evidently for another vessel as it references the vessels emergency rescue boat, which this vessel does not have. Issued 01 discrepancy to address this and re-post.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 3 November 2021
Resolution: New copy posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 October 2021
Resolved
Issued 01 discrepancy for several unmarked PFDs and several that the markings had faded. Condemned 01 kapok PFD as it was no longer holding air.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 3 November 2021
Resolution: PFDs marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2021
Resolved
Issued 01 discrepancy for excessive leaking at the rudder post prior to the carriage of passengers. Rudder post was leaking at approx 1gpm.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2021
Resolved 6 October 2021
Resolution: Due to the O/O having a trip that evening, MIs came back the same afternoon to clear the leaking rudder post. O/O had hired local shipyard and re-stuffed rudder with three strands of packing. Verified underway that rudder post is now all sat and no longer
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 October 2021
Resolved
Issued 01 discrepancy to repair/replace lazarette and forepeak scuttle retention chain.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 3 November 2021
Resolution: Chain replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 October 2021
Resolved
Issued 01 discrepancy to provide a repair proposal for the vessel collision bulkhead. CB was detached on the port side and the top was atrophied and missing a section where it would normally have been attached to the deck above. Vessel must be repaired prior to 2022 sailing season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 24 May 2022
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 October 2021
Resolved
Issued 01 discrepancy to provide a repair proposal to address deck sagging on port and stbd side main deck amidships forward. Deck is wasting in several places and flexes when stepped on.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 13 April 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 October 2021
Resolved
Issued 01 discrepancy to provide a repair proposal to address leaking keel seams in the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 13 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 6 October 2021
Resolved
Issued 01 discrepancy to clean oily residue in bilge spaces. There was evidence of a soap product being used as there were bubbles in the spaces. O/O admitted to using dawn etc. Discussed with O/O that using a soap/degreaser in spaces is potentially an illegal operation and has huge fines, so he should not use soap.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2021
Resolved 6 October 2021
Resolution: Cleaned E/R bilges.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 January 2021
Resolved
Make fasteners available for inspection where planks and boards have been removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 22 January 2021
Resolution: Completed fastener inspection throughout the vessel where planks have been removed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 January 2021
Resolved
Install planks in accordance with plan submitted, caulk and fill seems where necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 4 May 2021
Resolution: Repairs completed IAW plans. Completed U/W sea trials completed. All SAT
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 January 2021
Resolved
Address the seem at the keel where water intrusion was identified via ice present at the keel on the port and starboard sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 4 May 2021
Resolution: Installed new sheer at the garboard plank and the keel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 July 2020
Resolved
Crop out and renew areas discussed where severe wood rot was identified. Includes both stern post 4x4" port and stbd side and 6 beams 1st, 2nd, and 3rd from the transome. Renew floor timbers and deck supports.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2020
Resolved 17 August 2020
Resolution: Areas cropped out and renewed as discussed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 July 2020
Resolved
With an attending marine inspector, haul the vessel and make rudder tube available for inspection. Discovered during the vessel's 5 year re-inspection underway was excessive water intrusion into the skin of the vessel, below the water line.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2020
Resolved 30 July 2020
Resolution: Vessel hauled, deck removed and rudders dropped. All areas made available for inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2020
Resolved
Repair and reduce water intrusion in way of the main engine shaft. During the underway inspection, witnessed excessive water intrusion at or around the vessel's shaft packing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2020
Resolved 21 August 2020
Resolution: Completed underway inspection and observed minimal water intrusion into the water tight envelope
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 July 2020
Resolved
Out of water, make available for inspection the vessel's starboard quarter where excessive caulking was identified. Remove bottom planks on the vessel's gunwhale on the transome above the main deck and make available for inspection where rot may be occurring identified by soft in the area.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2020
Resolved 30 July 2020
Resolution: Hauled out and made availabkle for inspection
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 July 2020
Resolved
Re configure or provide proper tool to access fuel shut-off valves.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2020
Resolved 21 August 2020
Resolution: Emergency fuel shut off valve access plate was provided with tool to acceess the fuel valves
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2020
Resolved
With attending marine inspector, conduct underway sea trials to determine sea worthiness of the vessel's rudder assembly.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2020
Resolved 21 August 2020
Resolution: Inspected rudder assembly for leaks. Satusfactory inspection complete underway.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 June 2019
Resolved
Provide external survey for electrical system from a certified marine electrician and update installation in accordance with 46CFR183
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 18 July 2019
Resolution: O/O updated electrical installation aboard vessel
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 June 2019
Resolved
Remove all debris and oil pads from bilges
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 26 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2019
Resolved
Properly install hardware to properly adjust linkage to red. gear.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 26 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 June 2019
Resolved
Conduct man overboard drill
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 26 June 2019