MAURY USCG vessel records Sign in
← All vessels

AMERICAN BEAUTY II

AMERICAN BEAUTY II is a 1976 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1985, most recently in April 2026, along with 159 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2024.

Records from 1985 to 2026. Most recent: inspection, 17 April 2026.

Built
1976
Last inspected
17 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB7944
Flag
UNITED STATES
366950240
Maury page id
psix-48710

Inspections, by type

…with no type recorded9
…past their stated due date1
Years with a record 37 calendar years (1985–2026)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.3 ft × 13.8 ft × 5.2 ft
Registered tonnagegross 19 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR W GREEN BOAT YARD · DELTAVILLE, VA, UNITED STATES · built 1976
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAG HARBOR, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB7944MMSI 366950240 · active · compulsorily equipped · granted 10 April 2024, expires 21 May 2034
WCZ8875MMSI not assigned · expired · voluntarily equipped · granted 19 June 2000, cancelled 21 August 2010 · licensed under a name not among this hull’s recorded names (not shown)
WSB9601MMSI not assigned · expired · compulsorily equipped · granted 19 June 1996, cancelled 21 October 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

17 April 2026 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8351286
7 October 2025 Damage Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8351331
21 May 2025 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8140716
27 February 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8085261
26 September 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8009171
22 June 2024 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7940161
22 June 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7944334
4 October 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7803533
18 January 2023 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7622531
23 September 2022 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7563394
26 January 2022 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7459622
6 October 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7326232
19 November 2020 Examination of Repairs · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7098608
8 July 2020 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6990563
2 June 2020 Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6970957
17 April 2020 Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6940367
4 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6672721
25 April 2019 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6655100
14 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6379906
31 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6161037
27 April 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6133493
13 May 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5879246
20 May 2014 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4863012
22 May 2012 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4318438
12 May 2009 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3472941
15 May 2008 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3206913
12 June 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2959052
15 June 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2679486
12 May 2006 Hull Examination · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2646723
24 May 2005 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2366153
26 May 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2077496
19 February 2004 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1994155
18 August 2003 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1879489
20 May 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2022173
5 March 2003 Periodic Inspection · Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1739606
10 July 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1650286
31 January 2002 Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1483137
29 January 2002 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1482317
11 September 2001 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1074013
7 June 2001 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1065722
3 August 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 131482
27 June 2000 COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1379269
24 February 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 150297
18 February 1998 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1113015
25 August 1997 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 785020
18 July 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 781281
18 July 1996 Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1088504
7 January 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 10144
26 June 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 877164
12 June 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1392283
29 May 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 834185
3 June 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1321632
26 May 1994 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 858984
4 June 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1151171
1 June 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 834934
14 April 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 954508
20 May 1991 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1228873
1 May 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 903195
17 April 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 922772
20 February 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 928437
17 April 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1041320
13 March 1989 Deficiency Check · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 891696
2 June 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036809
13 April 1988 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036976
3 August 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1028600
20 May 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005779
14 May 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1024212
24 April 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1024884
12 March 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1014471
1 August 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017492
2 April 1986 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306590
25 October 1985 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 994682
2 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1288213

Deficiency record · 159

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 October 2025 No resolution recorded
Vessel's port quarter significantly damged from the rail to approximately 4 planks down, but above the waterline. Owner must submit repair proposal and effect repairs to the satisfaction of an attending USCG Marine Isnpector prior to operating as a Small Passenger Vessel.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 June 2025 Resolved
Investigate water intrusion in the forepeak, possibly coming from the starboard side stem but to investigate entire surrounding area and provide a repair proposal
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 13 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 June 2025 Resolved
Remove all dead-end wiring in tank space as discussed with vessel owner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 13 June 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 June 2025 Resolved
Provide repair proposal for port side aft bulkhead in tank space/forward bulkhead of engine room as discussed with vessel owner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 24 July 2025
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 June 2025 Resolved
Provide repair proposal for deck beam in tank space as discussed with vessel owner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 13 June 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2025 Resolved
Properly mount all bilge pumps, float switches and high-water alarms throughout vessel as discussed with vessel owner
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 24 July 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 June 2025 Resolved
Update FCC Safety Radio Certificate, vessel is restricted to 1000’ from shore until certificate is updated
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 13 June 2025
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 21 May 2025 Resolved
Vessel shall conduct man overboard drill with a USCG Marine Inspector by July 26th, 2025
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 24 July 2025
Resolution: Conducted drills
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 21 May 2025 Resolved
Repair shore tie outlet in way of house on port side, aft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 24 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 May 2025 Resolved
Repair/replace oil supplied pressure gauge supply line at helm as discussed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2025
Resolved 24 July 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 February 2025 Resolved
During the in-water portion of the drydock the O/O had installed a new firebuoy system but had not installed a manual pull cable. Issued requirement to install.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2025
Resolved 23 May 2025
Resolution: Installed and tested.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 26 September 2024 Resolved
Abandon ship drills were not logged nor conducted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: Done.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2024 Resolved
Missing 01 fire bucket
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: Added.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 September 2024 Resolved
Missing items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: Added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2024 Resolved
Waterlight line was corroded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 September 2024 Resolved
O/O had not enrolled crew member in a drug consortium
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2024
Resolved 2 October 2024
Resolution: Enrolled.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 June 2024 Resolved
Due to the grounding or refloating an area above the prop that was repaired at some point with epoxy filler vice oakum fell out creating a large gap between the vertical board buts and keel. This created a flooding condition when the vessel was refloated requiring hauling and repair. Issued CG-835 to conduct repairs and sea trials.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2024
Resolved 3 July 2024
Resolution: O/O had repairs complete.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 4 October 2023 Resolved
Vessel was missing drug consortium letter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 4 October 2023
Resolution: Found at the end of the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 October 2023 Resolved
Vessel was missing or did not have updated pubs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 5 October 2023
Resolution: Purchased.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 4 October 2023 Resolved
Vessel had not logged any drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 4 October 2023
Resolution: Corrected during annual inspection while underway.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 October 2023 Resolved
Bilge high water alarms were operational, however the covers of the alarms kept falling off. Issued requirement to repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 28 November 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 October 2023 Resolved
E/R vents were stuck in the open position.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 5 October 2023
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 October 2023 Resolved
Emergency fuel shut-off placard was half missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 28 November 2023
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 October 2023 Resolved
Vessel's VHF radio had MMSI but the Lat/long was not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 28 November 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 October 2023 Resolved
Railings both port & starboard had a section of pipe to secure embarkation/debarkation. However, there is a stopper to prevent top part of railing from sliding out. This was missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2023
Resolved 5 October 2023
Resolution: Fixed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 October 2023 Resolved
Deck hatches looked as though they are not usually dogged down by the presence of a large amount of fresh water inside. Ensure hatches are dogged down at all times when not in use.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2023
Resolved 5 October 2023
Resolution: Dogged.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 September 2022 Resolved
Prove proper operation of the high water alarm light at the operating station and label the location of each each.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 11 October 2022
Resolution: Received photographs of high level alarm light illuminating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2022 Resolved
Replace broken hose clamp on raw water pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 11 October 2022
Resolution: Received e-mail showing the hose clamp was replaced on the raw water pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2022 Resolved
Prior to carrying more than 32 passengers, replace 3 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 11 October 2022
Resolution: Received photograph of 3 new lifejackets.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 September 2022 Resolved
Provide plan to secure engine room ventilation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 11 October 2022
Resolution: Received plan to secure engine room ventilation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 October 2021 Resolved
Vessel's posted emergency procedures placard was mostly unreadable and covered in mold. What could be read was evidently for another vessel as it references the vessels emergency rescue boat, which this vessel does not have. Issued 01 discrepancy to address this and re-post.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 3 November 2021
Resolution: New copy posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 October 2021 Resolved
Issued 01 discrepancy for several unmarked PFDs and several that the markings had faded. Condemned 01 kapok PFD as it was no longer holding air.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 3 November 2021
Resolution: PFDs marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2021 Resolved
Issued 01 discrepancy for excessive leaking at the rudder post prior to the carriage of passengers. Rudder post was leaking at approx 1gpm.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2021
Resolved 6 October 2021
Resolution: Due to the O/O having a trip that evening, MIs came back the same afternoon to clear the leaking rudder post. O/O had hired local shipyard and re-stuffed rudder with three strands of packing. Verified underway that rudder post is now all sat and no longer
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 October 2021 Resolved
Issued 01 discrepancy to repair/replace lazarette and forepeak scuttle retention chain.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 3 November 2021
Resolution: Chain replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 October 2021 Resolved
Issued 01 discrepancy to provide a repair proposal for the vessel collision bulkhead. CB was detached on the port side and the top was atrophied and missing a section where it would normally have been attached to the deck above. Vessel must be repaired prior to 2022 sailing season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 24 May 2022
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 October 2021 Resolved
Issued 01 discrepancy to provide a repair proposal to address deck sagging on port and stbd side main deck amidships forward. Deck is wasting in several places and flexes when stepped on.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 13 April 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 October 2021 Resolved
Issued 01 discrepancy to provide a repair proposal to address leaking keel seams in the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 13 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 6 October 2021 Resolved
Issued 01 discrepancy to clean oily residue in bilge spaces. There was evidence of a soap product being used as there were bubbles in the spaces. O/O admitted to using dawn etc. Discussed with O/O that using a soap/degreaser in spaces is potentially an illegal operation and has huge fines, so he should not use soap.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2021
Resolved 6 October 2021
Resolution: Cleaned E/R bilges.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 January 2021 Resolved
Make fasteners available for inspection where planks and boards have been removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 22 January 2021
Resolution: Completed fastener inspection throughout the vessel where planks have been removed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 January 2021 Resolved
Install planks in accordance with plan submitted, caulk and fill seems where necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 4 May 2021
Resolution: Repairs completed IAW plans. Completed U/W sea trials completed. All SAT
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 January 2021 Resolved
Address the seem at the keel where water intrusion was identified via ice present at the keel on the port and starboard sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 4 May 2021
Resolution: Installed new sheer at the garboard plank and the keel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 July 2020 Resolved
Crop out and renew areas discussed where severe wood rot was identified. Includes both stern post 4x4" port and stbd side and 6 beams 1st, 2nd, and 3rd from the transome. Renew floor timbers and deck supports.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2020
Resolved 17 August 2020
Resolution: Areas cropped out and renewed as discussed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 July 2020 Resolved
With an attending marine inspector, haul the vessel and make rudder tube available for inspection. Discovered during the vessel's 5 year re-inspection underway was excessive water intrusion into the skin of the vessel, below the water line.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2020
Resolved 30 July 2020
Resolution: Vessel hauled, deck removed and rudders dropped. All areas made available for inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2020 Resolved
Repair and reduce water intrusion in way of the main engine shaft. During the underway inspection, witnessed excessive water intrusion at or around the vessel's shaft packing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2020
Resolved 21 August 2020
Resolution: Completed underway inspection and observed minimal water intrusion into the water tight envelope
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 July 2020 Resolved
Out of water, make available for inspection the vessel's starboard quarter where excessive caulking was identified. Remove bottom planks on the vessel's gunwhale on the transome above the main deck and make available for inspection where rot may be occurring identified by soft in the area.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2020
Resolved 30 July 2020
Resolution: Hauled out and made availabkle for inspection
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 July 2020 Resolved
Re configure or provide proper tool to access fuel shut-off valves.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2020
Resolved 21 August 2020
Resolution: Emergency fuel shut off valve access plate was provided with tool to acceess the fuel valves
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2020 Resolved
With attending marine inspector, conduct underway sea trials to determine sea worthiness of the vessel's rudder assembly.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2020
Resolved 21 August 2020
Resolution: Inspected rudder assembly for leaks. Satusfactory inspection complete underway.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 June 2019 Resolved
Provide external survey for electrical system from a certified marine electrician and update installation in accordance with 46CFR183
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 18 July 2019
Resolution: O/O updated electrical installation aboard vessel
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 June 2019 Resolved
Remove all debris and oil pads from bilges
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 26 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2019 Resolved
Properly install hardware to properly adjust linkage to red. gear.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 26 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 June 2019 Resolved
Conduct man overboard drill
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 26 June 2019
Lifesaving › Lifefloat › Serviceable
Issued 22 May 2012 Resolved
Repair/Replace 12 passenger Life Float (approval# 160.27/87/0). Life float has frayed lines, broken straps (x4), wasted retro reflective tape and a large crack circling 1 corner. Vessel route is restricted to Lakes, Bays and Sound warm water only.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 25 May 2012
Resolution: Owner request to permanently restrict his route to LBS+cold water months only. This route and condition doesn''t require life floats.
Lifesaving › Hand Flares › Quantity
Issued 22 May 2012 Resolved
Provide proper quantity of approved flares. Vessel route is restricted to LBS.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 25 May 2012
Resolution: Owner ops to reduce route permanently to Lakes Bays and Sound during warm water months only. Vessel currently has the required flares for that route and condition.
Lifesaving › Lifefloat › Retroreflective Material
Issued 22 May 2012 Resolved
Replace retro reflective tape and all lines on Life float. Vessel route restricted to LBS.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2012
Resolved 25 May 2012
Resolution: Owner request to permanently restrict his route to LBS+cold water months only. This route and condition doesn''t require life floats.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2012 Resolved
Provide Eye wash for first aid kit.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 22 May 2012
Resolution: Received faxed copy of receipt for eye wash.
Engineering › Bilge Water Management System › Not Installed
Issued 22 May 2012 Resolved
Bilge High water alarm for engine room is INOP. Repair system to function properly.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 25 May 2012
Resolution: Replaced bilge float, test SAT.
Engineering › Bilge Water Management System › Not Operational
Issued 22 May 2012 Resolved
Repair Bilge High water alarm for Laz Space.
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 25 May 2012
Resolution: Replaced bilge float, test sat.
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2008 Resolved
Complete a satisfactory hull and ISE exam prior to carrying passengers for hire.
Condition: Placed in Improper Service
Due 15 May 2008
Resolved 19 May 2008
Resolution: Attended vessel in slings and conducted a hull and ISE exam for credit.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 15 May 2008 Resolved
Install new detachacable links for L/F.
Condition: Improper Installation
Due 15 May 2008
Resolved 19 May 2008
Resolution: Noted new links installed.
Lifesaving › Hand Flares › Expired
Issued 15 May 2008 Resolved
replace hand smoke signals
Condition: Improper/Lack of Maintenance
Due 15 May 2008
Resolved 19 May 2008
Resolution: Noted signals had been replaced
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 June 2007 Resolved
Reduce vessel total persons allowed by one person until the defective PFD is replaced.
Condition: Damaged By Earlier Event
Due 20 July 2007
Resolved 14 June 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 June 2007 Resolved
Replace circumferential line on R/B.
Condition: Unknown
Due 20 July 2007
Resolved 14 June 2007
Fire Fighting › Fire Bucket › Quantity
Issued 12 June 2007 Resolved
Provide one additional fire bucket...three required.
Condition: Placed in Improper Service
Due 20 July 2007
Resolved 14 June 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 June 2007 Resolved
Provide an operable waterlight for the stbd L/F.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2007
Resolved 14 June 2007
Lifesaving › Lifefloat › Paddle
Issued 12 June 2007 Resolved
Secure paddles to L/Fs.
Condition: Improper/Lack of Maintenance
Due 20 July 2007
Resolved 14 June 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2007 Resolved
Repair visual alarm for tank space high water alarm.
Condition: Improper/Lack of Maintenance
Due 20 July 2007
Resolved 14 June 2007
Communications › Radio Communications › EPIRB
Issued 15 June 2006 Resolved
Hyrdostatic Release needs to be replaced. Vessel is limited to 3 miles from shore until completed.
Due 14 July 2006
Resolved 1 August 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Hand Flares › Not on Board
Issued 24 May 2005 Resolved
Provide 5 orange smoke distress signals prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 May 2005 Resolved
Conduct man overboard and firefighting drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 May 2005 Resolved
Prove proper operation of bow light prior to night operations.
Action required: 705 - Other - as specified
Resolved 2 June 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Communications › Radio Communications › EPIRB
Issued 24 May 2005 Resolved
Provide new hydrostatic release for EPIRB, vessel restricted to no more than 3 miles from baseline until corrected.
Action required: 705 - Other - as specified
Resolved 28 June 2005
Resolution: By attending CG marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 May 2005 Resolved
Provide one adult lifejacket, vessel restricted to 38 passengers until corrected.
Action required: 705 - Other - as specified
Resolved 2 June 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 24 May 2005 Resolved
Provide safety radiotelephony certificate.
Due 7 June 2005
Resolved 28 June 2005
Resolution: By attending CG marine inspector.
Lifesaving › Lifefloat › Lifeline
Issued 24 May 2005 Resolved
Install new grabline for port lifefloat.
Due 7 June 2005
Resolved 2 June 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2005 Resolved
Eliminate wire nut connections under console.
Due 7 June 2005
Resolved 2 June 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2005 Resolved
Provide ammonia inhalants
Due 7 June 2005
Resolved 2 June 2005
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 May 2005 Resolved
Schedule appt. with CG for underway trials.
Due 27 June 2005
Resolved 28 June 2005
Resolution: By attending CG marine inspector.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 May 2004 Resolved
COD was not valid. NVC did not receive the rest of the lean owed on the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2004
Resolved 15 June 2004
Resolution: Showed up in MISLE as valid.
Documentation › Logs/Records
Issued 26 May 2004 Resolved
Provide proof of negaative results of crew's preliminary drug test. LEGACY COMPONENT DESC: Drug Test Records
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 May 2004 Resolved
Prove proper operation of all high level bilge alarms, ensure they are labeled correctly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Engineering › Generator (propulsion/auxiliary-electric)
Issued 26 May 2004 Resolved
Prove proper operation of generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Engineering › Steering Gear System
Issued 26 May 2004 Resolved
Prove proper operation of steering gear (very loose).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Documentation › Certificates/Documents › FCC SSL
Issued 26 May 2004 Resolved
Provide proof of valid Staion License (FCC).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2004
Documentation › Logs/Records › Logbook (official)
Issued 26 May 2004 Resolved
Aquire and keep logs of daily comms and garbage, monthly EPIRB and fire fighting logs, and quarterly drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2004
Resolution: Log was aquired and conducted quarterly drills with marine inspector present.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 26 May 2004 Resolved
Post emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 May 2004 Resolved
Provide 60 ft of dark synthetic, buoyant line for life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Resolution: Provided Yellow line, MI accepted it.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 May 2004 Resolved
Replace cracked window in pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Lifesaving › Buoyant Apparatus
Issued 26 May 2004 Resolved
Repair crack on bottom of starboard side LF, also remove "GULFSTREAM" and relabel name of vessel. Aslo, label the paddles with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 26 May 2004 Resolved
Ground both fuel fills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 May 2004 Resolved
Provide required items for first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 May 2004 Resolved
Mount MSD properly, not to be on a slant.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 26 May 2004 Resolved
Provide proof of proper operation of RPM meter for engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2004
Construction/Loadline › Structures
Issued 4 February 2003 Resolved
Replace starboard side slidding window, due to poor visabilty.
Due 1 June 2003
Resolved 20 May 2003
Resolution: Starboard side sliding window replaced with new.
Communications › Alarms/Indicators
Issued 4 February 2003 Resolved
Show proper operation of laz bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2003
Resolution: New anunciator installed.
Communications › Alarms/Indicators
Issued 4 February 2003 Resolved
Lable all bilge alarms as which compartment they service. LEGACY COMPONENT DESC: Bilge Alarm
Due 1 June 2003
Resolved 20 May 2003
Resolution: Bilge alarms labeled with appropriate compartments served.
Communications › Radio Communications › EPIRB
Issued 4 February 2003 Resolved
Renew expired battery for EPIRB, vessel is restricted to 3 nm from shore.
Due 1 June 2003
Resolved 2 May 2003
Resolution: New battery provided and installed on vessel.
Lifesaving
Issued 10 July 2002 Resolved
Replace expired hydrostatic release on EPRIB.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Installed new hydrostatic release on EPRIB.
Documentation
Issued 10 July 2002 Resolved
Replace all lines on 12 person life float and waterlight.
Due 10 August 2002
Resolved 19 August 2002
Resolution: Installed new lights and new water light.
Documentation
Issued 10 July 2002 Resolved
Post COI.
Due 10 August 2002
Resolved 30 July 2002
Resolution: Posted COI.
Lifesaving
Issued 10 July 2002 Resolved
Replace 9 adult and 2 children straps on life jackets.
Due 10 August 2002
Resolved 30 July 2002
Resolution: Replaced straps on 9 adult and 2 children life jackets.
Accommodation/Occupational Safety
Issued 10 July 2002 Resolved
Replace all expired items in first aid kit.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Replaced all expired items in first aid kit.
Navigation
Issued 10 July 2002 Resolved
Update all charts.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Purchased new charts.
Construction/Loadline
Issued 10 July 2002 Resolved
Seal bulkhead penetration in forward most bulkhead.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Sealed bulkhead penetration.
Construction/Loadline
Issued 10 July 2002 Resolved
Make forward hatch watertight.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Installed new gasket on foprward hatch.
Engineering
Issued 10 July 2002 Resolved
Shaft packing leaking excessivly.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Tightened shat packing.
Engineering
Issued 10 July 2002 Resolved
Remove excessive oil in engine room and fuel tank space bilges.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Removed excessive oil in bilges.
Engineering
Issued 10 July 2002 Resolved
Unable to open emergeny fuel shut-off cap to access fuel shut-off. Mount wrench in cabin.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Mounted wrench in cabin.
Lifesaving
Issued 10 July 2002 Resolved
Conduct underway drills.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Proceed underway and conducted drills. All sat.
Fire Fighting
Issued 10 July 2002 Resolved
Install lanyards on all 3 fire buckets.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Installed lanyards on all 3 fire buckets.
Navigation
Issued 10 July 2002 Resolved
Replace light on compass.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Installed new light bulb on compass.
Electrical
Issued 10 July 2002 Resolved
Provide 2 flashlights.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Provided 2 new flashlights.
Lifesaving
Issued 10 July 2002 Resolved
Provide proper operation of aft bilge alarm.
Due 10 August 2002
Resolved 19 July 2002
Resolution: Repair aft bilge alarm. All test sat.
Fire Fighting
Issued 10 July 2002 Resolved
Install "foot rest" underneath fireboy bottle in engine room.
Due 10 August 2002
Resolved 30 July 2002
Resolution: Installed "foot rest" underneath Fireboy bottle in engine room.
Lifesaving
Issued 10 July 2002 Resolved
Provide 2 sets of 4 foot oars for both life floats.
Due 10 August 2002
Resolved 30 July 2002
Resolution: Replaced both sets of paddles on both life floats.
Construction/Loadline
Issued 7 June 2001 Resolved
MAKE CABIN TOP/PILOT HOUSE WATER TIGHT ALL AROUND MAIN DECK. VESSEL RESTRICTED TO PROTECTED ROUTE UNTIL SUCH REPAIRS ARE COMPLETED.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
TIGHTEN OR MAKE REPAIRS TO MAIN DECK STBD SIDE OF FORWARD OF PILOT HOUSE.
Condition: Unknown
Due 7 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
MAKE AFT BULKHEAD IN ROD LOCKER COMPARTMENT WATER TIGHT.
Condition: Unknown
Due 7 June 2001
Resolved 8 June 2001
Lifesaving
Issued 7 June 2001 Resolved
REPAINT BUOYANT APPARATUS ORANGE.
Condition: Unknown
Due 7 June 2001
Resolved 8 June 2001
Lifesaving
Issued 18 July 1997 Resolved
Provide 406mhz EPIRB as per 46CFR180.15(i) and 46CFR180.64.
Condition: Unknown
Due 28 August 1997
Resolved 28 August 1997
Lifesaving
Issued 18 July 1996 Resolved
REPLACE MISSING EMERGENCY PROCEDURES PLACARD IN CABIN AREA.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 18 July 1996 Resolved
REPAIR INOP PA SYSTEM
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Fire Fighting
Issued 18 July 1996 Resolved
PROVIDE MARINE TYPE BRACKETS FOR ALL PORTABLE FIRE EXT.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Documentation
Issued 26 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW THE FCC RADIOTELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Documentation
Issued 26 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW THE CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Electrical
Issued 14 April 1992 Resolved
Provide cover plate for junction box located on forward engine room bulkhead. The requirement must be completed prior to carrying passengers. _x001C__x001C_ _x001C_
Condition: Unknown
Due 17 April 1992
Resolved 17 April 1992
Lifesaving
Issued 14 April 1992 Resolved
Prior to carrying passengers, provide 6 hand held red flares as required by46 CFR 180.35-5._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 April 1992
Resolved 17 April 1992
Construction/Loadline
Issued 20 May 1991 Resolved
PROVIDE VSL FOR U/W RIDE AS FOLLOWUP INSPECTION ON REPAIRS MADE TO STEM,_x001C_ RUDDER STUFFING BOX AND SHAFT STUFFING BOX TO INSURE WOOD IS SWELLING_x001C_ ADEQUATLY AND AREA IN WAY OF KEEL FROM ENGINE TO RUDDER.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Navigation
Issued 20 May 1991 Resolved
PROVIDE LIGHT FOR MAGNETIC COMPASS.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Lifesaving
Issued 20 May 1991 Resolved
INSTALL RING BOUY LIGHT PRIOR TO NIGHT TIME OPERATIONS.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Engineering
Issued 20 May 1991 Resolved
FIX LEAK IN AREA OF STUFFING BOX FOR SHAFT IN ENGINE ROOM.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Construction/Loadline
Issued 20 May 1991 Resolved
FIX LEAK IN WAY OF STEM NOTED DURING U/W RIDE OF VESSEL.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Navigation
Issued 20 May 1991 Resolved
FIX LEAK IN WAY OF RUDDER STUFFING BOX. LEAK NOTED DURING U/W RIDE OF VESSEL.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Construction/Loadline
Issued 20 May 1991 Resolved
PROVIDE VESSEL FOR UNDERWAY RIDE UPON COMPLETION OF DEFICIENCIES NO.1 THRU_x001C_NO. 6.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Construction/Loadline
Issued 17 April 1990 Resolved
REPAIR THE LEAK IN THE STUFFING BOX,PRESENTLY TAKING ON WATER,PRIOR TO CAR-RYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Fire Fighting
Issued 17 April 1990 Resolved
PROVIDE TWO BII TYPE PORTABLE FIRE EXTINGUISHERS FOR THE ENGINE SPACE WHEREPRESENTLY MALFUNCTIONING,PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Engineering
Issued 17 April 1990 Resolved
MARK OR STENCIL THE LOCATION OF THE ELECTRIC BILGE PUMP SWITCHES IN THE WHEEL HOUSE WHERE MISSING.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 17 April 1990 Resolved
REPLACE ALL DETERIORATED LINE ON THE TWO LIFE FLOATS WHICH CONNECT THE TWO WATER LIGHTS,PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Lifesaving
Issued 17 April 1990 Resolved
PROVIDE AND ATTACH A LINE WHICH WILL SECURE BOTH LIFE FLOATS TOGETHER WHICHARE ATTACHED TO ONE PAINTER,PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Documentation
Issued 17 April 1989 Resolved
PROVIDE A VALID MARINE OPERATORS LICENSE PRESENTLY NOT ONBOARD. ORIGINAL COMPLIANCE DATE IS: 19 MAY 89.
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Lifesaving
Issued 17 April 1989 Resolved
PROVIDE 2-4 FOOT PADDLES FOR LIFE FLOAT PRESENTLY MISSING. ORIGINAL COMPLIANCE IS: 19 MAY 89
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Engineering
Issued 17 April 1989 Resolved
PROVIDE A HEAT DEFLECTOR SHIELD FOR THE RECOR FUEL FILTER ON MAIN DIESEL ENGINES FUEL SYSTEM. ORIGINAL COMPLIANCE DATE IS: 19 MAY 89
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Lifesaving
Issued 17 April 1989 Resolved
PROVIDE (1) ADULT PFD, WHERE MISSING. ORIGINAL COMPLIANCE DATE IS: 19 MAY 89
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Engineering
Issued 17 April 1989 Resolved
PROVIDE PROOF THAT FLEXIBLE FUEL LINE IS CG APPROVED TYPE, OR REPLACE SAME WITH CG APPROVED. ORIGINAL COMPLIANCE DATE IS: 19 MAY 89
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Documentation
Issued 17 April 1989 Resolved
PROVIDE A VALID FCC SAFETY CERTIFICATE PRESENTLY NOT ONBOARD VESSEL RESTRICTED 1000 FEET FROM SHORE UNTIL CORRECTED. ORIGINAL COMPLIANCE DATE: 19 MAY 89.
Condition: Unknown
Due 17 April 1989
Resolved 17 April 1989
Engineering
Issued 13 March 1989 Resolved
MARK THE EMERGENCY FUEL SHUTOFFS WITH THE DIRECTION OF CLOSING.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Construction/Loadline
Issued 13 March 1989 Resolved
DOUBLE CLAMP THE SUCTION HOSE ON THE MSD RAW WATER SUCTION.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Electrical
Issued 13 March 1989 Resolved
CLEAN THE NEGATIVE BUSS BAR IN WAY OF THE BATTERY.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Electrical
Issued 13 March 1989 Resolved
PACK THE WIRE PENETRATION TO THE WATERTIGHT JUNCTION BOX ON THE FORWARD ENGINEROOM BULKHEAD.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Construction/Loadline
Issued 13 March 1989 Resolved
MAKE THE WIRE PENETRATION TO THE COLLISION BULKHEAD WATERTIGHT.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Construction/Loadline
Issued 13 March 1989 Resolved
REMOVE OR PERMANENTLY CAP THE OUT OF SERVICE SEA VALVE PREVIOUSLY USED FOR THE MSD.
Condition: Unknown
Due 13 March 1989
Resolved 13 March 1989
Engineering
Issued 2 June 1988 Resolved
REPLACE FLAME SCREEN ON PORT FUEL TANK VENT.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Lifesaving
Issued 24 April 1987 Resolved
PROPERLY EQUIP THE LIFEFLOAST IN REGARDS TO PADDLES, WEAKLIND AND WATER- LIGHTS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Lifesaving
Issued 24 April 1987 Resolved
LENGTHEN THE LIFEFLOAT DROP LINES TO 36" AS REQUIRED BY 46 CFR SUB CHAPTER Q IN REGARDS TO LIFEFLOAT CONSTRUCTION SPECIFICATIONS.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Documentation
Issued 24 April 1987 Resolved
OBTAIN THE MARINE DOCUMENT'S ANNUAL RENEWAL STICKER.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Construction/Loadline
Issued 24 April 1987 Resolved
REPLACE OR REPAIR THE HAIRLINE CRACKED FORWARD HATCH COVER.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Electrical
Issued 24 April 1987 Resolved
REPACK THE WINCH JUNCTION BOX WIRE PENETRATION.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Unknown
Issued 24 April 1987 Resolved
REQUIREMENT D4 RECINDED IN REGARDS TO DISTRIBUTION BOX COVERS PLACED OVER OPENINGS IN THE PANEL.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Navigation
Issued 24 April 1987 Resolved
PROVIDE AN UP TO DATE RULES OF THE ROAD PUBLICATION.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Navigation
Issued 24 April 1987 Resolved
PROVIDE A CURRENT SET OF TIDE TABLES.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987

Casualty record · 1

22 June 2024Routine · role: Involved in a Marine Casualty · activity 7944334
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.