LIBERTY KING is a 1998 freight ship. The Coast Guard has recorded 18 inspections since 2016, most recently in October 2024, along with 8 deficiencies and 3 operational controls.
Records from 2016 to 2024. Most recent: operational control imposed, 29 October 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it21511 - Dead Weight, Metric Ton 37917 - Displacement, Metric Ton 55729 - Convention (Subpart B), Gross Ton 21868 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 18
29 October 2024Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8026180
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 September 2023Resolved
PSCO Observed 03 Generators missing protective caps, exposing inner junction box and wires.
Per SOLAS (1997 ed) II-I/Reg 40.1.3 Electrical installations shall be such that the safety of passengers, crew and ships from electrical hazards will be ensured.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 September 2023
Resolved 21 September 2023
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 24 November 2021Resolved
All ships of 300 gross tonnage and upwards shall be fitted with 9 GHz radar to assist in navigation and collision avoidance.
Vessel reported x-band radar was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 24 November 2021
Resolved 24 November 2021
Resolution: Received Furuno technician's report attesting to full functionality of both X and S band radars. Deficiency cleared.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 24 November 2021Resolved
All ships of 500 gross tonnage and upwards shall have a 3 GHz radar to assist in navigation and in collision avoidance.
Vessel reported s-band radar was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 24 November 2021
Resolved 24 November 2021
Resolution: Received Furuno technician's report attesting to full functionality of both X and S band radars. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 February 2020Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7,8,9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY WITHOUT THE SANTION OF THE ADMINISTRATION. PSCO OBSERVED UNAPPROVED ELECTRICAL INSTALLATIONS IN CREW LAUNDRY. POWER SUPPLY FOR ADDITIONAL TERMINAL WAS ADDED IN CONJUNCTION WITH EXISTING INSTALLATIONS. 74 SOLAS (14) I/11(B) 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2020
Resolution: Received Class report attesting to the rectification by removing the additional power supply.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 10 October 2018Resolved
07111 Protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scaling by steam. The outer surface shall be water-resistant. 01 firefighting outfit had protective coating that was flaking on multiple areas. 74 SOLAS 01 II-2/17.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2018
Resolved 10 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2018Resolved
The machinery, boilers, other pressure vessles, associated piping and fittings shall be of a desgin and constructed adequate for the service for which they are intended. The drain piping on the purifiers that draines into the sludge tank is spraying excessive oil casuing a heavy accumulation of oil in the associated areas around the purifiers.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2018
Resolved 31 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 10 October 2018Resolved
General arrangement fire plans shall be permanently exhibited for the guidance of the ships officers, showing fire detection and fire extinguishing appliances. Vessel's fire plan does not refelct the correct amount of fire fighting suits.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2018
Resolved 31 October 2018
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 10 October 2018Resolved
All life saving appliances shall be in working order and ready for immediate use, during PSC examination, crew attempted to test outboard rescue boat engine without water. PSC team requested the engine be tested using water to ensure proper operation. The crew installed a drum and started the engine, no water was observed coming from the cooling port, which is an indication of impeller damage.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 October 2018
Resolved 10 October 2018
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.