STAR OF PALM BEACH

STAR OF PALM BEACH is a 1976 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1982, most recently in August 2014, along with 304 deficiencies and 1 casualty investigation in 2011.

Records from 1982 to 2014. Most recent: inspection, 8 August 2014.

Built
1976
Last inspected
8 August 2014
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ4328
Flag
UNITED STATES
367055930 (licence lapsed)
Maury page id
psix-48713

Inspections, by type

…with no type recorded12
Years with a record 32 calendar years (1982–2014)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)90.0 ft × 32.0 ft × 3.8 ft
Registered tonnagegross 96 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELCO MFG CO · WETUMPKA, AL, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSINGER ISLAND, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ4328MMSI 367055930 · expired · compulsorily equipped · granted 18 July 2009, cancelled 5 October 2019
WCW9565MMSI not assigned · expired · compulsorily equipped · granted 27 November 1996, cancelled 27 January 2007
WAH8442MMSI not assigned · expired · compulsorily equipped · granted 1 February 1995, cancelled 12 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

8 August 2014 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4948002
22 May 2012 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4318435
9 August 2011 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4113526
17 September 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3851245
3 February 2010 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3715524
14 December 2009 Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3649915
4 July 2009 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 3528040
17 September 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3326838
18 August 2008 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3302443
13 November 2007 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3097539
27 June 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2976268
22 May 2007 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2937578
6 April 2007 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2902885
15 August 2006 Annual Inspection · MARPOL Annex V Examination · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2750063
24 August 2005 Annual Inspection · MTSA Verification · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2473584
1 June 2005 MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2377985
25 January 2005 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2293637
25 August 2004 Damage Survey · Plan Review (Other than "T")
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2176669
24 August 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2176659
21 June 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2105499
15 May 2003 Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1793964
10 December 2002 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1723179
22 May 2002 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1619704
4 September 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1405266
21 August 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1072460
21 May 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1449475
6 August 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1068151
2 August 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1053521
11 July 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051320
11 July 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1391336
7 July 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 821275
8 June 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1413747
10 May 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1055126
3 December 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1046143
22 November 1999 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 810075
9 June 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1372656
26 May 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 799477
8 January 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 809398
8 January 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 809721
9 December 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 807500
30 November 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 807152
13 November 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 806225
12 November 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 804509
20 October 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 803025
9 October 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1440050
28 August 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1132116
15 July 1998 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 798031
24 July 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781740
26 November 1996 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1184980
30 September 1996 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1143421
25 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 38147
30 July 1996 COI Inspection · Drydock Extension · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089115
31 December 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 62626
3 August 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1186756
7 October 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1174707
11 August 1994 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 864560
4 August 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 870313
9 November 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1157915
5 October 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 847610
6 August 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1366881
17 September 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 953144
31 August 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1271027
5 August 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1244549
12 August 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938476
6 March 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931069
14 August 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 904082
8 January 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 901858
18 August 1989 COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 931166
4 February 1988 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1029492
7 December 1987 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1308855
5 February 1987 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1312144
10 December 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1332363
13 February 1986 Deficiency Check · COI Inspection · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 987394
11 February 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 978290
16 February 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971741
16 February 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271281
4 February 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966200
5 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272899

Deficiency record · 304

Engineering › Fuel Oil Service System › Ventilation
Issued 22 May 2012 Resolved
Replace flame screen on fuel vent with 30x30 mesh.
Due 5 June 2012
Resolved 5 June 2012
Resolution: Vessel placed flame screen on fuel vent with 30 X30 .
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 May 2012 Resolved
Replace retaining wires on centerline and starboard bow watertight hatches.
Due 5 June 2012
Resolved 5 June 2012
Resolution: Vessel replaced retaining wires on centerline starboard bow and watertight hatches.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 May 2012 Resolved
Replace cage on port side engine room light.
Due 12 June 2012
Resolved 12 June 2012
Resolution: Recieved email notification and picture verifying new cage was installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 May 2012 Resolved
Label emergency lighting.
Due 5 June 2012
Resolved 5 June 2012
Resolution: Vessel Labeled Emergency Lighting.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 May 2012 Resolved
Provide harness for man overboard workvest.
Due 5 June 2012
Resolved 5 June 2012
Resolution: Vessel provided harness for Man Overboard workvest.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 May 2012 Resolved
Provide emergency broadcast placard near radios at operating station.
Due 5 June 2012
Resolved 5 June 2012
Resolution: Vessel Provided emergency broadcast placard near radios at operating station.
Navigation › Piloting/Steering › Marine Charts
Issued 22 May 2012 Resolved
Provide charts for area of operation permitted by COI.
Due 12 June 2012
Resolved 12 June 2012
Resolution: Spoke with vessel representative charts were actually wrapped in older charts. Deficiency cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 August 2011 Resolved
Properly repair navigation anchor light and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2011
Resolution: Anchor light repaired and working properly.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 August 2011 Resolved
Prove proper operation of all emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2011
Resolution: Emergency lighting tested and operating properly.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 August 2011 Resolved
Provide proof of enrollment in DAPI program for vessel.
Action required: 705 - Other - as specified
Due 9 September 2011
Resolved 24 August 2011
Resolution: Proof of DAPI was onboard vessel.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 August 2011 Resolved
Place cap or cover on all junction boxes in overhead of main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2011
Resolved 24 August 2011
Resolution: All juntion boxes had covers installed.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 9 August 2011 Resolved
Ensure all coolers are accessible and available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2011
Resolution: Coolers open and available for inspection, inspected sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 August 2008 Resolved
Provide for radio operators permit for vessels Captain. Vessel is restarted to 1000 feet from shore.
Action required: 705 - Other - as specified
Resolved 19 August 2008
Construction/Loadline › Structures › Superstructure
Issued 18 August 2008 Resolved
Repair cracked window in pilot house (aft window bottom).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 17 September 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 August 2008 Resolved
Renew vessels drug consortium expires 31AUG08.
Action required: 705 - Other - as specified
Due 31 August 2008
Resolved 22 August 2008
Fire Fighting › Firemans Outfit › Axe
Issued 18 August 2008 Resolved
Replace vessel fire axe (has cracked fiberglass handle).
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 22 August 2008
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 18 August 2008 Resolved
Provide for vessels hailing port as required on vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 17 September 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 May 2007 Resolved
Permanently post fire control plan at operating station and on each deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: FCP posted.
Engineering › Fuel Oil Service System › Piping
Issued 22 May 2007 Resolved
Port MDE high psi injector line is worn thin. Replace injector line as discussed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Line replaced.
Engineering › Steering Gear System › Hydraulic Hose
Issued 22 May 2007 Resolved
Hydraulic steering hoses between the generators are rubbing together and have worn thin, replace both hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Hoses replaced.
Fire Fighting › Fire Hoses › Connections
Issued 22 May 2007 Resolved
Both fire station hose racks pinch off the hoses when the hoses are deployed. Rearrange the hose or racks to prevent kinking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Piping to rack reconfigured to direct hose down and not kink.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 22 May 2007 Resolved
Starboard shaft is wearing at the coupling IWO the forward bulkhead in the lazarette. Determine cause and make permanent repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Shaft re-aligned and greased.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 May 2007 Resolved
Properly enclose wiring connections located at starboard engine room entrance in enclosures.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 27 June 2007
Resolution: Connections enclosed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 May 2007 Resolved
Make permanent repair to holed/wasted longitudinal frame located at first frame inboard from starboard hull in lazarette, at next drydock.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 December 2007
Resolution: Verified wasted area of frame was replaced with like in kind steel.
Documentation › Certificates/Documents › Stability Letter
Issued 22 May 2007 Resolved
Post stability letter at operating station.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 24 May 2007
Resolution: Stability letter posted.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 May 2007 Resolved
Properly secure starboard navigation light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Light secured.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 22 May 2007 Resolved
Provide proper fuel vent screen on fuel vent line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Proper screen installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2007 Resolved
Properly run electric lines in wheelhouse (around bulkhead, not under carpet).
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 27 June 2007
Resolution: Wiring run adequately under metal protective strip.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 May 2007 Resolved
Conduct man overboard, fire, and security drills to the satisfaction of the attending USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Satisfactory drills conducted.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 May 2007 Resolved
Replaced 9 destroyed adult life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: 9 adult jackets replaced.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 May 2007 Resolved
Inspect, stencil, and provide new retro-reflective tape for all life jackets as needed.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 24 May 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 22 May 2007 Resolved
Submit plans for the two 208 receptacles on the upper deck. Plans must be approved prior to using the recetacles (portable heaters).
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 17 September 2008
Resolution: Receptacles and associated wiring has been removed an or blanked off.
Engineering › Steering Gear System › Hydraulic Hose
Issued 22 May 2007 Resolved
Repair leaking hydraulic fitting amidships at forward engine room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Resolution: Fitting tightened.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 May 2007 Resolved
Clean up all oil/fluids in engine room bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Resolution: Bilge satisfactorily cleaned.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 April 2007 Resolved
Apply draft marks to hull.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 18 August 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Enclose wire splice on sewage pump.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Wire splice placed in enclosure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Enclose wire splice from AC unit, starboard side.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Spliced placed in enclosure.
Engineering › Bilge Water Management System › Strainer
Issued 15 August 2006 Resolved
Install bilge strainer on bilge piping in aft compartment void (MSD tank space).
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Bilge strainer installed.
Stability › Watertight Integrity › General
Issued 15 August 2006 Resolved
Make bulkhead penetrations on forward bulkhead, port side, in second void, watertight.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Bulkhead penetrations made watertight.
Stability › Watertight Integrity › General
Issued 15 August 2006 Resolved
Remove water from bilge in second void.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Water removed from bilge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Enclose wiring on top of refrigerator in galley in an enclosure.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Wire splice placed in enclosure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Enclose wiring for battery charger behind generator in E/R in an enclosure.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Wire splice placed in enclosure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Enclose wire splice located outboard, starboard side engine room entrance, in an enclosure.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Wire splice placed in enclosure.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 August 2006 Resolved
Label circuit breakers in panel on bridge.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Circuit breakers labeled.
Documentation › Certificates/Documents › FCC SSL
Issued 15 August 2006 Resolved
Obtain FCC Safety Radio certificate. Vessel is restricted to operate within 1000 feet from shore.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: FCC Safety Radio certificate obtained.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 August 2006 Resolved
Replace expired medications in first aid kit.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Meds replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 August 2006 Resolved
Stencil vessel name on life ring buoy located on port bridge wing.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Life ring buoy stenciled properly.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 August 2006 Resolved
Replace cover for receptacle box, forward top deck, starboard side.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Cover replaced on box.
Engineering › Bilge Water Management System › Not Installed
Issued 15 August 2006 Resolved
Removed unused bilge equipment from shaft space.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: Unused equipment removed from space.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 August 2006 Resolved
Provide 46 adult life jackets for a total of 449.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Resolution: 449 adult life jackets provided.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 September 2005 Resolved
Properly install door knobs/ latching mechanisms on all stairwell/fire boundary doors.
Condition: Unknown
Due 15 September 2005
Resolved 15 September 2005
Resolution: Fire doors properly installed to specifications.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 August 2005 Resolved
Provide updated COD.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Provided Same.
Documentation › Certificates/Documents › FCC SSL
Issued 24 August 2005 Resolved
Provide updated FCC Safety Of Radio certificate.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Provided Same.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 August 2005 Resolved
Provide updated Drug and Alcohol Testing certification.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Provided Same.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 August 2005 Resolved
Update all navigation pubs, including CG Light List, Coast Pilot, Rules of the Road.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Updated Same.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 August 2005 Resolved
Clean out and update first aid kit.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Updated Same.
Lifesaving › Hand Flares › Expired
Issued 24 August 2005 Resolved
Replace expired signal flares.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 August 2005 Resolved
Label PFD storage on 02 deck (amount and separate child storage bins)
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Placarded Same.
Documentation › Certificates/Documents › Stability Letter
Issued 24 August 2005 Resolved
Post current Stability Letter (2001) and fax to Coast Guard.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Posted Same.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 24 August 2005 Resolved
Replace cracked window on 01 deck S/S fwd, outboard of doorway.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2005 Resolved
Mount hot water heater wiring into junction box in shaft compartment.
Condition: Unknown
Due 8 September 2005
Resolved 24 August 2005
Resolution: Wiring secured in box.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 August 2005 Resolved
Install conduit in overhead lighting above P/S generator in engine room.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Reinstalled Same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2005 Resolved
Remove L-bracket from wiring assembly in circuit breaker panels in engine room.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Removed Same.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 August 2005 Resolved
Install rubber matting on compartment door from engine room.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Installed Same.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 August 2005 Resolved
Install rubber matting on all steps leading to engine room.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Installed Same.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 August 2005 Resolved
Replace lighting fixture globes on service landing entrance ways.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2005 Resolved
Secure P/S MDE oil pressure/temperature sensor.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Secured Same.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 August 2005 Resolved
Service B-I fire extinguisher in pilothouse.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Serviced Same.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 August 2005 Resolved
Remove extension cord behind bar on 01 deck and install electrical outlet.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Removed Same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2005 Resolved
Install junction box for speaker and P.A. system wires under P/S forward stairwell on 02 deck.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Installed Same.
Engineering › Steering Gear System › Hydraulic Hose
Issued 24 August 2005 Resolved
Properly secure pressurized line for emergency steering hydraulic assembly (overhead P/S of br on 01 deck).
Condition: Unknown
Due 26 August 2005
Resolved 7 September 2005
Resolution: Properly Secured Same.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 August 2005 Resolved
Permanently mount overhead electrical outlet on P/S of bar on 02 deck.
Condition: Unknown
Due 8 September 2005
Resolved 7 September 2005
Resolution: Secured Same.
Engineering › Bilge Water Management System › Piping
Issued 25 January 2005 Resolved
Test bilge and fire piping for leaks.
Due 12 June 2005
Resolved 15 August 2006
Resolution: Bilge and fire piping satisfactory.
Engineering › Steering Gear System › Ram
Issued 25 August 2004 Resolved
Vessel is restricted from commercial operations until the cause of the loss of steering can be determined and repairs are made to the satisfaction of the attended Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 27 August 2004
Resolution: Vessel crew replaced broken hydralic ram.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2004 Resolved
Properly support all electrical wires in overhead.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Resolution: Vessel properly supported wires.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2004 Resolved
Properly dead end all wires in overhead and throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Resolution: Vessel crew properly removed improperly dead ended wires.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2004 Resolved
Remove illegal wire splices throughout vessel to include under bar area on main deck, cash register in bar area main deck, bar area 2nd deck, DC/AC converter in galley, etc...
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2004 Resolved
Properly attach cover plate on electrical box in galley. No duct tape!
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2004 Resolved
Light cover for the galley light is hanging off. Properly attach light cover.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 August 2004 Resolved
Place equipment panels on all equipment in galley. No duct tape!
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2004 Resolved
Remove all dead ended wire from around light control switch in galley.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 August 2004 Resolved
Install cover plate on electrical box under bar on main deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 25 August 2004 Resolved
Replace missing light bulbs in decrative lighting on main deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 August 2004 Resolved
Place electrical box cover on electrical box on second deck under stairs on port side forward.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2004 Resolved
Properly arrange wires (use proper wire connections and properly bundle) under control panel in bridge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 August 2004 Resolved
Remove all gear from in front of life jacket stowage on second deck behind bar area.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 25 August 2004 Resolved
Remove rotting food (box of lemons) from refrigerator in galley.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 August 2004 Resolved
Replace missing window pane on maindeck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Electrical › Electric Generation Source (service) › Power Requirement
Issued 25 August 2004 Resolved
Provide a complete electrical load analysis for the vessel to include all installed equipment. Also provide a complete electrical one-line diagram of the vessels electrical system.
Due 3 September 2004
Resolved 13 May 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 25 August 2004 Resolved
Remove all chairs that are weak and have questionable strength and replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 August 2004 Resolved
Install a locking device on oven doors in galley.
Condition: Improper/Lack of Maintenance
Due 3 September 2004
Resolved 27 August 2004
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 25 August 2004 Resolved
Repair damaged rudder angle indicator.
Condition: Improper/Lack of Maintenance
Due 3 September 2004
Resolved 15 August 2006
Resolution: Rudder angle indicator working properly.
Engineering › Steering Gear System › Follow-up Assembly
Issued 25 August 2004 Resolved
Provide proof that presently installed hydralic steering system and motor controls have been approved by Coast Guard.
Due 3 September 2004
Resolved 13 May 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 12 July 2004 Resolved
Make shaft compartment dry and ready for CG inspection.
Due 14 July 2004
Resolved 14 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2004 Resolved
Repair bilge suction wireing in shaft compartment.
Due 14 July 2004
Resolved 14 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2004 Resolved
Place cover on electrical box in shaft space.
Due 14 July 2004
Resolved 14 July 2004
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 June 2004 Resolved
Prove proper operation of bilge high-level alarms (visible & audible), vsl may not carry pax- no sail.
Due 21 June 2004
Resolved 21 June 2004
Resolution: Alarms visible & audible.
Documentation › Certificates/Documents › Stability Letter
Issued 21 June 2004 Resolved
Post stability letter.
Due 12 July 2004
Resolved 14 July 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 June 2004 Resolved
Install cover plate on junction box above sink at bar on upper deck.
Due 12 July 2004
Resolved 12 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 21 June 2004 Resolved
Post sign outside coat room for PFD storage.
Due 12 July 2004
Resolved 14 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 21 June 2004 Resolved
Post donning placard for all PFD types.
Due 12 July 2004
Resolved 14 July 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 June 2004 Resolved
Install cover plate on electric outlet IWO port staircase on upper deck near DJ.
Due 12 July 2004
Resolved 12 July 2004
Engineering › Fuel Oil Service System › Vent Pipe
Issued 21 June 2004 Resolved
Properly install fuel screen on stbd tank vent.
Due 12 July 2004
Resolved 14 July 2004
Construction/Loadline › Structures › Door
Issued 21 June 2004 Resolved
Replace glass in port door on lower deck.
Due 12 July 2004
Resolved 12 July 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 June 2004 Resolved
Install cover plate for electric outlet IWO fwd, stdb speaker on lower deck.
Due 12 July 2004
Resolved 14 July 2004
Electrical › Electric Generation Source (service) › Generator
Issued 21 June 2004 Resolved
Place dead face cover plate on distribution panel stbd side E/R entrance.
Due 12 July 2004
Resolved 12 July 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 21 June 2004 Resolved
Light above stbd E/R entrance.
Due 12 July 2004
Resolved 14 July 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 21 June 2004 Resolved
Replace broken light covers in E/R.
Due 12 July 2004
Resolved 14 July 2004
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 21 June 2004 Resolved
Replace broken engine mounts on both MDE's.
Due 28 June 2004
Resolved 14 July 2004
Fire Fighting › Fire Main › Condition
Issued 21 June 2004 Resolved
Replace leaking pipe in fire/bilge pump piping.
Due 12 July 2004
Resolved 21 June 2004
Resolution: Leaking repaired.
Engineering › Generator (propulsion-electric) › Charger
Issued 21 June 2004 Resolved
Replace air filters on both generators.
Due 12 July 2004
Resolved 12 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 21 June 2004 Resolved
Replace retro tape as needed on life jackets.
Due 12 July 2004
Resolved 12 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 21 June 2004 Resolved
Adjust straps on life jackets as needed.
Due 12 July 2004
Resolved 14 July 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 June 2004 Resolved
Post/have onboard original copy of COI.
Due 12 July 2004
Resolved 14 July 2004
Resolution: Activities New York will re-issue COI.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 June 2004 Resolved
Have onboard original DOC.
Due 12 July 2004
Resolved 14 July 2004
Resolution: Vessel as copy onboard. Vessel representative presented proof of submission for replacement.
Documentation › Certificates/Documents › Stability Letter
Issued 21 June 2004 Resolved
Post/have onboard original stability ltr.
Due 12 July 2004
Resolved 14 July 2004
Construction/Loadline › Penetrations › Pipe Flange
Issued 21 June 2004 Resolved
C/R cracked pipe in shaft compartment leading overboard.
Due 28 June 2004
Resolved 12 July 2004
Fire Fighting › Fire Pumps › Capacity
Issued 21 June 2004 Resolved
Properly install fire/bilge pump gauge.
Due 12 July 2004
Resolved 12 July 2004
Fire Fighting › Fire Main › Material
Issued 21 June 2004 Resolved
Remove rubber jubilees from portside fire main piping & make proper seamless, metal repair.
Due 12 July 2004
Resolved 12 July 2004
Fire Fighting › Fire Hydrants
Issued 15 May 2003 Resolved
Repair/replace fire station valve IWO of port engine room access. Valve does not close. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 31 May 2003
Resolved 23 June 2003
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 May 2003 Resolved
Missing four battery caps on batteries in e/r.
Condition: Improper/Lack of Maintenance
Due 15 May 2003
Resolved 15 May 2003
Personnel › Certificates/Documents/Licenses
Issued 15 May 2003 Resolved
Provide copy of Senior Dechhand Letter. LEGACY COMPONENT DESC: Senior Deckhand Letter
Due 22 May 2003
Resolved 23 June 2003
Communications › Radio Communications
Issued 15 May 2003 Resolved
Post Emergency Broadcast Placard LEGACY COMPONENT DESC: Emergency Broadcast Placard
Due 22 May 2003
Resolved 23 June 2003
Navigation › Piloting/Steering
Issued 15 May 2003 Resolved
Provide updated Magnetic compass deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Due 15 June 2003
Resolved 23 June 2003
Lifesaving › Embarkation Appliances/Stations
Issued 15 May 2003 Resolved
Replace broken Jacobs Ladder rung. LEGACY COMPONENT DESC: Jacob''s Ladder
Condition: Improper/Lack of Maintenance
Due 15 May 2003
Resolved 15 May 2003
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 May 2003 Resolved
Prove proper operation of emergency lighting.
Condition: Improper/Lack of Maintenance
Due 15 May 2003
Resolved 15 May 2003
Construction/Loadline › Structures
Issued 10 December 2002 Resolved
Repair excessive leakage from overhead of upper deck port and stbd. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 20 January 2003
Resolved 23 June 2003
Communications › Alarms/Indicators
Issued 22 May 2002 Resolved
Renew audible bilge level alarms on bridge. LEGACY COMPONENT DESC: Bilge Alarm
Due 5 June 2002
Resolved 6 June 2002
Resolution: Audible alarm works properly.
Documentation › Markings/Placards
Issued 22 May 2002 Resolved
Provide emergency broadcast placard.
Due 29 May 2002
Resolved 6 June 2002
Resolution: Permanently mounted emergency broadcast placard.
Navigation › Piloting/Steering
Issued 22 May 2002 Resolved
Provide updated copy of Coast Guard Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Due 29 May 2002
Resolved 6 June 2002
Resolution: Provided updated copy.
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 May 2002 Resolved
Provide First Aid Kit IAW 46 CFR 160.041. LEGACY COMPONENT DESC: Medicine Chest
Due 29 May 2002
Resolved 6 June 2002
Resolution: Mounted new first aid box.
Documentation › Markings/Placards
Issued 22 May 2002 Resolved
Affix lifejacket placard outside of VIP room.
Due 29 May 2002
Resolved 5 June 2002
Resolution: Affixed placard.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 May 2002 Resolved
Renew lagging on port main engine exhaust piping. LEGACY COMPONENT DESC: Piping (exhaust)
Due 29 May 2002
Resolved 6 June 2002
Resolution: Lagging properly renewed.
Engineering › Fuel Oil Storage/Transfer System
Issued 22 May 2002 Resolved
Renew flame screen on fuel tank vent pipe. LEGACY COMPONENT DESC: Vent Pipe
Due 29 May 2002
Resolved 6 June 2002
Resolution: Flame screen renewed.
Engineering › Shafting/Propeller Arrangements
Issued 22 May 2002 Resolved
Tighten port and stbd shaft packing. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Due 29 May 2002
Resolved 6 June 2002
Resolution: Renewed shaft packing.
Construction/Loadline › Structures
Issued 22 May 2002 Resolved
Replace door at operating station. LEGACY COMPONENT DESC: Door
Due 5 June 2002
Resolved 6 June 2002
Resolution: New door installed.
Electrical › Lighting (service)
Issued 22 May 2002 Resolved
Prove anchor light meets UL 1104. LEGACY COMPONENT DESC: Lighting Fixture
Due 31 December 2002
Resolved 23 June 2003
Electrical › Lighting (service)
Issued 22 May 2002 Resolved
Remove light forward of wheel house. LEGACY COMPONENT DESC: Lighting Fixture
Due 29 May 2002
Resolved 6 June 2002
Resolution: Removed light.
Electrical › Electrical Distribution System (service)
Issued 22 May 2002 Resolved
Perm mount J box in lazarette. LEGACY COMPONENT DESC: Junction Box
Due 29 May 2002
Resolved 6 June 2002
Resolution: Correctly mounted J box
Electrical › Lighting (service)
Issued 22 May 2002 Resolved
Replace light covers in galley (2). LEGACY COMPONENT DESC: Lighting Fixture
Due 5 June 2002
Resolved 6 June 2002
Resolution: Replaced 2 light covers.
Electrical › Electrical Distribution System (service)
Issued 22 May 2002 Resolved
Ensure all wires in engine room are secured with metal brackets spaced 24 inches apart. LEGACY COMPONENT DESC: Wiring
Due 22 June 2002
Resolved 5 July 2002
Resolution: Brackets were properly installed in E/R.
Electrical › Electrical Distribution System (service)
Issued 22 May 2002 Resolved
Replace wire to PA system on bridge. LEGACY COMPONENT DESC: Wiring
Due 5 June 2002
Resolved 6 June 2002
Resolution: Replaced with marine grade wire.
Electrical › Electrical Distribution System (service)
Issued 22 May 2002 Resolved
Renew dimmer switch cover and cover to J box in overhead over bar (second deck). LEGACY COMPONENT DESC: Junction Box
Due 29 May 2002
Resolved 6 June 2002
Resolution: Renewed cover and J box.
Electrical › Electrical Distribution System (service)
Issued 22 May 2002 Resolved
Properly wire heating unit in galley (warmer). LEGACY COMPONENT DESC: Wiring
Due 5 June 2002
Resolved 6 June 2002
Resolution: Warmer properly wired.
Electrical › Electrical Distribution System (emergency)
Issued 22 May 2002 Resolved
Properly wire vent located at aft blkhd of galley. LEGACY COMPONENT DESC: Wiring
Due 5 June 2002
Resolved 6 June 2002
Resolution: Vent properly wired.
Accommodation/Occupational Safety › Heating
Issued 22 May 2002 Resolved
Properly mount microwave and soda pump in galley.
Due 29 May 2002
Resolved 6 June 2002
Resolution: Microwave and soda pump properly mounted.
Accommodation/Occupational Safety
Issued 22 May 2002 Resolved
Renew cover to ice box in galley.
Due 22 June 2002
Resolved 5 July 2002
Resolution: Cover was replaced.
Construction/Loadline › Structures
Issued 22 May 2002 Resolved
Perm repair hole in deck above shaft compartment IWO stbd vent. LEGACY COMPONENT DESC: Deck Plating
Due 31 December 2002
Resolved 23 June 2003
Construction/Loadline › Structures
Issued 22 May 2002 Resolved
Make fwd bulkhead of wheel house weather tight. LEGACY COMPONENT DESC: Superstructure
Due 5 June 2002
Resolved 6 June 2002
Resolution: Patched small holes; made weather tight.
Construction/Loadline › Structures
Issued 22 May 2002 Resolved
Replace three broken windows in wheel house.
Due 5 June 2002
Resolved 6 June 2002
Resolution: Replaced 3 windows.
Operations/Management › Drills/Instruction
Issued 22 May 2002 Resolved
Due to Fleet Week, drills were unable to be completed. Complete man overboard drills for attending [name withheld]: Man Overboard Recovery
Due 22 June 2002
Resolved 6 June 2002
Resolution: Completed satisfactory drills on sister vessel, FIRST LADY.
Construction/Loadline › Structures
Issued 22 May 2002 Resolved
Make sills IWO port and stbd E/R access doors watertight.
Due 31 December 2002
Resolved 23 June 2003
Engineering
Issued 21 May 2001 Resolved
Install a shield on both MDE alternator belt drive.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Steps in front of generator control board requires dielectric mat.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Electrical
Issued 21 May 2001 Resolved
Remove deadend wiring in area around breaker panel on stbd side at entranceto engineroom.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Properly wire galley for video camera, Electrical junction box aft corner stbd side at entrance to galley(just to left of door).
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Properly cover wiring for hot water heater and attach strap to secure heater.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 21 May 2001 Resolved
Place a threaded cap on second deck under bar that goes to the hotwater heater space.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Properly secure batteries under console on bridge.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Fire Fighting
Issued 21 May 2001 Resolved
Properly stow Fire extinguishers in galley and engineroom.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Lifesaving
Issued 21 May 2001 Resolved
Mark both engineroom entrance/exits with "emergency exit do not block" and in the engineroom, post exit signs.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 21 May 2001 Resolved
Prove proper operation of bilge alarms.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Breaker panel stbd side forward at entrance to engineroom has breakout covers missing. Also Panel door will not close. Repair or replace.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 6 August 2000 Resolved
COMPLETE AS BUILT VERIFICATION FOR THE REPAIR MODIFICATIONS MADE TO THE VESSELS PADDLE STRUT IAW NYCMI EXAMINED PLANS AND NYCMI EXAMINATION LTR PR-010090. REPAIRS COMPLETED DURING DEC 2000 DRYDOCK.
Condition: Unknown
Due 6 August 2000
Resolved 6 August 2000
Electrical
Issued 2 August 2000 Resolved
COMPLETE AS BUILT VERIFICATION FOR THE NEW INSTALLATION OF P/S GENSETS IAW NYCMI APPROVED PLANS AND MAIN SWITCHBOARD IAW MSC APPROVED PLANS.
Condition: Unknown
Due 2 August 2000
Resolved 2 August 2000
Engineering
Issued 11 July 2000 Resolved
Provide USCG approved plans or provide plans for approval of new keel cooler installation, including materials, parts, piping details, and welding schedules.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Construction/Loadline
Issued 11 July 2000 Resolved
Drill stop, V & weld the crack in bottom transverse frame located where Perkins generator was previously installed in engine room.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Construction/Loadline
Issued 11 July 2000 Resolved
Provide plans for installation of 18" door sills, including materials and welding schedules to meet comment 4a of MSC H2-0001650 dtd June 9, 2000.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Construction/Loadline
Issued 11 July 2000 Resolved
Provide proof that foam to be used complies with MIL-P-21929B and has been tested in accordance with 46CFR170.245(a)(3).
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Accommodation/Occupational Safety
Issued 11 July 2000 Resolved
In the presence of the attending USCG Marine Inspector measure for the maximum number of passengers allowed IAW 46CFR115.113.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Construction/Loadline
Issued 11 July 2000 Resolved
Provide plans for approval for the installation of 560 cu.ft. of floatationfoam to meet comment 4b of MSC H2-0001650 dtd June 9, 2000. Foam must be installed in accordance with (IAW) 46CFR170.245.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Construction/Loadline
Issued 7 July 2000 Resolved
COMPLETE AS BUILT VERIFICATION FOR INSTALLATION OF FLOATATION FOAM IN COMPT#2, IAW NYCMI EXAMINED PLANS, MSC LTR H2-0001650/06JUN00, AND NYCMI LTR PR-010074.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Construction/Loadline
Issued 7 July 2000 Resolved
COMPLETE AS BUILT VERIFICATION FOR INSTALLATION OF A KEEL COOLER VALVE COFFERDAM, IAW NYCMI EXAMINED PLANS AND NYCMI LTR PR-010074.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Construction/Loadline
Issued 7 July 2000 Resolved
COMPLETE AS BUILT VERIFICATION FOR MODIFICATIONS MADE TO THE BOTTOM LONGS, IWO THE MDE MOUNTS, IAW NYCMI EXAMINED SECTION MODULUS CALCULATIONS PROVIDED BY BLANCKE MARINE SERVICES, AND NYCMI LTR OF EXAMINATION PR- 010074.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Engineering
Issued 8 June 2000 Resolved
REPLACE/ADJUST SHAFT PACKING ON PORT AND STBD SHAFTS.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Fire Fighting
Issued 8 June 2000 Resolved
PROPERLY INSTALL APPROVED A-60 RATED FIRE DOORS ON PORT AND STBD ENGINE ROOM ACCESSES.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Documentation
Issued 8 June 2000 Resolved
PROVIDE A COPY OF THE NEW STABILITY LETTER, FROM INCLINE EXPERIMENT DONE INMAY 2000, CONDUCTED ON PHIMS ZONE.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Engineering
Issued 8 June 2000 Resolved
INSTALL SUPPORT BRACKETS FOR FUEL LINES, SUPPLY AND RETURN, IN COMPT #3.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
PROVE PROPER OPERATION OF BILGE HIGH LEVEL LIGHTS ON BRIDGE.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Documentation
Issued 8 June 2000 Resolved
SUBMIT PLANS FOR ARROVAL TO [name withheld], FOR NEW INSTALLATIONS OF GENERATORS, PROPULSION ENGINES, POTABLE WATER TANKS, & SEWAGE TANK; OR PROVIDE PROOF THAT THE USCG HAS PREVIOUSLY APPROVED AND INSPECTED THE ABOVE LISTED NEW INSTALLATIONS.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Electrical
Issued 8 June 2000 Resolved
PROPERLY INSTALL EMERGENCY LIGHTING AND LIGHTED EXIT LIGHTS ON THE MAIN DECK.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Lifesaving
Issued 8 June 2000 Resolved
PROPERLY INSTALL A FIXED PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Navigation
Issued 8 June 2000 Resolved
REPLACE/REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
REPLACE GASKETS ON SCUTTLES TO COMPTS 1, 2, AND 3.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Engineering
Issued 8 June 2000 Resolved
PROPERLY INSTALL A 30X30 MESH FLAME SCREEN ON THE FUEL TANK VENT.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
C/R SSL'S #2 & 3 FROM TOP, STBD SIDE, IWO VERTICAL SIDE SHELL FRAME, IN COMPT 5. DUE AT NEXT DRYDOCK.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
PROPERLY MARK THE STERN OF THE VESSEL WITH THE VESSEL'S NAME AND HAILING PORT.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Engineering
Issued 8 June 2000 Resolved
PROVE PROPER OPERATION OF THE LOW LUBE OIL AND OVERSPEED TRIPS ON THE PORT AND STBD GENERATORS.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Electrical
Issued 8 June 2000 Resolved
INSTALL ELECTRICAL MATTING IN FRONT OF MAIN SWITCHBOARD.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Fire Fighting
Issued 8 June 2000 Resolved
PROVIDE PROOF OF FIRE LOAD RATINGS FOR CARPET, FURNISHINGS, AND OVERHEAD COVERING.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
C/R BL'S #2 & 5 FROM STBD SIDE, IN COMPT 5. DUE AT NEXT DRYDOCK.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
C/R SSL #3 FROM TOP, PORT SIDE, IWO VERTICAL SIDE SHELL FRAME, COMPT 5. DUEAT NEXT DRYDOCK.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
GAUGE HULL AT NEXT DRYDOCK AND PROVIDE PROOF OF ORIGINAL HULL PLATING THICKNESS.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
C/R PORT VERTICAL SIDE SHELL FRAME, COMPT 5. DUE AT NEXT DRYDOCK.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
C/R BL # 1 FROM PORT SIDE, A MINIMUM OF 30" FWD OF THE AFT BLKHD, COMPT 5. DUE AT NEXT DRYDOCK.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 9 June 1999 Resolved
Provide plans for USCG approval for high level bilge alarms required by 46 CFR 182.530
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Navigation
Issued 9 June 1999 Resolved
Secure 3/4" hydraulic piping IWO steering system pump.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Accommodation/Occupational Safety
Issued 9 June 1999 Resolved
Mark passenger capacity for upper deck at access's to upper deck. Letters and numbers must be a minimum of 1" and contrasting in color.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Accommodation/Occupational Safety
Issued 9 June 1999 Resolved
Replace broken window IWO main deck forward entrance stbd side.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Fire Fighting
Issued 9 June 1999 Resolved
Install gauge IWO fire pump discharge.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Lifesaving
Issued 9 June 1999 Resolved
Replace Type II retroflective tape.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Documentation
Issued 9 June 1999 Resolved
Provide plans for newly installed steering system.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Provide support for stern platform in accordance with initial plans.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Documentation
Issued 9 June 1999 Resolved
Provide plans and welders quals for new boarding area port side 01 deck. _x001C__x001C_ Plans approved 04Aug99 [name withheld], welder's quals remain outstanding.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Electrical
Issued 9 June 1999 Resolved
Replace light fixture in 01 deck bar office with UL marine approved fixtureand hard wire.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 9 June 1999 Resolved
Make permanent repairs to wiring penetrations thru deck IWO stbd entrance engine room.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Gauge pitting identified in lazarette and provide copy of report to USCG OCMI.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Provide proposal for repairs to deck areas where noted in galley and lazarette by 07JUL99. Make permanent repairs next drydock.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Accommodation/Occupational Safety
Issued 9 June 1999 Resolved
Secure hot water heater in engine room.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Documentation
Issued 9 June 1999 Resolved
Provide plans for newly installed engine control system.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Engineering
Issued 9 June 1999 Resolved
Provide reinforced marine hose IWO cooling suction line on Perkins generator.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 9 June 1999 Resolved
Install relay switch cover on air compressor.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Engineering
Issued 9 June 1999 Resolved
Install lagging IWO generator exhaust.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Install diagonal supports at frame 22 IAW original plans.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Electrical
Issued 9 June 1999 Resolved
Remove dead ended wires and controller located above snack bar.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Electrical
Issued 9 June 1999 Resolved
Rewire telephone bus and repair or remove phone in snack bar.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 9 June 1999 Resolved
Provide specs on wiring for 90 KW generator.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 9 June 1999 Resolved
Replace wire nuts with pressure wire fasteners or place connections inside junction box beneath bridge console.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Crop and renew angle longitudinal frame upper 6" port side and pick up skipwelds in void E.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Electrical
Issued 9 June 1999 Resolved
Repair and seal gauge box for perkins generator.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 9 June 1999 Resolved
Provide 110 volt outlet cover upper deck stbd side aft.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Electrical
Issued 9 June 1999 Resolved
Hard wire light fitures and provide metallic wire hangers at 24" center on the main deck passenger area.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Install machinery guards over all exposed rotating machinery i.e. bilge, fire, and steering pump couplings in engine room.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Provide proposal and repair hole in overhead forward stbd side in void E.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 9 June 1999 Resolved
Provide cover for generator tie in junction box in overhead of engine room
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Electrical
Issued 9 June 1999 Resolved
Secure battery switch in engine room.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Electrical
Issued 9 June 1999 Resolved
Install ventilated battery covers in engine room.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Provide proposal and temporary repairs by 07JUL99 to lower longitudinal frame mid compartment. Make permanent repairs next drydock.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 9 June 1999 Resolved
Provide proposal and repair holes in WTB stbd side overhead void E.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 9 June 1999 Resolved
Install light switch cover at stbd entrance to engine room.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 9 October 1998 Resolved
REPAIR ALL WASTED METAL IN FRAMING AROUND PORT AND STARBOARD QTR LADDERS LEADING TO SECOND DECK.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Construction/Loadline
Issued 9 October 1998 Resolved
REPAIR ALL WASTED BULKHEADS, STANCHIONS AND DOOR TO UPPER DECK BAR.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Construction/Loadline
Issued 9 October 1998 Resolved
REPAIR ALL WASTED METAL ALONG PORT AND STARBOARD BULKHEADS, ALL DECKS, AND ASSOCIATED WASTED PORTIONS OF STANCHIONS.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Construction/Loadline
Issued 9 October 1998 Resolved
REMOVED TEMPORARILY PATCHED AREAS OF SUPERSTRUCTURE AND REPAIR IAW NVIC 7- 68.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Construction/Loadline
Issued 9 October 1998 Resolved
REPAIR ALL WASTED ROOF SUPPORTS.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Accommodation/Occupational Safety
Issued 9 October 1998 Resolved
REPAIR WASTED RAILING STANCHIONS THROUGHOUT VSL.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Electrical
Issued 15 July 1998 Resolved
PROVIDE COVER FOR PILOT HOUSE FUSE BOX.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 15 July 1998 Resolved
REMOVE ALL EXTENSION CORDS.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 15 July 1998 Resolved
PROVIDE 4 STRIPS OF RETROREFLECTIVE TAPE ON ALL RING BUOYS.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Navigation
Issued 15 July 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 July 1998
Resolved 23 July 1998
Lifesaving
Issued 15 July 1998 Resolved
RENEW RETROREFLECTIVE TAPE ON 25 ADULT LIFEJACKETS.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 15 July 1998 Resolved
PROVIDE ELECTRICAL OUTLET COVERS IN GALLEY.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 15 July 1998 Resolved
RENEW FRAYED GALLEY HOT LAMP POWER CORD.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Construction/Loadline
Issued 15 July 1998 Resolved
RENEW PORT PADDLEWHEEL SUPPORT STRUT AND ASSOCIATED MEMBERS. ASSESS CONDITION OF STARBOARD STRUT.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 15 July 1998 Resolved
PROVIDE 6 ORANGE SMOKE FLARES.
Condition: Unknown
Due 15 July 1998
Resolved 23 July 1998
Documentation
Issued 15 July 1998 Resolved
PROVIDE COPY OF MASTER'S FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 15 July 1998 Resolved
PROVIDE AN ADDITIONAL 19 ADULT LIFEJACKETS. TOTAL PERSONS ALLOWED REDUCED TO 285 UNTIL REQUIREMENT MET.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Construction/Loadline
Issued 15 July 1998 Resolved
MAKE PERMANENT REPAIR TO TEMPORARILY REPAIRED HOLE IN DECK EDGE, STBD BOW. ITEM TO BE COMPLETED DURING AUGUST CREDIT DRYDOCK.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Navigation
Issued 15 July 1998 Resolved
REPAIR/PROVE OPERATION OF PILOT HOUSE RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 15 July 1998 Resolved
PROVIDE ELECTRICAL GRADE RUBBER MATTING IN FRONT OF MAIN SWITCHBOARD.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 15 July 1998 Resolved
REWIRE ALL SPLICED/FRAYED ANCILLIARY WIRING TO PORT & STBD MDEs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Accommodation/Occupational Safety
Issued 15 July 1998 Resolved
RENEW WASTED HANDRAILS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Accommodation/Occupational Safety
Issued 15 July 1998 Resolved
RENEW WORN/BROKEN END OF BOW BROW.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Navigation
Issued 15 July 1998 Resolved
PROVE OPERATION ECHO DEPTH SOUNDER.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Navigation
Issued 15 July 1998 Resolved
PROVE OPERATION OF RADAR UNIT.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 15 July 1998 Resolved
RENEW MISSING GALLEY LIGHT COVERS.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Construction/Loadline
Issued 11 August 1994 Resolved
CLEAN OUT INTAKE FOR SALT WATER SUCTION VALVE IN ENGINE ROOM.
Condition: Unknown
Due 7 October 1994
Resolved 2 September 1994
Construction/Loadline
Issued 11 August 1994 Resolved
REPLACE BILGE PIPE IN CENTER OF SHAFT ALLEY SPACE.
Condition: Unknown
Due 7 October 1994
Resolved 2 September 1994
Construction/Loadline
Issued 11 August 1994 Resolved
RENEW WASTED DECK IN WAY OF FEMALE TOILETS IN HEAD.
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Construction/Loadline
Issued 11 August 1994 Resolved
RENEW WASTED DECK PLATE IN WAY OF FWD STBD SIDE IN SHAFT ALLEY (18" X 18")
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Construction/Loadline
Issued 11 August 1994 Resolved
PROVIDE COPY OF GAGE READINGS FOR THE FWD AND AFT BULKHEADS OF SHAFT ALLEY.
Condition: Unknown
Due 7 October 1994
Resolved 2 September 1994
Construction/Loadline
Issued 11 August 1994 Resolved
REPAIR HOLE IN AFT BULKHEAD OF SHAFT ALLEY SPACE BETWEEN #1 AND #2 LONGITUDINALS (18" X 18")_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1994
Resolved 2 September 1994
Construction/Loadline
Issued 11 August 1994 Resolved
PROVIDE COPY OF HULL GUAGE READINGS WITHIN LAST YEAR.
Condition: Unknown
Due 7 October 1994
Resolved 2 September 1994
Construction/Loadline
Issued 11 August 1994 Resolved
CROP AND RENEW IN SHAFT ALLEY SPACE: STBD TOP LONG, PT TOP LONG AT SIDE SHELL, PORT MIDDLE LONG AT SIDE SHELL, DECK STIFFENER 2ND FM PORT, #1 LONG AS MARKED, #4 FWD LOWER HALF, #7 #9 #10 AS MARKED
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Engineering
Issued 4 August 1994 Resolved
repack port and starboard shaft packing glands.
Condition: Unknown
Due 4 September 1994
Resolved 12 August 1994
Electrical
Issued 4 August 1994 Resolved
provide guards for rotating machinery parts in main engine room.
Condition: Unknown
Due 4 September 1994
Resolved 12 August 1994
Electrical
Issued 4 August 1994 Resolved
provide cover for electrical outlet on aft port side of 01 deck.
Condition: Unknown
Due 4 September 1994
Resolved 12 August 1994
Electrical
Issued 4 August 1994 Resolved
provide battery box for back up running lights.
Condition: Unknown
Due 4 September 1994
Resolved 12 August 1994
Construction/Loadline
Issued 4 August 1994 Resolved
reattach the starboard hatch cover chain on bow
Condition: Unknown
Due 4 September 1994
Resolved 12 August 1994
Construction/Loadline
Issued 4 August 1994 Resolved
make bulkhead between engine room and shaft alley space watertight i way ofstarboard shaft.
Condition: Unknown
Due 4 September 1994
Resolved 12 August 1994
Electrical
Issued 4 August 1994 Resolved
provide proper electrical connections for wiring underneath bridge electricconsole.
Condition: Unknown
Due 4 September 1994
Resolved 12 August 1994
Electrical
Issued 6 August 1993 Resolved
REPAIR ELECTRICAL WIRE TO SEWAGE DISCHARGE PUMP AT BULKHEAD PENETRATION.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Electrical
Issued 6 August 1993 Resolved
REPAIR LIGHT FIXTURES IN SHAFT SPACE, GALLY AND OUTSIDE UPPER DECK SNACK BAR.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Electrical
Issued 6 August 1993 Resolved
PROVIDE SECOND SOURCE OF ELECTRICAL POWER FOR BILGE PUMPS AS REQUIRED BY 46CFR 182.25-10.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Construction/Loadline
Issued 6 August 1993 Resolved
PLUG HOLES IN LAST INTERNAL BULKHEAD WITH PIPE PLUGS.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Electrical
Issued 6 August 1993 Resolved
PROVIDE EACH VHF RADIO WITH ITS OWN FUSE AT THE DISTRIBUTION PANEL.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Fire Fighting
Issued 6 August 1993 Resolved
REPLACE TWO SUCIDE NOZZLES WITH FIRE FIGHTING NOZZLES APPROVED UNDER 162.027-6 AS REQUIRED BY 46 CFR 181.15-10._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Construction/Loadline
Issued 6 August 1993 Resolved
INSERT WASTED AREA OF MAIN DECK WHERE DRY EXHAUST STACKS PENETRATE.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Documentation
Issued 6 August 1993 Resolved
POST GARBAGE DISPOSAL PLACARD AND EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Lifesaving
Issued 6 August 1993 Resolved
PROVIDE 9 ADDITIONAL ACCEPTABLE ADULT LIFE JACKETS. VESSEL IS RESTRICTED TO296 TOTAL PERSONS ABOARD UNTIL COMPLIANCE. MUST BE COMPLIED WITH NOT LATER THAN 06OCT 93.
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Fire Fighting
Issued 6 August 1993 Resolved
PERMANENTLY MOUNT 1 BI AND 2 BII FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Construction/Loadline
Issued 31 August 1992 Resolved
COMPLETE THE OUTSTANDING WORKLIST ITEMS DTD 19AUG92 NO'S. 5-7,9-18.
Condition: Unknown
Due 31 August 1992
Resolved 31 August 1992
Engineering
Issued 31 August 1992 Resolved
REPAIR LEAK ON THE F/O FILL PIPING TO THE F/O TANK.
Condition: Unknown
Due 31 August 1992
Resolved 31 August 1992
Construction/Loadline
Issued 31 August 1992 Resolved
CONDUCT SEA TRIAL WITH A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 August 1992
Resolved 31 August 1992
Construction/Loadline
Issued 5 August 1992 Resolved
PROVIDE BELT GAUGE UNDER SECOND VOID TANK AT NEXT DRY DOCK.
Condition: Unknown
Due 5 August 1992
Resolved 5 August 1992
Fire Fighting
Issued 5 August 1992 Resolved
PROVIDE PROPOSAL AND TIME TABLE FOR BRINGING VSL INTO COMPLIANCE WITH 183.10-5(b). EITHER PROVIDE TWO GENERATORS OR TWO FIRE/BILGE PUMPS, ONE POWERED BY OTHER THAN HAND.
Condition: Unknown
Due 5 August 1992
Resolved 5 August 1992
Construction/Loadline
Issued 12 August 1991 Resolved
PROVIDE PROPOSAL AND TIME TABLE FOR BRINGING VESSEL INTO COMPLIANCE WITH 183.10-5(B),EITHER PROVIDE TWO GENERATORS OR TWO BILGE PUMPS (ONE POWERED BY OTHER THAN ELECTRICAL MEANS)._x001C_ _x001C_
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Lifesaving
Issued 12 August 1991 Resolved
COMMENCE SCHEDULE FOR REPLACEMENT OF LIFEJACKETS(WHITE STRAPS) AS AGREED (30 PER QUARTER) - 120 TO BE COMPLETED BY NEXT COI.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Accommodation/Occupational Safety
Issued 6 March 1991 Resolved
SUPPORT FRESH WATER LINE TO TOILETS FROM THE OVERHEAD IN LAZARETTE WITH METAL BRACKETS/HANGERS SPACED NOT LESS THAN 36" APART.
Condition: Unknown
Due 6 May 1991
Resolved 25 September 1991
Construction/Loadline
Issued 6 March 1991 Resolved
PROVIDE GAUGING REPORT FOR PITTED UNDERBODY AREAS AND OVERHEAD IN SHAFT COMPARTMENT AFT OF ENGINE ROOM AND REPAIR PLAN FOR AREAS OF EXCESSIVE WASTAGE.
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Construction/Loadline
Issued 6 March 1991 Resolved
DEWATER,PREPARE SURFACE AND RECOAT BOTTOM PLATING INSIDE VOID SPACE #2 IN WAY OF AFT BULKHEAD.
Condition: Unknown
Due 6 May 1991
Resolved 25 September 1991
Electrical
Issued 6 March 1991 Resolved
REPLACE 3-M TYPE CONNECTORS ON S/S GENERATOR WITH HARD CONNECTIONS AND REWIRE BILGE PUMPS AND MSD PUMP BACK TO THEIR RESPECTIVE JUNCTION BOXES USING GOOD MARINE AND ELECTRICAL PRACTICE.
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Lifesaving
Issued 8 January 1990 Resolved
SUPPLY A SUITABLE RESCUE BOAT FOR VESSEL.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Fire Fighting
Issued 8 January 1990 Resolved
MOVE MAIN DECK FIRE STATION TO ACCESSIBLE EXPOSED LOCATION OUTSIDE OF ENGINROOM VESTIBULE.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Navigation
Issued 8 January 1990 Resolved
MASTHEAD AND ANCHOR LIGHTS TO BE REPOSITIONED IN ACCORDANCE WITH COLREGS ANNEX I.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Electrical
Issued 8 January 1990 Resolved
REPLACE ALL NEWLY INSTALLED SINGLE POLE CIRCUIT BREAKERS WITH MULTI-POLE CIRCUIT BREAKERS IN ACCORDANCE WITH 46CFR183.10-35(B)(1).
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Electrical
Issued 4 February 1988 Resolved
REPAIR OR REPLACE THE WHEELHOUSE AMPMETER FOR THE PORT ENGINE.
Condition: Unknown
Due 4 February 1988
Resolved 4 February 1988
Fire Fighting
Issued 4 February 1988 Resolved
REPAIR THE LEAKING PACKING/SEAL TO THE BELT DRIVEN FIRE/BILGE PUMP DRIVEN BY PORT MAIN ENGINE.
Condition: Unknown
Due 4 February 1988
Resolved 4 February 1988
Lifesaving
Issued 5 February 1987 Resolved
PROVIDE 6 ADDITIONAL ADULT LIFE JACKETS.
Condition: Unknown
Due 5 February 1987
Resolved 5 February 1987
Documentation
Issued 5 February 1987 Resolved
PROVIDE FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 5 February 1987
Resolved 5 February 1987
Electrical
Issued 5 February 1987 Resolved
PROVIDE DATA NAME PLATE FOR THE GENERATOR WITH THE INFORMATION REQUIRED BY 46CFR183.10-5(A).
Condition: Unknown
Due 5 February 1987
Resolved 5 February 1987
Documentation
Issued 13 February 1986 Resolved
OBTAIN FCC RADIO OPERATORS PERMIT. PROVIDE NOTIFICATION TO [name withheld], AL WHEN TEST IS TO BE TAKEN AND WHEN PERMIT IS RECIEVED.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 16 February 1984 Resolved
BATTERY TERMINALS TO BE SOLDERED TYPE REF 46 CFR 183.05-20(C)
Condition: Unknown
Due 16 February 1984
Resolved 16 February 1984
Unknown
Issued 16 February 1984 Resolved
REPAIR COMODE IN LADIES RESTROOM
Condition: Unknown
Due 16 February 1984
Resolved 16 February 1984

Casualty record · 1

4 June 2011Routine · role: Transiting Vicinity of Primary Subject · activity 4036918
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.