MAURY USCG vessel records Sign in
← All vessels

BLUEWATER PRINCESS

BLUEWATER PRINCESS is a 1976 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1985, most recently in May 2008, along with 102 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2003.

Records from 1985 to 2008. Most recent: inspection, 27 May 2008.

Built
1976
Last inspected
27 May 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9932
Flag
UNITED STATES
367318250 (licence lapsed)
Maury page id
psix-48717

Inspections, by type

…with no type recorded4
…past their stated due date1
Years with a record 23 calendar years (1985–2008)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it30 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD9932MMSI 367318250 · expired · compulsorily equipped · granted 16 October 2007, cancelled 16 December 2017 · licensed under a name not among this hull’s recorded names (not shown)
WCX6973MMSI not assigned · expired · compulsorily equipped · granted 21 August 1997, cancelled 27 October 2007 · licensed under a name not among this hull’s recorded names (not shown)
WCR5433MMSI not assigned · cancelled · compulsorily equipped · granted 12 May 1995, cancelled 7 March 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 48

27 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3218567
9 May 2007 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2921211
16 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2638780
4 May 2005 Hull Examination · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2332186
14 March 2005 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2310030
8 March 2005 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2305781
23 May 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1799605
12 March 2003 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1727542
8 November 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1702839
14 June 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1691230
6 November 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075869
2 October 2001 Deficiency Check · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1441912
16 March 2001 Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1462944
14 August 2000 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1418765
10 August 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1465501
8 June 1999 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1432136
3 March 1999 Plan Review "T" Boat
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 798799
23 September 1998 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 800009
13 August 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1445375
15 October 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1110826
14 August 1997 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1421386
25 July 1997 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1404418
22 May 1997 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1364209
12 June 1996 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 878446
15 June 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 881940
15 May 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880591
20 June 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960456
20 June 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1087822
7 June 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323031
3 August 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846803
26 May 1993 Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132954
9 July 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950281
15 November 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246923
15 August 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936978
9 July 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937320
8 August 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902631
23 May 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236589
18 May 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1235862
20 June 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 889759
29 November 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206833
9 November 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891329
6 July 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902125
21 July 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022137
9 April 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330305
10 September 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1271985
6 August 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337251
1 October 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1297227
25 July 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1297226

Deficiency record · 102

Electrical › Electric Supply System (service) › Battery Installation
Issued 27 May 2008 Resolved
Place batteries in ventilated boxes with covers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2008
Resolved 27 May 2008
Resolution: Observed repairs to battery baoxes.
Fire Fighting › Fire Main › Material
Issued 27 May 2008 Resolved
Replace raw water wash down hose piping in engineroom.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2008
Resolved 27 May 2008
Resolution: Two sections of 1" piping for the raw water wash down hose were required to be rplaced located behined port main engine.
Lifesaving › Lifebuoys › Immediately Available
Issued 27 May 2008 Resolved
Provide a quick disconnect link from water light to ring life buoy.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2008
Resolved 27 May 2008
Resolution: Corrected.
Engineering › Lubricating Oil Service System › Hose
Issued 14 June 2007 Resolved
Fuel oil lines on both port and stbd MDEs have been spliced with improper fittings. Replace spliced fuel oil lines with approved type hoses with appropriate fittings.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 June 2007
Resolved 26 June 2007
Resolution: Fuel lines have been replaced with approved flexible hose.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 June 2007 Resolved
Vessel is missing 5 adult size type I PFDs. The vessel has 56 adult PFDs and the COI requires 61. The vessel is limited to carrying 54 passengers until deficiency has been corrected.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2007
Resolved 26 June 2007
Resolution: Vessel operator purchased 06 new Adult Type I PFDs fitted with lights.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 June 2007 Resolved
Vessel radar was damaged beyond repair and was removed. Owner has purchased a complete radar unit to be installed. Vessel is limited to less than 49 passengers on a limited coastwise route until new radar unit is installed and inspected by USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 June 2007
Resolved 26 June 2007
Resolution: Vessel operator has replaced entire radar unit with new.
Construction/Loadline › Hull › Keel
Issued 9 May 2007 Resolved
Vessel's wooden keel had marine borers in various areas. The keel is constructed of 2" thick boards fastened together, through bolted to the hull and a worm shoe with tar paper on the bottom. The first layer above the worm shoe in the forward section and the middle section far aft contained worms.
Action required: 705 - Other - as specified
Resolved 14 May 2007
Resolution: 5/10/07 The bottom section forward and mid section aft were removed and no further sign of marine borers was present. These sections were replaced and repainted with antifouling bottom paint. Worm shoe and barrier replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 16 May 2006 Resolved
Crew member recently hired has not participated in pre-employment drug screening. Master informed crew member is not permitted to serve in sensitive/critical position of responsibility until proof of pre-employment testing provided to CG Inspector.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Marine employer provided documentation proving crew member enrolled in drug testing consortium, pre-employment urinalysis to be conducted 06/07/2006
Engineering › Bilge Water Management System › Hose
Issued 16 May 2006 Resolved
Bilge suction hose line servicing forward lazarrete to be replaced.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Bilge suction hosed replaced
Engineering › Bilge Water Management System › Not Installed
Issued 16 May 2006 Resolved
Install high level bilge alarm in aft steering space/lazarrete
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: High level bilge alarm installed
Engineering › Bilge Water Management System › Not Installed
Issued 16 May 2006 Resolved
Install high level bilge alarm in battery space.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: High level bilge alarm installed
Engineering › Sea-water System (primary cooling) › Pump
Issued 16 May 2006 Resolved
Permanently mount raw water pump in engine space.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: Raw water pump installed properly
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 May 2006 Resolved
Tighten all hose clamps in engine space.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2006
Resolution: All hose clamps in engine room properly tightened
Engineering › Fuel Oil Service System › Filter
Issued 25 May 2005 Resolved
Install shields on RACOR fuel filters
Due 2 June 2005
Resolved 2 June 2005
Resolution: RACOR shields installed
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 May 2005 Resolved
No audible/visual alarms for Bilge System
Due 2 June 2005
Resolved 2 June 2005
Resolution: Bilge alarms installed
Engineering › Bilge Water Management System › Valve
Issued 25 May 2005 Resolved
Bilge System valves not labeled properly
Due 2 June 2005
Resolved 2 June 2005
Resolution: Bilge system valves properly labeled
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 May 2005 Resolved
Fixed Fire Fighting system servicing information not provided
Due 2 June 2005
Resolved 2 June 2005
Resolution: Fixed Fire Fighting system servicing information provided
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 25 May 2005 Resolved
Port Shaft Gland packing leaking
Due 2 June 2005
Resolved 2 June 2005
Resolution: Shaft gland packing replaced
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 May 2005 No resolution recorded
Ships name/port not marked on life buoy
Due 2 June 2005 — due date passed with no resolution recorded
Resolution: Lifebuoy properly marked
Lifesaving › Hand Flares › Expired
Issued 25 May 2005 Resolved
Expired flares stored with Serviceable flares
Due 2 June 2005
Resolved 2 June 2005
Resolution: Expired flares removed
Personnel › Training › First Aid/CPR
Issued 25 May 2005 Resolved
First Aid/CPR required for 50% of crew
Due 25 June 2005
Resolved 23 June 2005
Resolution: Provided proof of First Aid/CPR Training for crew
Documentation › Logs/Records › Logbook (official)
Issued 25 May 2005 Resolved
Daily Passanger Counts Required
Due 25 June 2005
Resolved 16 May 2006
Resolution: Passanger count logged as required
Documentation › Certificates/Documents › FCC SSL
Issued 25 May 2005 Resolved
Vessel required to obtain FCC SSL
Due 25 June 2005
Resolved 23 June 2005
Resolution: Provided copy of FCC SSL
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 March 2005 Resolved
46 176.500 CFR Failure to make vessel available for annual inspection within 3 month before or after each anniversary date of issuance of the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2005
Resolved 4 May 2005
Resolution: Inspection for COI conducted. Vessel found to be in substantial compliance and new COI issued
Engineering › Bilge Water Management System
Issued 12 March 2003 Resolved
REATTACH REACH ROD SERVING BILGE SUCTION IN CRASH COMPT. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 2 April 2003
Deck/Cargo › Mooring/Anchoring
Issued 12 March 2003 Resolved
RENEW OR SPLICE ANCHOR LINE WHERE CHAFFED. CLEARED. LEGACY COMPONENT DESC: Anchor Rope
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 12 March 2003
Construction/Loadline › Hull
Issued 12 March 2003 Resolved
ADD ADDITIONAL BOLTS THRU FRAMES 4 AND 5, PORT AND STBD SIDES OF CRASH COMPT AS SHOWN. TOTAL OF 10 BOLTS NEEDED. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Transverse Frame
Due 1 April 2003
Resolved 2 April 2003
Construction/Loadline › Hull
Issued 12 March 2003 Resolved
NUT ON CHINE BOLT IN #7 FRAME PORTSIDE OF #2 COMPT. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Transverse Frame
Due 1 April 2003
Resolved 2 April 2003
Engineering › Bilge Water Management System
Issued 12 March 2003 Resolved
RENEW STRAINERS SERVING BILG SUCTION IN #2 AND #3 COMPTS. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Strainer
Condition: Unknown
Due 1 April 2003
Resolved 2 April 2003
Engineering › Bilge Water Management System
Issued 12 March 2003 Resolved
REMOVE ALL WATER AND DEBRIS FROM ALL BILGES.
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 6 May 2003
Engineering › Bilge Water Management System
Issued 12 March 2003 Resolved
REMOVE BUCKETS FROM UNDER BILGE SUCTIONS IN #2 AND #3 COMPTS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 1 April 2003
Resolved 2 April 2003
Construction/Loadline › Structures
Issued 12 March 2003 Resolved
INSTALL COVERS OVER PASSAGE HOLES IN AFT BHD OF #3 COMPT. ALL SCREWS MUST BE INSTALLED. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: End Bulkhead
Due 1 April 2003
Resolved 6 May 2003
Construction/Loadline › Hull
Issued 12 March 2003 Resolved
TIGHTEN DOWN KEEL NUT BTW FRAMES 5 AND 6 IN STEERING COMPT. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Keel
Due 1 April 2003
Resolved 6 May 2003
Electrical › Electrical Distribution System (service)
Issued 12 March 2003 Resolved
INSTALL ELECTRICAL TAPE/INSULATION OVER CONNECTIONS SERVING BILGE PUMP IN STEERING COMPT.
Due 1 April 2003
Resolved 6 May 2003
Electrical › Electrical Distribution System (service)
Issued 12 March 2003 Resolved
SECURE WIRING SERVING BILGE PUMP IN STEERING COMP. TO ENSURE IT DOESN'T CHAFF THRU. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Due 1 April 2003
Resolved 6 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 March 2003 Resolved
DOUBLE CLAMP ALL EXHAUST FITTINGS IN STEERING COMPT. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 1 April 2003
Resolved 6 May 2003
Electrical › Electric Generation Source (service)
Issued 12 March 2003 Resolved
REMOVE PORTABLE BATTERY CHARGER IN #3 COMPT.
Condition: Placed in Improper Service
Due 1 April 2003
Resolved 12 March 2003
Electrical › Electrical Distribution System (service)
Issued 12 March 2003 Resolved
REMOVE ALL DEAD ENDED WIRING IN ENGINE ROOM. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 6 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 March 2003 Resolved
REPAIR CRACKED EXHAUST FITTING ON EXHAUST SERVING PORT ENGINE. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Piping (exhaust)
Due 1 April 2003
Resolved 6 May 2003
Engineering › Fuel Oil Service System
Issued 12 March 2003 Resolved
INSTALL FLAME IMPINGMENT DEVICE ON PLASTICE RACOR FILTER IN STEERING COMPT. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 6 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 March 2003 Resolved
DOUBLE CLAMP ALL EXHAUST FITTINGS IN ENGINE ROOM. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 1 April 2003
Resolved 6 May 2003
Electrical › Lighting (service)
Issued 12 March 2003 Resolved
INSTALL GLOBE ON LIGHT FIXTURE MISSING SAME IN ENGINE ROOM. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 6 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 March 2003 Resolved
RENEW ALL THIN METAL EXHAUST FITTINGS WITH HEAVIER FITTINGS OF CAST IRON, FIBERGLASS, ETC. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 1 April 2003
Resolved 6 May 2003
Engineering › Sea-water System (primary cooling)
Issued 12 March 2003 Resolved
RENEW ALL THRU HULL FITTINGS. EVIDENCE OF SEVERE ELECTROLYSIS PRESENT. FITTINGS SERVING MAIN DSL ENGINES ARE OK. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 6 May 2003
Construction/Loadline › Hull
Issued 12 March 2003 Resolved
REMOVE ALL ANGEL HAIR THROUGHOUT VESSEL. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Due 1 April 2003
Resolved 6 May 2003
Engineering › Bilge Water Management System
Issued 12 March 2003 Resolved
REMOVE PLASTIC COUPLINGS BETWEEN BILGE STRAINERS AND BILGE PIPING AND INSTALL METAL COUPLINGS. NO PASSENGERS FOR HIRE UNTIL CLEARED. LEGACY COMPONENT DESC: Piping
Due 1 May 2003
Resolved 6 May 2003
Engineering › Shafting/Propeller Arrangements
Issued 12 March 2003 Resolved
TIGHTEN PACKING GLAND SERVING PORT PROP SHAFT.
Due 1 May 2003
Resolved 6 May 2003
Electrical › Electric Generation Source (service)
Issued 12 March 2003 Resolved
REMOVE WIRING AND ELECTRIC HEATERS WHICH ARE NOT BEING USED. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Due 1 May 2003
Resolved 6 May 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 12 March 2003 Resolved
HAVE FIRE BUOY SYSTEM IN E/R CHECKED OUT AND SERVICED. PROVIDE COPY OF PAPERWORK TO ATTENDING MARINE INSPECTOR. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Damaged By Earlier Event
Due 1 May 2003
Resolved 6 May 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 November 2002 Resolved
Replace reflective tape on 14 adult PFD's and reduce total manning for adulats to 23 until PFD reflective tape is replaced. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Inspected new tape.
Lifesaving › Lifebuoys
Issued 8 November 2002 Resolved
Properly outfit vessel lifebuoys IAW 46 CFR 180.70. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Inspected lifebuoys.
Engineering › Bilge Water Management System
Issued 8 November 2002 Resolved
Prove proper operation of fire/bilge pump from every strainor location and operation of all "rule" style bilge pumps. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Tested fire and bile pump from all strainer locations, all satisfactory.
Electrical › Electric Supply System (service)
Issued 8 November 2002 Resolved
Install battery box covers on battery boxes. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Inspected battery box covers.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 8 November 2002 Resolved
Contact servicing agency and prove proper maintenace to the fixed fire fighting system in engine room LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Inspected service certificate.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 8 November 2002 Resolved
Replace one B-II fire extinguisher noted as being in poor condition during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Inspected new B-II fire extinguisher.
Operations/Management › Drills/Instruction
Issued 8 November 2002 Resolved
Perform Fire, Abandon Ship and Man Overbaord drills with a deck hand when CG INspector returns to clear deficiencies. LEGACY COMPONENT DESC: Fire
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Conducted drills.
Electrical › Lighting (service)
Issued 8 November 2002 Resolved
Repair engine room lighting so it works properly. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Observed lights working.
Lifesaving › Hand Flares
Issued 8 November 2002 Resolved
Replace both day smoke signals and night flares by 01 DEC 2002. LEGACY COMPONENT DESC: Condition
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 December 2002
Resolved 18 December 2002
Resolution: Observed flares.
Fire Fighting › Miscellaneous Items
Issued 8 November 2002 Resolved
Install a battery operated smoke detector in the passenger space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Observed smoke detector.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 November 2002 Resolved
Prove proper operation of main engine tachometers, high jacket water temperature alarms and low lub oil pressure alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Observed tacks and alarms.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 November 2002 Resolved
Remove unused/non-functional equipment from the engineroom and pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 December 2002
Resolution: Observed removed equipment.
Lifesaving › Emergency Outfit
Issued 8 November 2002 Resolved
Replace EPIRB battery and hydro-static relase by 01 DEC 2002.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2002
Resolved 18 December 2002
Resolution: Inspected EPIRB and hydrostatic release.
Fire Fighting
Issued 2 October 2001 Resolved
Prove proper operation of fireboy system to ensure both engines shutdown when system is activated.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Construction/Loadline
Issued 2 October 2001 Resolved
Prove proper operation of electric bilge pump in number two compartment.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Engineering
Issued 2 October 2001 Resolved
Properly label emergency fuel shutoffs.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 2 October 2001 Resolved
Properly install retroflective tape to life jackets.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Construction/Loadline
Issued 16 March 2001 Resolved
Properly plug the through hull fitting (connection for generator) that is not being used.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Engineering
Issued 16 March 2001 Resolved
Properly install a new cutlass bearing on the port shaft.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Engineering
Issued 14 August 2000 Resolved
USE OF STBD FUEL TANK IS PROHIBITED UNTIL RENEWED OR REPAIRED. IF RENEWED,PLANS MUST BE SUBMITTED FOR COATS GUARD REVIEW PRIOR TO MANUFACTURE FOR APPROVAL. IF FUEL TANK IS TO BE REPAIRED IT MUST BE COMPLETED NLT 31MAR01.I F NOT REPAIRED BY THIS DATE IT MUST BE REMOVED FROM THE VESSEL.
Condition: Unknown
Due 14 August 2000
Resolved 14 August 2000
Navigation
Issued 14 August 2000 Resolved
RENEW WORN PIN AND BUSHING ON HYDRAULIC RAM CONNECTION TO RUDDER GUIDE.
Condition: Unknown
Due 6 September 2000
Resolved 7 September 2000
Lifesaving
Issued 14 August 2000 Resolved
REPLACE HYDROSTATIC RELEASE FOR EPIRB, AND PROPERLY MARK HYDRO EXPIRATION DATE ON EPIRB.
Condition: Unknown
Due 14 August 2000
Resolved 14 August 2000
Lifesaving
Issued 10 August 1999 Resolved
PROPERLY SECURE LIFERING BRACKETS TO DECK RAIL.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Lifesaving
Issued 10 August 1999 Resolved
REPLACE DETERIORATED GRAB LINE ON LIFEFLOAT TOPSIDE OF BRIDGE.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Unknown
Issued 13 August 1998 Resolved
CONDUCT AND DOCUMENT REQUIRED CREW FIRE AND MAN OVERBOARD DRILLS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Fire Fighting
Issued 13 August 1998 Resolved
PROVIDE PROOF OF ANNUAL SERVICING OF BII FIRE EXTINGUISHER (LOCATED ON MAINDECK).
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 13 August 1998 Resolved
PROVIDE 13 ADULT LIFE PRESERVERS W/LIGHTS. VESSEL IS NOT AUTHORIZED TO CARRY MORE THAN 48 PERSONS ON A COASTWISE VOYAGE UNTIL THIS RQMNT IS CLEARED.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Construction/Loadline
Issued 14 August 1997 Resolved
REPLACE REACH ROD FOR BILGE SYSTEM VALVE IN FOREPEAK.
Condition: Unknown
Due 4 September 1997
Resolved 8 September 1997
Unknown
Issued 14 August 1997 Resolved
PROVIDE PROOF OF COMPLIANCE WITH EMERGENCY DRILL REQUIREMENTS IN 46 CFR 185.520/.524.
Condition: Unknown
Due 4 September 1997
Resolved 8 September 1997
Fire Fighting
Issued 14 August 1997 Resolved
PROVIDE PROPER FIRE HOSE IAW 46 CFR 181.15-10 (OLD T).
Condition: Unknown
Due 4 September 1997
Resolved 8 September 1997
Unknown
Issued 14 August 1997 Resolved
PROVIDE PROOF OF ENROLLMENT IN AN APPPROVED DRUG TESTING PROGRAM FOR CREW MEMBERS.
Condition: Unknown
Due 4 September 1997
Resolved 8 September 1997
Lifesaving
Issued 14 August 1997 Resolved
PROVIDE CG APPROVED 25 PERSON LIFE FLOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 October 1997
Resolved 16 October 1997
Unknown
Issued 14 August 1997 Resolved
PROVIDE PROOF OF COMPLIANCE WITH CREW CREW TRAINING REQUIREMENTS IN 46 CFR 185.420.
Condition: Unknown
Due 4 September 1997
Resolved 8 September 1997
Lifesaving
Issued 25 July 1997 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, COMPLETE ALL ITEMS ON MSO PHILADELPHIA WORKLIST DTD- 25JUL97, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Documentation
Issued 25 July 1997 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PRESENT VESSEL AND CREW FOR NEW TO ZONE INSPECTION BY MSO WILMINGTON, NC.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Unknown
Issued 12 June 1996 Resolved
VSL RESTRICTED TO 49 PASSENGERS AT OWNERS REQUEST WHILE AWAITING NEW COI REFLECTING NAME CHANGE AND PASS REDUCTION. VSL ONLY CARRIES 52 PFD'S.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Unknown
Issued 12 June 1996 Resolved
PROVIDE PROOF OF COMPLIANCE OF CREW TRAINING IAW 46 CFR 185.420
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Unknown
Issued 12 June 1996 Resolved
PROVIDE PROOF OF COMPLIANCE OF EMERGENCY DRILLS IAW 46 CFR 185.520 & 185.524
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Unknown
Issued 12 June 1996 Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Engineering
Issued 26 May 1993 Resolved
VESSEL NOT TO OPERATE UNTIL FLAME SCREEN PROPERLY REPLACED ON PORT AND STBDF/O TANK VENTS, TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR BY 3JUN93.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Engineering
Issued 9 July 1991 Resolved
CLEAN SCREEN FOR FORWARD BILGE PUMP & PROVE PROPER OPERATION.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Electrical
Issued 9 July 1991 Resolved
REPAIR INDEPENDANT GENERATOR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Electrical
Issued 9 July 1991 Resolved
PROVE PROPER OPERATION OF DECK & FLOOR LIGHTS OPERATIONS ARE RESTRICTED TO DAYTIME ONLY UNTIL LIGHTS ARE REPAIRED.
Condition: Unknown
Due 17 September 1991
Resolved 17 September 1991
Lifesaving
Issued 18 May 1990 Resolved
STENCIL VESSEL NAME ON 12 MAN LIFE FLOAT.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Documentation
Issued 18 May 1990 Resolved
PROPERLY POST COI AND STABILITY LETTER UNDER GLASS OR CLEAR PLASTIC.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Engineering
Issued 18 May 1990 Resolved
PROVE PROPER OPERATION OF LAZARET SUBMERSIBLE BILGE PUMP INDICATOR LIGHT.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Construction/Loadline
Issued 18 May 1990 Resolved
RENEW FOREPEAK HATCH COVER REETAINING CABLE.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Engineering
Issued 9 November 1988 Resolved
FREE UP TO MAKE OPERATIONAL REACH ROD FOR BILGE VALVE IN FORE PEAK.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Engineering
Issued 9 November 1988 Resolved
REPLACE TWO 1 1/4" BALL VALVES FOR THE MD COOLING EXHAUST.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Engineering
Issued 9 November 1988 Resolved
REPLACE THROUGH HULL FITTINGS FOR BILGE DISCHARGE IN AFT PEAK AND FUEL COMPARTMENT.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Lifesaving
Issued 6 August 1986 Resolved
RENEW LIFELINES ON LIFEFLOAT.
Condition: Unknown
Due 6 August 1986
Resolved 6 August 1986
Lifesaving
Issued 6 August 1986 Resolved
RENEW BRACKET FOR WATERLIGHT ON LIFEFLOAT STARBOARD SIDE.
Condition: Unknown
Due 6 August 1986
Resolved 6 August 1986
Electrical
Issued 6 August 1986 Resolved
REPLACE BROKEN AND MISSING LAMP GUARDS IN MACHINERY SPACE.
Condition: Unknown
Due 6 August 1986
Resolved 6 August 1986

Casualty record · 1

23 May 2003Routine · role: Involved in a Marine Casualty · activity 1799605
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

BLUE WATER PRINCESS, BLUEFIN II, BLUEWATER PRINCES (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.