Records from 1986 to 2026. Most recent: operational control imposed, 5 March 2026.
Inspection history · 76
5 March 2026
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8319846
6 February 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8067661
11 January 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7847735
30 November 2023
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7827585
21 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611899
28 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601109
19 January 2022
Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7382324
10 November 2021
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7343558
8 February 2021
Plan Review "T" Boat · Deficiency Check · Simplified Stability Test · Construction Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7157352
13 November 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7094668
6 February 2020
Deficiency Check · Drydock Exam · Plan Review "T" Boat · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6903380
4 June 2019
Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6703881
25 April 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6399140
26 January 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6344497
21 March 2017
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6111053
8 October 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6025735
17 March 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5835270
19 February 2016
Examination of Repairs · Damage Survey · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5818672
19 February 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5831749
12 January 2016
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5795789
25 May 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4321559
2 February 2012
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4237204
1 December 2011
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4199679
7 December 2009
Plan Review "T" Boat · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3646271
22 April 2009
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3458527
21 April 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3451611
5 May 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3191283
29 January 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3126131
3 April 2007
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2896731
28 March 2006
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2591381
23 January 2006
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2571498
9 September 2005
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2488170
21 July 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2431448
16 July 2005
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 2428901
20 June 2005
Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2343331
10 October 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2218163
10 October 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2218393
15 May 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2071076
13 February 2004
Simplified Stability Test
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1997184
16 January 2004
Annual Inspection · In-Service Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1978076
14 November 2002
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1705500
11 July 2002
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1644905
20 June 2002
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1633867
3 May 2001
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1064716
30 March 2001
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1458866
9 February 2001
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1447041
1 February 2001
Type not recorded
No type recorded · Station Bodega Bay · USCG Southwest District (CGD-SW) · Activity 2218412
21 March 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1372968
29 June 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1082625
26 April 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1420135
31 March 1999
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1384090
9 March 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388473
1 April 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402434
18 March 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388234
30 April 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1080225
12 March 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357533
22 March 1995
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1403932
31 January 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1162412
22 April 1993
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 826300
30 March 1993
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1145441
23 September 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1414083
17 April 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1461471
25 March 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1382477
2 March 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1270068
16 December 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1472291
18 September 1991
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 940747
6 March 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 904311
6 March 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1304280
13 March 1990
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1220801
9 March 1989
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1202372
17 February 1989
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1039864
22 November 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 892850
14 April 1988
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1033065
15 May 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1300507
23 April 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1300260
7 February 1986
Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 989100
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2026
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not complete annual inspection within +/- 90-day grace period and therefore is overdue for annual inspection. Conduct COI annual inspection, to the satisfaction of the MI, prior to the carriage of passengers-for-hire. 46 CFR 176.500 (b)(1)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2026
Resolution: Vessel completed annual exam.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 March 2026
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—Six hand red flare distress signals ...and Six hand orange smoke distress signals... MI identified 10 flares expired.
46 CFR 180.68701
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2026
Resolved 11 March 2026
Resolution: Received photo of newly purchased flares.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 March 2026
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. MI identified fire detection system not interconnected.
46 CFR 181.405
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2026
Resolved 27 May 2026
Resolution: Attended vessel and witnessed satisfactory test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2026
Resolved
...When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static. MI identified no grounding strap in place for fuel tanks.
46 CFR 182.445(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 27 May 2026
Resolution: Attended vessel and witnessed installation of proper grounding
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 March 2026
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. MI identified leak in bilge pump manifold and other spaces draining into E/R bilge.
46 CFR 182.25-1
"OLD T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 27 May 2026
Resolution: Attended vessel and witnessed satisfactory bilge test
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2026
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. MI identified the Radio Station Authorization onboard is for the HyperFish.
47 CFR 80.13
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2026
Resolved 27 May 2026
Resolution: Attended vessel and observed proper document in place
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 February 2025
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Port and starboard fuel shut off valves are not closing completely. Adjust the handles and pull stop mechanism to allow valves to close completely to the satisfaction of the MI.
46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel adjusted handles to allow valve to close.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 February 2025
Resolved
The following spaces must be equipped with a fire detection and alarm system... A space containing propulsion machinery. Smoke detector in the engine room
is inoperable. Make repairs or replace in kind to the
satisfaction of the MI. Vessel restricted to limited
coast wise route.
46 CFR 181.405(a)(1)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2025
Resolved 5 March 2025
Resolution: Vessel installed new fire alarms satisfactory.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 February 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces...A space with a through-hull fitting below the deepest load waterline, such as a lazarette. High level alarm for lazarette is inoperable. Vessel restrictions: conduct round of lazarette every hour while underway. Vessel has 2 weeks to correct deficiency.
46 CFR 182.530(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel replaced high level alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Bilge pump located on the starboard engine is leaking 1 drop per second. Make repairs to the satisfaction of the MI.
46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 5 March 2025
Resolution: Vessel replaced impeller and gasket satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Bow valve and bilge suction gate valve located on the bilge manifold did not open and close smoothly. Lubricate and actuate valves to ensure proper operation to the satisfaction of the MI.
46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Valve actuated to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 February 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Marine Inspector identified that the sink drain hose penetration had insufficient vapor tight integrity. Conduct repairs to the satisfaction of the Attending Marine Inspector. Sink drain through bulkhead hose from engine room to lazarette was not vapor tight. Make the through bulkhead hole vapor tight to the satisfaction of the MI.
46 CFR 177.405(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel added foam to reinforce vapor tight boundary.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 February 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Pull cable for FM200 system that runs from the engine room to the space forward of the engine room though bulkhead was not vapor tight. Make the through bulkhead penetration vapor tight to the satisfaction of the MI.
46 CFR 177.405(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel added foam to reinforce vapor tight boundary.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 February 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Two through bulkhead white hoses that run from the engine room to the space forward of the engine room on the starboard side of the bulkhead are not vapor tight. Make through bulkhead holes vapor tight to the satisfaction of the MI.
46 CFR 177.405(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel added foam to reinforce vapor tight boundary.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 February 2025
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment... Fire boy pull cable run located in the space forward of the engine room had too much slack in it. Take slack of the pull cable run to the satisfaction of the MI.
46 CFR 176.810(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel removed slack out of FM200 pull cable to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 February 2025
Resolved
Each disposable hydrostatic release unit must be marked
with an expiration date of two years after the date on
which the unit is installed. EPIRB hydrostatic release
is expired. Replace hydrostatic release to the
satisfaction of the MI. Vessel is restricted to no more
than 3 nautical miles from shore until hydrostatic
release is replaced.
46 CFR 185.740(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel replaced hydrostatic release for EPIRB.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 6 February 2025
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: inspect all railings and bulwarks and their attachment to the hull structure. Port rail stanchion located amidship is loose, tighten rail stanchion to the satisfaction of the MI.
46 CFR 176.25-5(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 5 March 2025
Resolution: Vessel tightened port rail.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2025
Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. Two aft benches located on the stern are not properly secured. Secure the benches to the satisfaction of the MI.
46 CFR 177.820(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel removed benches.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 February 2025
Resolved
All vessels must have navigation lights that are in
compliance with the applicable sections of the
International and Inland Navigation Rules... Starboard
navigation light is extinguished. Replace light to the
satisfaction of the MI. Vessel restrictions: prior to daylight operations or times of restricted visibility.
46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2025
Resolution: Vessel provided pictures to show navigation light is operable, photos attached.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 February 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems.. Stern light bulb is extinguished, and the cover is damaged. Replace the light bulb and bulb cover to the satisfaction of the MI.
46 CFR 176.806
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel replaced stern light assembly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring buoy was missing the vessels name. Put vessels name on the ring buoy to the satisfaction of the MI.
46 CFR 185.604
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 5 March 2025
Resolution: Vessel added name to ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 February 2025
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. 1 adult life jacket light was inoperable. 1 child sized life jacket was missing a light. Replace the light/batteries to the satisfaction of the MI.
46 CFR 180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 5 March 2025
Resolution: Replaced light on both PFD's.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 February 2025
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Propane tanks located in the most forward compartment underneath the operating station needs to be stowed in an open area. Relocate the propane tanks to the open deck to the satisfaction of the MI.
46 CFR 185.100
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel relocated propane tanks to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 February 2025
Resolved
A passenger accommodation space must not contain: Electrical generation equipment or transformers, high temperature parts, pipelines, rotating assemblies, or any other item that could injure a passenger, unless such an item is adequately shielded or isolated. Space heater located in the most forward compartment underneath the operating station needs to be secured so it does not shift while underway. Secure the heater to the satisfaction of the MI.
46 CFR 177.800(d)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 18 February 2025
Resolution: Vessel properly secured space heater to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 February 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to...provide services necessary for safety under normal and emergency conditions. Generator was inoperable. Make repairs and operate generator to the satisfaction of the attending MI. Vessel restriction: Prior to operation of the generator.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 February 2025
Resolution: Vessel ran generator satisfactory to the attending MI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Minimum requirements)
Issued 6 February 2025
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers...Each EAP education program must include at least the following elements:...display and distribution of a community service hot-line telephone number for crewmember assistance. Drug and alcohol hot line was not posted on the vessel. Print and post the hot line to the satisfaction of the MI.
46 CFR 16.401(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 5 March 2025
Resolution: Vessel posted hot line.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 January 2024
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. Vessel's life raft inflation line was incorrectly attached to the raft frame. Vessel to attached inflation line to weak link of the life raft release mechanism to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2024
Resolution: Vessel attached line appropriatly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 January 2024
Resolved
An interconnected detection alarm system must: Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c). Vessel is outfitted with two fire detection alarms (main cabin and engine room). Actuation of one alarm would not activate the other. Vessel to repair detectors to activate when the other alarms to the satisfaction of the attending marine inspector. Vessel restricted to Limited Coastwise route until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 March 2024
Resolution: Vessel installed correct fire detection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 January 2024
Resolved
A vessel on a coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Vessel has only 4 red flare distress signals. Vessel to acquire two red flare distress signals to total 6 to the satisfaction of the attending marine inspector. Vessel limited to lakes, bays, and sounds route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 February 2024
Resolution: Vessel acquired amount of flares.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 January 2024
Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Vessel does not have documentation of EPIRB testing. Vessel to show current log or start a log showing monthly checks to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 1 February 2024
Resolution: Vessel started monthly log.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 January 2024
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard. Vessel does not have logs showing drills being conducted. Vessel to show proof or start log of drills to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 13 March 2024
Resolution: Vessel started correct logging system.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 January 2024
Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot and Coast Guard Light List. Vessel has outdated
U.S. Coast Pilot and Coast Guard Light List. Vessel to obtain updated copies of both publications to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 2 February 2024
Resolution: Vessel has current versions of both.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 January 2024
Resolved
Every vessel must have detailed inspection of the radio installation by an FCC-Licensed technician every five years. Vessel’s certificate has expired and needs renewal. Vessel to have radio installation inspected to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 1 February 2024
Resolution: Vessel received updtate Radio Telephony cert.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 January 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Fixed-gas fire extinguishing systems, the owner or managing operator must provide satisfactory evidence of the required servicing. Vessel does not have satisfactory evidence of the proper inspections and test on fire protection equipment. Vessel to provide satisfactory evidence to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 13 March 2024
Resolution: Vessel provided proof of correct fire servicing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 January 2024
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2.5 gallon buckets. Buckets onboard were 5 gallons. Vessel to either replace with 2.5 gallon buckets, or drill holes in 5 gallon buckets to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 13 February 2024
Resolution: Vessel now has 03 2.5 gallon buckets w/ lanyards.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 January 2024
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40. Consortium letter provided onboard expired in 2023. Vessel to provide up-to-date consortium letter to the satisfaction of the attending marine inspector.
46 CFR 16.113
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 1 February 2024
Resolution: Vessel showed updated consortium letter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 January 2024
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Strainers were missing on all bilge suctions. Vessel to install strainers to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 13 February 2024
Resolution: Vessel installed suitable strainers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 January 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retro-reflective material. Vessel’s life buoy does not have any retro-reflective material. Vessel to apply retro-reflective material to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 1 February 2024
Resolution: Vessel applied retro tape to life ring.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 January 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards,including fire, caused by or originating in electrical equipment, and electrical shock. Vessel has dead end wires behind VHF radio on the bridge. Vessel to cap or remove dead end wires to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 13 March 2024
Resolution: Vessel correctly capped dead-end wires.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 January 2024
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Five bulkhead penetrations found in amidship compartment bulkhead to the engine room. Vessel to seal all penetrations to ensure vapor seal to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 1 February 2024
Resolution: Vessel sealed all penetrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests including the following: Inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. While operating the vessel underway, a portion of the starboard exhaust aft of the turbo which is covered in lagging was continually steaming, indicating a leak beneath the lagging. Remove lagging and make available for follow up inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2024
Resolved 1 February 2024
Resolution: Tested exhaust and found no leaking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 November 2022
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Lazarette and Engine Room bilge suction strainers are missing.
46 CFR 182.510(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2022
Resolved 30 December 2022
Resolution: Strainers installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 November 2022
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. Ring buoy is deteriorated, and vessel name is illegible.
46 CFR 185.604(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2022
Resolved 30 December 2022
Resolution: Replaced ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 November 2022
Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulation and protected in compliance with 177.405(b) and 177.970 of this chapter. Starboard exhaust piping is leaking.
46 CFR 182.425(b)(3)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2022
Resolved 11 May 2023
Resolution: Repaired exhaust and added rudder stops to prevent future problems.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 November 2022
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Fuel shut off valves are not marked.
46 CFR 143.260
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 December 2022
Resolved 11 May 2023
Resolution: Added placards.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 November 2022
Resolved
A hatch exposed to the weather must be watertight. Port side engine room hatch is leaking.
46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2022
Resolved 31 March 2023
Resolution: Vessel fixed insulation, hatch is now wateritght.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 November 2022
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Lighting above the starboard engine does not have a protective covering.
46 CFR 183.410(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2022
Resolved 31 March 2023
Resolution: Vessel added protective covering to light fixture.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 November 2021
Resolved
Batteries shall be effectively screened by a cage or similar structure to minimize danger of accidental spark through dropping a metal object across terminals. Vessels batteries do not have a cover over terminals.
46 CFR 183.05-20(a)
"Old T"
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 30 December 2021
Resolution: Operator sent photos of battery terminal cover installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 November 2021
Resolved
Batteries terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Vessel connects buses to batteries with wingnut connectors, which are considered temporary connectors. Replace and connect with manufacturer recommended connections that are permanent.
46 CFR 183.05-20 (c)
"Old T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 30 December 2021
Resolution: Operator sent photos of terminals secured with proper nuts.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 November 2021
Resolved
Provision must be made for closing all supply duct cowls or scoops for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel has several supply ducts integral to the bulwarks that do not have a method of closure.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 30 December 2021
Resolution: Operator sent photos of footballs installed as ventilation securing devices.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 November 2021
Resolved
Each hatch exposed to the weather must be watertight. Each hatch cover must be attached to the hatch frame or coaming by hinges, captive chain, or other device to prevent its loss. Engine room hatch located on centerline and under the cutting station found leaking. Forepeak hatch leaks and has a broken retaining lanyard.
Repair at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2022
Resolved 19 January 2022
Resolution: During drydock inspection. MI attested to repairs. Special note added to test with water on next annual due to water not available at yard.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 November 2021
Resolved
Vessels operated solely within 20 NM of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 80.1101(c)(2). Vessel is equipped with DSC capable radio, but radio is not set up to broadcast MMSI or GPS position.
47 CFR 80.905(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 12 November 2021
Resolution: Received photo of new VHF with MMSI and position loaded.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 10 November 2021
Resolved
Except on a vessel limited to daytime operations, the
compass must be illuminated. Bulb missing from magnetic
compass at operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2021
Resolved 30 December 2021
Resolution: Operator sent photo of new bulb installed and operational.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 10 November 2021
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Steering linkage bar is wasted and needs to be replaced.
46 CFR 182.30-1(a)
"Old T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2021
Resolved 24 November 2021
Resolution: Vessel replaced linkage bar. Sent photos of installation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 March 2020
Resolved
Permission for repairs or alterations. Vessel planned to move electric panel switch board to facilitate future change of structure. Inspector requested electrical plan for OCMI review 6 FEB. During visit of progress 5 MAR to verify plan, vessel had began construction and also constructed a new switchboard not in kind. The electric plan was unavailable for review during this visit.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2020
Resolution: Breaker verified from Blue Seas panel order (UL 489 for the 120V AC panel, 12V breakers had in line fuse breaker added).
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 June 2019
Resolved
The discharge ends of vent pipes shall terminate on the hull exterior as high above the waterline as practicable. Ventilation pipe for starboard fuel tank was fractured shortly after exiting the fuel tank in the engine room and allowing flammable vapors to discharge and accumulate into the engine room. Complete permanent repairs to the satisfaction of the attending MI.
46 CFR 182.20-35(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2019
Resolved 13 June 2019
Resolution: MI attended vessel and witnessed the repaired vent pipe for the starboard fuel tank.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2019
Resolved
An adult life jacket must be provided for each person onboard a vessel. Vessel was outfitted with several unusable lifejackets. Remaining usable adult life jackets is 17. Vessel restricted from carrying more than 17 adults until new lifejackets are onboard and inspected by attending MI.
46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2019
Resolved 13 June 2019
Resolution: MI attended vessel and counted adequate number of lifejackets that matched required number of lifejackets on the vessel's COI.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 June 2019
Resolved
Any vessel of at least five net tons which engages in fisheries on the navigable waters of the US must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel's COD is expired. Provide valid COD prior to carrying passengers.
46 CFR 67.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2019
Resolved 15 August 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 June 2019
Resolved
At each initial and subsequent inspection for certification the owner shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Both engine exhausts in lazarette are damaged from the rudder connecting rod when hard over. Repair existing damage to exhausts and configure steering gear arrangement to prevent future damage.
46 CFR 176.814
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
Resolution: Attending MI witnessed satisfactory steering test. Test attested to no further damage to exhaust system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2019
Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Engine room and lazarette bilge suctions missing strainers. Install strainers on engine room and lazarette bilge suctions.
46 CFR 182.25-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
Resolution: Strainers were installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 4 June 2019
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Medical certificate for owner, who serves as one of the Masters onboard, was expired. Provide valid medical certificate prior to serving in a position which requires an MMC onboard.
46 CFR 15.401
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2019
Resolved 15 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 June 2019
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery etc. Port engine has an exposed belt. Affix suitable guard over port engine belt.
46 CFR 177.35-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 9 August 2019
Resolution: Operator installed casserole pan over the moving belt.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 June 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner shall be prepared to conduct tests of machinery, fuel, and piping systems, including the following: Operational test of all valves in fuel lines by operating locally and at remote operating stations. Starboard fuel shutoff leaked diesel at a slow rate upon actuation. Repair diesel leak on shutoff valve.
46 CFR 176.804(f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 June 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: charts, US coast pilot, Coast Guard light list. Vessel's charts, coast pilot, and light list were expired. Provide up to date charts and publications.
46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
Resolution: Owner uses an iPhone. MI should verify charts and publications are downloaded at every exam.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in 4.03-2 shall comply with the requirements of 4.06. Vessel does not have alcohol testing capabilities onboard. Operations restricted to within two hours of a suitable testing facility.
46 CFR 185.212
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2019
Resolved 22 August 2019
Resolution: Owner procured alcohol test strips.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2019
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Adult and child life jackets were combined and not marked in forward main cabin (V-Berth) area. Separate and properly mark locations for child life jackets.
46 CFR 180.78(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
Resolution: MI witnessed satisfactory separation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 June 2019
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready fo inspection of electrical equipment. Exposed wires present in forward cabin (V-Berth). Properly cap or remove dead end wires.
46 CFR 176.806
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 9 August 2019
Resolution: Dead-end wires are sufficienctly capped.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2019
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Stern light, mastlight, and starboard running light were not operational. Anchor light was taped to the mast and not affixed in a way ensure reliability of operation.
46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
Resolution: MI witnessed proper operation of lights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. First aid kit onboard contained expired medicines. Provide first aid kit with non expired medicines and in compliance with the items in 160.041.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
Resolution: MI observed fully stocked first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 June 2019
Resolved
The master and crew of a vessel will be familiar with the content of an have mounted at the operating station, emergency instructions containing the action to be taken in the event of fire, heavy weather, or man overboard conditions. Man overboard instructions do not match shipboard procedures and the contents are obscured by a splotchy plexiglass cover. Update procedures to reflect accurate vessel response and ensure procedures are easily readable during an emergency situation.
46 CFR 185.510
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 15 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
Marine employers shall establish programs for the chemical testing of dangerous drugs on a random basis of crewmember on inspected vessels. Owner could not provide sufficient documentation to prove adequate drug and alcohol program was in place. Provide sufficient documentation to attending MI to verify compliance with Drug and Alcohol Program.
46 CFR 16.230
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
Resolution: Owners provided sufficient DAPI documentation.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 June 2019
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Crew could not locate engine room ventilation closures. Demonstrate operation of ventilation closures.
46 CFR 182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 8 August 2019
Resolution: MI witnessed proper operation of fire dampers.
Communications › Radio Communications › EPIRB
Issued 25 April 2018
Resolved
The vessel's EPIRB's registration is expired. 47 CFR 80.1061(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: Vessel registered EPIRB with NOAA.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 April 2018
Resolved
Vessel does not have alcohol testing strips on board. 46 CFR 4.06-3(a)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 1 May 2018
Resolution: Owner/operator procured alcohol test strips.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 April 2018
Resolved
Vessel has child life jackets stowed in a compartment mixed with adult life jackets. 46 CFR 180.78 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: Owner separate child size life jackets from adult life jackets.
Fire Fighting › Fire Bucket › Availability
Issued 25 April 2018
Resolved
Vessel does not have fire buckets onboard. 46 CFR 181.610
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: Vessel has fire buckets onboard.
Engineering › Bilge Water Management System › Strainer
Issued 25 April 2018
Resolved
The vessel is missing strainers on Lazarette and engine room bilge suctions. 46 CFR 182.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: Owner installed suitable strainer on Lazarette and Engine Room bilge suction piping.
Lifesaving › Hand Flares › Expired
Issued 25 April 2018
Resolved
Flares were expired. 46 CFR 180.68
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 25 April 2018
Resolution: Vessel placed new flares onboard.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 April 2018
Resolved
Vessel has wing nuts on starboard batteries. 46 CFR 183.350(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: Owner removed wing nuts and installed permanent type connectors.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 April 2018
Resolved
Vessel does not have floating water light attached to ring buoy with lanyard. Life ring is attached directly to throw line bag which is attached to the ring buoy. 46 CFR 180.70(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: Owner installed lanyard with corrosion resistant clip and attached float light around ring buoy body.
Lifesaving › Lifebuoys › Serviceable
Issued 25 April 2018
Resolved
Life ring onboard is unserviceable and deteriorated. 46 CFR 180.70(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: Owner placed new life ring in service.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 April 2018
Resolved
Owner/Operator could not locate vent closures for engine room vents. 46 CFR 182.465 (h)
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: Found vent closures and are readily available.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 April 2018
Resolved
Vessel has expired radiotelephony certificate. 47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 1 May 2018
Resolution: Vessel has new readiotelephony certificate on board.
Fire Fighting › Fire Bucket › Availability
Issued 21 March 2017
Resolved
Vessel missing all 03 fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Resolution: Rep provided proof of buckets onboard.
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 February 2016
Resolved
effect permanent repair to port and starboard exhaust pipe renewing fiberglass forward of exhaust port on transom to muffler
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2016
Resolution: All repairs satisfatory
Navigation › Piloting/Steering › Notices to Navigation
Issued 25 May 2012
Resolved
Provide current NTM's onboard.
Condition: Improper/Lack of Maintenance
Due 25 May 2012
Resolved 25 May 2012
Navigation › Piloting/Steering › Marine Charts
Issued 25 May 2012
Resolved
Provide current Chart.
Condition: Improper/Lack of Maintenance
Due 25 May 2012
Resolved 25 May 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 May 2012
Resolved
Prove proper operation of center compartment visual alarm.
Condition: Improper/Lack of Maintenance
Due 25 May 2012
Resolved 25 May 2012
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 21 April 2009
Resolved
Prove proper operation of Engine Room and Lazarette bilge, high level alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2009
Resolved 22 April 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 April 2009
Resolved
Prove proper operation of Stbd Emergency F/O Shut-off Valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2009
Resolved 22 April 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 21 April 2009
Resolved
Provide lens cover or new lighting fixtures for head light and fixture in the amidships compartment.
Condition: Improper Installation
Due 21 May 2009
Resolved 22 April 2009
Electrical › Electric Supply System (service) › Cable
Issued 21 April 2009
Resolved
Secure loose/bare wiring through out vessel. Remove all wire nuts and make permanent connections.
Condition: Improper/Lack of Maintenance
Due 21 May 2009
Resolved 22 April 2009
Lifesaving › Buoyant Apparatus › Marking
Issued 21 April 2009
Resolved
Re-stencil vessel name on buoyant apparatus.
Condition: Improper/Lack of Maintenance
Due 21 May 2009
Resolved 22 April 2009
Lifesaving › Lifebuoys › Serviceable
Issued 21 April 2009
Resolved
Provide new life ring.
Condition: Improper/Lack of Maintenance
Due 21 May 2009
Resolved 22 April 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 April 2009
Resolved
Conduct U/W drills prior to carrying passengers.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 22 April 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 April 2007
Resolved
Provide current copy of the CG Light List.
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 10 April 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 3 April 2007
Resolved
Provide current copy of US Coast Pilot.
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 10 April 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 April 2007
Resolved
Provide complete first aid kit.
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 10 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2007
Resolved
Remove/ cap 2 loose wires in engine room overhead.
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 10 April 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 April 2007
Resolved
Replace 1 adult life jacket. Passenger count reduced by one until adult life jacket is replaced.
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 10 April 2007
Engineering › Fuel Oil Service System › Valve
Issued 3 April 2007
Resolved
Repair port side emergency fuel shut off.
Action required: 705 - Other - as specified
Due 3 April 2007
Resolved 3 April 2007
Fire Fighting › Fire Bucket › Lanyard
Issued 3 April 2007
Resolved
Provide lanyards for all 3 fire buckets.
Action required: 705 - Other - as specified
Due 3 April 2007
Resolved 3 April 2007
Documentation › Certificates/Documents › FCC SSL
Issued 3 April 2007
Resolved
Provide current FCC Safety License.
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 10 April 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 June 2005
Resolved
Stencil vessels name on all PFD's.
Due 20 July 2005
Resolved 21 July 2005
Lifesaving › Lifefloat › Markings
Issued 20 June 2005
Resolved
Stencil vessel name on 6 person lifefloat and oars.
Due 20 July 2005
Resolved 21 July 2005
Lifesaving › Lifefloat › Paddle
Issued 20 June 2005
Resolved
Attach oars to 6 person lifefloat.
Due 20 July 2005
Resolved 21 July 2005
Documentation › Logs/Records › Logbook (official)
Issued 20 June 2005
Resolved
Create training and lifesaving equipment maintenance record logbook.
Due 20 July 2005
Resolved 21 July 2005
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 20 June 2005
Resolved
Make engine room vapor tight in way of penetrations in overhead and bulkheads.
Due 20 July 2005
Resolved 21 July 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 20 June 2005
Resolved
Install flame shield for remotely operated fuel shut-off valves.
Due 20 July 2005
Resolved 21 July 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 June 2005
Resolved
Properly attach floating waterlight to ring buoy with a 3-8ft lanyard w/corrosion resistant clip.
Due 20 July 2005
Resolved 21 July 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 June 2005
Resolved
Secure port navigation lights.
Due 20 July 2005
Resolved 21 July 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 June 2005
Resolved
Provide outlet cover for junction box in way of forward accommodation space.
Due 20 July 2005
Resolved 20 June 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 October 2004
Resolved
Provide onboard number of child and adult lifejackets required by COI, vessel is limited to 25 passengers until cleared.
Due 17 October 2004
Resolved 14 October 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 10 October 2004
Resolved
Provide onboard number of portable fire extingushers required by COI. Vessel is restricted from carrying passengers until cleared.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 October 2004
Resolved
Provide origninal certificate of documentation onboard vessel.
Due 17 October 2004
Resolved 10 October 2004
Personnel › Certificates/Documents/Licenses › License, Master
Issued 10 October 2004
Resolved
Provide original masters license onboard.
Due 17 October 2004
Resolved 10 October 2004
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 October 2004
Resolved
Provide senior deckhand designation letter onboard as required by COI in accordance with NVIC 1-91.
Due 17 October 2004
Resolved 10 October 2004
Navigation › Collision/Grounding Avoidance
Issued 16 January 2004
Resolved
Renew as original Stbd running light fixture. Clean mast light and Port running light of all paint overspray. LEGACY COMPONENT DESC: Navigation Lights
Due 23 January 2004
Resolved 22 January 2004
Lifesaving
Issued 16 January 2004
Resolved
Mark lifefloat paddles with vessel name.
Due 23 January 2004
Resolved 22 January 2004
Lifesaving
Issued 16 January 2004
Resolved
Renew 3 each float light batteries with approved type.
Due 23 January 2004
Resolved 22 January 2004
Lifesaving › Buoyant Apparatus
Issued 16 January 2004
Resolved
Install proper size weak link in way of BA.
Due 23 January 2004
Resolved 22 January 2004
Engineering › Fuel Oil Service System
Issued 16 January 2004
Resolved
Replace fuel hose in way of generator with approved type IAW 46 CFR 182.720 LEGACY COMPONENT DESC: Hose
Due 23 January 2004
Resolved 22 January 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 January 2004
Resolved
Properly mark hatch in way of bow "EMERGENCY EXIT, KEEP CLEAR" IAW 46 CFR 185.606
Due 22 February 2004
Resolved 29 January 2004
Communications › Radio Communications
Issued 20 June 2002
Resolved
Provide updated copy of radio telephony safety certificate. LEGACY COMPONENT DESC: Radio Telephony Safety Certificate
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 June 2002
Documentation › Logs/Records › Logbook (official)
Issued 20 June 2002
Resolved
Provide logbook for logging all crew training, drills, and monthly epirb tests.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 June 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 June 2002
Resolved
Provide updated copy of Coast Guard Light list.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 June 2002
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 20 June 2002
Resolved
Install smoke detectors in the following spaces: Galley area, and crew accomodations
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 June 2002
Fire Fighting › Fire Pumps
Issued 20 June 2002
Resolved
Provide three (3) 2.5 gal buckets with lanyard for the purpose of firefighting. Buckets are to be labeled "FIRE BUCKETS". LEGACY COMPONENT DESC: 2.5 gal buckets
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 June 2002
Resolved
Install guards IVO of both main engine pulleys.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 June 2002
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 June 2002
Resolved
Provide proof of participation in random drug testing program.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 June 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 June 2002
Resolved
Provide updated first aid kit.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2002
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 June 2002
Resolved
Demonstrate proper operation of engineroom bilge alarm, and lazzarette bilge alarm.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2002
Engineering
Issued 9 February 2001
Resolved
REMOVE INSULATION FROM FUEL TANKS AND MAKE AVAILABLE FOR EXTERNAL INSPECTION BY THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Construction/Loadline
Issued 26 April 1999
Resolved
Provide high level bilge alarms for MSD tank space and lazarette.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Engineering
Issued 9 March 1998
Resolved
MAKE PERMANENT REPAIRS TO STARBOARD ENGINE EXHAUST.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 9 March 1998
Resolved
BUCKLE ON LIFE JACKET INOPERATIVE. REPLACE LIFEJACKET OR REPAIR BUCKLE._x001C_ RESTRICTED TO CARRYING 48 TOTAL PERSONS UNTIL CORRECTED.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 9 March 1998
Resolved
PROVIDE BUOYANT APPARATUS WITH WATER LIGHT.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Electrical
Issued 9 March 1998
Resolved
REPAIR GENERATOR SOLENOID.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1996
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPLACE THE LIFE LINE FOR THE VESSEL'S RING BUOY.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Lifesaving
Issued 12 March 1996
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, INSTALL A SUITABLE FLOAT FREE LAUNCHING APPARATUS FOR THE VESSEL'S LIFE FLOAT.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Documentation
Issued 12 March 1996
Resolved
PROVIDE EVIDENCE OF A FCC COMMUNICATIONS ACT SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996